Allen, TX -AC and Heating Repair Service

HVAC Contractor near Allen TX

Air conditioning is a huge part of life in Allen TX and the surrounding Texas communities, and that means you need great heating and air conditioning repair service. That's why we've made it our mission at Adon Complete Air Conditioning & Heating to make high-efficiency HVAC unit systems affordable and accessible for home and business owners in Allen.

Heating & AC Repair Service near Allen TX

Whether you need residential air conditioning repair or a new HVAC system installed for your existing heating and air conditioning systems, our comfort specialists can help.

We invite you to read some of our reviews below from neighbors in the Allen, TX area!

We understand that every home and business in Allen, TX has unique heating and cooling needs, which is why we offer a full range of residential and light commercial HVAC services.

We install, repair and maintain:

  • Air conditioners
  • Heat pumps
  • Furnaces
  • Ductless mini-splits
  • Indoor air quality systems
  • Thermostats

All of our HVAC unit installations are backed by a ten-year labor warranty and we offer a two-year heating and air conditioning maintenance plan.

We also offer 24/7 emergency air conditioning repair service throughout the summer months to keep your family in Allen cool and protected.

Adon Complete Air Conditioning and Heating  is Your Local Air Conditioning & Heating Repair Service Provider

Families in Allen, TX know how important it is to take action right away on air conditioning repair and service. Turn to our reliable, dedicated comfort specialists for the HVAC services you need and the outstanding customer service you deserve.

Whether you need a new system or service for your existing unit, contact us online or give us a call at (903) 482-4900 today to schedule your service in Allen.

Schedule Service Today. We Treat You Like Family!

Recent Jobs and Reviews in Allen, TX

Rated 4.7 out of 5 stars based on 6 customer reviews

Customers say: # Review Sentiment Analysis The reviews reflect an overwhelmingly positive sentiment toward the company's HVAC services. Customers consistently praise the technicians for being knowledgeable, professional, and thorough in their work. Many reviewers highlight the clear communication provided by staff, noting how well technicians explained system issues and maintenance procedures. The service quality is frequently described as "excellent" with multiple mentions of staff going "above and beyond" expectations. Customers appreciate the technicians' attention to detail, honesty, and courteous demeanor. The company appears to have built strong customer loyalty, with several reviewers mentioning they are long-term customers or would highly recommend the service to others. The overall tone is decidedly positive, with recurring themes of professionalism, reliability, helpfulness, and quality workmanship. Customers also value the maintenance programs offered and the comprehensive nature of the service visits.

Reviews

AC
Great guy
Carter - Allen, TX 75002
Great Service
He is very polite and patient. Explains all the options I have and provided great service. Thanks!
Hui - Allen, TX 75013
Service was great
Great
Mickel - Allen, TX 75002
Great Service
Very Professional
Eduardo - Allen, TX 75002
Excellent service, affordable, professional
Our A/C broke when the weather started to get hot. We called Adon Complete, and Charles came. He was experienced and professional. He and his crew replaced our 20-year old unit, and our system is up and running just in time for summer. I would recommend Adon Complete for all my friends and neighbors.
Kent - Allen, TX 75002
Very friendly
Mary - Allen, TX 75002

Job Locations

Matthew C.
Matthew C.
Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure. Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Allen, TX 75002
Allen, TX - Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. 

Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure.
Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Allen, TX - Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. 

Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure.
Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Shelby S.
Shelby S.
I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Allen, TX 75013
Allen, TX - I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Allen, TX - I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Brayden W.
Brayden W.
Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Allen, TX 75013
Allen, TX -  Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Allen, TX -  Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Brayden W.
Brayden W.
Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Allen, TX 75013
Allen, TX - Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Allen, TX - Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Matthew C.
Matthew C.
Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Allen, TX 75013
Allen, TX - Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed  they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Allen, TX - Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed  they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Matthew C.
Matthew C.
Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Allen, TX 75013
Allen, TX - Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Allen, TX - Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Matthew C.
Matthew C.
Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Allen, TX 75013
Allen, TX - Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Allen, TX - Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Brayden W.
Brayden W.
Performed maintenance on 5 carrier furnaces 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Dining room 1 - storage left The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Allen, TX 75013
Allen, TX - Performed maintenance on 5 carrier furnaces 

 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Dining room 1 - storage left 
The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Allen, TX - Performed maintenance on 5 carrier furnaces 

 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Dining room 1 - storage left 
The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Jesse V.
Jesse V.
I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Allen, TX 75002
Allen, TX - I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Allen, TX - I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Matthew C.
Matthew C.
Performed a complete heating system maintenance and inspection. 2025 Gas system. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F. Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”. I visually inspected the outdoor unit, The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.
Allen, TX 75002
Allen, TX - Performed a complete heating system maintenance and inspection.  2025 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F.

Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Allen, TX - Performed a complete heating system maintenance and inspection.  2025 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F.

Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Allen, TX 75002
Allen, TX - I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Allen, TX - I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Shelby S.
Shelby S.
I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Allen, TX 75002
Allen, TX - I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Allen, TX - I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.
Allen, TX 75002
Allen, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
 
Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.
Allen, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
 
Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.
Shelby S.
Shelby S.
Blower Motor & Control Board Replacement (Trane Hyperion Furnace) Scope of Work: Remove and replace the blower motor and furnace control board in the Trane Hyperion air handler. Work includes full electrical reconnection, system calibration, and operational testing to ensure proper airflow and communication with the outdoor unit. Materials & Equipment: (1) OEM Trane blower motor assembly (1) OEM Trane control board Mounting hardware and wiring supplies Replacement OEM parts are not locally in stock, we will have to order them to be transferred. ETA 1 to 2 business days once estimate is approved Special Note: Due to the Hyperion cabinet design, partial disassembly of the unit is required to access and remove the blower assembly. This process ensures proper installation and alignment of the new motor and components.
Allen, TX 75013
Allen, TX - Blower Motor & Control Board Replacement (Trane Hyperion Furnace)

Scope of Work:
Remove and replace the blower motor and furnace control board in the Trane Hyperion air handler. Work includes full electrical reconnection, system calibration, and operational testing to ensure proper airflow and communication with the outdoor unit.

Materials & Equipment:
(1) OEM Trane blower motor assembly
(1) OEM Trane control board
Mounting hardware and wiring supplies


Replacement OEM parts are not locally in stock, we will have to order them to be transferred. ETA 1 to 2 business days once estimate is approved 

Special Note:
Due to the Hyperion cabinet design, partial disassembly of the unit is required to access and remove the blower assembly. This process ensures proper installation and alignment of the new motor and components.
Allen, TX - Blower Motor & Control Board Replacement (Trane Hyperion Furnace)

Scope of Work:
Remove and replace the blower motor and furnace control board in the Trane Hyperion air handler. Work includes full electrical reconnection, system calibration, and operational testing to ensure proper airflow and communication with the outdoor unit.

Materials & Equipment:
(1) OEM Trane blower motor assembly
(1) OEM Trane control board
Mounting hardware and wiring supplies


Replacement OEM parts are not locally in stock, we will have to order them to be transferred. ETA 1 to 2 business days once estimate is approved 

Special Note:
Due to the Hyperion cabinet design, partial disassembly of the unit is required to access and remove the blower assembly. This process ensures proper installation and alignment of the new motor and components.
Brayden W.
Brayden W.
Arrived on site for control board replacement and QC. Replaced control board under warranty. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and found no issues. Assisted homeowner in connecting to thermostat to Wi-Fi and to the app. Also showed homeowner how to replace filter. Discussed surge protection with homeowner not interested at this time. System in good working order upon departure. Thank you for your time.
Allen, TX 75002
Allen, TX - Arrived on site for control board replacement and QC. Replaced control board under warranty. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and found no issues. Assisted homeowner in connecting to thermostat to Wi-Fi and to the app. Also showed homeowner how to replace filter. Discussed surge protection with homeowner not interested at this time. System in good working order upon departure. Thank you for your time.
Allen, TX - Arrived on site for control board replacement and QC. Replaced control board under warranty. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and found no issues. Assisted homeowner in connecting to thermostat to Wi-Fi and to the app. Also showed homeowner how to replace filter. Discussed surge protection with homeowner not interested at this time. System in good working order upon departure. Thank you for your time.
Brayden W.
Brayden W.
Arrived on site for no heat on 2025 Trane furnace. Turned on heat in order to test unit. Blower and inducer were running, however the heating cycle would go no further. Checked all plugs and connection and found nothing of concern. Tested rollout switches, temp limit switch and blower sensors for resistance and found no issues. Found E04 error on control board. Measured voltage on pressure switch and measured nothing. Tested voltage on plug into board from pressure switch and measured nothing. Also found bent burner and I was able to bend it back into shape. However it is not perfect and will need to be replaced. Spoke with Trane tech support and he advised me that the control board was bad and would need to be replaced. Upon reassembling the unit and powering on the unit completed the heating cycle without issue. This leads me to believe it is an intermittent issue that could come back. To be proactive about the situation we will go ahead and replace the control board to prevent futur
Allen, TX 75002
Allen, TX - Arrived on site for no heat on 2025 Trane furnace. Turned on heat in order to test unit. Blower and inducer were running, however the heating cycle would go no further. Checked all plugs and connection and found nothing of concern. Tested rollout switches, temp limit switch and blower sensors for resistance and found no issues. Found E04 error on control board. Measured voltage on pressure switch and measured nothing. Tested voltage on plug into board from pressure switch and measured nothing. Also found bent burner and I was able to bend it back into shape. However it is not perfect and will need to be replaced. Spoke with Trane tech support and he advised me that the control board was bad and would need to be replaced. Upon reassembling the unit and powering on the unit completed the heating cycle without issue. This leads me to believe it is an intermittent issue that could come back. To be proactive about the situation we will go ahead and replace the control board to prevent futur
Allen, TX - Arrived on site for no heat on 2025 Trane furnace. Turned on heat in order to test unit. Blower and inducer were running, however the heating cycle would go no further. Checked all plugs and connection and found nothing of concern. Tested rollout switches, temp limit switch and blower sensors for resistance and found no issues. Found E04 error on control board. Measured voltage on pressure switch and measured nothing. Tested voltage on plug into board from pressure switch and measured nothing. Also found bent burner and I was able to bend it back into shape. However it is not perfect and will need to be replaced. Spoke with Trane tech support and he advised me that the control board was bad and would need to be replaced. Upon reassembling the unit and powering on the unit completed the heating cycle without issue. This leads me to believe it is an intermittent issue that could come back. To be proactive about the situation we will go ahead and replace the control board to prevent futur
Shelby S.
Shelby S.
Upon arrival, I found that it was 66 degrees in the gym area with the thermostat set to 74. I proceed to test the system is cooling and found the blower motor was no longer turning on. I verified I was getting voltage on the fan wire. This indicated a failure with the blower control/motor. We will reach out the trane to verify warranty tomorrow and produce pricing for the repair. The issue is not related to the previous work provided.
Allen, TX 75013
Allen, TX - Upon arrival, I found that it was 66 degrees in the gym area with the thermostat set to 74. I proceed to test the system is cooling and found the blower motor was no longer turning on. I verified I was getting voltage on the fan wire. This indicated a failure with the blower control/motor. We will reach out the trane to verify warranty tomorrow and produce pricing for the repair. The issue is not related to the previous work provided.
Allen, TX - Upon arrival, I found that it was 66 degrees in the gym area with the thermostat set to 74. I proceed to test the system is cooling and found the blower motor was no longer turning on. I verified I was getting voltage on the fan wire. This indicated a failure with the blower control/motor. We will reach out the trane to verify warranty tomorrow and produce pricing for the repair. The issue is not related to the previous work provided.
Shelby S.
Shelby S.
Upon arrival I found that both system’s drains are tied together. This resulted in the float switches to become tripped and shut off the cooling. I reached out to Brandon and received approval to clear the drains. I took videos, cleared the drain, and tested it afterwards. The systems are back to cooling properly. I was instructed to invoice it and send it to Brandon.
Allen, TX 75013
Allen, TX - Upon arrival I found that both system’s drains are tied together. This resulted in the float switches to become tripped and shut off the cooling. I reached out to Brandon and received approval to clear the drains. I took videos, cleared the drain, and tested it afterwards. The systems are back to cooling properly. 
I was instructed to invoice it and send it to Brandon.
Allen, TX - Upon arrival I found that both system’s drains are tied together. This resulted in the float switches to become tripped and shut off the cooling. I reached out to Brandon and received approval to clear the drains. I took videos, cleared the drain, and tested it afterwards. The systems are back to cooling properly. 
I was instructed to invoice it and send it to Brandon.
Jacob P.
Jacob P.
Spoke with client over the phone and created two estimates for 3 ton gas systems. I emailed both estimates to Heather. Her husband recently had surgery and did not want to schedule an in home visit at this time.
Allen, TX 75002
Shelby S.
Shelby S.
Homeowner spoke about uncomfortable areas on the upstairs. I checked the system for dampers and found none present. I presented a price to install dampers and balance the air. Customer approved and I collected a deposit for the work. The work is scheduled for 10/21/2025 with the arrival time of 8am to 9am.
Allen, TX 75002
Brayden W.
Brayden W.
We performed a 3 heating maintenances on 2015 gas systems. We checked amps, filters, electrical, gas valves, cleanliness, flame sensors, igniters, and safeties. We noticed some potential issues in all 3 systems. All 3 blowers wheels have some build up present. This hard strain to the motors and control modules. 2 of the outdoor units have heavy build up on the coil. This leads to strain on all electrical aspects of the outdoor units. The air quality check showed high particles and chemicals. We noticed a duct with a kink in it potentially causes poor air flow. The units are not currently protected from surges. We presented options to address these noticed potential issues. The customer declined all options at the time of service, and we emailed them out to the customer.
Allen, TX 75013
Allen, TX - We performed a 3 heating maintenances on 2015 gas systems. We checked amps, filters, electrical, gas valves, cleanliness, flame sensors, igniters, and safeties. We noticed some potential issues in all 3 systems. All 3 blowers wheels have some build up present. This hard strain to the motors and control modules. 2 of the outdoor units have heavy build up on the coil. This leads to strain on all electrical aspects of the outdoor units. The air quality check showed high particles and chemicals. We noticed a duct with a kink in it potentially causes poor air flow. The units are not currently protected from surges. We presented options to address these noticed potential issues. The customer declined all options at the time of service, and we emailed them out to the customer.
Allen, TX - We performed a 3 heating maintenances on 2015 gas systems. We checked amps, filters, electrical, gas valves, cleanliness, flame sensors, igniters, and safeties. We noticed some potential issues in all 3 systems. All 3 blowers wheels have some build up present. This hard strain to the motors and control modules. 2 of the outdoor units have heavy build up on the coil. This leads to strain on all electrical aspects of the outdoor units. The air quality check showed high particles and chemicals. We noticed a duct with a kink in it potentially causes poor air flow. The units are not currently protected from surges. We presented options to address these noticed potential issues. The customer declined all options at the time of service, and we emailed them out to the customer.
Shelby S.
Shelby S.
Upon arrival, I found that the sensor needing batteries was causing the error codes. After addressing that, I found that the capacitor was reading 6/70. This resulted in the compressor not turning on. I hooked a capacitor up and began testing. I determined that the unit was in need of a hard start kit, as well. I presented options to address these issues. The system is cooling upon departure.
Allen, TX 75002
Allen, TX - Upon arrival, I found that the sensor needing batteries was causing the error codes. After addressing that, I found that the capacitor was reading 6/70. This resulted in the compressor not turning on. I hooked a capacitor up and began testing. I determined that the unit was in need of a hard start kit, as well. I presented options to address these issues. The system is cooling upon departure.
Allen, TX - Upon arrival, I found that the sensor needing batteries was causing the error codes. After addressing that, I found that the capacitor was reading 6/70. This resulted in the compressor not turning on. I hooked a capacitor up and began testing. I determined that the unit was in need of a hard start kit, as well. I presented options to address these issues. The system is cooling upon departure.
Matthew C.
Matthew C.
Performed a 3 commercial system spring maintenance. Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,condenser fan capacitor on both units are failing,,7.5/5.0 MFD ,, they need to be replaced as soon as possible,,, we also recommended to install a hard start kit on both units , it will extend the life and stress on the compressor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter,,filters are very dirty,customer will replace them later. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil,,unit #2 is extremely dirty, had 11 degrees split differential, evaporator needs to get cleaned as soon as possible. 12. Inspected blower motor/ blower wheel,,,unit #2 is extremely dirty, h
Allen, TX 75013
Allen, TX - Performed a 3 commercial system spring maintenance. Tasks performed.
 1. Visually inspected condenser coil for debris/ dirty. 
2. Inspected condenser fan motor.
3. Inspected condenser fan blades. 
4. Inspected/ cleaned wiring connections. 
5. Tested compressor/ condenser fan motor capacitor,,,condenser fan capacitor on both units are failing,,7.5/5.0 MFD ,, they need to be replaced as soon as possible,,, we also recommended to install a hard start kit on both units , it will extend the life and stress on the compressor. 
6. Checked refrigerant pressures. 
7. Checked compressor amp draw. 
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter,,filters are very dirty,customer will replace them later.
10. Inspected return plenum for debris/ dirty. 
11. Inspected evaporator coil,,unit #2 is extremely dirty, had 11 degrees split differential, evaporator needs to get cleaned as soon as possible.
 12. Inspected blower motor/ blower wheel,,,unit #2 is extremely dirty, h
Allen, TX - Performed a 3 commercial system spring maintenance. Tasks performed.
 1. Visually inspected condenser coil for debris/ dirty. 
2. Inspected condenser fan motor.
3. Inspected condenser fan blades. 
4. Inspected/ cleaned wiring connections. 
5. Tested compressor/ condenser fan motor capacitor,,,condenser fan capacitor on both units are failing,,7.5/5.0 MFD ,, they need to be replaced as soon as possible,,, we also recommended to install a hard start kit on both units , it will extend the life and stress on the compressor. 
6. Checked refrigerant pressures. 
7. Checked compressor amp draw. 
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter,,filters are very dirty,customer will replace them later.
10. Inspected return plenum for debris/ dirty. 
11. Inspected evaporator coil,,unit #2 is extremely dirty, had 11 degrees split differential, evaporator needs to get cleaned as soon as possible.
 12. Inspected blower motor/ blower wheel,,,unit #2 is extremely dirty, h
Jacob P.
Jacob P.
We installed the system, flushed the line, and and put a new thermostat.
Allen, TX 75002
Allen, TX - We installed the system, flushed the line, and and put a new thermostat.
Allen, TX - We installed the system, flushed the line, and and put a new thermostat.
Jacob P.
Jacob P.
I arrived at our clients home for a second opinion regarding their HVAC equipment. I met with Shonna and she educated me regarding the situation. She showed me her thermostat and attic access and I proceeded to inspect the equipment. I did ask for permission to also diagnose the system to potentially provide a fix. I found the system to be completely empty on refrigerant and other minor issues related to ductwork. I found the system to have double filter (one in the ceiling and another in the attic). I did not create an estimate for repairs due to the age and obvious signs that the system has a significant refrigerant leak. I did created 2 estimates options and will be sending them to both via email. I also addressed the email Mr. Brown sent to us 1. Outdoor Condenser Unit (brand, model, SEER2 rating, and tonnage recommended) - American Standard 15.2 SEER 5 Ton Conventional split system 2. Indoor Coil / Evaporator (brand/model, compatibility with condenser)- 5 ton Matching American
Allen, TX 75002
Allen, TX - I arrived at our clients home for a second opinion regarding their HVAC equipment. I met with Shonna and she educated me regarding the situation. She showed me her thermostat and attic access and I proceeded to inspect the equipment. I did ask for permission to also diagnose the system to potentially provide a fix.
I found the system to be completely empty on refrigerant and other minor issues related to ductwork. I found the system to have double filter (one in the ceiling and another in the attic). I did not create an estimate for repairs due to the age and obvious signs that the system has a significant refrigerant leak. I did created 2 estimates options and will be sending them to both via email. I also addressed the email Mr. Brown sent to us 


1. Outdoor Condenser Unit (brand, model, SEER2 rating, and tonnage recommended) - American Standard 15.2 SEER 5 Ton Conventional split system
2. Indoor Coil / Evaporator (brand/model, compatibility with condenser)- 5 ton Matching American
Allen, TX - I arrived at our clients home for a second opinion regarding their HVAC equipment. I met with Shonna and she educated me regarding the situation. She showed me her thermostat and attic access and I proceeded to inspect the equipment. I did ask for permission to also diagnose the system to potentially provide a fix.
I found the system to be completely empty on refrigerant and other minor issues related to ductwork. I found the system to have double filter (one in the ceiling and another in the attic). I did not create an estimate for repairs due to the age and obvious signs that the system has a significant refrigerant leak. I did created 2 estimates options and will be sending them to both via email. I also addressed the email Mr. Brown sent to us 


1. Outdoor Condenser Unit (brand, model, SEER2 rating, and tonnage recommended) - American Standard 15.2 SEER 5 Ton Conventional split system
2. Indoor Coil / Evaporator (brand/model, compatibility with condenser)- 5 ton Matching American

Your High Efficiency

Experts