Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in March 2026.

The most recent job was on March 17, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
Downstairs main - upon thorough evaluation completion, I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. I found that the system has a 20x20x4 in filter, while this filter is good, there are better options to filtrate the home. By upgrading to the Aprilaire filters you can improve air quality and help keep the system cleaner. Upstairs unit - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. The system is showing signs of growth on the evaporator coil, blower wheel and throughout the unit. By deep cleaning the system and adding a uv stick to the unit it will help combat he growth and help the major components stay clean and last longer. Master bedroom - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system
Anna, TX 75409
Anna, TX - Downstairs main - upon thorough evaluation completion, I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. I found that the system has a 20x20x4 in filter, while this filter is good, there are better options to filtrate the home. By upgrading to the Aprilaire filters you can improve air quality and help keep the system cleaner.

Upstairs unit - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. The system is showing signs of growth on the evaporator coil, blower wheel and throughout the unit. By deep cleaning the system and adding a uv stick to the unit it will help combat he growth and help the major components stay clean and last longer. 

Master bedroom - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system
Anna, TX - Downstairs main - upon thorough evaluation completion, I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. I found that the system has a 20x20x4 in filter, while this filter is good, there are better options to filtrate the home. By upgrading to the Aprilaire filters you can improve air quality and help keep the system cleaner.

Upstairs unit - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system you can increase the life of the unit. The system is showing signs of growth on the evaporator coil, blower wheel and throughout the unit. By deep cleaning the system and adding a uv stick to the unit it will help combat he growth and help the major components stay clean and last longer. 

Master bedroom - upon thorough evaluation completion. I found that the system could benefit from a full system cleaning. By deep cleaning the system
Shelby S.
Shelby S.
I performed a cooling maintenance on a 2018 gas system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. I discovered that the drain line was partially clogged causing slow drain. I installed a blow out valve and cleared the drain. I tested it with water, afterwards. I noticed a herm spade in the outdoor unit was heavily corroded. I replaced the spade to ensure the wire would not burn from bad connection. The return plenum is filthy. This will cause the filter, blower wheel, and evaporator coil to become dirty faster. Customer declined cleaning the plenum at this time. System is cooling upon departure, and I renewed the maintenance program.
Anna, TX 75409
Anna, TX - I performed a cooling maintenance on a 2018 gas system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. I discovered that the drain line was partially clogged causing  slow drain. I installed a blow out valve and cleared the drain. I tested it with water, afterwards. I noticed a herm spade in the outdoor unit was heavily corroded. I replaced the spade to ensure the wire would not burn from bad connection. The return plenum is filthy. This will cause the filter, blower wheel, and evaporator coil to become dirty faster. Customer declined cleaning the plenum at this time. System is cooling upon departure, and I renewed the maintenance program.
Anna, TX - I performed a cooling maintenance on a 2018 gas system. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. I discovered that the drain line was partially clogged causing  slow drain. I installed a blow out valve and cleared the drain. I tested it with water, afterwards. I noticed a herm spade in the outdoor unit was heavily corroded. I replaced the spade to ensure the wire would not burn from bad connection. The return plenum is filthy. This will cause the filter, blower wheel, and evaporator coil to become dirty faster. Customer declined cleaning the plenum at this time. System is cooling upon departure, and I renewed the maintenance program.
Brayden W.
Brayden W.
Performed maintenance on 2024 Trane communicating Heatpump 1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Drain line was draining slowly. Blew on drain line and felt blockage clear. Drain line is draining well at this time. Noticed no surge protection on attic unit. Communicating system are particularly sensitive to surges in power. I ad
Anna, TX 75409
Anna, TX - Performed maintenance on 2024 Trane communicating Heatpump
1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Drain line was draining slowly. Blew on drain line and felt blockage clear. Drain line is draining well at this time. Noticed no surge protection on attic unit. Communicating system are particularly sensitive to surges in power. I ad
Anna, TX - Performed maintenance on 2024 Trane communicating Heatpump
1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Drain line was draining slowly. Blew on drain line and felt blockage clear. Drain line is draining well at this time. Noticed no surge protection on attic unit. Communicating system are particularly sensitive to surges in power. I ad
Brayden W.
Brayden W.
Performed maintenance on 2023 communicating Trane furnace 1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found water in drain pan. Tested primary drain line and found it draining slowly. I was able to mostly clear the blockage with just hot water and blowing on the drain line. Homeowner informed me that they would take apart the sink t
Anna, TX 75409
Anna, TX - Performed maintenance on 2023 communicating Trane furnace 
1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found water in drain pan. Tested primary drain line and found it draining slowly. I was able to mostly clear the blockage with just hot water and blowing on the drain line. Homeowner informed me that they would take apart the sink t
Anna, TX - Performed maintenance on 2023 communicating Trane furnace 
1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found water in drain pan. Tested primary drain line and found it draining slowly. I was able to mostly clear the blockage with just hot water and blowing on the drain line. Homeowner informed me that they would take apart the sink t
Matthew C.
Matthew C.
Upon completion of my thorough evaluation of the system. I found that the condenser and evaporator coil could benefit from a cleaning to maintain peak performance and efficiency. Dust build up is one of the leading causes for an hvac system to break down over time. By deep cleaning the components it will help prolong the life of the system. Also by upgrading your filters to the Aprilaire filters it will help keep the components cleaning longer. I tested all electrical components on the inside and outside unit all tested within manufacturer specifications. I tested and treated the drain lines with water and total c. Unit supply temperature was 52 degrees and 71 return air. I changed the filter for the client 20x25x4. Unit was working properly upon departure.
Anna, TX 75409
Anna, TX - Upon completion of my thorough evaluation of the system. I found that the condenser and evaporator coil could benefit from a cleaning to maintain peak performance and efficiency. Dust build up is one of the leading causes for an hvac system to break down over time. By deep cleaning the components it will help prolong the life of the system. Also by upgrading your filters to the Aprilaire filters it will help keep the components cleaning longer. I tested all electrical components on the inside and outside unit all tested within manufacturer specifications. I tested and treated the drain lines with water and total c. Unit supply temperature was 52 degrees and 71 return air. I changed the filter for the client 20x25x4. Unit was working properly upon departure.
Anna, TX - Upon completion of my thorough evaluation of the system. I found that the condenser and evaporator coil could benefit from a cleaning to maintain peak performance and efficiency. Dust build up is one of the leading causes for an hvac system to break down over time. By deep cleaning the components it will help prolong the life of the system. Also by upgrading your filters to the Aprilaire filters it will help keep the components cleaning longer. I tested all electrical components on the inside and outside unit all tested within manufacturer specifications. I tested and treated the drain lines with water and total c. Unit supply temperature was 52 degrees and 71 return air. I changed the filter for the client 20x25x4. Unit was working properly upon departure.
Brayden W.
Brayden W.
Arrived on site found sensor error on thermostat and was unable to switch to cooling. Found filter to be extremely dirty. Advised homeowner change the filter as soon as possible. This is likely due to recent installation of air scrubber, as it would cause more dust to be filtered out especially so soon from installation. Proceeded to outdoor unit and measured capacitor capacitance. Capacitor was testing at the very lower limit of manufacturer specification and is 9 years old. Informed homeowner that this capacitor is working right now but liable to fail at any time now. Inspected wiring connections and thermostat connections and found no issues. Reset power to the system and thermostat error went away and unit began to cool as normal. Measured 20 degree temperature split across the coil. Advised homeowner that thermostat was the immediate issue and could fail again, but was working for right now. Offered thermostat replacement with either a basic on/off thermostat or a Trane 824 Wi-Fi
Anna, TX 75409
Brayden W.
Brayden W.
Homeowner stated he smelled a sweet oily smell in room under unit and noticed evidence of water in the drain pan previously as well as some oxidation of the copper line dripping into the drain pan. Tested drain line and found it to be draining properly. Tested emergency heat and found it to be working properly. Tested cooling and measured 53 degrees leaving the coil which is within manufacturer specifications. No issues with refrigerant at the moment. Coil looks clean and unobstructed. Noticed water stains coming from duct and plenum connections and felt air escaping from slight gaps in mastic connections. Advised homeowner I believe the stains in the drain pan were likely from these air leaks that can happen over time with thermal expansion and contraction. This is not a major issue right now and everything seems to be working fine mechanically. Advised homeowner that we could take care of this on the next maintenance. Unit in good working order upon departure. Schedule maintenance f
Anna, TX 75409
Anna, TX - Homeowner stated he smelled a sweet oily smell in room under unit and noticed evidence of water in the drain pan previously as well as some oxidation of the copper line dripping into the drain pan. Tested drain line and found it to be draining properly. Tested emergency heat and found it to be working properly. Tested cooling and measured 53 degrees leaving the coil which is within manufacturer specifications. No issues with refrigerant at the moment. Coil looks clean and unobstructed. Noticed water stains coming from duct and plenum connections and felt air escaping from slight gaps in mastic connections. Advised homeowner I believe the stains in the drain pan were likely from these air leaks that can happen over time with thermal expansion and contraction. This is not a major issue right now and everything seems to be working fine mechanically. Advised homeowner that we could take care of this on the next maintenance. Unit in good working order upon departure.

Schedule maintenance f
Anna, TX - Homeowner stated he smelled a sweet oily smell in room under unit and noticed evidence of water in the drain pan previously as well as some oxidation of the copper line dripping into the drain pan. Tested drain line and found it to be draining properly. Tested emergency heat and found it to be working properly. Tested cooling and measured 53 degrees leaving the coil which is within manufacturer specifications. No issues with refrigerant at the moment. Coil looks clean and unobstructed. Noticed water stains coming from duct and plenum connections and felt air escaping from slight gaps in mastic connections. Advised homeowner I believe the stains in the drain pan were likely from these air leaks that can happen over time with thermal expansion and contraction. This is not a major issue right now and everything seems to be working fine mechanically. Advised homeowner that we could take care of this on the next maintenance. Unit in good working order upon departure.

Schedule maintenance f
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Observed that there was no surge protection on the unit. I would advise adding surge protection to protect from blackouts brownouts and proximity lightning strikes. Surge protector cover up to $10,000 and related damages to surge on connected equipment. Everything was testing well with rega
Anna, TX 75409
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 
 
Observed that there was no surge protection on the unit. I would advise adding surge protection to protect from blackouts brownouts and proximity lightning strikes. Surge protector cover up to $10,000 and related damages to surge on connected equipment.
Everything was testing well with rega
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 
 
Observed that there was no surge protection on the unit. I would advise adding surge protection to protect from blackouts brownouts and proximity lightning strikes. Surge protector cover up to $10,000 and related damages to surge on connected equipment.
Everything was testing well with rega
Jesse V.
Jesse V.
Thank you again for the opportunity to visit your home and evaluate the humidity concerns you’ve been experiencing. I wanted to provide a summary of what we found during our visit and the recommendations that will help improve comfort and humidity control throughout the house. When I arrived, I began by evaluating the thermostat and airflow around it. I noticed the air purifier was positioned directly beneath the thermostat and was blowing air upward toward it. In addition, there is a supply air vent in the living room that is directing conditioned air toward the thermostat as well. With air blowing toward the thermostat from two different directions, it can cause the thermostat to receive inaccurate temperature and humidity readings. When this happens, the system may cycle improperly and struggle to regulate humidity levels effectively throughout the home. To correct this, I recommended relocating the air purifier to another area of the home away from the thermostat. I also sugges
Anna, TX 75409
Anna, TX - 
Thank you again for the opportunity to visit your home and evaluate the humidity concerns you’ve been experiencing. I wanted to provide a summary of what we found during our visit and the recommendations that will help improve comfort and humidity control throughout the house.

When I arrived, I began by evaluating the thermostat and airflow around it. I noticed the air purifier was positioned directly beneath the thermostat and was blowing air upward toward it. In addition, there is a supply air vent in the living room that is directing conditioned air toward the thermostat as well.

With air blowing toward the thermostat from two different directions, it can cause the thermostat to receive inaccurate temperature and humidity readings. When this happens, the system may cycle improperly and struggle to regulate humidity levels effectively throughout the home.

To correct this, I recommended relocating the air purifier to another area of the home away from the thermostat. I also sugges
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Filter was not changed with today’s visit as there was no filter provided. Owner advised me it was on order and on the way and that they would take care of the filter change themselves. Borrowed water from next door (crows) to rinse the outdoor unit with water to promote efficiency and perfo
Anna, TX 75409
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Filter was not changed with today’s visit as there was no filter provided. Owner advised me it was on order and on the way and that they would take care of the filter change themselves. Borrowed water from next door (crows) to rinse the outdoor unit with water to promote efficiency and perfo
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Filter was not changed with today’s visit as there was no filter provided. Owner advised me it was on order and on the way and that they would take care of the filter change themselves. Borrowed water from next door (crows) to rinse the outdoor unit with water to promote efficiency and perfo