Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in April 2025.
The most recent job was on April 14, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
I arrived at our clients home for a single system cooling maintenance inspection. I began by looking at the indoor unit and discussing the potential lack of return air in the closet unit. We also discussed hot/cold spots in the home. I proceeded outside and began to test the electrical components of the heat pump. I found the capacitor to be below manufacture specifications for the compressor and subsequently it is causing the unit to have very high start amps. The start amps are exceeding the manufacture limit. It is also causing the contactor to have burn/arching on the connection points. I also showed this to our client and we discussed the option of replacing these components under warranty. The unit was manufactured in May and only has a 5 yr limited warranty. We also discussed adding a hard start kit onto the compressor to help reduce the amount of start amps and help the performance of the compressor motor. I went back inside and tested the blower motor amps and temperature
Reformed single system cooling maintenance. I checked amps, capacitor, filter, cleanliness, drains, ducts, safeties, temperature differential, and refrigerant temperature. The system is cooling mostly in manufacture specifications. The compressor is over amping on start up. This leads to internal damage over years resulting in the compressor failing. The ducts are poorly designed. This is causing poor airflow to the master portion of the house and a whistling noise coming from one of the return. The duct to the master area is a 9” that feeds 2 - 7” ducts. We need to upsize the duct to a 12”. This would allow us to supply the 7s with appropriate air flow. The systems are designed to have so much return air. The system currently does not have enough. This causes high static pressure and it is one of the leading causes of system failure. High static pressure strains all of the major parts of an air conditioner. Provided pricing to address noticed issues.
Performed a 1 system spring maintenance ( ). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,,, highly recommend a surge protector for the outdoor unit to protect it against over current. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty,,,return plenum/ ductwork are dusty, recommended a duct cleaning. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. Found no issues/ concerns at this time , unit is working properly.
Arrived on site, customer stated all is well in regards to normal unit operation however, she has not turned the system onto AC for the year. Began system inspection at the air handler. Upon initial inspection, it was noticed that the air filter had a poor fit, allowing dust past the filter. Lower motor amps were testing within range. Blower motor is beginning to accumulate a decent amount of dust which will shorten the life of the motor. Also noticed bacterial growth inside the unit. Tested drain line and float switch everything working fine. However there is no float. Switch on the primary drain line or blowout valve. On the outdoor unit contactor was testing within range. Capacitor was testing just below range on both fan and compressor. Start and run amps were within range. Washed outdoor unit to promote heat exchange and unit efficiency. Recommendations: 1. Replace capacitor testing outside range expected to fail soon Causing premature system Failure 2. blower motor Cleaning to r
Performed a 1 system spring maintenance (gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw,,, recommended a surge protector to prevent any over current damage to the condenser unit. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty,,, return plenum/ ductwork are very dirty, highly recommended a duct cleaning. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,,both are dusty highly recommended a blower cleaning. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines,,,there is an overflow switch installed on the emergency drain pan but we recommend to install a different overflow switch on the mai
Install to be scheduled once part and materials are collected.
Arrived at our clients home for a single system cooling maintenance inspection. Our client had one last filter in the attic which I replaced today. Once replaced I proceeded outside to test and inspect the electrical components of the condenser unit. The capacitor is showing early signs of failure and I did find the compressor to have extremely high start amps. I showed this to our client and we discussed the option of adding a hard start kit. I then went into the attic and tested the blower motor amps and ensured the unit was cooling properly. The secondary drain pan is very rusted with small rust spots penetrating through. The unit is also without a blow out valve and water safety switch. I showed this to our client and he elected to replace and install a new drain pan with flex seal, a ball valve and float switch. He also elected to install the hard start kit today. Once installed I showed him how much the unit start amps had dropped. I then scheduled the replacement drain pan for n
Arrived for a single system maintenance inspection. Our client provided a filter to be replaced today. Once replaced I proceeded outside to test and inspect the outdoor heat pump. I tested all the electrical components and ensured everything was within manufacture specifications. Everything passed today. I then went into the attic and checked the blower motor and supply temperature. Inside everything also passed inspection. The only item that concerned me was that the system does not have a water safety switch to shutoff the system if there is a clog in the drain line. I showed this to our client and she requested an estimate for the float switch. The unit is otherwise cooling properly.
Attempted to locate the source of the leak. The source could not be determined at the time of service due to the gas metering being locked out. We need the ability to turn it on to find the source of the leak. Collected service fee and reached out to the CFO to have her reach out to the gas company. While on the roof, I shut the gas cocks in what appears to be off. We will return once we have the ability to turn on the gas when needed.
I ran the air advise and looked through the furnace. I provided options to address an allergy issue. These options consisted of upgrading filtration, air scrubber, blower cleaning, and evaporator coil biocide treatment. I presented the Airscrubber audio book. Customer would like to discuss with her husband.