Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in July 2026.
The most recent job was on July 22, 2026.
Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
No cool on downstairs system. Indoor blower came on but was not cooling. Checked for voltage outside and only getting 18v. Went into attic and found that transformer was not sending full 24v out. Replaced transformer and powered on system. Checked refrigerant pressures and subcooling. System is cooling at this time.
No cool on single system. Indoor blower was running but condenser was not. Found that capacitor had failed. Customer approved replacement, using turbo capacitor with 5 year warranty. Checked operation of system after repair. Measured amp draw on compressor and condenser fan motor. Checked temperature split across coil, return 85° and supply 67°. System is cooling at this time.
Customer was concerned that system was not keeping up with set temperature yesterday afternoon. Went through system completely, filter is still good. Checked temperature split across coil, 74° return and 55° supply. Insulation is 13” and not compacted. Checked refrigerant pressures and subcooling. Checked amp draw on compressor, fan motor and blower motor. All are operating within manufacturer specs. System is maintaining 71° currently. With the heat outside, it is very hard for system to keep temperature that low. System is operating at normal capacity, and is cooling at this time.
Upon arrival, I noticed that emergency drain pan was full of water and that water was dripping from the bottom side of the air handler cabinet. Checked doors off and thoroughly investigated primary drain pan to make sure there were no cracks. I did not see any. I clogged primary drain line with a piece of armor flex and then filled up primary drain pan with a gallon of water to see if it would hold while the system was off. Primary drain pan held water without any leaks and then unclogged primary drain line and all of the water quickly drained out until I put the fence stack with the cap back on then it immediately stopped draining and then realized it was due to the capped off stack not allowing primary drain line to drain properly. I cleaned up all of the water out of the emergency drain pan and got as much water out of the air handler cabinet as I could put doors back on and tested system for several minutes and did not see any more water starting to drip out of cabinet. I believe t
No cool on smaller unit. When thermostat was set to cool, indoor blower was on but condenser wasn’t. Getting 24v to contactor. Capacitor is swollen and dead. Replaced capacitor under parts and labor warranty. Measured temperature drop across coil, return 83° and supply 64°. System is cooling at this time.
No cool on single system. When thermostat was set to cool, indoor blower was running but condenser was not. Getting 24v outside and 240 at bottom of contactor but power was not going through contactor. Customer approved replacement of contactor. Checked operation of system after repair. Measured temperature drop across system, 76° return and 56° supply.
No cool on single system. Condenser fan motor was running but compressor was not. Checked capacitor and it is dead. Capacitor needs to be replaced. Changed capacitor and tested system after repair. System is cooling at this time.
No cool on upstairs system. We just replaced the evaporator coil. Indoor and outdoor units are running. Checked temperature split and only getting 8° difference. Checked refrigerant pressures and they are jumping all over the place. Took coil door off and found no TXV installed and the piston for 410a was on top of the coil not installed either. There is no refrigerant metering devise in the system. Office will reach out to customer in the morning to schedule the repair.
1 system AC maintenance. Checked filter, it is in good condition and does not need to be replaced. Measured amp draw on blower motor. Checked temperature drop across system, only getting 14° difference. Noticed oily residue on evaporator coil. Checked drain line operation and treated it with drain solution. Blower wheel is getting a bit dirty again, recommend installing UV light to help keep blower and system clean, previously mentioned by Shelby. Checked amp draw on compressor and condenser fan motor. Measured capacitor, it is within acceptable tolerance. Checked starting amp draw on compressor, it is within manufacturer limits. Cleaned condenser coil using water. Quick leak search found leak in evaporator coil. Coil is under parts warranty.