Menu

Heating and Air Conditioning Services in Sherman, TX

Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between September 2026 and October 2026.

The 9 customer reviews shown here average 5.0 out of 5.

The most recent job was on October 14, 2026.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Reviews

Incredible service! Affordable rates.
In less tha 4 hours after we requested service we had COLD AIR again. Very professional service and technician. We WILL recommend this company to our customers and friends.
Marcos &Kate - Sherman, TX 75090
Great
Nice guy, knowledgeable.
Steven - Sherman, TX 75090
Will want to use again
On time great price
Beverly - Sherman, TX 75092
Awesome!
Chris was so polite and caring, he made sure I was completely satisfied with the work he did and he was very efficient! I highly recommend Chris at Adon A/C
McKee - Sherman, TX 75090
Great
He did great
Sang - Sherman, TX 75092
Great work
He did what he suppose to do
Sang - Sherman, TX 75092
Outstanding Service!
Sandra - Sherman, TX 75090
Excellent Technician, very knowledgeable.
Very few technicians have spent the time he did in going thru our system. He is quite personable and down to earth. Most thorough and complete job! He is every bit a professional at his trade.
Warren - Sherman, TX 75092
Pastor pathway
Had a great visit was well pleased
Don - Sherman, TX 75090

Job Locations

Skylar M.
Skylar M.
Arrive for no Cool on single system home. Thermostat was set to cool, indoor blower was running but condenser was not. Checked voltage at condenser, getting 240 from disconnect. There is not 24 V going to contactor. Checked wiring, going to unit and found it had broken as it goes into the cabinet. Cut and reconnected broken wires. Contactor was heavily pitted and very black, customer approved replacement. After replacing contactor and fixing broken wires, tested system in cooling. Condenser came on and is running. Measure temperature coming from supply, getting 64°. System is cooling at this time.
Sherman, TX 75090
Sherman, TX - Arrive for no Cool on single system home. Thermostat was set to cool, indoor blower was running but condenser was not. Checked voltage at condenser, getting 240 from disconnect. There is not 24 V going to contactor. Checked wiring, going to unit and found it had broken as it goes into the cabinet. Cut and reconnected broken wires. Contactor was heavily pitted and very black, customer approved replacement. After replacing contactor and fixing broken wires, tested system in cooling. Condenser came on and is running. Measure temperature coming from supply, getting 64°. System is cooling at this time.
Sherman, TX - Arrive for no Cool on single system home. Thermostat was set to cool, indoor blower was running but condenser was not. Checked voltage at condenser, getting 240 from disconnect. There is not 24 V going to contactor. Checked wiring, going to unit and found it had broken as it goes into the cabinet. Cut and reconnected broken wires. Contactor was heavily pitted and very black, customer approved replacement. After replacing contactor and fixing broken wires, tested system in cooling. Condenser came on and is running. Measure temperature coming from supply, getting 64°. System is cooling at this time.
Said H.
Said H.
performed heat maintenance and system. Change filter. Checked auxiliary kit. Treated drain lines. Check capacitor outside. System is currently running at this time. System is not gas. It’s an air handler with a straight AC outside.
Sherman, TX 75090
Sherman, TX -  performed heat maintenance and system. Change filter. Checked auxiliary kit. Treated drain lines. Check capacitor outside. System is currently running at this time. System is not gas. It’s an air handler with a straight AC outside.
Sherman, TX -  performed heat maintenance and system. Change filter. Checked auxiliary kit. Treated drain lines. Check capacitor outside. System is currently running at this time. System is not gas. It’s an air handler with a straight AC outside.
Skylar M.
Skylar M.
Arrive for no Cool. Customer stated that indoor unit was blowing air and outside fan was running, but there was no cold air coming through the vents. Took panel off outdoor unit and noticed a burning smell. Check capacitor, and it is still good. Noticed that top of hard start kit capacitor was black. Tested hard start kit and it had failed. We installed it earlier last year and they come with three-year warranty. Replaced hard start kit under parts only warranty. Check trough on compressor when it started. Compressor is operating with within acceptable range. System is cooling at this time.
Sherman, TX 75090
Sherman, TX - Arrive for no Cool. Customer stated that indoor unit was blowing air and outside fan was running, but there was no cold air coming through the vents. Took panel off outdoor unit and noticed a burning smell. Check capacitor, and it is still good. Noticed that top of hard start kit capacitor was black. Tested hard start kit and it had failed. We installed it earlier last year and they come with three-year warranty. Replaced hard start kit under parts only warranty. Check trough on compressor when it started. Compressor is operating with within acceptable range. System is cooling at this time.
Sherman, TX - Arrive for no Cool. Customer stated that indoor unit was blowing air and outside fan was running, but there was no cold air coming through the vents. Took panel off outdoor unit and noticed a burning smell. Check capacitor, and it is still good. Noticed that top of hard start kit capacitor was black. Tested hard start kit and it had failed. We installed it earlier last year and they come with three-year warranty. Replaced hard start kit under parts only warranty. Check trough on compressor when it started. Compressor is operating with within acceptable range. System is cooling at this time.
Skylar M.
Skylar M.
1 system heating maintenance. System is electric air handler with heat pump. Checked system in heat pump and emergency heat mode. Measured amp draw on heat strips, all are working correctly. Checked temperature rise across system for both heat pump heating and emergency heat. Treated drain line using Total C drain solution. Outdoor unit is variable so there is no capacitor or contactor. Performed chemical coil cleaning on outside and inside units. Replaced faulty suction line temperature sensor and compressor dome sensor under parts and labor warranty. Installed air scrubber and connected it to transformer. Installed remote temperature sensor, customer is going to move it around to see where it works the best. He was having issues with his bedroom not staying consistent temperature. We opened damper all the way, it was closed slightly. System is operating at this time.
Sherman, TX 75092
Sherman, TX - 1 system heating maintenance. System is electric air handler with heat pump. Checked system in heat pump and emergency heat mode. Measured amp draw on heat strips, all are working correctly. Checked temperature rise across system for both heat pump heating and emergency heat. Treated drain line using Total C drain solution. Outdoor unit is variable so there is no capacitor or contactor. 

Performed chemical coil cleaning on outside and inside units. Replaced faulty suction line temperature sensor and compressor dome sensor under parts and labor warranty. Installed air scrubber and connected it to transformer. Installed remote temperature sensor, customer is going to move it around to see where it works the best. He was having issues with his bedroom not staying consistent temperature. We opened damper all the way, it was closed slightly. System is operating at this time.
Sherman, TX - 1 system heating maintenance. System is electric air handler with heat pump. Checked system in heat pump and emergency heat mode. Measured amp draw on heat strips, all are working correctly. Checked temperature rise across system for both heat pump heating and emergency heat. Treated drain line using Total C drain solution. Outdoor unit is variable so there is no capacitor or contactor. 

Performed chemical coil cleaning on outside and inside units. Replaced faulty suction line temperature sensor and compressor dome sensor under parts and labor warranty. Installed air scrubber and connected it to transformer. Installed remote temperature sensor, customer is going to move it around to see where it works the best. He was having issues with his bedroom not staying consistent temperature. We opened damper all the way, it was closed slightly. System is operating at this time.
Jesse V.
Jesse V.
Here’s a polished version for your service notes: Service Visit Summary Upon arrival, we found that the customer’s Trane 824 thermostat was not connecting to Wi-Fi. We performed a hard power reset of the thermostat/system controls. After restoring power and allowing the thermostat to reboot, the Wi-Fi connection was successfully restored and the thermostat was operating properly. Additional Recommendation – Attic Insulation We also discussed the condition of the customer’s attic insulation and provided an estimate for blown-in attic insulation. The customer stated that she would review the insulation options with her family members before making a decision. Current Status: • Trane 824 thermostat Wi-Fi connection restored • Thermostat operating properly at completion of visit • Attic insulation estimate provided • Customer will follow up after discussing the insulation options with her family I can also make this more technical for ServiceTitan/invoice documentation if that’s wh
Sherman, TX 75090
Sherman, TX - Here’s a polished version for your service notes:

Service Visit Summary

Upon arrival, we found that the customer’s Trane 824 thermostat was not connecting to Wi-Fi.

We performed a hard power reset of the thermostat/system controls. After restoring power and allowing the thermostat to reboot, the Wi-Fi connection was successfully restored and the thermostat was operating properly.

Additional Recommendation – Attic Insulation

We also discussed the condition of the customer’s attic insulation and provided an estimate for blown-in attic insulation.

The customer stated that she would review the insulation options with her family members before making a decision.

Current Status:
• Trane 824 thermostat Wi-Fi connection restored
• Thermostat operating properly at completion of visit
• Attic insulation estimate provided
• Customer will follow up after discussing the insulation options with her family

I can also make this more technical for ServiceTitan/invoice documentation if that’s wh
Sherman, TX - Here’s a polished version for your service notes:

Service Visit Summary

Upon arrival, we found that the customer’s Trane 824 thermostat was not connecting to Wi-Fi.

We performed a hard power reset of the thermostat/system controls. After restoring power and allowing the thermostat to reboot, the Wi-Fi connection was successfully restored and the thermostat was operating properly.

Additional Recommendation – Attic Insulation

We also discussed the condition of the customer’s attic insulation and provided an estimate for blown-in attic insulation.

The customer stated that she would review the insulation options with her family members before making a decision.

Current Status:
• Trane 824 thermostat Wi-Fi connection restored
• Thermostat operating properly at completion of visit
• Attic insulation estimate provided
• Customer will follow up after discussing the insulation options with her family

I can also make this more technical for ServiceTitan/invoice documentation if that’s wh
Skylar M.
Skylar M.
Customer was having concerns about error alerts on thermostat. He reset the power to the system and all the alerts went away except for the suction temperature sensor. We reset power and left it off to try and get error to clear. Once power was put back on, the error was still present. Need to replace suction temperature sensor under parts and labor warranty. Coils have not been deep cleaned since the system was installed 4 years ago and there is quite a bit of buildup. Customer approved chemical foam cleaning for inside and outside units. Reme Halo air purifier bulb has burnt out. This will need to be replaced as well. Customer was interested in the air scrubber as well, he is going to compare the options with his wife and get back to us.
Sherman, TX 75092
Sherman, TX - Customer was having concerns about error alerts on thermostat. He reset the power to the system and all the alerts went away except for the suction temperature sensor. We reset power and left it off to try and get error to clear. Once power was put back on, the error was still present. Need to replace suction temperature sensor under parts and labor warranty. 

Coils have not been deep cleaned since the system was installed 4 years ago and there is quite a bit of buildup. Customer approved chemical foam cleaning for inside and outside units. 

Reme Halo air purifier bulb has burnt out. This will need to be replaced as well. Customer was interested in the air scrubber as well, he is going to compare the options with his wife and get back to us.
Sherman, TX - Customer was having concerns about error alerts on thermostat. He reset the power to the system and all the alerts went away except for the suction temperature sensor. We reset power and left it off to try and get error to clear. Once power was put back on, the error was still present. Need to replace suction temperature sensor under parts and labor warranty. 

Coils have not been deep cleaned since the system was installed 4 years ago and there is quite a bit of buildup. Customer approved chemical foam cleaning for inside and outside units. 

Reme Halo air purifier bulb has burnt out. This will need to be replaced as well. Customer was interested in the air scrubber as well, he is going to compare the options with his wife and get back to us.
Skylar M.
Skylar M.
System #4 thermostat was blank. After inspecting unit found that primary drain line was clogged and float switch shut unit down. Blew out drain line using nitrogen and vacuumed out extra buildup that was present. Poured water down drain line to verify it was clear. Treated primary drain pan using algae guard strip. System came back on and system is cooling at this time.
Sherman, TX 75090
Sherman, TX - System #4 thermostat was blank. After inspecting unit found that primary drain line was clogged and float switch shut unit down. Blew out drain line using nitrogen and vacuumed out extra buildup that was present. Poured water down drain line to verify it was clear. Treated primary drain pan using algae guard strip. System came back on and system is cooling at this time.
Sherman, TX - System #4 thermostat was blank. After inspecting unit found that primary drain line was clogged and float switch shut unit down. Blew out drain line using nitrogen and vacuumed out extra buildup that was present. Poured water down drain line to verify it was clear. Treated primary drain pan using algae guard strip. System came back on and system is cooling at this time.
Skylar M.
Skylar M.
Arrive for no cool. Indoor blower was running but condenser was not. Checked for voltage and condenser was not getting 24v. Went into attic and checked float switch. Float switch was stuck in the up position which was not allowing condenser to come on. Removed gunk holding the float switch in the up position so it can drop smoothly. If float switch malfunctions again we will need to replace it. Put cap on drain before trap as it did not have one. System is cooling at this time.
Sherman, TX 75092
Skylar M.
Skylar M.
System #3 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time. System #7 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time. Treated both coil pan with algae guard to help treat the drain as the system drains naturally.
Sherman, TX 75090
Sherman, TX - System #3 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time. 

System #7 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time.

Treated both coil pan with algae guard to help treat the drain as the system drains naturally.
Sherman, TX - System #3 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time. 

System #7 no cool. Thermostat was blank on arrival. After locating unit, found that primary drain line was clogged up. This was causing float switch to shut unit down. Cleared primary drain line using nitrogen and water. Poured water down drain after clearing it to verify all water would drain out. System is cooling at this time.

Treated both coil pan with algae guard to help treat the drain as the system drains naturally.
Skylar M.
Skylar M.
Arrive for no cool. Customer stated that he got a notification from his thermostat that the system had lost power multiple times. He poured vinegar down the drain and the problem stopped happening. I went to verify the drain was completely clear but it back up into the tub. Used customers plunger and was able to get clog out of tub drain. Once tub was draining, AC drained out completely. Poured more water down to make sure it was clear. System is cooling at this time.
Sherman, TX 75090
Sherman, TX - Arrive for no cool. Customer stated that he got a notification from his thermostat that the system had lost power multiple times. He poured vinegar down the drain and the problem stopped happening. I went to verify the drain was completely clear but it back up into the tub. Used customers plunger and was able to get clog out of tub drain. Once tub was draining, AC drained out completely. Poured more water down to make sure it was clear. System is cooling at this time.