Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in May 2026.

The most recent job was on May 27, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Matthew C.
Matthew C.
Preformed full system inspection on a 1997 lennox r22 gas system. The system needs to be upgraded. The system is not cooling the house properly. There is a leak in the system most likely. There are only 3 supply vents for the whole 1300sqft home. Duct work needs to be redone. Both supply and returns. System will need a new line set. Recommend moving the unit to the attic to free up closet space in bedroom. Thermostat placement is not in a good spot air vent blows right on to it which will cause humidity issues and unit being satisfied before it actually cools the house.
Anna, TX 75409
Anna, TX - Preformed full system inspection on a 1997 lennox r22 gas system. The system needs to be upgraded. The system is not cooling the house properly. There is a leak in the system most likely. There are only 3 supply vents for the whole 1300sqft home. Duct work needs to be redone. Both supply and returns. System will need a new line set. Recommend moving the unit to the attic to free up closet space in bedroom.  Thermostat placement is not in a good spot air vent blows right on to it which will cause humidity issues and unit being satisfied before it actually cools the house.
Anna, TX - Preformed full system inspection on a 1997 lennox r22 gas system. The system needs to be upgraded. The system is not cooling the house properly. There is a leak in the system most likely. There are only 3 supply vents for the whole 1300sqft home. Duct work needs to be redone. Both supply and returns. System will need a new line set. Recommend moving the unit to the attic to free up closet space in bedroom.  Thermostat placement is not in a good spot air vent blows right on to it which will cause humidity issues and unit being satisfied before it actually cools the house.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 14. Tested drain lines for proper drainage Outdoor electrical was testing within manufacturer specification across the board. Found insulation missing from suction line on small bedroom units. This will reduce system efficiency. Found drain line to small bedroom unit draining, but very slowly. Advise drain line clear
Anna, TX 75409
Anna, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return.
14. Tested drain lines for proper drainage

Outdoor electrical was testing within manufacturer specification across the board. Found insulation missing from suction line on small bedroom units. This will reduce system efficiency.

Found drain line to small bedroom unit draining, but very slowly. Advise drain line clear
Anna, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return.
14. Tested drain lines for proper drainage

Outdoor electrical was testing within manufacturer specification across the board. Found insulation missing from suction line on small bedroom units. This will reduce system efficiency.

Found drain line to small bedroom unit draining, but very slowly. Advise drain line clear
Jesse V.
Jesse V.
Upon arrival, I discovered the system that services the bedrooms not cooling well. I hooked my gauges up and found that the system was low on R410a. I went over the options to address this issue with customer. The customer opted to replace the condenser and evaporator coil. During my visit, I noticed that the all the systems need a duct cleaning. The level 1 is for the downstairs system. The other 2 systems need a level 2. The downstairs system needs a new emergency drain pan due to it being rusted through. Customer approved the duct cleanings and emergency drain pan. The pan is a 30x60. Customer got approved for financing, and I collected a down payment. Application process was taking a bit of time, and I passed it on to the office to finish the process.
Anna, TX 75409
Anna, TX - Upon arrival, I discovered the system that services the bedrooms not cooling well. I hooked my gauges up and found that the system was low on R410a. I went over the options to address this issue with customer. The customer opted to replace the condenser and evaporator coil. During my visit, I noticed that the all the systems need a duct cleaning. The level 1 is for the downstairs system. The other 2 systems need a level 2. The downstairs system needs a new emergency drain pan due to it being rusted through. Customer approved the duct cleanings and emergency drain pan. The pan is a 30x60. Customer got approved for financing, and I collected a down payment. Application process was taking a bit of time, and I passed it on to the office to finish the process.
Anna, TX - Upon arrival, I discovered the system that services the bedrooms not cooling well. I hooked my gauges up and found that the system was low on R410a. I went over the options to address this issue with customer. The customer opted to replace the condenser and evaporator coil. During my visit, I noticed that the all the systems need a duct cleaning. The level 1 is for the downstairs system. The other 2 systems need a level 2. The downstairs system needs a new emergency drain pan due to it being rusted through. Customer approved the duct cleanings and emergency drain pan. The pan is a 30x60. Customer got approved for financing, and I collected a down payment. Application process was taking a bit of time, and I passed it on to the office to finish the process.
Shelby S.
Shelby S.
Upon arrival, I discovered that the compressor is not pumping. After further investigation it appears the Common winding broke internally on the compressor. The only other time this happens is to keep the comoressor from overheating. The compressor was cool to the touch and ruled out overheating. The compressor will need to be replaced to eradicate the issue.
Anna, TX 75409
Anna, TX - Upon arrival, I discovered that the compressor is not pumping. After further investigation it appears the Common winding broke internally on the compressor. The only other time this happens is to keep the comoressor from overheating. The compressor was cool to the touch and ruled out overheating. The compressor will need to be replaced to eradicate the issue.
Anna, TX - Upon arrival, I discovered that the compressor is not pumping. After further investigation it appears the Common winding broke internally on the compressor. The only other time this happens is to keep the comoressor from overheating. The compressor was cool to the touch and ruled out overheating. The compressor will need to be replaced to eradicate the issue.
Matthew C.
Matthew C.
Preformed single system maintenance on a zoned Amana heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Client did not have a filter for me to change at today's visit. 20x25x4 in the attic. Found drain line to be partially blocked draining very slowly. By having the drain line unclogged you can help prevent water from backing up and getting into the ceiling. The blower wheel and evaporator coil could use a deep cleaning starting develope an odor. I proceeded outside to tested all electrical components on the outside unit. All tested within manufacturer specifications. I did notice there is a lot of debris build up coming out of the condenser unit. By having it deep cleaned and debris removed it will help the unit preform as efficiently as possible. Unit was rinsed with water at today's visit and is cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed single system maintenance on a zoned Amana heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Client did not have a filter for me to change at today's visit. 20x25x4 in the attic. Found drain line to be partially blocked draining very slowly. By having the drain line unclogged you can help prevent water from backing up and getting into the ceiling. The blower wheel and evaporator coil could use a deep cleaning starting develope an odor. I proceeded outside to tested all electrical components on the outside unit. All tested within manufacturer specifications. I did notice there is a lot of debris build up coming out of the condenser unit. By having it deep cleaned and debris removed it will help the unit preform as efficiently as possible. Unit was rinsed with water at today's visit and is cooling upon departure.
Anna, TX - Preformed single system maintenance on a zoned Amana heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Client did not have a filter for me to change at today's visit. 20x25x4 in the attic. Found drain line to be partially blocked draining very slowly. By having the drain line unclogged you can help prevent water from backing up and getting into the ceiling. The blower wheel and evaporator coil could use a deep cleaning starting develope an odor. I proceeded outside to tested all electrical components on the outside unit. All tested within manufacturer specifications. I did notice there is a lot of debris build up coming out of the condenser unit. By having it deep cleaned and debris removed it will help the unit preform as efficiently as possible. Unit was rinsed with water at today's visit and is cooling upon departure.
Shelby S.
Shelby S.
Upon arrival, I discovered that the system was coming on and visually operational. I proceeded into the attic and discovered that the compressor was not pumping. I went outside and checked the capacitor. It was reading 1.4/70. I ran the warranty, and it expired in April. Customer approved installing the Turbo200x as a replacement. I verified that the system was fully operational and cooling upon departure. Customer signed up for the membership program.
Anna, TX 75409
Anna, TX - Upon arrival, I discovered that the system was coming on and visually operational. I proceeded into the attic and discovered that the compressor was not pumping. I went outside and checked the capacitor. It was reading 1.4/70. I ran the warranty, and it expired in April. Customer approved installing the Turbo200x as a replacement. I verified that the system was fully operational and cooling upon departure. Customer signed up for the membership program.
Anna, TX - Upon arrival, I discovered that the system was coming on and visually operational. I proceeded into the attic and discovered that the compressor was not pumping. I went outside and checked the capacitor. It was reading 1.4/70. I ran the warranty, and it expired in April. Customer approved installing the Turbo200x as a replacement. I verified that the system was fully operational and cooling upon departure. Customer signed up for the membership program.
Shelby S.
Shelby S.
System was having a communication error. I performed a hard reset on the system to see if it would address the error. The system began to work again and is currently cooling. It is currently 83 inside of the build and will take a bit to get back to comfortable. Also, the filter is extremely dirty and needs replacement.
Anna, TX 75409
Anna, TX - System was having a communication error. I performed a hard reset on the system to see if it would address the error. The system began to work again and is currently cooling. It is currently 83 inside of the build and will take a bit to get back to comfortable. Also, the filter is extremely dirty and needs replacement.
Anna, TX - System was having a communication error. I performed a hard reset on the system to see if it would address the error. The system began to work again and is currently cooling. It is currently 83 inside of the build and will take a bit to get back to comfortable. Also, the filter is extremely dirty and needs replacement.
Brayden W.
Brayden W.
Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and emergency heat. Found leak in drain line where it connects to primary drain pan. Replaced Ss1 float switch housing and rebuild drain line ensuring to snug up the primary drain pan fitting very tight this time. System in good working order upon departure. Thank you for your time.
Anna, TX 75409
Anna, TX - Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and emergency heat. Found leak in drain line where it connects to primary drain pan. Replaced Ss1 float switch housing and rebuild drain line ensuring to snug up the primary drain pan fitting very tight this time. System in good working order upon departure. Thank you for your time.
Anna, TX - Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and emergency heat. Found leak in drain line where it connects to primary drain pan. Replaced Ss1 float switch housing and rebuild drain line ensuring to snug up the primary drain pan fitting very tight this time. System in good working order upon departure. Thank you for your time.
Shelby S.
Shelby S.
I performed a single cooling maintenance on a 2025 R454b heat pump system. I checked amps, capacitor, filter, electrical, drains, and cleanliness. During my thorough evaluation, I did not notice any mechanical issues, and the system is cooling well. The inside of the system is currently clean and free of growth. If we install a u/v light into the indoor unit, we can keep growth from forming. To combat drain clogging, I advise installing an algae stick to the drain system. This will allow the drain to be treated constantly for the next 6 months.
Anna, TX 75409
Anna, TX - I performed a single cooling maintenance on a 2025 R454b heat pump system. I checked amps, capacitor, filter, electrical, drains, and cleanliness. During my thorough evaluation, I did not notice any mechanical issues, and the system is cooling well. The inside of the system is currently clean and free of growth. If we install a u/v light into the indoor unit, we can keep growth from forming. To combat drain clogging, I advise installing an algae stick to the drain system. This will allow the drain to be treated constantly for the next 6 months.
Anna, TX - I performed a single cooling maintenance on a 2025 R454b heat pump system. I checked amps, capacitor, filter, electrical, drains, and cleanliness. During my thorough evaluation, I did not notice any mechanical issues, and the system is cooling well. The inside of the system is currently clean and free of growth. If we install a u/v light into the indoor unit, we can keep growth from forming. To combat drain clogging, I advise installing an algae stick to the drain system. This will allow the drain to be treated constantly for the next 6 months.
Shelby S.
Shelby S.
I performed a single cooling maintenances on a 2021 heat pump system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. Due to the past history of this equipment, I advise adding a surge protector directly to the indoor unit to protect this system as much as possible. The outdoor unit could use a thorough deep cleaning with chemicals. Over time the metal becomes oxidized and will reduce in performance.
Anna, TX 75409
Anna, TX - I performed a single cooling maintenances on a 2021 heat pump system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. Due to the past history of this equipment, I advise adding a surge protector directly to the indoor unit to protect this system as much as possible. The outdoor unit could use a thorough deep cleaning with chemicals. Over time the metal becomes oxidized and will reduce in performance.
Anna, TX - I performed a single cooling maintenances on a 2021 heat pump system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. Due to the past history of this equipment, I advise adding a surge protector directly to the indoor unit to protect this system as much as possible. The outdoor unit could use a thorough deep cleaning with chemicals. Over time the metal becomes oxidized and will reduce in performance.