Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in August 2026.
The most recent job was on August 17, 2026.
Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
NA
Upon arrival at the property, I inspected the HVAC system and found that the communication wiring between the thermostat and the blower motor control board was not receiving required voltage. The system is equipped with a Johnson controls control board. Due to the system being controlled by Johnson controls, and potentially still being covered under the manufacturers warranty, I recommended that the owner contact Johnson Controls directly to have the issue diagnosed and addressed under the applicable warranty.
Coming back with motor
No cool on single AC system. Indoor blower was running but condenser was not. Getting 24v to contactor and it is sending proper voltage through it. Checked capacitor and it is still good. Fan motor was seized up but compressor was not running either. Cooled compressor down and tried to start it. Compressor is locked up, which was caused by the fan motor going out. System is out of warranty and needs to be replaced. Sent lead to office.
No cool on electric air handler. When system is powered on error code E201 is displayed. This is for lost communication with indoor blower motor. Checked for voltage coming out of board, getting proper voltage to motor. Blower motor is not communicating back to board, motor needs to be replaced. Need to look into warranty and availability of motor.
Arrived at the homeowners residence to diagnose an HVAC system issue. Upon investigation, I found the start capacitor to be defective. An estimate was provided to the homeowner via email and approved by the homeowner through e-signature. Perform the approved repair by replacing the defective start capacitor with a turbo 200 X start capacitor. Checked the condensate drain line and confirmed it was clear and draining properly. Tested the HVAC system after completing the repair. System is operating properly at this time.
Daikin Mini Split Inverter Board Replacement Scope of Work • Diagnose and confirm failure of the existing inverter control board • Safely disconnect power and access the indoor/outdoor mini split components as required • Remove failed Daikin inverter board • Install new Daikin replacement inverter board • Verify all electrical connections and system communication • Test system operation and verify proper heating/cooling performance Materials & Equipment • Daikin replacement inverter board • Electrical connectors and installation materials as needed • Diagnostic and testing equipment Special Notes • Replacement board will be installed to restore proper communication and operation of the Daikin mini split system • System will be fully tested after installation to verify proper operation and performance • If additional issues are discovered during the repair, they will be discussed with the customer before any additional work is performed Replaced inverter board assembly, correct volt
Customer had concerns about high humidity upstairs. House has single system that is zoned. Checked drain lines to verify they are clear, poured water down and it drained freely. Used sycrometer to test humidity levels at thermostat compared to the readings on thermostat. My tested showed that humidity was at 51% when thermostat showed 70%. Adjusted settings in thermostat to help make it more accurate. Also set thermostat to overcool by 1° to help remove more humidity. System is cooling properly and staying at temperature that is set.
1 system AC maintenance. Customer just replaced filter, it is still good. Checked operation of drain line and treated it with drain solution. Measured temperature drop across coil, getting 21° drop. Measured amp draw on blower motor. Went outside to condenser and checked amp draw on compressor and fan motor. Measured capacitor and contactor. Contactor is pitted and has burn marks, recommend replacing it. Checked starting amp draw on compressor, it is over the manufacturer limits. Recommend adding hard start kit to prolong the life of the compressor. Cleaned condenser coil using water. System is cooling at this time.
Customer noticed that outdoor fan motor would stop running while the compressor would continue to run. Talked with tech support to determine if it was the fan or control board. Found that control board was not sending consistent voltage to the fan motor. Control board needs to be replaced.