Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX between May 2026 and June 2026.

The most recent job was on June 1, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Brayden W.
Brayden W.
Perform cooling maintenance on zoned 2017 Lennox furnace 1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Capacitor was testing low on the fan side 9.17/10.
Anna, TX 75409
Anna, TX - Perform cooling maintenance on zoned 2017 Lennox furnace
1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Capacitor was testing low on the fan side 9.17/10.
Anna, TX - Perform cooling maintenance on zoned 2017 Lennox furnace
1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Capacitor was testing low on the fan side 9.17/10.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Measured high start amps on compressor. Recommend hard start kit in order to reduce start amps as high star
Anna, TX 75409
Matthew C.
Matthew C.
Upon arrival I found the unit to not be on. I provided a call for cooling and the outdoor condenser would come on but the blower inside would not. I verified voltage on both 24v side and 240v side. Proper voltage is being supplied. Client elected to have motor replacement done under warranty. Unit is still down as of today's visit
Anna, TX 75409
Anna, TX - Upon arrival I found the unit to not be on. I provided a call for cooling and the outdoor condenser would come on but the blower inside would not. I verified voltage on both 24v side and 240v side. Proper voltage is being supplied. Client elected to have motor replacement done under warranty. Unit is still down as of today's visit
Anna, TX - Upon arrival I found the unit to not be on. I provided a call for cooling and the outdoor condenser would come on but the blower inside would not. I verified voltage on both 24v side and 240v side. Proper voltage is being supplied. Client elected to have motor replacement done under warranty. Unit is still down as of today's visit
Brayden W.
Brayden W.
Due to the insulation inside of the unit appearing to get wet, I advise performing a general cleaning on the evaporator coil. This was usually comes from the blower pulling off when the water doesn’t flow off the coil correctly from dust build up on the evaporator coil. Tested drainage from primary coil pan and found it to be draining as intended with no leaking from fittings. This confirms condensation was getting pulled off the coil and winding up in the blower cabinet. Performed evaporator coil cleaning. Allowed chemical to soak in for 10 minutes and rinsed off. Added algae stick to coil pan in order to kill algae and prevent blockages in the drain line. Showed pictures and videos to the homeowner and discussed Aprilaire conversion kit. Explained the benefits of Aprilaire filters over box filters in terms of superior filtration and lowed static pressure to keep the system healthy. System running upon departure.
Anna, TX 75409
Anna, TX - Due to the insulation inside of the unit appearing to get wet, I advise performing a general cleaning on the evaporator coil. This was usually comes from the blower pulling off when the water doesn’t flow off the coil correctly from dust build up on the evaporator coil.

Tested drainage from primary coil pan and found it to be draining as intended with no leaking from fittings. This confirms condensation was getting pulled off the coil and winding up in the blower cabinet. Performed evaporator coil cleaning. Allowed chemical to soak in for 10 minutes and rinsed off. Added algae stick to coil pan in order to kill algae and prevent blockages in the drain line. Showed pictures and videos to the homeowner and discussed Aprilaire conversion kit. Explained the benefits of Aprilaire filters over box filters in terms of superior filtration and lowed static pressure to keep the system healthy. System running upon departure.
Anna, TX - Due to the insulation inside of the unit appearing to get wet, I advise performing a general cleaning on the evaporator coil. This was usually comes from the blower pulling off when the water doesn’t flow off the coil correctly from dust build up on the evaporator coil.

Tested drainage from primary coil pan and found it to be draining as intended with no leaking from fittings. This confirms condensation was getting pulled off the coil and winding up in the blower cabinet. Performed evaporator coil cleaning. Allowed chemical to soak in for 10 minutes and rinsed off. Added algae stick to coil pan in order to kill algae and prevent blockages in the drain line. Showed pictures and videos to the homeowner and discussed Aprilaire conversion kit. Explained the benefits of Aprilaire filters over box filters in terms of superior filtration and lowed static pressure to keep the system healthy. System running upon departure.
Brayden W.
Brayden W.
Replaced capacitor and hard start on older outdoor carrier unit. While rewiring the system I found that the old hard start kit was not properly wired. This is very likely why the hard start kit failed in the first place. Made sure to change wiring to ensure hard start functions properly and tested unit functionality as well as start amps. Measured 29 start amps, when before I was measuring 42. This will help keep compressor and connected electrical components from accumulating undue wear and tear. System running upon departure.
Anna, TX 75409
Anna, TX -  Replaced capacitor and hard start on older outdoor carrier unit. While rewiring the system I found that the old hard start kit was not properly wired. This is very likely why the hard start kit failed in the first place. Made sure to change wiring to ensure hard start functions properly and tested unit functionality as well as start amps. Measured 29 start amps, when before I was measuring 42. This will help keep compressor and connected electrical components from accumulating undue wear and tear.

System running upon departure.
Anna, TX -  Replaced capacitor and hard start on older outdoor carrier unit. While rewiring the system I found that the old hard start kit was not properly wired. This is very likely why the hard start kit failed in the first place. Made sure to change wiring to ensure hard start functions properly and tested unit functionality as well as start amps. Measured 29 start amps, when before I was measuring 42. This will help keep compressor and connected electrical components from accumulating undue wear and tear.

System running upon departure.
Shelby S.
Shelby S.
We would need the vent hood in place before work can begin. We will need approximately 20’ of vent pipe and a roof cap.
Anna, TX 75409
Anna, TX - We would need the vent hood in place before work can begin. We will need approximately 20’ of vent pipe and a roof cap.
Anna, TX - We would need the vent hood in place before work can begin. We will need approximately 20’ of vent pipe and a roof cap.
Brayden W.
Brayden W.
Arrived on site found indoor unit blowing air and outdoor unit not coming on. Found dirty filter advised replacement. Found outdoor disconnect melted. Hot leg coming into disconnect appears to have not been fastened properly and caused the wire to overheat. Advised homeowner there is not enough wire left for me to save and it will be necessary to run new wire. Homeowner advised me he would go back to the company that installed the unit to get this issue fixed.
Anna, TX 75409
Anna, TX - Arrived on site found indoor unit blowing air and outdoor unit not coming on. Found dirty filter advised replacement. Found outdoor disconnect melted. Hot leg coming into disconnect appears to have not been fastened properly and caused the wire to overheat. Advised homeowner there is not enough wire left for me to save and it will be necessary to run new wire. Homeowner advised me he would go back to the company that installed the unit to get this issue fixed.
Anna, TX - Arrived on site found indoor unit blowing air and outdoor unit not coming on. Found dirty filter advised replacement. Found outdoor disconnect melted. Hot leg coming into disconnect appears to have not been fastened properly and caused the wire to overheat. Advised homeowner there is not enough wire left for me to save and it will be necessary to run new wire. Homeowner advised me he would go back to the company that installed the unit to get this issue fixed.
Matthew C.
Matthew C.
Preformed single system maintenance on a 2024 trane heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Treated and flushed the drain line with total c and water. Changed filters for client 16x25x1 in the ceiling. I proceeded to test the outside units electrical. All tested within manufacturer specifications. I rinsed the outside unit with water at today's visit. 55 supply temperature.
Anna, TX 75409
Anna, TX - Preformed single system maintenance on a 2024 trane heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Treated and flushed the drain line with total c and water. Changed filters for client 16x25x1 in the ceiling. I proceeded to test the outside units electrical. All tested within manufacturer specifications. I rinsed the outside unit with water at today's visit. 55 supply temperature.
Anna, TX - Preformed single system maintenance on a 2024 trane heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Treated and flushed the drain line with total c and water. Changed filters for client 16x25x1 in the ceiling. I proceeded to test the outside units electrical. All tested within manufacturer specifications. I rinsed the outside unit with water at today's visit. 55 supply temperature.
Matthew C.
Matthew C.
Preformed dryer vent cleaning
Anna, TX 75409
Anna, TX - Preformed dryer vent cleaning
Anna, TX - Preformed dryer vent cleaning
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Found capacitor testing outside of manufacturer specs and hard start kit failed on master bedroom unit. Har
Anna, TX 75409
Anna, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Found capacitor testing outside of manufacturer specs and hard start kit failed on master bedroom unit. Har
Anna, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Found capacitor testing outside of manufacturer specs and hard start kit failed on master bedroom unit. Har

Your High Efficiency

Experts