Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in June 2026.

The most recent job was on June 26, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
Trane ECM Blower Motor Replacement Scope of Work • Remove failed ECM blower motor from existing Trane air handler/furnace • Install new Trane ECM replacement blower motor • Verify proper motor wiring, configuration, and operation • Test blower speeds and system airflow to confirm proper performance Materials & Equipment • Trane ECM blower motor • Installation materials and wiring connections as needed Special Notes • ECM blower motors are designed to provide improved efficiency, airflow control, and reliable system operation • System will be tested after installation to verify proper blower operation and overall system performance Deposit & Lead Time • A $200 deposit is required to order the replacement blower motor • Part is currently in stock and will be ordered once deposit is received
Anna, TX 75409
Anna, TX - Trane ECM Blower Motor Replacement

Scope of Work
• Remove failed ECM blower motor from existing Trane air handler/furnace
• Install new Trane ECM replacement blower motor
• Verify proper motor wiring, configuration, and operation
• Test blower speeds and system airflow to confirm proper performance

Materials & Equipment
• Trane ECM blower motor
• Installation materials and wiring connections as needed

Special Notes
• ECM blower motors are designed to provide improved efficiency, airflow control, and reliable system operation
• System will be tested after installation to verify proper blower operation and overall system performance

Deposit & Lead Time
• A $200 deposit is required to order the replacement blower motor
• Part is currently in stock and will be ordered once deposit is received
Anna, TX - Trane ECM Blower Motor Replacement

Scope of Work
• Remove failed ECM blower motor from existing Trane air handler/furnace
• Install new Trane ECM replacement blower motor
• Verify proper motor wiring, configuration, and operation
• Test blower speeds and system airflow to confirm proper performance

Materials & Equipment
• Trane ECM blower motor
• Installation materials and wiring connections as needed

Special Notes
• ECM blower motors are designed to provide improved efficiency, airflow control, and reliable system operation
• System will be tested after installation to verify proper blower operation and overall system performance

Deposit & Lead Time
• A $200 deposit is required to order the replacement blower motor
• Part is currently in stock and will be ordered once deposit is received
Shelby S.
Shelby S.
Upon arrival, I found the system low on R410a. I traced the leak down to the outdoor unit. With an electronic leak detector, I found the leak on one of the tubes connected to the TXV. This is completely copper and repairable. I took pictures and videos of the location. We will need to remove the remaining refrigerant, remove the liquid line dryer, protect the outdoor TXV, braze the leak point, install a new liquid line dryer, vacuum the refrigerant lines to remove contamination, and charge the system back to its proper running pressures. I provided pricing to address the issue. We will need to reach out in the morning to figure out how to proceed.
Anna, TX 75409
Anna, TX - Upon arrival, I found the system low on R410a. I traced the leak down to the outdoor unit. With an electronic leak detector, I found the leak on one of the tubes connected to the TXV. This is completely copper and repairable. I took pictures and videos of the location. We will need to remove the remaining refrigerant, remove the liquid line dryer, protect the outdoor TXV, braze the leak point, install a new liquid line dryer, vacuum the refrigerant lines to remove contamination, and charge the system back to its proper running pressures. I provided pricing to address the issue. We will need to reach out in the morning to figure out how to proceed.
Anna, TX - Upon arrival, I found the system low on R410a. I traced the leak down to the outdoor unit. With an electronic leak detector, I found the leak on one of the tubes connected to the TXV. This is completely copper and repairable. I took pictures and videos of the location. We will need to remove the remaining refrigerant, remove the liquid line dryer, protect the outdoor TXV, braze the leak point, install a new liquid line dryer, vacuum the refrigerant lines to remove contamination, and charge the system back to its proper running pressures. I provided pricing to address the issue. We will need to reach out in the morning to figure out how to proceed.
Shelby S.
Shelby S.
I performed a single cooling maintenance on a 2020 gas system. I observed the home is having higher than recommended humidity. I adjusted the fresh air to minimize the amount of humidity being pulled in from outside. The fresh air intake sits right above the outdoor unit pulling in extremely hot air being exhausted off the condenser. Also, I advised doing chemical cleanings of the indoor equipment to maximize air flow and equipment longevity. Customer declined replacement of the filter and cleanings at the time of service. System is cooling but has high humidity upon departure.
Anna, TX 75409
Anna, TX - I performed a single cooling maintenance on a 2020 gas system. I observed the home is having higher than recommended humidity. I adjusted the fresh air to minimize the amount of humidity being pulled in from outside. The fresh air intake sits right above the outdoor unit pulling in extremely hot air being exhausted off the condenser. Also, I advised doing chemical cleanings of the indoor equipment to maximize air flow and equipment longevity. Customer declined replacement of the filter and cleanings at the time of service. System is cooling but has high humidity upon departure.
Anna, TX - I performed a single cooling maintenance on a 2020 gas system. I observed the home is having higher than recommended humidity. I adjusted the fresh air to minimize the amount of humidity being pulled in from outside. The fresh air intake sits right above the outdoor unit pulling in extremely hot air being exhausted off the condenser. Also, I advised doing chemical cleanings of the indoor equipment to maximize air flow and equipment longevity. Customer declined replacement of the filter and cleanings at the time of service. System is cooling but has high humidity upon departure.
Brayden W.
Brayden W.
Arrived on site, found TXV frozen. Measured refrigerant pressures and found them to be low. Provided estimates for leak search as well as recharging the unit with refrigerant. Advised customer we would not be able to conduct the leak check right now and would likley not be able to until next week. Customer elected to go forward with refrigerant recharge for now to get the system cooling. Charged system with 4 lbs of 410a. Measured 55 degree supply air. System cooling on departure.
Anna, TX 75409
Anna, TX - Arrived on site, found TXV frozen. Measured refrigerant pressures and found them to be low. Provided estimates for leak search as well as recharging the unit with refrigerant. Advised customer we would not be able to conduct the leak check right now and would likley not be able to until next week.  Customer elected to go forward with refrigerant recharge for now to get the system cooling. Charged system with 4 lbs of 410a. Measured 55 degree supply air. System cooling on departure.
Anna, TX - Arrived on site, found TXV frozen. Measured refrigerant pressures and found them to be low. Provided estimates for leak search as well as recharging the unit with refrigerant. Advised customer we would not be able to conduct the leak check right now and would likley not be able to until next week.  Customer elected to go forward with refrigerant recharge for now to get the system cooling. Charged system with 4 lbs of 410a. Measured 55 degree supply air. System cooling on departure.
Shelby S.
Shelby S.
System was installed in May. This has been an issue since approximately 2 weeks after installation. I proceeded to the attic and noticed minimal water being produced in the condensate drains. I took a temperature differential and found it to only be 15 degrees. The supply temp is 59 and the return is 74. To pull humidity out of the air, we need a supply temperature lower than 55 degrees. I considered slowing the blower speed, but my suction pressure is too low. Slowing the speed will cause it to drop more likely into freezing. The system calls for an 8 degree sub cooling and it is currently 2.5. It appears this system was not topped off with R454b during the initial install. I requested pricing and availability from the office. The office will reach back out when both are determined. The system did not drop temp after approximately 45mins of run time.
Anna, TX 75409
Anna, TX - System was installed in May. This has been an issue since approximately 2 weeks after installation. I proceeded to the attic and noticed minimal water being produced in the condensate drains. I took a temperature differential and found it to only be 15 degrees. The supply temp is 59 and the return is 74. To pull humidity out of the air, we need a supply temperature lower than 55 degrees. I considered slowing the blower speed, but my suction pressure is too low. Slowing the speed will cause it to drop more likely into freezing. The system calls for an 8 degree sub cooling and it is currently 2.5. It appears this system was not topped off with R454b during the initial install. I requested pricing and availability from the office. The office will reach back out when both are determined. 

The system did not drop temp after approximately 45mins of run time.
Anna, TX - System was installed in May. This has been an issue since approximately 2 weeks after installation. I proceeded to the attic and noticed minimal water being produced in the condensate drains. I took a temperature differential and found it to only be 15 degrees. The supply temp is 59 and the return is 74. To pull humidity out of the air, we need a supply temperature lower than 55 degrees. I considered slowing the blower speed, but my suction pressure is too low. Slowing the speed will cause it to drop more likely into freezing. The system calls for an 8 degree sub cooling and it is currently 2.5. It appears this system was not topped off with R454b during the initial install. I requested pricing and availability from the office. The office will reach back out when both are determined. 

The system did not drop temp after approximately 45mins of run time.
Brayden W.
Brayden W.
Arrived on site found unit sweating on the exterior of box. Measured 51 degree supply air. Adjusted airspeed from tap 3 to tap 4. Found mastic seal coming apart on side of unit and sealed to prevent air leakage. Insulated p-trap and suction line a little better to prevent all condensation. Tested and ran unit for 30 minutes and did not see anymore condensation. Measured supply air at 54.9. Also discussed air scrubber as the wife suffers from allergies. System in good working order upon departure.
Anna, TX 75409
Anna, TX - Arrived on site found unit sweating on the exterior of box. Measured 51 degree supply air. Adjusted airspeed from tap 3 to tap 4. Found mastic seal coming apart on side of unit and sealed to prevent air leakage. Insulated p-trap and suction line a little better to prevent all condensation. Tested and ran unit for 30 minutes and did not see anymore condensation. Measured supply air at 54.9. Also discussed air scrubber as the wife suffers from allergies. System in good working order upon departure.
Anna, TX - Arrived on site found unit sweating on the exterior of box. Measured 51 degree supply air. Adjusted airspeed from tap 3 to tap 4. Found mastic seal coming apart on side of unit and sealed to prevent air leakage. Insulated p-trap and suction line a little better to prevent all condensation. Tested and ran unit for 30 minutes and did not see anymore condensation. Measured supply air at 54.9. Also discussed air scrubber as the wife suffers from allergies. System in good working order upon departure.
Brayden W.
Brayden W.
Return Monday late afternoon
Anna, TX 75409
Anna, TX - Return Monday late afternoon
Anna, TX - Return Monday late afternoon
Brayden W.
Brayden W.
Arrived on site found, thermostat set to 69 and outdoor temp 70 as it’s started to rain. System cooling at this time. Found emergency drain pan full of water. Checked filter and it was extremely dirty. Homeowner is unsure when it was changed last as husband had knee surgery and has been unable to change it recently. Found TXV jacket had water in it but not a lot. Tested drain lines and found them to be draining at this time. Measured refrigerant pressures and found them to be good considering indoor/outdoor temp with 8 degree subcool. Upon further inspection it was found that algae was partially blocking the primary drain port causing water to sit higher than it should in the primary drain pan. When pouring water into primary water was observed spilling out the side of the primary pan. Homeowner approved drain line unclogging. Vacuumed out algae from around primary drain port and poured gallons of hot water to flush algae out of primary pan and tested with more water. Did not observe w
Anna, TX 75409
Anna, TX - Arrived on site found, thermostat set to 69 and outdoor temp 70 as it’s started to rain. System cooling at this time. Found emergency drain pan full of water. Checked filter and it was extremely dirty. Homeowner is unsure when it was changed last as husband had knee surgery and has been unable to change it recently. Found TXV jacket had water in it but not a lot. Tested drain lines and found them to be draining at this time. Measured refrigerant pressures and found them to be good considering indoor/outdoor temp with 8 degree subcool. Upon further inspection it was found that algae was partially blocking the primary drain port causing water to sit higher than it should in the primary drain pan. When pouring water into primary water was observed spilling out the side of the primary pan. Homeowner approved drain line unclogging. Vacuumed out algae from around primary drain port and poured gallons of hot water to flush algae out of primary pan and tested with more water. Did not observe w
Anna, TX - Arrived on site found, thermostat set to 69 and outdoor temp 70 as it’s started to rain. System cooling at this time. Found emergency drain pan full of water. Checked filter and it was extremely dirty. Homeowner is unsure when it was changed last as husband had knee surgery and has been unable to change it recently. Found TXV jacket had water in it but not a lot. Tested drain lines and found them to be draining at this time. Measured refrigerant pressures and found them to be good considering indoor/outdoor temp with 8 degree subcool. Upon further inspection it was found that algae was partially blocking the primary drain port causing water to sit higher than it should in the primary drain pan. When pouring water into primary water was observed spilling out the side of the primary pan. Homeowner approved drain line unclogging. Vacuumed out algae from around primary drain port and poured gallons of hot water to flush algae out of primary pan and tested with more water. Did not observe w
Brayden W.
Brayden W.
Performed contactor and capacitor replacement. Tested and system is running well upon departure.
Anna, TX 75409
Anna, TX - Performed contactor and capacitor replacement. Tested and system is running well upon departure.
Anna, TX - Performed contactor and capacitor replacement. Tested and system is running well upon departure.
Shelby S.
Shelby S.
Found x13 blower is faulty. We will need to reach out to trane to locate and price part tomorrow.
Anna, TX 75409
Anna, TX - Found x13 blower is faulty. We will need to reach out to trane to locate and price part tomorrow.
Anna, TX - Found x13 blower is faulty. We will need to reach out to trane to locate and price part tomorrow.

Your High Efficiency