Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.
We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.
HVAC Services We Offer in Sherman
We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:
AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.
Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.
Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.
Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.
Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.
Why Sherman Homeowners Choose Adon Complete
- We’re close by. We’re based in Anna, TX, a short drive down Highway 75. Our technicians are in Sherman neighborhoods regularly and know the homes and properties on both sides of US-75.
- Owner Jesse Villarreal has over 27 years of HVAC experience. When you call Adon Complete, you’re not calling a franchise call center. You’re calling a local company where the owner is actively involved and his reputation is on the line with every job.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC contractor serving Sherman can say that.
- We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable way to keep your system reliable year-round.
AC and Heating Service Throughout Sherman and Grayson County
We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.
Sherman HVAC FAQ
Here are some common questions we get.
How much does AC repair cost in Sherman, TX?
Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Sherman?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.
What HVAC brands do you service in Sherman?
We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in Sherman?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.
What areas of Sherman do you serve?
We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.
Schedule HVAC Service in Sherman Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Sherman, TX
Sherman, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between June 2025 and July 2025.
The most recent job was on July 4, 2025.
Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.
Job Locations
I arrived at our clients home for the downstairs unit not working properly. Our client said that the unit had intermittent problems. She felt as if it struggled to heat and cool the home for over the last year. She took me outside to show me the outdoor heat pump units and we both immediately saw that the downstairs heat pump was completely frozen over. I let her know that due to the current state of the frozen system I could only test and check certain electrical components today. I tested and inspected both outdoor heat pumps. Contractors and capacitors tested within manufacture specifications today. I then went into the attic and found that the downstairs air handler had a failed indoor blower motor. The indoor coil was completely frozen over as well. I took the model and serial number for the downstairs air handler and I was able to find that the equipment is still under parts warranty. We will contact the manufacturer and locate the motor for our client. She is aware of the
Process warranty under parts for Manufacture.. Acquisition of warranty components. Remove all refrigerant from system with recovery tanks if needed. Remove coil from system. Chemical flush on copper lines to remove non-condensibles. Install new evaporator coil Install new bi-flow liquid line drier(outside) Confirm system is tight and sealed on all welds. Pressurize system with nitrogen 300 pounds to verify no leaks. Wait for 30 minutes to see the system holds up on pressure for 30 minutes 300 pounds. Completion of leak check. Put a vacuum on the system to remove any moisture in air. Evacuate system under 500 µm. Completion of evacuating a system. Recharge system with refrigerant back to manufacture specifications System start up and diagnostics. Run system for 20 minutes before Commissioning the system. System is cooling with 20° drop. Our client is aware it needs to run for several hours before meeting thermostat set-point. System is cooling properly on departure.
Found compromised evaporator coil leaking refrigerant in a upflow air handler that is located in garage closet. Photo & video documentation made of leak. System has valid warranty until 2032. Presented estimate for replacement and homeowner authorized replacement costs. Paid $500 deposit Ordered coil from Shearer Supply and part is at will call in Denton/shearer supply. Order #DE009376 Dispatch will reach out to homeowner to schedule replacement.
- Upon arrival found compressor not functioning due to compressor wire that supposed to connect to capacitor was not properly connected. - properly wired the existing capacitor and compressor started to function again. - Checked all electrical components, amp draw, & wiring/sheathing. - Refrigerant charge is at/within manufacturer’s operating specifications. - System operating with dirty 20 x 20 x 1” air filter in the ceiling. - Homeowner said that he would replace filter himself. System functioning & cooling again upon departure. System requires maintenance/condenser coil cleaning. Homeowner was unable to make the $79 service charge fee payment today. Homeowner explained that he had a hardship/car issues and that his card was in his car that is not available to him at time of service. I believe is what he said?.. Homeowner wanted to know if we can schedule the annual maintenance for Wednesday this week and he can pay for the maintenance with the service charge. Technician allow
Found unit was low on refrigerant Added 3 pounds.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange Found high start amps and low ohm reading on contactor on outdoor unit. This means the unit is drawing more power than it should be on start up. The compressor puts the most wear itself and other electrical components when it gets moving from a stand still. I was measuring that the unit was pulling around 100amps out of a 11
Upon arrival customer had water leaking from the ceiling. Upon further inspection of the unit we found that the main and secondary drain lines were clogged. We presented the issue with the customer. Customer elected to add blow out valve, pan float and blow out drain lines. Both lines are now draining properly and pan float has been installed. Unit cooling upon departure.
Homeowner has complaints of water damage due to a blocked secondary discharge that has been covered by a pest control man at the soffit. Inside diagnostics: Found dirty 20x20x1 filter/upstairs. The entire indoor equipment it’s not hung properly and is unlevel due to damage to where it is hung from framing/for roof support. The framing where the equipment is hung, has detached itself from the roofing framing causing system to be improperly level and the condensation is not draining out of the primary drain discharge port. Water finds in the path of least resistance and a leaking out of the back left corner of the evaporator coil housing then onto the auxiliary/emergency drain pan that is supposed to reroute outside but secondary discharge port to soffit is blocked with a piece of metal. Weak blower motor Capacitor. High blower amps. Dirty blower motor wheel. Outdoor equipment: weak compressor capacitor. Contactor reading above manufacturers recommended replacement rating. Compressor s
Upon arrival, I found the system producing a 9 degree temperature difference. I checked the refrigerant pressures and found that the suction pressure is running high and that I’m getting liquid refrigerant back at the suction port. I have determined that the TXV has failed and is in the stuck open position. To get this unit to function properly, we will need to replace the TXV. I observed other issues and those are a burnt contactor and and filthy condenser coil. I provided options to address these issues.
Attached the service port cover