Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX between August 2026 and September 2026.
The most recent job was on September 3, 2026.
Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
Customer was having concerns about water dripping out of pipe in soffit. Found that there was water draining into secondary drain pan from secondary drain on coil. Primary drain line is clogged up and water is backing up in two secondary drain. Cut drain line and cleared it using high-pressure nitrogen. Poured water down drain line to verify it is clear. System is cooling at this time.
No cool on single system house. Indoor blower motor was running but compressor was not. Checked capacitor and it was completely dead. Customer approved replacement of capacitor using upgraded turbo with 5 year warranty. Tested system after repair. Measured amp draw on compressor and fan motor. System is cooling at this time.
Replaced discharge air temperature sensor for Honeywell zone board. After installing new sensor, tested system with only upstairs zone calling. System did not shut off and continued to run the condenser. Checked refrigerant pressures and subcooling. System is a little low on refrigerant which can cause the system to run longer and not keep up with the temperature. Customer declined adding refrigerant at this time but might move forward with it in the future. System is cooling at this time.
Customer was having concerns about system short cycling when upstairs zone is calling. Honeywell zone board is shutting unit off because discharge air temperature sensor is interrupting the signal to the condenser. Static pressure is high because unit is only 1 stage and cannot slow its blower speed down when only 1 zone is calling. Dampers are all opening correctly. After speaking with manager, he stated the temperature sensors tend to go bad and that is why it keeps shutting the unit off. Recommend replacing temperature sensor first before trying to look into ductwork modification.
1 system AC maintenance. Checked filters, customer replaced them and they are still good. Measured amp draw on blower motor. Checked temperature split across coil, getting 19° drop. Checked operation of drain lines. Poured water down them and also treated them with drain solution. Next, went outside to condenser. Measured amp draw on compressor and fan motor. Checked capacitor and contactor, both are within acceptable range. Starting amp draw on compressor is at manufacturer limits which can cause the compressor to fail prematurely. Recommend adding hard start kit to bring starting amps down and prolong life of the compressor. Cleaned condenser coil using water. System is cooling at this time.
1 system AC maintenance. Replaced filter provided by customer. Treated drain line with drain solution. When flushing it with water it back up. Found that bathroom sink was clogged so customer is first going to get sink fixed and then if we have to come back out as well we will. Measured temperature drop across system, getting 20° difference. Checked amp draw on compressor and fan motor. Measured capacitor, it is very low and needs to be replaced. Checked starting amp draw on compressor and it is amping higher than manufacturer limits. This will put more stress on compressor. Recommend adding hard start kit to help jump start compressor and prolong the life of the unit. Cleaned condenser coil using water. System is cooling at this time. Performed QC on new install. Checked drain lines and they are clear. Measured temperature drop across system, getting 21° difference. System in attic is completely sealed with no air leaks. System is level and drains are sloped correctly. Checked refri
Customer had concerns about water draining into his closet. Found that primary drain was clogged and water was overflowing the unit’s drain pan. Cleared drain line using nitrogen. Watched all water that was trapped in unit drain out and poured more water down line to make sure it was clear. Set system back on and it is cooling at this time.
2 system AC maintenance. Customer just cleaned reusable filters. Downstairs system was having issues with water in the drain pan. Found that primary drain line was clogged up and water was backing up into pan. Cleaned drain line using nitrogen. Poured water down it to verify it was clear and then treated it with drain solution. Measured temperature drop across both systems. Downstairs system is struggling and only getting 17° difference. Checked blower wheels. Both of them have a lot of buildup and this affects the performance and efficiency of the systems. Recommend having them pulled out and cleaned. Checked amp draw on compressors and fan motors. Checked capacitors, they are both within acceptable range. Systems do not use contactors. Cleaned condenser coils using water. Refrigerant pressures on downstairs system are slightly low, which is contributing to the air not getting cold enough. Recommend performing leak search to see if there is a leak or if it just needs to be topped off.
Arrive for no cool. Indoor and outdoor units were running but system was not cooling. Checked refrigerant pressures and they were very low. Home owner elected to add 4 lbs of refrigerant to the system. Once that was done she approved a leak search on the system to find the reason there was no refrigerant. Found leak in the evaporator coil. Checked warranty status and it has expired. System will need to be replaced.
Arrive for no cool. Set thermostat to cool and indoor blower comes on but blows warm air. Went outside to condenser and it is not running. Contactor is pulled in so it is getting correct voltage. Checked capacitor and it is swollen and dead. Replaced it with turbo capacitor that comes with 5 year warranty. Powered disconnect on and condenser started running. Measured amp draw on compressor and fan motor. Checked temperature drop across system, 81° return and 61° supply. System is cooling at this time.