Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in March 2026.

The most recent job was on March 20, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
I unwired the compressor and the breaker did not trip. I shut the system down , connected the compressor, and it tripped. I ohmed the compressor windings and discovered that the windings are bad. I attempted to start the compressor and it only pulls 58/147 on attempted start up. We will reach out to the manufacture ASAP to get this addressed.
Anna, TX 75409
Anna, TX - I unwired the compressor and the breaker did not trip. I shut the system down , connected the compressor, and it tripped. I ohmed the compressor windings and discovered that the windings are bad. I attempted to start the compressor and it only pulls 58/147 on attempted start up. We will reach out to the manufacture ASAP to get this addressed.
Anna, TX - I unwired the compressor and the breaker did not trip. I shut the system down , connected the compressor, and it tripped. I ohmed the compressor windings and discovered that the windings are bad. I attempted to start the compressor and it only pulls 58/147 on attempted start up. We will reach out to the manufacture ASAP to get this addressed.
Matthew C.
Matthew C.
I found on the main house unit that there is a small leak in the evaporator coil. Temp splits are still fine. But I also found that the blower motor is speeding up and slowing down when cooling. The unit did trip into a HP Lockout due to inadequate airflow error code. b9, there is not obstruction to the blower or in the duct work. So this indicates a failing ecm blower motor. Upon completion of thorough evaluation for both units. I found both units could benefit from a duct cleaning. As well as the garage unit needing an evaporator coil cleaning. Both could benefit from having the filters upgraded.
Anna, TX 75409
Anna, TX - I found on the main house unit that there is a small leak in the evaporator coil. Temp splits are still fine. But I also found that the blower motor is speeding up and slowing down when cooling. The unit did trip into a HP Lockout due to inadequate airflow error code. b9, there is not obstruction to the blower or in the duct work. So this indicates a failing ecm blower motor. Upon completion of thorough evaluation for both units. I found both units could benefit from a duct cleaning. As well as the garage unit needing an evaporator coil cleaning. Both could benefit from having the filters upgraded.
Anna, TX - I found on the main house unit that there is a small leak in the evaporator coil. Temp splits are still fine. But I also found that the blower motor is speeding up and slowing down when cooling. The unit did trip into a HP Lockout due to inadequate airflow error code. b9, there is not obstruction to the blower or in the duct work. So this indicates a failing ecm blower motor. Upon completion of thorough evaluation for both units. I found both units could benefit from a duct cleaning. As well as the garage unit needing an evaporator coil cleaning. Both could benefit from having the filters upgraded.
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found outdoor coil temp sensor wire severed. Measured capacitor was testing outside of manufacturer specifications. Recommend replacment to avoid system failure. Unit in good working order upon departure
Anna, TX 75409
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found outdoor coil temp sensor wire severed. Measured capacitor was testing outside of manufacturer specifications. Recommend replacment to avoid system failure. Unit in good working order upon departure
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found outdoor coil temp sensor wire severed. Measured capacitor was testing outside of manufacturer specifications. Recommend replacment to avoid system failure. Unit in good working order upon departure
Brayden W.
Brayden W.
Replaced motor under warranty. Tested unit after installation and found no issues. Measured return 77- supply 58. No further immediate issues at this time. Shared pictures of completed work to homeowner. Advised homeowner we would be doing a more through evaluation next week with the maintenance. Unit in good working order upon departure
Anna, TX 75409
Brayden W.
Brayden W.
Began inspection at indoor unit. Filter was replaced about a month ago and is not overly dirty but could use a change. Proceeded to outdoor unit and found the capacitor not entirely failed but testing well outside of manufacturer specifications 37/45. Also noted condenser coils are completely blocked by dust and debris. This will cause immense stress on the compressor as it cannot breathe properly. Tested compressor for resistance and got 77, 77 , 1 . This indicates a failed compressor. Compressor replacement under warranty Entails recapturing of old refrigerant unwiring and removal of old compressor. Braising a new filter dryer to filter refrigerant. Installing new compressor and wiring it up. Cleaning out refrigerant lines of contaminated refrigerant, Pressure testing refrigerant lines, and putting the refrigerant lines under a vacuum to 400 microns. Adding new uncontaminated refrigerant to the system and testing. Also includes capacitor replacement as the current one is testing
Anna, TX 75409
Anna, TX - Began inspection at indoor unit. Filter was replaced about a month ago and is not overly dirty but could use a change. Proceeded to outdoor unit and found the capacitor not entirely failed but testing well outside of manufacturer specifications 37/45. Also noted condenser coils are completely blocked by dust and debris. This will cause immense stress on the compressor as it cannot breathe properly. Tested compressor for resistance and got 77, 77 , 1 . This indicates a failed compressor. 

Compressor replacement under warranty

Entails recapturing of old refrigerant unwiring and removal of old compressor. Braising a new filter dryer to filter refrigerant. Installing new compressor and wiring it up. Cleaning out refrigerant lines of contaminated refrigerant, Pressure testing refrigerant lines, and putting the refrigerant lines under a vacuum to 400 microns. Adding new uncontaminated refrigerant to the system and testing. 

Also includes capacitor replacement as the current one is testing
Anna, TX - Began inspection at indoor unit. Filter was replaced about a month ago and is not overly dirty but could use a change. Proceeded to outdoor unit and found the capacitor not entirely failed but testing well outside of manufacturer specifications 37/45. Also noted condenser coils are completely blocked by dust and debris. This will cause immense stress on the compressor as it cannot breathe properly. Tested compressor for resistance and got 77, 77 , 1 . This indicates a failed compressor. 

Compressor replacement under warranty

Entails recapturing of old refrigerant unwiring and removal of old compressor. Braising a new filter dryer to filter refrigerant. Installing new compressor and wiring it up. Cleaning out refrigerant lines of contaminated refrigerant, Pressure testing refrigerant lines, and putting the refrigerant lines under a vacuum to 400 microns. Adding new uncontaminated refrigerant to the system and testing. 

Also includes capacitor replacement as the current one is testing
Shelby S.
Shelby S.
I performed 2 cooling maintenances on 2015 gas systems. I checked amps capacitors, filters, electrical, cleanliness, drains, and safeties. I discovered a few deficiencies with both systems. The downstairs system’s blower wheel has a reasonable amount of build up present. This causes drag on the motor and will result in premature failure. Both outdoor units need capacitors due to them being right at the bottom of the specification range. The upstairs unit’s flue pipe was not connected when I went into the attic space. Customer stated that they had their roof replaced after the heating maintenance was performed. The flue sits approximately 3 inches too far to the left now. I provided pictures of flue and the hole cut for it. I advised the customer to not run heating on the upstairs, and he stated that it doesn’t get used often. We will need to return with a 3” flexible flue pipe to repair.
Anna, TX 75409
Anna, TX - I performed 2 cooling maintenances on 2015 gas systems. I checked amps capacitors, filters, electrical, cleanliness, drains, and safeties. I discovered a few deficiencies with both systems. The downstairs system’s blower wheel has a reasonable amount of build up present. This causes drag on the motor and will result in premature failure. Both outdoor units need capacitors due to them being right at the bottom of the specification range. The upstairs unit’s flue pipe was not connected when I went into the attic space. Customer stated that they had their roof replaced after the heating maintenance was performed. The flue sits approximately 3 inches too far to the left now. I provided pictures of flue and the hole cut for it. I advised the customer to not run heating on the upstairs, and he stated that it doesn’t get used often. We will need to return with a 3” flexible flue pipe to repair.
Anna, TX - I performed 2 cooling maintenances on 2015 gas systems. I checked amps capacitors, filters, electrical, cleanliness, drains, and safeties. I discovered a few deficiencies with both systems. The downstairs system’s blower wheel has a reasonable amount of build up present. This causes drag on the motor and will result in premature failure. Both outdoor units need capacitors due to them being right at the bottom of the specification range. The upstairs unit’s flue pipe was not connected when I went into the attic space. Customer stated that they had their roof replaced after the heating maintenance was performed. The flue sits approximately 3 inches too far to the left now. I provided pictures of flue and the hole cut for it. I advised the customer to not run heating on the upstairs, and he stated that it doesn’t get used often. We will need to return with a 3” flexible flue pipe to repair.
Brayden W.
Brayden W.
Arrived on site customer stated unit was not cooling properly last night. Started by checking outdoor electrical. Capacitor and contactor were testing within manufacturer specifications. Turned unit on to cooling for testing. Observed blower running as designed and i could hear refrigerant pumping. Proceeding to the outdoor unit I found the condenser fan motor not spinning. Shut unit down at breaker to prevent damage and proceeded to test motor. Found start to common winding measuring 90ohms and both previous wires to L1 testing with no resistance. Ordered motor under parts warranty. Advised homeowner we would be able to come back out today to replace the motor as it is available for pick up today. Schedule maintenance Wednesday 10-12
Anna, TX 75409
Anna, TX - Arrived on site customer stated unit was not cooling properly last night. Started by checking outdoor electrical. Capacitor and contactor were testing within manufacturer specifications. Turned unit on to cooling for testing. Observed blower running as designed and i could hear refrigerant pumping. Proceeding to the outdoor unit I found the condenser fan motor not spinning. Shut unit down at breaker to prevent damage and proceeded to test motor. Found start to common winding measuring 90ohms and both previous wires to L1 testing with no resistance. Ordered motor under parts warranty. Advised homeowner we would be able to come back out today to replace the motor as it is available for pick up today. Schedule maintenance Wednesday 10-12
Anna, TX - Arrived on site customer stated unit was not cooling properly last night. Started by checking outdoor electrical. Capacitor and contactor were testing within manufacturer specifications. Turned unit on to cooling for testing. Observed blower running as designed and i could hear refrigerant pumping. Proceeding to the outdoor unit I found the condenser fan motor not spinning. Shut unit down at breaker to prevent damage and proceeded to test motor. Found start to common winding measuring 90ohms and both previous wires to L1 testing with no resistance. Ordered motor under parts warranty. Advised homeowner we would be able to come back out today to replace the motor as it is available for pick up today. Schedule maintenance Wednesday 10-12
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Performed dryer vent cleaning Found condenser was showing signs of oxidation and stubborn debris on the coil that rinsing would not remove. Contactor is showing signs of pitting on the contacts and start amps are measuring high. Found plenum seal leaking air and causing condensation in the
Anna, TX 75409
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Performed dryer vent cleaning 
 Found condenser was showing signs of oxidation and stubborn debris on the coil that rinsing would not remove. Contactor is showing signs of pitting on the contacts and start amps are measuring high. Found plenum seal leaking air and causing condensation in the
Anna, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Performed dryer vent cleaning 
 Found condenser was showing signs of oxidation and stubborn debris on the coil that rinsing would not remove. Contactor is showing signs of pitting on the contacts and start amps are measuring high. Found plenum seal leaking air and causing condensation in the
Shelby S.
Shelby S.
Discovered a loose connection from the thermostat on W. I fixed the connection and tested the system. The system is back to heating.
Anna, TX 75409
Anna, TX - Discovered a loose connection from the thermostat on W. I fixed the connection and tested the system. The system is back to heating.
Anna, TX - Discovered a loose connection from the thermostat on W. I fixed the connection and tested the system. The system is back to heating.
Shelby S.
Shelby S.
OZONE FREE Air Scrubber - Install an ionizing whole house air purification system to ensure a high standard of air quality. Need to add a 40a Transformer with part.
Anna, TX 75409
Anna, TX - OZONE FREE Air Scrubber - Install an ionizing whole house air purification system to ensure a high standard of air quality.  Need to add a 40a Transformer with part.
Anna, TX - OZONE FREE Air Scrubber - Install an ionizing whole house air purification system to ensure a high standard of air quality.  Need to add a 40a Transformer with part.

Your High Efficiency