Adon Complete Air Conditioning and Heating has provided HVAC services in Plano, TX, for years, serving Collin County from our home base in Anna, just up Highway 75. Whether your AC quits on a July afternoon, your furnace needs attention before the first cold front, or you are ready to upgrade to a more efficient system, our technicians regularly work in Plano neighborhoods and know the homes here well.

Plano is one of the largest cities we serve, and its homes reflect that. We work on older single-stage systems in established East Plano neighborhoods and modern variable-speed equipment in newer Legacy corridor builds. Many larger homes in Plano run two separate HVAC systems, and we are experienced diagnosing and servicing both in the same visit. We service all makes and models; we are a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we are available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in PlanoCall (903) 482-4900

HVAC Services We Offer in Plano, TX

AC Repair: Same-day AC repair available throughout Plano and Collin County. We diagnose and repair all makes and models, and most calls are resolved in a single visit. When your air conditioning goes out in the Plano heat, we treat it like the emergency it is.

AC Installation and Replacement: When your Plano home needs a new system, we size it correctly using a load calculation and install it to manufacturer specs. All new installations come with up to a 10-year labor warranty. We’ll help you choose the right capacity and efficiency rating for your home, not just the unit that fits the budget.

Heating Repair and Installation: We service gas furnaces, heat pumps, and electric systems throughout Plano. Winters here are mild but the occasional hard freeze is real, and a furnace that won’t fire in January isn’t something you want to wait on. We stock parts for the most common brands and most repairs are done in one visit.

HVAC Maintenance: Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Plano homeowners running two systems, it’s the most practical way to keep both units maintained without scheduling separate visits.

Ductless Mini-Split Systems: Plano’s sunrooms, home offices, garage conversions, and older additions without ductwork are ideal for ductless mini-splits. We install single and multi-zone systems throughout Plano, and they’re significantly more efficient than window units or electric baseboard heat.

Heat Pumps: Heat pumps handle both heating and cooling from a single system and are a practical choice for Plano homeowners who want year-round efficiency. In a climate where extreme cold is rare but energy costs matter, a modern heat pump often outperforms a traditional gas furnace and AC combo on annual operating costs.

Indoor Air Quality: Newer construction in Plano is built tight for energy efficiency, which traps allergens, dust, and humidity inside. We offer air filtration systems, UV air purifiers, ventilators, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Plano area homeowners.

Duct Cleaning and Duct Repair: Leaky or dirty ductwork is one of the most common causes of uneven temperatures and high energy bills in Plano homes, especially two-story and multi-system properties. We inspect, clean, and seal ductwork throughout Plano and Collin County, and fixing the ducts often makes a bigger difference than replacing the equipment.

Why Plano Homeowners Choose Adon Complete for HVAC Service

Neighborhoods We Serve in Plano, TX

We provide HVAC services throughout Plano, including Legacy West, Windhaven Meadows, Willow Bend, Haggard Park, Ridgeview Ranch, Chase Oaks, and the communities along the Dallas North Tollway corridor. We also serve Plano’s neighboring cities, including Allen, McKinney, Frisco, and Anna. If you’re not sure whether we cover your area, call us, and we’ll let you know.

Schedule HVAC Service in PlanoCall (903) 482-4900

Plano, TX HVAC FAQ

How much does AC repair cost in Plano, TX?

Most AC repairs in Plano run between $150 and $600, depending on the repair type. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs, like a blower motor or evaporator coil, cost more. We give you a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Plano?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Plano and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC during a Plano summer can’t wait until morning.

My Plano home has two HVAC systems. Can you service both on the same visit?

Yes, and we do it regularly. Many larger Plano homes, particularly those along the DNT corridor and in the Legacy area, run separate systems for the upstairs and downstairs zones. Our technicians can diagnose and service both units in the same appointment, saving time and giving us a complete picture of how the home is performing.

My newer Plano home feels stuffy even though the AC is working fine. What is going on?

Tight construction is usually the culprit. Homes built in Plano’s newer developments are sealed for energy efficiency, which reduces natural air exchange and traps moisture, allergens, and CO2 inside. A whole-home ventilator or ERV brings in fresh outdoor air while recovering the energy you have already spent conditioning the air inside. It is the right fix for stuffy newer construction, and we install them throughout Plano.

What HVAC brands do you service in Plano?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands, but we do not turn down a job because of what brand is on the equipment.

Schedule HVAC Service in Plano, TX Today

Whether you need same-day AC repair, a new system installed, or want to get on a maintenance plan before the heat hits, Adon Complete Air Conditioning and Heating is ready to help. Call us at (903) 482-4900 or click below to schedule. We also serve the surrounding Collin County communities of Allen, McKinney, Wylie, and Anna.

Schedule HVAC Service in PlanoCall (903) 482-4900

Recent Jobs and Reviews in Plano, TX

Rated 4.9 out of 5 stars based on 9 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Plano, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Plano, TX between July 2025 and August 2025.

The most recent job was on August 22, 2025.

Adon Complete Air Conditioning and Heating has completed 81 jobs in Plano, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Matthew C.
Matthew C.
-Contactor -Turbo Multi Use Capacitor 3 - 5-2-1 Hard Start Kit We preformed cooling maintenance on 4 single gas systems. Upon arrival client stated that the main down stairs unit was possibly low on Freon and wasn’t keeping up. We tested all electrical components on the inside units. All electrical components inside tested within manufacturer specifications. Supply temps for the master bedroom, second downstairs living area and upstairs was 55 degrees. The downstairs unit that was in question supply temperature was 61. We proceeded outside to test all electrical along with run and start amps on all the units. The master bedroom and the upstairs electrical components were testing within manufacturer specifications, but were testing high on start amps. The downstairs second living area electrical components were testing outside of manufacturer specifications and starting on high start amps. The downstairs main areas electrical components were testing within manufacturer specifications.
Plano, TX 75093
Plano, TX - -Contactor
-Turbo Multi Use Capacitor
3 - 5-2-1 Hard Start Kit 

We preformed cooling maintenance on 4 single gas systems. Upon arrival client stated that the main down stairs unit was possibly low on Freon and wasn’t keeping up. We tested all electrical components on the inside units. All electrical components inside tested within manufacturer specifications. Supply temps for the master bedroom, second downstairs living area and upstairs was 55 degrees. The downstairs unit that was in question supply temperature was 61. We proceeded outside to test all electrical along with run and start amps on all the units. The master bedroom and the upstairs electrical components were testing within manufacturer specifications, but were testing high on start amps. The downstairs second living area electrical components were testing outside of manufacturer specifications and starting on high start amps. The downstairs main areas electrical components were testing within manufacturer specifications.
Plano, TX - -Contactor
-Turbo Multi Use Capacitor
3 - 5-2-1 Hard Start Kit 

We preformed cooling maintenance on 4 single gas systems. Upon arrival client stated that the main down stairs unit was possibly low on Freon and wasn’t keeping up. We tested all electrical components on the inside units. All electrical components inside tested within manufacturer specifications. Supply temps for the master bedroom, second downstairs living area and upstairs was 55 degrees. The downstairs unit that was in question supply temperature was 61. We proceeded outside to test all electrical along with run and start amps on all the units. The master bedroom and the upstairs electrical components were testing within manufacturer specifications, but were testing high on start amps. The downstairs second living area electrical components were testing outside of manufacturer specifications and starting on high start amps. The downstairs main areas electrical components were testing within manufacturer specifications.
Jacob P.
Jacob P.
13 supplies 4 returns $219.90 Member saving
Plano, TX 75093
Plano, TX - 13 supplies 4 returns

$219.90 Member saving
Plano, TX - 13 supplies 4 returns

$219.90 Member saving
jcg311690@gmail.com
jcg311690@gmail.com
Call back for water leaking under sink after drain flush. Customer also wanted to address the fact that he couldn’t turn his hot water off after repair was done. I replaced the ac pvc drain line with a clear flex pipe that’s being held tight with clamps and tightened up the connections under the sink to stop the water dripping.
Plano, TX 75024
Matthew C.
Matthew C.
Upon arrival client stated that he needed the thermostat recalibrated, check his humidity settings and connect the Wi-Fi to his thermostat. We connected Wi-Fi with router information client provided, we recalibrated the thermostat and adjusted the humidity settings. We proceeded with the cooling maintenance and tested all electrical components inside on the unit in the attic. All tested within manufacturer specifications. We treated the drain lines of with total c and changed the filter. Temperature drop was 17 degrees. We proceeded to the outside unit to test all electrical components and run and start amps of the compressor and fan motors. We found that the outdoor unit was not running while the thermostat was calling for cooling. We brought the homeowner outside to show him and tested the capacitor. We found the capacitor to be failing at 37.4/ 40 ufs. Homeowner elected to have us replace the capacitor. All other electrical components tested within manufacturer specifications. Start
Plano, TX 75075
Plano, TX - Upon arrival client stated that he needed the thermostat recalibrated, check his humidity settings and connect the Wi-Fi to his thermostat. We connected Wi-Fi with router information client provided, we recalibrated the thermostat and adjusted the humidity settings. We proceeded with the cooling maintenance and tested all electrical components inside on the unit in the attic. All tested within manufacturer specifications. We treated the drain lines of with total c and changed the filter. Temperature drop was 17 degrees. We proceeded to the outside unit to test all electrical components and run and start amps of the compressor and fan motors. We found that the outdoor unit was not running while the thermostat was calling for cooling. We brought the homeowner outside to show him and tested the capacitor. We found the capacitor to be failing at 37.4/ 40 ufs. Homeowner elected to have us replace the capacitor. All other electrical components tested within manufacturer specifications. Start
Plano, TX - Upon arrival client stated that he needed the thermostat recalibrated, check his humidity settings and connect the Wi-Fi to his thermostat. We connected Wi-Fi with router information client provided, we recalibrated the thermostat and adjusted the humidity settings. We proceeded with the cooling maintenance and tested all electrical components inside on the unit in the attic. All tested within manufacturer specifications. We treated the drain lines of with total c and changed the filter. Temperature drop was 17 degrees. We proceeded to the outside unit to test all electrical components and run and start amps of the compressor and fan motors. We found that the outdoor unit was not running while the thermostat was calling for cooling. We brought the homeowner outside to show him and tested the capacitor. We found the capacitor to be failing at 37.4/ 40 ufs. Homeowner elected to have us replace the capacitor. All other electrical components tested within manufacturer specifications. Start
Jacob P.
Jacob P.
Demand call for downstairs gas system from 2014 turning on and off. Upon arrival customer stated that the system has been running and cooling but will turn off and the thermostat will go blank for awhile and then it will start back up and run like normal until it shuts off again. During my inspection the customer took me to his attic to show me the system, while we were up there I checked the water safety switch to see if it was activating and sure enough the primary drain line was filled with water which caused the water switch to activate. The customer then took me to where the system drain terminated which was in an upstairs restroom. I explained to the customer that we need to flush the drain line to remove the clog but I can’t guarantee the drain line wont get clogged up again due to the water heater being connected to the ac drain line. Customer agreed to have his line flushed and for me to check the rest of the system to make sure nothing got damaged when it was turning on and
Plano, TX 75024
Matthew C.
Matthew C.
Upon arrival Homeowner did mention how he could get his humidity down in the house. Current humidity is at 44%. He keeps his house set on 80-81 degrees. Advised to use the circulation setting to help curclate the air to keep humidity lower. Preformed cooling maintenance on single communicating gas system. We checked all electrical components inside, all tested within manufacturer specifications. Treated the drain line with total c. Filters did not need to be changed at this time. Temperature across the indoor coil was 20 degrees. We proceeded outside. Tested run and start amps of the compressor and fan motors, all tested within manufacturer specifications. Rinsed out door coil. Unit was cooling upon departure.
Plano, TX 75023
Plano, TX - Upon arrival Homeowner did mention how he could get his humidity down in the house. Current humidity is at 44%. He keeps his house set on 80-81 degrees. Advised to use the circulation setting to help curclate the air to keep humidity lower. Preformed cooling maintenance on single communicating gas system. We checked all electrical components inside, all tested within manufacturer specifications. Treated the drain line with total c. Filters did not need to be changed at this time. Temperature across the indoor coil was 20 degrees. We proceeded outside. Tested run and start amps of the compressor and fan motors, all tested within manufacturer  specifications. Rinsed out door coil. Unit was cooling upon departure.
Plano, TX - Upon arrival Homeowner did mention how he could get his humidity down in the house. Current humidity is at 44%. He keeps his house set on 80-81 degrees. Advised to use the circulation setting to help curclate the air to keep humidity lower. Preformed cooling maintenance on single communicating gas system. We checked all electrical components inside, all tested within manufacturer specifications. Treated the drain line with total c. Filters did not need to be changed at this time. Temperature across the indoor coil was 20 degrees. We proceeded outside. Tested run and start amps of the compressor and fan motors, all tested within manufacturer  specifications. Rinsed out door coil. Unit was cooling upon departure.
Jacob P.
Jacob P.
I retuned to our client home due to water dripping from secondary drain line. This time the float switch was not engaged but water was coming from the upstairs unit drain pan. Both primary drain lines are plumbed together and connect underneath the upstairs bathroom sink. I asked our client why he elected not to install a ball valve during the last visit and he said it’s because he plans on replacing the unit in the future. I highly recommended at least adding 1 but he declined. I proceeded to cut the primary drain line further down and was able to clear the clog and ensure it was draining properly. I also removed some residual water with my shop vacuum. Both units are cooling on departure.
Plano, TX 75025
Plano, TX - I retuned to our client home due to water dripping from secondary drain line. This time the float switch was not engaged but water was coming from the upstairs unit drain pan. Both primary drain lines are plumbed together and connect underneath the upstairs bathroom sink. I asked our client why he elected not to install a ball valve during the last visit and he said it’s because he plans on replacing the unit in the future. I highly recommended at least adding 1 but he declined. 
I proceeded to cut the primary drain line further down and was able to clear the clog and ensure it was draining properly. I also removed some residual water with my shop vacuum. Both units are cooling on departure.
Plano, TX - I retuned to our client home due to water dripping from secondary drain line. This time the float switch was not engaged but water was coming from the upstairs unit drain pan. Both primary drain lines are plumbed together and connect underneath the upstairs bathroom sink. I asked our client why he elected not to install a ball valve during the last visit and he said it’s because he plans on replacing the unit in the future. I highly recommended at least adding 1 but he declined. 
I proceeded to cut the primary drain line further down and was able to clear the clog and ensure it was draining properly. I also removed some residual water with my shop vacuum. Both units are cooling on departure.
Jacob P.
Jacob P.
** not covered under parts and labor warranty** Refrigerant per pound cost - reduced price because of major repair Liquid line dryer - filter for the refrigerant that needs to be replaced when opening the system to atmospheric pressure.
Plano, TX 75075
Shelby S.
Shelby S.
Upon arrival, I found that the compressor was in a thermal lockout. I cooled the compressor to allow myself to diagnose it. I found that the compressor is not pumping refrigerant. I further verified the failure by shutting the liquid line and found it would not pump down. I asked Kelsie to figure out the availability due to what time it was, and I continued progressing through my call. Kelsie informed me that the compressor is available and we will need to reach out to the customer in the morning to update with a timeline. I priced the refrigerant and liquid line dryer. I took a deposit of 200.00 and collected my dispatch.
Plano, TX 75075
Brayden W.
Brayden W.
Arrived on site customer stated that he thinks it could be the drain line as he had that serviced last yr. Inspected drain line and found it to be clear although a little sluggey. Tested capacitor on condenser and found it to have failed. Discussed with customer options for replacing cap. Homeowner elected to go forward with turbo 200. Replaced capacitor and unit came on without issue. Proceeded with unit maintenance 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected dr
Plano, TX 75074