Menu

HVAC Service in Frisco, TX

Frisco has grown faster than almost any city in America over the past two decades, and the homes here reflect it. Larger floor plans, multi-zone systems, high-efficiency equipment, and newer construction in neighborhoods like The Fields, Phillips Creek Ranch, and Viridian. Keeping all of it running well takes an HVAC company that knows what it’s doing. Adon Complete Air Conditioning and Heating has been running calls for HVAC service in Frisco for years from our home base in Anna, just up the Dallas North Tollway corridor. We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in FriscoCall (903) 482-4900

What We Do for Frisco Homeowners

AC Repair. We diagnose and repair all makes and models. Frisco’s newer construction often means multi-zone systems and communicating equipment — our technicians know how to work on all of it.

AC Installation. When it’s time to replace, we size every system correctly using a proper load calculation. That matters especially in Frisco’s larger homes where an improperly sized system will short-cycle and leave rooms uncomfortable. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Frisco homeowners with high-end systems, staying on a maintenance schedule is one of the best ways to protect your investment.

Mini-Split Installation. Garages, home offices, casitas, and bonus spaces are common in Frisco’s larger homes. Mini-splits handle these spaces cleanly without touching your central system.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from one system and work well in North Texas’s climate. A practical choice for Frisco homeowners upgrading to a more efficient setup.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening. Frisco’s tight construction means less natural ventilation, making air quality systems more important than in older homes.

Air Duct Cleaning. Even newer ductwork accumulates contaminants over time. Professional duct cleaning improves air quality and keeps your system running efficiently throughout the home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. In a larger Frisco home, that adds up fast. We inspect, repair, and seal ductwork throughout the area.

Why Frisco Homeowners Choose Adon Complete

Frisco has no shortage of HVAC companies competing for business. Here’s why our customers keep calling us back.

We know multi-zone and communicating systems. The job notes from our Frisco calls show what we actually work on here – damper adjustments, multi-system diagnostics, communicating Trane equipment, humidity management in two-story homes. This isn’t routine work, and we handle it well.

Jesse Villarreal has over 27 years of experience. He’s the owner and is directly involved in how the business operates. When something goes wrong, you’re dealing with a company where the owner’s reputation is on the line.

We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained on the brands most common in Frisco’s newer construction. Full manufacturer warranty on every system we install.

The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. Straightforward and affordable.

Serving Frisco and Surrounding Collin County Communities

We serve all of Frisco, including The Fields, Phillips Creek Ranch, Viridian, Stonebriar, and the established neighborhoods along Preston Road and the Dallas North Tollway. We also serve the surrounding communities of Allen, McKinney, Anna, Melissa, and Sherman.

Schedule HVAC Service in FriscoCall (903) 482-4900

Frequently Asked Questions

Here are some common questions we get about our HVAC services in Frisco.

How much does AC repair cost in Frisco, TX?

Most AC repairs in Frisco run between $150 and $600 depending on the type of repair. Frisco’s newer homes often have multi-zone systems and higher-end equipment, which can affect parts costs. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you service multi-zone systems in Frisco?

Yes. Multi-zone systems and communicating HVAC equipment are common in Frisco’s larger homes, and our technicians work on them regularly. We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, and more.

Do you offer HVAC maintenance plans in Frisco?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. Preventive maintenance is especially important for the multi-system setups common in Frisco’s larger homes.

Do you offer emergency HVAC service in Frisco?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Frisco. When you call after hours, you reach a real person who can get a technician to your home fast.

What areas near Frisco do you serve?

We serve all of Frisco and the surrounding communities including Allen, McKinney, Anna, Melissa, and Sherman.

Ready to Get Your System Serviced?

Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online for HVAC services in Frisco. We handle everything from routine maintenance to emergency repairs throughout Frisco and Collin County.

Schedule HVAC Service in FriscoCall (903) 482-4900

Recent Jobs and Reviews in Frisco, TX

Rated 5.0 out of 5 stars based on 7 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Frisco, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Frisco, TX between June 2026 and July 2026.

The most recent job was on July 31, 2026.

Adon Complete Air Conditioning and Heating has completed 51 jobs in Frisco, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Skylar M.
Skylar M.
Customer was having concerns about system randomly shutting off for 30 seconds and coming back on. Thermostat does not lose power and it shows that it is still cooling but indoor blower is not running. Checked amp draw on blower motor and it is within acceptable range. Unable to recreate the problem after multiple tries and waiting for the unit to run. Customer is going to monitor the system to see if the outside unit is running when the indoor blower stops. Customer would like estimate for price of new blower motor just in case.
Frisco, TX 75034
Frisco, TX - Customer was having concerns about system randomly shutting off for 30 seconds and coming back on. Thermostat does not lose power and it shows that it is still cooling but indoor blower is not running. Checked amp draw on blower motor and it is within acceptable range. Unable to recreate the problem after multiple tries and waiting for the unit to run. Customer is going to monitor the system to see if the outside unit is running when the indoor blower stops. Customer would like estimate for price of new blower motor just in case.
Frisco, TX - Customer was having concerns about system randomly shutting off for 30 seconds and coming back on. Thermostat does not lose power and it shows that it is still cooling but indoor blower is not running. Checked amp draw on blower motor and it is within acceptable range. Unable to recreate the problem after multiple tries and waiting for the unit to run. Customer is going to monitor the system to see if the outside unit is running when the indoor blower stops. Customer would like estimate for price of new blower motor just in case.
Skylar M.
Skylar M.
Removed old condenser fan motor. Installed new one and tested operation. Measured amp draw on fan motor, it is with it acceptable rage. System is cooling at this time. Condenser coils are very dirty, let customer know and he will call to have summer maintenance scheduled.
Frisco, TX 75036
Frisco, TX - Removed old condenser fan motor. Installed new one and tested operation. Measured amp draw on fan motor, it is with it acceptable rage. System is cooling at this time. Condenser coils are very dirty, let customer know and he will call to have summer maintenance scheduled.
Frisco, TX - Removed old condenser fan motor. Installed new one and tested operation. Measured amp draw on fan motor, it is with it acceptable rage. System is cooling at this time. Condenser coils are very dirty, let customer know and he will call to have summer maintenance scheduled.
Skylar M.
Skylar M.
No cool on upstairs system. Breaker was tripping every time condenser would try to run. Through elimination found the condenser fan motor was tripping the breaker. Also found burn marks right at the motor where the wiring comes out. Need to get condenser fan motor and come out to replace it.
Frisco, TX 75036
Frisco, TX - No cool on upstairs system. Breaker was tripping every time condenser would try to run. Through elimination found the condenser fan motor was tripping the breaker. Also found burn marks right at the motor where the wiring comes out. Need to get condenser fan motor and come out to replace it.
Jesse V.
Jesse V.
Upon arrival, homeowner explained to me that certain areas of the house seemed much warmer. I found that the thermostat said the indoor humidity was 62%. I recalibrated both upstairs and downstairs thermostats. I change the settings for the dehumidification option. I also set a longer runtime on the lower when the system satisfies at set point. I looked at the system in the attic and tested drain line. Drains for draining properly. I adjusted one damper that was supplying the common area upstairs with too much air. I diverted that air to a daughter‘s bedroom because she didn’t seem to be getting enough air flow. Homeowner will give it 48 hours to see if this fixes all of the issues both systems were running properly.
Frisco, TX 75036
Frisco, TX - Upon arrival, homeowner explained to me that certain areas of the house seemed much warmer. I found that the thermostat said the indoor humidity was 62%. I recalibrated both upstairs and downstairs thermostats. I change the settings for the dehumidification option. I also set a longer runtime on the lower when the system satisfies at set point. I looked at the system in the attic and tested drain line. Drains for draining properly. I adjusted one damper that was supplying the common area upstairs with too much air. I diverted that air to a daughter‘s bedroom because she didn’t seem to be getting enough air flow. Homeowner will give it 48 hours to see if this fixes all of the issues both systems were running properly.
Frisco, TX - Upon arrival, homeowner explained to me that certain areas of the house seemed much warmer. I found that the thermostat said the indoor humidity was 62%. I recalibrated both upstairs and downstairs thermostats. I change the settings for the dehumidification option. I also set a longer runtime on the lower when the system satisfies at set point. I looked at the system in the attic and tested drain line. Drains for draining properly. I adjusted one damper that was supplying the common area upstairs with too much air. I diverted that air to a daughter‘s bedroom because she didn’t seem to be getting enough air flow. Homeowner will give it 48 hours to see if this fixes all of the issues both systems were running properly.
Clayton P.
Clayton P.
Upon arrival, I found that both drain lines were clogged. I installed a Jones valve or blowout valve. I had to use the nitrogen drain dog several times in order to finally get it unclogged. I tested drain lines several times with a gallon of water. At this time drain lines are draining properly. I also treated both drain lines with total C.
Frisco, TX 75035
Jesse V.
Jesse V.
Service Summary Discussed the current condition of the customer’s upstairs HVAC system, which is approximately 11 years old and uses R-410A refrigerant. After reviewing the available repair and replacement options, the customer has decided not to move forward with any major repairs or equipment replacement at this time. Per the customer’s request, the only service authorized was to check and top off the R-410A refrigerant charge on the upstairs system to restore the refrigerant level to the manufacturer’s recommended operating specifications. The customer understands that adding refrigerant is not a permanent repair if a leak is present and that additional refrigerant loss may occur over time. At this time, the customer has elected to continue operating the existing system and monitor its performance. -———————————————————————————————————- Service Summary – Master Bedroom & Upstairs HVAC System Upon inspection, the master bedroom condensate drain line was found to be severely clogg
Frisco, TX 75034
Frisco, TX - Service Summary

Discussed the current condition of the customer’s upstairs HVAC system, which is approximately 11 years old and uses R-410A refrigerant. After reviewing the available repair and replacement options, the customer has decided not to move forward with any major repairs or equipment replacement at this time.

Per the customer’s request, the only service authorized was to check and top off the R-410A refrigerant charge on the upstairs system to restore the refrigerant level to the manufacturer’s recommended operating specifications.

The customer understands that adding refrigerant is not a permanent repair if a leak is present and that additional refrigerant loss may occur over time. At this time, the customer has elected to continue operating the existing system and monitor its performance.

-———————————————————————————————————-
Service Summary – Master Bedroom & Upstairs HVAC System

Upon inspection, the master bedroom condensate drain line was found to be severely clogg
Frisco, TX - Service Summary

Discussed the current condition of the customer’s upstairs HVAC system, which is approximately 11 years old and uses R-410A refrigerant. After reviewing the available repair and replacement options, the customer has decided not to move forward with any major repairs or equipment replacement at this time.

Per the customer’s request, the only service authorized was to check and top off the R-410A refrigerant charge on the upstairs system to restore the refrigerant level to the manufacturer’s recommended operating specifications.

The customer understands that adding refrigerant is not a permanent repair if a leak is present and that additional refrigerant loss may occur over time. At this time, the customer has elected to continue operating the existing system and monitor its performance.

-———————————————————————————————————-
Service Summary – Master Bedroom & Upstairs HVAC System

Upon inspection, the master bedroom condensate drain line was found to be severely clogg
Shelby S.
Shelby S.
Upon arrival, I discovered the float switch tripped on the downstairs system. This is due to the drains being tied together, and the downstairs system being lower than the upstairs. I isolated the 2 systems and cleared the primary drain line. Afterwards, I tested the drain with water to ensure it was not leaking and drains properly. The client opted to sign up for a monthly service agreement and drains properly clearing. The systems are draining upon departure.
Frisco, TX 75035
Frisco, TX - Upon arrival, I discovered the float switch tripped on the downstairs system. This is due to the drains being tied together, and the downstairs system being lower than the upstairs. I isolated the 2 systems and cleared the primary drain line. Afterwards, I tested the drain with water to ensure it was not leaking and drains properly. The client opted to sign up for a monthly service agreement and drains properly clearing. The systems are draining upon departure.
Frisco, TX - Upon arrival, I discovered the float switch tripped on the downstairs system. This is due to the drains being tied together, and the downstairs system being lower than the upstairs. I isolated the 2 systems and cleared the primary drain line. Afterwards, I tested the drain with water to ensure it was not leaking and drains properly. The client opted to sign up for a monthly service agreement and drains properly clearing. The systems are draining upon departure.
Clever M.
Clever M.
Completed 1 system cooling tune up. Checked all critical components. Found both drainlines clogged. Unclogged both lines and had to release at sink to dislodge built up debris in line. Units now unclogged and draining properly.
Frisco, TX 75035
Frisco, TX - Completed 1 system cooling tune up. Checked all critical components. Found both drainlines clogged. Unclogged both lines and had to release at sink to dislodge built up debris in line. Units now unclogged and draining properly.
Frisco, TX - Completed 1 system cooling tune up. Checked all critical components. Found both drainlines clogged. Unclogged both lines and had to release at sink to dislodge built up debris in line. Units now unclogged and draining properly.
Clever M.
Clever M.
Completed fan motor replacement. After start up I checked system and verified cooling. Unit is operating normally at this time. M/B 80 degrees but will cool down in time.
Frisco, TX 75034
Frisco, TX - Completed fan motor replacement. After start up I checked system and verified cooling. Unit is operating normally at this time. M/B 80 degrees but will cool down in time.
Frisco, TX - Completed fan motor replacement. After start up I checked system and verified cooling. Unit is operating normally at this time. M/B 80 degrees but will cool down in time.
Brayden W.
Brayden W.
Arrived on site master bedroom unit was blowing air but not cooling. Found high pressure switch tripped. Reset and tested unit again. Unit came on and outdoor fan motor did not. Upon further testing it was found that the motor was seized. Adjusted capacitor terminal from 4mfd to 6mfd and added lubricant to motor shaft. With these adjustments I was able to get the motor moving again, but advised homeowner I cannot know for how long it will last. Advised replacing motor to avoid system failure. Spoke with manufacturer and they advised me it would take about a week to get the motor in from Arkansas. Homeowner elected to go forward with motor replacement. Advised we would order motor as soon as possible and update her with more information as soon as we have more. Also replaced thermostat with programmable Honeywell. Programmed thermostat to system speciations. Homeowner advised me they would like to set up the time blocks and set points themselves. System running upon departure.
Frisco, TX 75034
Frisco, TX - Arrived on site master bedroom unit was blowing air but not cooling. Found high pressure switch tripped. Reset and tested unit again. Unit came on and outdoor fan motor did not. Upon further testing it was found that the motor was seized. Adjusted capacitor terminal from 4mfd to 6mfd and added lubricant to motor shaft. With these adjustments I was able to get the motor moving again, but advised homeowner I cannot know for how long it will last. Advised replacing motor to avoid system failure. Spoke with manufacturer and they advised me it would take about a week to get the motor in from Arkansas. Homeowner elected to go forward with motor replacement. Advised we would order motor as soon as possible and update her with more information as soon as we have more. 

Also replaced thermostat with programmable Honeywell. Programmed thermostat to system speciations. Homeowner advised me they would like to set up the time blocks and set points themselves. 

System running upon departure.
Frisco, TX - Arrived on site master bedroom unit was blowing air but not cooling. Found high pressure switch tripped. Reset and tested unit again. Unit came on and outdoor fan motor did not. Upon further testing it was found that the motor was seized. Adjusted capacitor terminal from 4mfd to 6mfd and added lubricant to motor shaft. With these adjustments I was able to get the motor moving again, but advised homeowner I cannot know for how long it will last. Advised replacing motor to avoid system failure. Spoke with manufacturer and they advised me it would take about a week to get the motor in from Arkansas. Homeowner elected to go forward with motor replacement. Advised we would order motor as soon as possible and update her with more information as soon as we have more. 

Also replaced thermostat with programmable Honeywell. Programmed thermostat to system speciations. Homeowner advised me they would like to set up the time blocks and set points themselves. 