Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in November 2026.

The 10 customer reviews shown here average 4.9 out of 5.

The most recent job was on November 9, 2026.

Adon Complete Air Conditioning and Heating has completed 587 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Reviews

Great service
Charles explained everything thoroughly and walked me through repair.
Jennifer - Anna, TX 75409
Outstanding service
Technician was prompt and polite. He seemed to be very knowledgeable and had no issues answering my questions about the unit. Very good experience that will have us coming back for future service needs.
Anthony - Anna, TX 75409
Great service
Natalie - Anna, TX 75409
Great Service
Outstanding work and very professional.
Eric - Anna, TX 75409
Maintenance
Hayes - Anna, TX 75409
Great Service
Mona - Anna, TX 75409
Excellent Customer Service
Reliable, trustworthy, prompt and professional. Excellent customer service.
Shirley - Anna, TX 75409
So professional
They were quick to respond and so professional. I highly recommend!
Kent - Anna, TX 75409
Excellent Service
They responded quickly, were very professional, fixed the problem, and the pricing was reasonable.
Lauren - Anna, TX 75409
Good service
On time, fair price, tech found the problem quickly.
Chris - Anna, TX 75409

Job Locations

Skylar M.
Skylar M.
1 system heating maintenance. Replaced filter provided by tenant. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time. System has zoning for upstairs and downstairs. Zone control motor for downstairs has failed. Motor is recieving correct voltage from board but is not closing. Sent estimate to replace motor. Contactor for outside is pitting at the connections. It will weld itself closed which can cause damage to the compressor. Recommend replacing it before it fails completely.
Anna, TX 75409
Anna, TX - 1 system heating maintenance. Replaced filter provided by tenant. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time. 

System has zoning for upstairs and downstairs. Zone control motor for downstairs has failed. Motor is recieving correct voltage from board but is not closing. Sent estimate to replace motor.

Contactor for outside is pitting at the connections. It will weld itself closed which can cause damage to the compressor. Recommend replacing it before it fails completely.
Anna, TX - 1 system heating maintenance. Replaced filter provided by tenant. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time. 

System has zoning for upstairs and downstairs. Zone control motor for downstairs has failed. Motor is recieving correct voltage from board but is not closing. Sent estimate to replace motor.

Contactor for outside is pitting at the connections. It will weld itself closed which can cause damage to the compressor. Recommend replacing it before it fails completely.
Skylar M.
Skylar M.
Customer is having issues with front bedroom not staying conditioned like the rest of the house. Customer keeps doors closed because of kids in the house. With no return in the bedroom, the air cannot be cycled through properly. Bedroom also has three of the four walls exposed to the exterior which can prevent the room from feeling the same temperature as the rest of the house. Adjusted the damper for the supply run that goes into the living room. This allowed a little more air to be pushed into the problem room. With the doors being closed all the time, recommend installing a return vent in the room as well to help cycle the stagnant air. This will allow the air that is trapped to move through the system and be conditioned. Recommend a duct cleaning as it has not been done since the house was built. There is quite a bit of dirt that has collected in the ductwork. Capacitor for outside unit needs to be replaced. It is well out of acceptable range and will fail soon.
Anna, TX 75409
Anna, TX - Customer is having issues with front bedroom not staying conditioned like the rest of the house. Customer keeps doors closed because of kids in the house. With no return in the bedroom, the air cannot be cycled through properly. Bedroom also has three of the four walls exposed to the exterior which can prevent the room from feeling the same temperature as the rest of the house. 

Adjusted the damper for the supply run that goes into the living room. This allowed a little more air to be pushed into the problem room. 

With the doors being closed all the time, recommend installing a return vent in the room as well to help cycle the stagnant air. This will allow the air that is trapped to move through the system and be conditioned. 

Recommend a duct cleaning as it has not been done since the house was built. There is quite a bit of dirt that has collected in the ductwork. 

Capacitor for outside unit needs to be replaced. It is well out of acceptable range and will fail soon.
Anna, TX - Customer is having issues with front bedroom not staying conditioned like the rest of the house. Customer keeps doors closed because of kids in the house. With no return in the bedroom, the air cannot be cycled through properly. Bedroom also has three of the four walls exposed to the exterior which can prevent the room from feeling the same temperature as the rest of the house. 

Adjusted the damper for the supply run that goes into the living room. This allowed a little more air to be pushed into the problem room. 

With the doors being closed all the time, recommend installing a return vent in the room as well to help cycle the stagnant air. This will allow the air that is trapped to move through the system and be conditioned. 

Recommend a duct cleaning as it has not been done since the house was built. There is quite a bit of dirt that has collected in the ductwork. 

Capacitor for outside unit needs to be replaced. It is well out of acceptable range and will fail soon.
Skylar M.
Skylar M.
1 system heating maintenance. Replaced filter provided by customer. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time. Recommend duct cleaning and filter conversion kit. This will help keep the system clean so it can retain its efficiency. This can also improve the air quality in the home. Performed dryer vent cleaning. Went onto roof and pulled blockage at vent opening. This was causing the dryer to give an error code.
Anna, TX 75409
Anna, TX - 1 system heating maintenance. Replaced filter provided by customer. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time.

Recommend duct cleaning and filter conversion kit. This will help keep the system clean so it can retain its efficiency. This can also improve the air quality in the home. 

Performed dryer vent cleaning. Went onto roof and pulled blockage at vent opening. This was causing the dryer to give an error code.
Anna, TX - 1 system heating maintenance. Replaced filter provided by customer. Removed and cleaned flame sensor. Checked resistance on hot surface igniter. Measured microamps on flame sensor, it is within acceptable range. Checked blower motor and wheel. Set thermostat to heating and watched system go through sequence of operation. All limit switches and pressure switches are functioning correctly. Flames are healthy with solid blue color. Measured amp draw on blower motor and inducer motor. Checked temperature rise across system. System is heating properly at this time.

Recommend duct cleaning and filter conversion kit. This will help keep the system clean so it can retain its efficiency. This can also improve the air quality in the home. 

Performed dryer vent cleaning. Went onto roof and pulled blockage at vent opening. This was causing the dryer to give an error code.
Skylar M.
Skylar M.
Arrive for one system heat pump heating maintenance. Replaced filter using one from truck stock. Checked operation of drain line, poured water down it to verify it was clear. Checked out system heating in heat pump and emergency heat mode. Measured amp draw on lower motor and heat strips. Check temperature rise across system. Went outside to condenser. Check out electrical components inside cabinet. Measured amp draw on compressor and fan motor. System is operational at this time. Attic insulation is very low and compacted. This is causing the system to overcome the heat coming through the ceiling from the attic. Recommend adding insulation to bring it up to standard dept to keep the conditioned air inside the house.
Anna, TX 75409
Anna, TX - Arrive for one system heat pump heating maintenance. Replaced filter using one from truck stock. Checked operation of drain line, poured water down it to verify it was clear. Checked out system heating in heat pump and emergency heat mode. Measured amp draw on lower motor and heat strips. Check temperature rise across system. Went outside to condenser. Check out electrical components inside cabinet. Measured amp draw on compressor and fan motor. System is operational at this time.

Attic insulation is very low and compacted. This is causing the system to overcome the heat coming through the ceiling from the attic. Recommend adding insulation to bring it up to standard dept to keep the conditioned air inside the house.
Anna, TX - Arrive for one system heat pump heating maintenance. Replaced filter using one from truck stock. Checked operation of drain line, poured water down it to verify it was clear. Checked out system heating in heat pump and emergency heat mode. Measured amp draw on lower motor and heat strips. Check temperature rise across system. Went outside to condenser. Check out electrical components inside cabinet. Measured amp draw on compressor and fan motor. System is operational at this time.

Attic insulation is very low and compacted. This is causing the system to overcome the heat coming through the ceiling from the attic. Recommend adding insulation to bring it up to standard dept to keep the conditioned air inside the house.
Said H.
Said H.
Blower Motor and Control Board Replacement Removed the existing blower motor assembly and control board from the system. Installed a new blower motor assembly and replacement control board. After completing the installation, tested system operation to verify proper functionality. Allowed the system to run for over 15 minutes and verified a temperature split of 20°F, indicating proper heating/cooling performance at the time of testing. Inspected the ductwork and found significant dirt and buildup throughout the system. Recommend a Level 2 ductwork cleaning to improve overall air quality, airflow, and system cleanliness.
Anna, TX 75409
Anna, TX - Blower Motor and Control Board Replacement
Removed the existing blower motor assembly and control board from the system. Installed a new blower motor assembly and replacement control board. After completing the installation, tested system operation to verify proper functionality.
Allowed the system to run for over 15 minutes and verified a temperature split of 20°F, indicating proper heating/cooling performance at the time of testing.
Inspected the ductwork and found significant dirt and buildup throughout the system. Recommend a Level 2 ductwork cleaning to improve overall air quality, airflow, and system cleanliness.
Anna, TX - Blower Motor and Control Board Replacement
Removed the existing blower motor assembly and control board from the system. Installed a new blower motor assembly and replacement control board. After completing the installation, tested system operation to verify proper functionality.
Allowed the system to run for over 15 minutes and verified a temperature split of 20°F, indicating proper heating/cooling performance at the time of testing.
Inspected the ductwork and found significant dirt and buildup throughout the system. Recommend a Level 2 ductwork cleaning to improve overall air quality, airflow, and system cleanliness.
Skylar M.
Skylar M.
Arrive for no Cool. Customer stated that thermostat was set to cooling, but there was not cold air coming from vents. Checked refrigerant pressures and system was almost completely empty. Filled system up with nitrogen and performed leak search. Located leak on the bottom inside of the evaporator coil. System is under warranty until 2028. Need to talk with Office about pricing before ordering coil.
Anna, TX 75409
Anna, TX - Arrive for no Cool. Customer stated that thermostat was set to cooling, but there was not cold air coming from vents. Checked refrigerant pressures and system was almost completely empty. Filled system up with nitrogen and performed leak search. Located leak on the bottom inside of the evaporator coil. System is under warranty until 2028. Need to talk with Office about pricing before ordering coil.
Anna, TX - Arrive for no Cool. Customer stated that thermostat was set to cooling, but there was not cold air coming from vents. Checked refrigerant pressures and system was almost completely empty. Filled system up with nitrogen and performed leak search. Located leak on the bottom inside of the evaporator coil. System is under warranty until 2028. Need to talk with Office about pricing before ordering coil.
Jesse V.
Jesse V.
No
Anna, TX 75409
Said H.
Said H.
Heating Maintenance Report Performed heating maintenance on the system and inspected all major components for proper operation. Checked blower motor amp draw and recorded a reading of 2.4 amps. Inspected the blower wheel, evaporator coil, and return cabinet for cleanliness. All components were found to be clean and in good condition. Inspected attic ductwork and insulation. Ductwork appears to be properly sealed, and attic insulation levels are sufficient. Measured system temperature split and recorded 20.7°F. Tested emergency heat operation and recorded an amp draw of 21.01 amps. Inspected and cleaned the outdoor condenser cabinet. Checked condenser amp draw and recorded 6.15 amps, which is within acceptable operating range. Checked condenser fan motor amp draw and recorded 0.63 amps, which is within acceptable operating range. Tested capacitor readings: Compressor capacitor: 44 MFD (Rated 45 MFD). Condenser fan capacitor: 5 MFD (Rated 5 MFD). Both capacitor readings checked out withi
Anna, TX 75409
Anna, TX - Heating Maintenance Report
Performed heating maintenance on the system and inspected all major components for proper operation.
Checked blower motor amp draw and recorded a reading of 2.4 amps.
Inspected the blower wheel, evaporator coil, and return cabinet for cleanliness. All components were found to be clean and in good condition.
Inspected attic ductwork and insulation. Ductwork appears to be properly sealed, and attic insulation levels are sufficient.
Measured system temperature split and recorded 20.7°F.
Tested emergency heat operation and recorded an amp draw of 21.01 amps.
Inspected and cleaned the outdoor condenser cabinet.
Checked condenser amp draw and recorded 6.15 amps, which is within acceptable operating range.
Checked condenser fan motor amp draw and recorded 0.63 amps, which is within acceptable operating range.
Tested capacitor readings:
Compressor capacitor: 44 MFD (Rated 45 MFD).
Condenser fan capacitor: 5 MFD (Rated 5 MFD).
Both capacitor readings checked out withi
Anna, TX - Heating Maintenance Report
Performed heating maintenance on the system and inspected all major components for proper operation.
Checked blower motor amp draw and recorded a reading of 2.4 amps.
Inspected the blower wheel, evaporator coil, and return cabinet for cleanliness. All components were found to be clean and in good condition.
Inspected attic ductwork and insulation. Ductwork appears to be properly sealed, and attic insulation levels are sufficient.
Measured system temperature split and recorded 20.7°F.
Tested emergency heat operation and recorded an amp draw of 21.01 amps.
Inspected and cleaned the outdoor condenser cabinet.
Checked condenser amp draw and recorded 6.15 amps, which is within acceptable operating range.
Checked condenser fan motor amp draw and recorded 0.63 amps, which is within acceptable operating range.
Tested capacitor readings:
Compressor capacitor: 44 MFD (Rated 45 MFD).
Condenser fan capacitor: 5 MFD (Rated 5 MFD).
Both capacitor readings checked out withi
Skylar M.
Skylar M.
Arrive for no Cool on upstairs system. Customer stated that indoor air was blowing, but it was not cold. Indoor and outdoor units were both running but temperature split was only 3°. Checked refrigerant pressures and found it extremely low. Performed leak search and found leak in evaporator coil. Coil is covered under parts warranty, customer will pay labor and refrigerant. Office will look into availability of part and contact customer once they know.
Anna, TX 75409
Anna, TX - Arrive for no Cool on upstairs system. Customer stated that indoor air was blowing, but it was not cold. Indoor and outdoor units were both running but temperature split was only 3°. Checked refrigerant pressures and found it extremely low. Performed leak search and found leak in evaporator coil. Coil is covered under parts warranty, customer will pay labor and refrigerant. Office will look into availability of part and contact customer once they know.
Anna, TX - Arrive for no Cool on upstairs system. Customer stated that indoor air was blowing, but it was not cold. Indoor and outdoor units were both running but temperature split was only 3°. Checked refrigerant pressures and found it extremely low. Performed leak search and found leak in evaporator coil. Coil is covered under parts warranty, customer will pay labor and refrigerant. Office will look into availability of part and contact customer once they know.
Said H.
Said H.
**HVAC Service Report – Condensate Drain Line Service** Upon arrival, found the condensate drain line for the larger system completely clogged, along with the home’s main drain line\. Also discovered that both the larger and smaller HVAC systems were connected to the same sink drain line\. Inspected the smaller system’s drain line and confirmed it was clear and free of obstructions\. Proceeded to unclog the larger system’s drain line and clean the P\-trap to restore proper drainage\. **Recommendations:** - Recommend replacing all existing condensate drain lines due to their approximate age of nine years and the potential buildup of debris and residue from years of operation without cleaning\. - Recommend relocating the larger system’s drain line to the sink stack located directly behind the unit\. Approximately 5 feet of PVC piping will be required\. - Recommend keeping the smaller system’s drain line connected to its existing sink drain location, requiring approximately 15 feet of
Anna, TX 75409
Anna, TX - **HVAC Service Report – Condensate Drain Line Service**

Upon arrival, found the condensate drain line for the larger system completely clogged, along with the home’s main drain line\. Also discovered that both the larger and smaller HVAC systems were connected to the same sink drain line\.

Inspected the smaller system’s drain line and confirmed it was clear and free of obstructions\. Proceeded to unclog the larger system’s drain line and clean the P\-trap to restore proper drainage\.

**Recommendations:**

- Recommend replacing all existing condensate drain lines due to their approximate age of nine years and the potential buildup of debris and residue from years of operation without cleaning\.
- Recommend relocating the larger system’s drain line to the sink stack located directly behind the unit\. Approximately 5 feet of PVC piping will be required\.
- Recommend keeping the smaller system’s drain line connected to its existing sink drain location, requiring approximately 15 feet of
Anna, TX - **HVAC Service Report – Condensate Drain Line Service**

Upon arrival, found the condensate drain line for the larger system completely clogged, along with the home’s main drain line\. Also discovered that both the larger and smaller HVAC systems were connected to the same sink drain line\.

Inspected the smaller system’s drain line and confirmed it was clear and free of obstructions\. Proceeded to unclog the larger system’s drain line and clean the P\-trap to restore proper drainage\.

**Recommendations:**

- Recommend replacing all existing condensate drain lines due to their approximate age of nine years and the potential buildup of debris and residue from years of operation without cleaning\.
- Recommend relocating the larger system’s drain line to the sink stack located directly behind the unit\. Approximately 5 feet of PVC piping will be required\.
- Recommend keeping the smaller system’s drain line connected to its existing sink drain location, requiring approximately 15 feet of

Your High Efficiency

Experts