Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in September 2026.

The most recent job was on September 10, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Skylar M.
Skylar M.
Customer was having concerns about system running and stopping off and on. System would run for about 5 min and then shut off. It would then go into a 5 min delay before it would run again. Took thermostat off wall and jumped the wires together, system stayed running for over 10 minutes. Customer had new thermostat, replaced the old one and programmed the settings. Tested system in cooling and system continue to run. System is cooling at this time.
Anna, TX 75409
Anna, TX - Customer was having concerns about system running and stopping off and on. System would run for about 5 min and then shut off. It would then go into a 5 min delay before it would run again. Took thermostat off wall and jumped the wires together, system stayed running for over 10 minutes. Customer had new thermostat, replaced the old one and programmed the settings. Tested system in cooling and system continue to run. System is cooling at this time.
Anna, TX - Customer was having concerns about system running and stopping off and on. System would run for about 5 min and then shut off. It would then go into a 5 min delay before it would run again. Took thermostat off wall and jumped the wires together, system stayed running for over 10 minutes. Customer had new thermostat, replaced the old one and programmed the settings. Tested system in cooling and system continue to run. System is cooling at this time.
Jesse V.
Jesse V.
NA
Anna, TX 75409
Skylar M.
Skylar M.
No cool on split heat pump system. On arrival, indoor blower was running but condenser was not. Checked voltage at contactor, getting 24v from air handler. Getting 240v to bottom of contactor but not at the top. Contactor is bad. Found ants had crawled inside and it was not sending voltage through. Replaced contactor and tested system. Checked refrigerant pressures and subcooling. System is cooling at this time.
Anna, TX 75409
Anna, TX - No cool on split heat pump system. On arrival, indoor blower was running but condenser was not. Checked voltage at contactor, getting 24v from air handler. Getting 240v to bottom of contactor but not at the top. Contactor is bad. Found ants had crawled inside and it was not sending voltage through. Replaced contactor and tested system. Checked refrigerant pressures and subcooling. System is cooling at this time.
Anna, TX - No cool on split heat pump system. On arrival, indoor blower was running but condenser was not. Checked voltage at contactor, getting 24v from air handler. Getting 240v to bottom of contactor but not at the top. Contactor is bad. Found ants had crawled inside and it was not sending voltage through. Replaced contactor and tested system. Checked refrigerant pressures and subcooling. System is cooling at this time.
Skylar M.
Skylar M.
Customer was having concerns about system not keeping up with thermostat. Checked temperature drop across coil and only getting 12° difference. Checked refrigerant pressures and system is low on refrigerant. Customer declined leak search and just wanted to add refrigerant. Added 3 lbs of refrigerant and temperature drop has increased to 19°. Sending estimate for leak search too in case the system stops working again.
Anna, TX 75409
Anna, TX - Customer was having concerns about system not keeping up with thermostat. Checked temperature drop across coil and only getting 12° difference. Checked refrigerant pressures and system is low on refrigerant. Customer declined leak search and just wanted to add refrigerant. Added 3 lbs of refrigerant and temperature drop has increased to 19°. Sending estimate for leak search too in case the system stops working again.
Anna, TX - Customer was having concerns about system not keeping up with thermostat. Checked temperature drop across coil and only getting 12° difference. Checked refrigerant pressures and system is low on refrigerant. Customer declined leak search and just wanted to add refrigerant. Added 3 lbs of refrigerant and temperature drop has increased to 19°. Sending estimate for leak search too in case the system stops working again.
Skylar M.
Skylar M.
Arrive for no cool. Customer stated breaker was tripping. Also before breaker was shutting off, system was not able to keep up with set temperature. Inspected breaker and determined that it won’t stay on its own. This will need to be replaced by an electrician. While we were there, connected gauges to system. It is completely empty. Customer is getting breaker fixed and then we will come out to check compressor and search for a leak. If leak is found in the coil, system will need to be replaced due to it being out of warranty and type of refrigerant. Talked with realtor and she is going to talk to the homeowners.
Anna, TX 75409
Anna, TX - Arrive for no cool. Customer stated breaker was tripping. Also before breaker was shutting off, system was not able to keep up with set temperature. Inspected breaker and determined that it won’t stay on its own. This will need to be replaced by an electrician. While we were there, connected gauges to system. It is completely empty. Customer is getting breaker fixed and then we will come out to check compressor and search for a leak. If leak is found in the coil, system will need to be replaced due to it being out of warranty and type of refrigerant. Talked with realtor and she is going to talk to the homeowners.
Anna, TX - Arrive for no cool. Customer stated breaker was tripping. Also before breaker was shutting off, system was not able to keep up with set temperature. Inspected breaker and determined that it won’t stay on its own. This will need to be replaced by an electrician. While we were there, connected gauges to system. It is completely empty. Customer is getting breaker fixed and then we will come out to check compressor and search for a leak. If leak is found in the coil, system will need to be replaced due to it being out of warranty and type of refrigerant. Talked with realtor and she is going to talk to the homeowners.
Skylar M.
Skylar M.
Return for system not cooling again. On arrival, outside unit was running but indoor blower was not, coil was frozen. Error code was for clogged drain line. Once I pulled float switch out, the blower came back on. The primary drain line is clogged up. When the float switch would trigger, it was only shutting the blower off but keeping the condenser running. This is what caused it to ice up. Cleared drain line using nitrogen. Poured water down it to verify it was clear. Wired float switch up to shut off the thermostat completely. This will shut everything off rather than only the blower. Tested float switch operation as well. System is cooling at this time and drain is clear.
Anna, TX 75409
Anna, TX - Return for system not cooling again. On arrival, outside unit was running but indoor blower was not, coil was frozen. Error code was for clogged drain line. Once I pulled float switch out, the blower came back on. The primary drain line is clogged up. When the float switch would trigger, it was only shutting the blower off but keeping the condenser running. This is what caused it to ice up. Cleared drain line using nitrogen. Poured water down it to verify it was clear. Wired float switch up to shut off the thermostat completely. This will shut everything off rather than only the blower. Tested float switch operation as well. System is cooling at this time and drain is clear.
Anna, TX - Return for system not cooling again. On arrival, outside unit was running but indoor blower was not, coil was frozen. Error code was for clogged drain line. Once I pulled float switch out, the blower came back on. The primary drain line is clogged up. When the float switch would trigger, it was only shutting the blower off but keeping the condenser running. This is what caused it to ice up. Cleared drain line using nitrogen. Poured water down it to verify it was clear. Wired float switch up to shut off the thermostat completely. This will shut everything off rather than only the blower. Tested float switch operation as well. System is cooling at this time and drain is clear.
Skylar M.
Skylar M.
Arrive for no cool on single system. Customer had coil freeze up over the weekend and stop cooling. After customer talked with Jesse they turned the unit off completely and tried to test the blower. At that time they did not think the blower was running. On arrival, I tested the blower on its own and then turned the system on to cool. Both times the blower came on and ran normally. Checked refrigerant pressures and system was cooling correctly. Subcooling was within acceptable range. Replaced filter, it was dirty but not sure if that caused the problem. Getting 75° at return and 56° at supply, system is cooling at this time and customer will let us know if it stops working again.
Anna, TX 75409
Anna, TX - Arrive for no cool on single system. Customer had coil freeze up over the weekend and stop cooling. After customer talked with Jesse they turned the unit off completely and tried to test the blower. At that time they did not think the blower was running. On arrival, I tested the blower on its own and then turned the system on to cool. Both times the blower came on and ran normally. Checked refrigerant pressures and system was cooling correctly. Subcooling was within acceptable range. Replaced filter, it was dirty but not sure if that caused the problem. Getting 75° at return and 56° at supply, system is cooling at this time and customer will let us know if it stops working again.
Anna, TX - Arrive for no cool on single system. Customer had coil freeze up over the weekend and stop cooling. After customer talked with Jesse they turned the unit off completely and tried to test the blower. At that time they did not think the blower was running. On arrival, I tested the blower on its own and then turned the system on to cool. Both times the blower came on and ran normally. Checked refrigerant pressures and system was cooling correctly. Subcooling was within acceptable range. Replaced filter, it was dirty but not sure if that caused the problem. Getting 75° at return and 56° at supply, system is cooling at this time and customer will let us know if it stops working again.
Skylar M.
Skylar M.
No cool on upstairs system. Customer stated that system was not cooling very well. Thermostat was set to 69° on arrival and was 72° upstairs. Checked temperature drop across system and getting 17° difference. Drain line is clear and float switch is not being tripped. Checked refrigerant pressures and subcooling was a little low. Customer approved adding 1 lb of refrigerant and seeing if this helps, declined leak search at this time. After adding refrigerant subcooling came up to an acceptable range. Temperature split dropped by 2° as well. Thermostat is down to 71° after system has been running while we were working. System is cooling at this time.
Anna, TX 75409
Anna, TX - No cool on upstairs system. Customer stated that system was not cooling very well. Thermostat was set to 69° on arrival and was 72° upstairs. Checked temperature drop across system and getting 17° difference. Drain line is clear and float switch is not being tripped. Checked refrigerant pressures and subcooling was a little low. Customer approved adding 1 lb of refrigerant and seeing if this helps, declined leak search at this time. After adding refrigerant subcooling came up to an acceptable range. Temperature split dropped by 2° as well. Thermostat is down to 71° after system has been running while we were working. System is cooling at this time.
Anna, TX - No cool on upstairs system. Customer stated that system was not cooling very well. Thermostat was set to 69° on arrival and was 72° upstairs. Checked temperature drop across system and getting 17° difference. Drain line is clear and float switch is not being tripped. Checked refrigerant pressures and subcooling was a little low. Customer approved adding 1 lb of refrigerant and seeing if this helps, declined leak search at this time. After adding refrigerant subcooling came up to an acceptable range. Temperature split dropped by 2° as well. Thermostat is down to 71° after system has been running while we were working. System is cooling at this time.
Skylar M.
Skylar M.
1 system AC maintenance. Replaced filter provided by customer. Measured temperature drop across system, getting 19° difference. Checked operation of drain line, it is clear and treated with drain solution. Next, went outside to condenser. Measured amp draw on compressor and fan motor. Starting amp draw on compressor is above manufacturer limit, this causes more stress on the compressor and can shorten the life of it. Recommended installing hard start kit to bring starting amps down and prolong the life of the compressor. Checked capacitor and contactor. Capacitor is out of range, replaced it under parts warranty. Cleaned condenser coil using water. System is cooling at this time.
Anna, TX 75409
Anna, TX - 1 system AC maintenance. Replaced filter provided by customer. Measured temperature drop across system, getting 19° difference. Checked operation of drain line, it is clear and treated with drain solution. Next, went outside to condenser. Measured amp draw on compressor and fan motor. Starting amp draw on compressor is above manufacturer limit, this causes more stress on the compressor and can shorten the life of it. Recommended installing hard start kit to bring starting amps down and prolong the life of the compressor. Checked capacitor and contactor. Capacitor is out of range, replaced it under parts warranty. Cleaned condenser coil using water. System is cooling at this time.
Anna, TX - 1 system AC maintenance. Replaced filter provided by customer. Measured temperature drop across system, getting 19° difference. Checked operation of drain line, it is clear and treated with drain solution. Next, went outside to condenser. Measured amp draw on compressor and fan motor. Starting amp draw on compressor is above manufacturer limit, this causes more stress on the compressor and can shorten the life of it. Recommended installing hard start kit to bring starting amps down and prolong the life of the compressor. Checked capacitor and contactor. Capacitor is out of range, replaced it under parts warranty. Cleaned condenser coil using water. System is cooling at this time.
Skylar M.
Skylar M.
No cool on main system. Customer stated that system was struggling to keep up with temperature. Checked temperature split and only getting 6° difference. Checked refrigerant pressure and they seemed very low or that the coil was frozen. Took panel off coil and it was not frozen at all. Verified system had proper air flow and evaporator coil was not dirty. Turned system back on with door off and found that refrigerant was getting stopped at the TXV and causing liquid line to freeze. TXV needs to be replaced under warranty. Office is ordering part and will reach out to customer when it arrives.
Anna, TX 75409
Anna, TX - No cool on main system. Customer stated that system was struggling to keep up with temperature. Checked temperature split and only getting 6° difference. Checked refrigerant pressure and they seemed very low or that the coil was frozen. Took panel off coil and it was not frozen at all. Verified system had proper air flow and evaporator coil was not dirty. Turned system back on with door off and found that refrigerant was getting stopped at the TXV and causing liquid line to freeze. TXV needs to be replaced under warranty. Office is ordering part and will reach out to customer when it arrives.
Anna, TX - No cool on main system. Customer stated that system was struggling to keep up with temperature. Checked temperature split and only getting 6° difference. Checked refrigerant pressure and they seemed very low or that the coil was frozen. Took panel off coil and it was not frozen at all. Verified system had proper air flow and evaporator coil was not dirty. Turned system back on with door off and found that refrigerant was getting stopped at the TXV and causing liquid line to freeze. TXV needs to be replaced under warranty. Office is ordering part and will reach out to customer when it arrives.

Your High Efficiency

Experts