Allen, TX -AC and Heating Repair Service

HVAC Contractor near Allen TX

Air conditioning is a huge part of life in Allen TX and the surrounding Texas communities, and that means you need great heating and air conditioning repair service. That's why we've made it our mission at Adon Complete Air Conditioning & Heating to make high-efficiency HVAC unit systems affordable and accessible for home and business owners in Allen.

Heating & AC Repair Service near Allen TX

Whether you need residential air conditioning repair or a new HVAC system installed for your existing heating and air conditioning systems, our comfort specialists can help.

We invite you to read some of our reviews below from neighbors in the Allen, TX area!

We understand that every home and business in Allen, TX has unique heating and cooling needs, which is why we offer a full range of residential and light commercial HVAC services.

We install, repair and maintain:

  • Air conditioners
  • Heat pumps
  • Furnaces
  • Ductless mini-splits
  • Indoor air quality systems
  • Thermostats

All of our HVAC unit installations are backed by a ten-year labor warranty and we offer a two-year heating and air conditioning maintenance plan.

We also offer 24/7 emergency air conditioning repair service throughout the summer months to keep your family in Allen cool and protected.

Adon Complete Air Conditioning and Heating  is Your Local Air Conditioning & Heating Repair Service Provider

Families in Allen, TX know how important it is to take action right away on air conditioning repair and service. Turn to our reliable, dedicated comfort specialists for the HVAC services you need and the outstanding customer service you deserve.

Whether you need a new system or service for your existing unit, contact us online or give us a call at (903) 482-4900 today to schedule your service in Allen.

Schedule Service Today. We Treat You Like Family!

Recent Jobs and Reviews in Allen, TX

Rated 4.7 out of 5 stars based on 6 customer reviews

Customers say: # Review Sentiment Analysis The reviews reflect an overwhelmingly positive sentiment toward the company's HVAC services. Customers consistently praise the technicians for being knowledgeable, professional, and thorough in their work. Many reviewers highlight the clear communication provided by staff, noting how well technicians explained system issues and maintenance procedures. The service quality is frequently described as "excellent" with multiple mentions of staff going "above and beyond" expectations. Customers appreciate the technicians' attention to detail, honesty, and courteous demeanor. The company appears to have built strong customer loyalty, with several reviewers mentioning they are long-term customers or would highly recommend the service to others. The overall tone is decidedly positive, with recurring themes of professionalism, reliability, helpfulness, and quality workmanship. Customers also value the maintenance programs offered and the comprehensive nature of the service visits.

Reviews

AC
Great guy
Carter - Allen, TX 75002
Great Service
He is very polite and patient. Explains all the options I have and provided great service. Thanks!
Hui - Allen, TX 75013
Service was great
Great
Mickel - Allen, TX 75002
Great Service
Very Professional
Eduardo - Allen, TX 75002
Excellent service, affordable, professional
Our A/C broke when the weather started to get hot. We called Adon Complete, and Charles came. He was experienced and professional. He and his crew replaced our 20-year old unit, and our system is up and running just in time for summer. I would recommend Adon Complete for all my friends and neighbors.
Kent - Allen, TX 75002
Very friendly
Mary - Allen, TX 75002

Job Locations

Skylar M.
Skylar M.
2 system AC maintenance. Replaced filter provided by customer. Checked amp draw on blower motors. Checked operation of drain lines and treated them with drain solution. Drain pan for upstairs system is rusted and should be replaced as soon as possible. Upstairs system does not have safety float switch, recommend adding one to prevent water from overflowing and causing ceiling damage. Measured temperature drop across system, getting 19-20° for both units. Measured amp draw on compressors and condenser fan motors. Capacitor for upstairs system is very low and needs to be replaced. Contactors and capacitor for downstairs system are within acceptable tolerance. Cleaned condenser coil for downstairs with water. Performed chemical coil cleaning on upstairs system and installed capacitor. Cleared drain line for upstairs system.
Allen, TX 75002
Allen, TX - 2 system AC maintenance. Replaced filter provided by customer. Checked amp draw on blower motors. Checked operation of drain lines and treated them with drain solution. Drain pan for upstairs system is rusted and should be replaced as soon as possible. Upstairs system does not have safety float switch, recommend adding one to prevent water from overflowing and causing ceiling damage. Measured temperature drop across system, getting 19-20° for both units. Measured amp draw on compressors and condenser fan motors.  Capacitor for upstairs system is very low and needs to be replaced. Contactors and capacitor for downstairs system are within acceptable tolerance. Cleaned condenser coil for downstairs with water. 

Performed chemical coil cleaning on upstairs system and installed capacitor. Cleared drain line for upstairs system.
Allen, TX - 2 system AC maintenance. Replaced filter provided by customer. Checked amp draw on blower motors. Checked operation of drain lines and treated them with drain solution. Drain pan for upstairs system is rusted and should be replaced as soon as possible. Upstairs system does not have safety float switch, recommend adding one to prevent water from overflowing and causing ceiling damage. Measured temperature drop across system, getting 19-20° for both units. Measured amp draw on compressors and condenser fan motors.  Capacitor for upstairs system is very low and needs to be replaced. Contactors and capacitor for downstairs system are within acceptable tolerance. Cleaned condenser coil for downstairs with water. 

Performed chemical coil cleaning on upstairs system and installed capacitor. Cleared drain line for upstairs system.
Shelby S.
Shelby S.
We performed a 5 system cooling maintenance on gas systems. We checked amps, capacitors, filters, electrical, drains, and cleanliness. During our thorough evaluation, we discovered that 4 of the 5 outdoor units were full of cottonwood. We got approval to provided chemical cleanings during the visit. The dining room 1 system has a 35/5 capacitor that is out of range and will fail likely before the end of the summer. The main system has a weak 45/5 capacitor, also. We noticed the gym unit was having an issue. The issue was a loose wire at the control board. The systems are cooling upon departure. We emailed the other options and the invoice for the cleanings
Allen, TX 75013
Allen, TX - We performed a 5 system cooling maintenance on gas systems. We checked amps, capacitors, filters, electrical, drains, and cleanliness. During our thorough evaluation, we discovered that 4 of the 5 outdoor units were full of cottonwood. We got approval to provided chemical cleanings during the visit. The dining room 1 system has a 35/5 capacitor that is out of range and will fail likely before the end of the summer. The main system has a weak 45/5 capacitor, also. We noticed the gym unit was having an issue. The issue was a loose wire at the control board. The systems are cooling upon departure. We emailed the other options and the invoice for the cleanings
Allen, TX - We performed a 5 system cooling maintenance on gas systems. We checked amps, capacitors, filters, electrical, drains, and cleanliness. During our thorough evaluation, we discovered that 4 of the 5 outdoor units were full of cottonwood. We got approval to provided chemical cleanings during the visit. The dining room 1 system has a 35/5 capacitor that is out of range and will fail likely before the end of the summer. The main system has a weak 45/5 capacitor, also. We noticed the gym unit was having an issue. The issue was a loose wire at the control board. The systems are cooling upon departure. We emailed the other options and the invoice for the cleanings
Shelby S.
Shelby S.
Performed 2 system cooling maintenance and dryer vent cleaning. I checked amps, capacitors, filters, electrical, drains, and cleanliness. The systems are cooling well. I offered water safety switches and surge protection again during the visit and emailed it Mr. Carter. Systems are cooling upon departure.
Allen, TX 75002
Allen, TX - Performed 2 system cooling maintenance and dryer vent cleaning. I checked amps, capacitors, filters, electrical, drains, and cleanliness. The systems are cooling well. I offered water safety switches and surge protection again during the visit and emailed it Mr. Carter. Systems are cooling upon departure.
Allen, TX - Performed 2 system cooling maintenance and dryer vent cleaning. I checked amps, capacitors, filters, electrical, drains, and cleanliness. The systems are cooling well. I offered water safety switches and surge protection again during the visit and emailed it Mr. Carter. Systems are cooling upon departure.
Jesse V.
Jesse V.
I found capacitor was dead not allowing the compressor to start. We replaced and ensured the system began to cool again. With the customer doing a compressor replacement yesterday, we replaced the capacitor complimentary.
Allen, TX 75002
Allen, TX - I found capacitor was dead not allowing the compressor to start. We replaced and ensured the system began to cool again. With the customer doing a compressor replacement yesterday, we replaced the capacitor complimentary.
Allen, TX - I found capacitor was dead not allowing the compressor to start. We replaced and ensured the system began to cool again. With the customer doing a compressor replacement yesterday, we replaced the capacitor complimentary.
Brayden W.
Brayden W.
Arrived on site, found capacitor bloated and rusted. Measured capacitance and found none. This confirms capacitor is entirely failed and must be replaced for unit for function. Outdoor high voltage whip has a large hole in it and wire jackets are beginning to take damage from the sun. Outdoor coils are completely blanketed. This restricts airflow and produces a lot of stress on the refrigerant cycle. Homeowner approved capacitor replacement and outdoor chemical cleaning. Performed capacitor installation and condenser chemical cleaning. Homeowner stated inspector found that there was no sediment trap on the gas line. Provided estimates for all of the above issues. Measured 20 degree split from supply to return. System running upon departure.
Allen, TX 75013
Allen, TX - Arrived on site, found capacitor bloated and rusted. Measured capacitance and found none. This confirms capacitor is entirely failed and must be replaced for unit for function. Outdoor high voltage whip has a large hole in it and wire jackets are beginning to take damage from the sun. Outdoor coils are completely blanketed. This restricts airflow and produces a lot of stress on the refrigerant cycle. Homeowner approved capacitor replacement and outdoor chemical cleaning. Performed capacitor installation and condenser chemical cleaning. Homeowner stated inspector found that there was no sediment trap on the gas line. Provided estimates for all of the above issues. Measured 20 degree split from supply to return. System running upon departure.
Allen, TX - Arrived on site, found capacitor bloated and rusted. Measured capacitance and found none. This confirms capacitor is entirely failed and must be replaced for unit for function. Outdoor high voltage whip has a large hole in it and wire jackets are beginning to take damage from the sun. Outdoor coils are completely blanketed. This restricts airflow and produces a lot of stress on the refrigerant cycle. Homeowner approved capacitor replacement and outdoor chemical cleaning. Performed capacitor installation and condenser chemical cleaning. Homeowner stated inspector found that there was no sediment trap on the gas line. Provided estimates for all of the above issues. Measured 20 degree split from supply to return. System running upon departure.
Clever M.
Clever M.
Completed service call. Customer indicated there was a power outage and unit stopped working last night. Found compressor was tripping breaker. Washed outside coils and restarted unit. Compressor intermittently tripping breaker. Found outside coils very dirty. Washed as courtesy. Offered and accepted membership. Emailed quote to have compressor replaced under warranty. Left unit running and cooling for now.
Allen, TX 75002
Allen, TX - Completed service call. Customer indicated there was a power outage and unit stopped working last night. Found compressor was tripping breaker. Washed outside coils and restarted unit. Compressor intermittently tripping breaker. Found outside coils very dirty. Washed as courtesy. Offered and accepted membership. Emailed quote to have compressor replaced under warranty. Left unit running and cooling for now.
Allen, TX - Completed service call. Customer indicated there was a power outage and unit stopped working last night. Found compressor was tripping breaker. Washed outside coils and restarted unit. Compressor intermittently tripping breaker. Found outside coils very dirty. Washed as courtesy. Offered and accepted membership. Emailed quote to have compressor replaced under warranty. Left unit running and cooling for now.
Clever M.
Clever M.
Completed 1 system cooling tune up. Checked all critical components. Tested motor amp draw, capacitor, contactor, filter and washed outside coils. Checked customer repair on distribution box, well done. Found no air leaks. Unit operating normally at this time. Discussed possible upgrade to duct work for better air flow.
Allen, TX 75002
Allen, TX - Completed 1 system cooling tune up. Checked all critical components. Tested motor amp draw, capacitor, contactor, filter and washed outside coils.  Checked customer repair on distribution box, well done. Found no air leaks. Unit operating normally at this time. Discussed possible upgrade to duct work for better air flow.
Allen, TX - Completed 1 system cooling tune up. Checked all critical components. Tested motor amp draw, capacitor, contactor, filter and washed outside coils.  Checked customer repair on distribution box, well done. Found no air leaks. Unit operating normally at this time. Discussed possible upgrade to duct work for better air flow.
Shelby S.
Shelby S.
I performed a single cooling maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and air quality. During my thorough evaluation, I discovered that the indoor unit needs cleaning. I discovered a temperature split that is okay but can be improved with the cleanings. The air quality test indicated that the home has high chemical and particulate content. The indoor unit is forming growth, as well. I presented options to address these concerns at the time of service.
Allen, TX 75002
Allen, TX - I performed a single cooling maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and air quality. During my thorough evaluation, I discovered that the indoor unit needs cleaning. I discovered a temperature split that is okay but can be improved with the cleanings. The air quality test indicated that the home has high chemical and particulate content. The indoor unit is forming growth, as well. I presented options to address these concerns at the time of service.
Allen, TX - I performed a single cooling maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and air quality. During my thorough evaluation, I discovered that the indoor unit needs cleaning. I discovered a temperature split that is okay but can be improved with the cleanings. The air quality test indicated that the home has high chemical and particulate content. The indoor unit is forming growth, as well. I presented options to address these concerns at the time of service.
Matthew C.
Matthew C.
Preformed single system maintenance on a 2020 gas trane system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I tested and flushed drain lines with water and total c at today's visit. I changed the filter for the client 20x25x1. Client has the capability to change to a 20x25 x4. Provided estimates to have that upgraded to the aprilaire 210. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed neither inside or outside units have surge protectors. Unit is cooling upon departure.
Allen, TX 75002
Allen, TX - Preformed single system maintenance on a 2020 gas trane system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I tested and flushed drain lines with water and total c at today's visit. I changed the filter for the client 20x25x1. Client has the capability to change to a 20x25 x4. Provided estimates to have that upgraded to the aprilaire 210. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed neither inside or outside units have surge protectors. Unit is cooling upon departure.
Allen, TX - Preformed single system maintenance on a 2020 gas trane system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I tested and flushed drain lines with water and total c at today's visit. I changed the filter for the client 20x25x1. Client has the capability to change to a 20x25 x4. Provided estimates to have that upgraded to the aprilaire 210. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed neither inside or outside units have surge protectors. Unit is cooling upon departure.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Downstairs condenser is starting to show signs of oxidation. Advised condenser cleaning, not very urgent at
Allen, TX 75013
Allen, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Downstairs condenser is starting to show signs of oxidation. Advised condenser cleaning, not very urgent at
Allen, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Downstairs condenser is starting to show signs of oxidation. Advised condenser cleaning, not very urgent at
Matthew C.
Matthew C.
Preformed 3 system maintenance on 3 communicating gas trane systems. I tested all electric components on each system all tested within manufacturer specifications. I noticed on the upstairs and downstair system drain lines were extremely clogged. Water was spilling on the decking of the attic. Spoke to client about the issue and was asked to leave when I mentioned that I would have to charge to clear both drain lines before I could finish the maintenance. All outside units were testing within range and cooling upon departure. Filter sizes 20x25x4 aprilaire 210.
Allen, TX 75013
Allen, TX - Preformed 3 system maintenance on 3 communicating gas trane systems. I tested all electric components on each system all tested within manufacturer specifications. I noticed on the upstairs and downstair system drain lines were extremely clogged. Water was spilling on the decking of the attic. Spoke to client about the issue and was asked to leave when I mentioned that I would have to charge to clear both drain lines before I could finish the maintenance. All outside units were testing within range and cooling upon departure. Filter sizes 20x25x4 aprilaire 210.
Allen, TX - Preformed 3 system maintenance on 3 communicating gas trane systems. I tested all electric components on each system all tested within manufacturer specifications. I noticed on the upstairs and downstair system drain lines were extremely clogged. Water was spilling on the decking of the attic. Spoke to client about the issue and was asked to leave when I mentioned that I would have to charge to clear both drain lines before I could finish the maintenance. All outside units were testing within range and cooling upon departure. Filter sizes 20x25x4 aprilaire 210.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Upstairs amana condenser is covered in bushes. This can cause the coils to become dirty faster and puts stre
Allen, TX 75002
Allen, TX - 1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Upstairs amana condenser is covered in bushes. This can cause the coils to become dirty faster and puts stre
Allen, TX - 1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Upstairs amana condenser is covered in bushes. This can cause the coils to become dirty faster and puts stre
Matthew C.
Matthew C.
Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure. Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Allen, TX 75002
Allen, TX - Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. 

Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure.
Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Allen, TX - Upon arrival system was not working. I proceeded to the attic where I found a blown 3 amp fuse. I replaced the fuse and removed the metal covering from the housing of the air handler board. The fuse didn’t blow and unit continued to work normally after removing the metal off the wires. I repaired wires also. 

Preformed cooling maintenance on the system. The unit could benefit from having a deep cleaning done on all the major components in the attic. There is dust build up on each component and the drain lines aren’t draining well, all electrical tested within manufacturer specifications after repair, I replaced filter for the client. 20x25x4. On the outside unit all electrical tested within manufacturer specifications. Except for the capacitor it was reading 30/45. It is failing. But is still operating the unit. I rinsed the outside unit with water. Unit was cooling upon departure.
Found blown fuse upon arrival. Found that the metal door covering the board on the air handler on the bl
Shelby S.
Shelby S.
I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Allen, TX 75013
Allen, TX - I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Allen, TX - I performed 3 cooling maintenances on gas systems. The upstairs unit has a 2015 furnace with 2024 cooling components. The other 2 systems are from completely from 2015. I checked amps, capacitors, filters, drains, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered water in the downstairs systems drain pan. I investigated and discovered that the sink is clogged causing water to back flow. I informed the customer of the plumbing issue. I noticed that none of the equipment has surge protection. These offer a safety net from a variety of electrical surges caused by blackouts, brown outs, and even proximity lightning strikes. The blower wheel all need cleanings. This will remove drag on the motors preserving life span, and restoring performance. The outdoor unit got washed today, but there are cases that water is not enough. It is advised that all of the outdoor units be chemically washed. This will reduce strain on the outdoor electrical and increase perform
Brayden W.
Brayden W.
Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Allen, TX 75013
Allen, TX -  Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Allen, TX -  Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Added 14 oz of 454b. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Brayden W.
Brayden W.
Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Allen, TX 75013
Allen, TX - Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Allen, TX - Sheathed and sealed all outdoor units to prevent UV damage and breaks in the exposed wire. Replaced blower motor and high limit switch on dining room 1 located in storage room on left unit. Replaced capacitor for dining room 2 located in storage room on right. Replaced blower motor for workout room and high limit in atrium. Locking caps were not installed at this time. Advised customer that we would be returning likely today to install the locking caps. Tested high limit switches and found no further issues at this time. Units in good working order upon departure.
Matthew C.
Matthew C.
Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Allen, TX 75013
Allen, TX - Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed  they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Allen, TX - Preformed single system maintenance on a 2009 Trane furnace. I tested all electrical components and safeties. They all tested within manufacturer specifications. I tested the drain lines I noticed  they are draining extremely slow. Also I noticed the blower and ducts were extremely dusty as well. I proceeded to the outside unit where I visually inspected the unit for cleanliness. I noticed that the condenser coil could benefit from a deep cleaning. Also the unit isn’t protected by any type of surge protection. Unit was heating upon departure.
Matthew C.
Matthew C.
Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Allen, TX 75013
Allen, TX - Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Allen, TX - Preformed single system heating maintenance on a gas furnace. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client stated he would change the filters, he needs to order them. I visually inspected the outside unit and the unit was in good working condition. Unit was heating upon departure.
Matthew C.
Matthew C.
Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Allen, TX 75013
Allen, TX - Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Allen, TX - Preformed 3 system heating maintenance. I tested all electrical components on inside units. All tested within manufacturer specifications. I was able to change 2/3 filters. Filter size is 20x25x4 Aprilaire 210. The filter that needs to be changed is the upstairs filter. I visually inspected the outside units all were in good working order.
Brayden W.
Brayden W.
Performed maintenance on 5 carrier furnaces 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Dining room 1 - storage left The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Allen, TX 75013
Allen, TX - Performed maintenance on 5 carrier furnaces 

 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Dining room 1 - storage left 
The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Allen, TX - Performed maintenance on 5 carrier furnaces 

 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Dining room 1 - storage left 
The blower motor is leaking oil. This is a clear indication that the motor is failing and will likely lock up soon. The high limit switch is turning the unit off before max temperature is reached. This means the switch is faulty an
Jesse V.
Jesse V.
I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Allen, TX 75002
Allen, TX - I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Allen, TX - I performed heating maintenances on 2 - 2015 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Jesse and I investigated the air flow issue and gathered data to take back to the office to find a route to a solution. I noticed that the blower wheels are becoming dirty. This can be slowed down by upgrading the filtration to a filter that provides a complete seal. I observed that the drain lines do not have a primary water safety switch. These allow us to protect your home from water damage from clogged drain lines. The furnaces currently don’t have surge protection. To minimize damage from power fluctuations, we advise adding a safety need go ensure the units are safe.
Matthew C.
Matthew C.
Performed a complete heating system maintenance and inspection. 2025 Gas system. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F. Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”. I visually inspected the outdoor unit, The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.
Allen, TX 75002
Allen, TX - Performed a complete heating system maintenance and inspection.  2025 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F.

Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Allen, TX - Performed a complete heating system maintenance and inspection.  2025 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 74°F; supply air temperature measured at 128°F.

Air filter did not need to be changed at this time, filter needs to be changed between March-April;filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition. Outdoor unit could benefit from having surge protection installed. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Allen, TX 75002
Allen, TX - I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Allen, TX - I performed a single heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical connections, cleanliness, and safeties. Also, I removed leaves from the top and around the sides of the outdoor unit. I failed to take a picture afterwards. I discovered that the blower has a substantial amount of build up present. This causes higher electric bills and added wear on the motor. I noticed that the unit does not have surge protection either. I presented solutions to the customer, and he declined at the time of service. The system is heating upon departure.
Shelby S.
Shelby S.
I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Allen, TX 75002
Allen, TX - I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Allen, TX - I performed a single system heating maintenance on a heat pump system. The indoor is from 2021 and the outdoor is from 2024. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I discovered the capacitor is beginning to lose its charge. I provided an option to address it now before it gets worse. System has surge protection, hard start kit, u/v stick, and Apco-x. System is heating upon departure.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.
Allen, TX 75002
Allen, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
 
Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.
Allen, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
 
Advised homeowner we are running a special on surge protectors and they could benefit from additional protection as they said the power is shaky at times. Unit in good working order upon departure.

Your High Efficiency

Experts