McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between April 2026 and June 2026.
The most recent job was on June 2, 2026.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
Customer only wanted me to get the system operational. The system likely needs another 2 pounds. The system I worked on was the downstairs. It is a gas system from 2013. Return temp is 74.5 and supply is 57.5
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage Outdoor electrical is all testing within manufacturer spec. Outdoor coils are extremely matted and dirty. This will cause an airflow restriction as well as block the heat exchange from happening efficiently. This causes stress on the refrigerant cycle and
Found leak in the evaporator coil. Client elected to have coil replaced under warranty.
I performed a single cooling maintenance on a 2020 dual fuel system. This system was brought into service in 2021. It is zoned and communicating. I checked amps, filter, electrical, cleanliness, and safeties. Due to the equipments past history, I advise adding a surge protector in the attic to prevent damage. I revisited the return cut in with the customer, and I offered to clean their filter.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Found outdoor unit with extreme amount of dust in debris coating the coils. After rinsing with water coils w
Upon arrival found the lennox unit to not be running. I proceeded upstairs where I found both the primary and secondary float switches to be tripped due to a clogged drain line. Presented issue to client. Client approved to have drain line and drain pan cleared of clog and water.
Tested temperature split and found supply only around 58-59. Tested refrigerant pressures and found system to be low. Found leak in the evaporator coil for master bedroom. Advised homeowner it was covered under parts warranty the only things he would be responsible for are refrigerant, new filter dryer, and labor. Office sent error to me that I was not seeing on this unit found den unit displaying error for amient temp sensor. Reviewed outdoor wiring and found sensor chewed by rodents. Measured ohms and found OL indicated the wire is severed somewhere. Provided options to homeowner for coil replacement and sensor replacement. Both systems running upon departure
.
5/21 - I returned to install a surge protector. The surge protector is installed and active. The system is operational upon departing. 3 year warranty / up to 10,000.00 coverage if part fails to protect the connected equipment. (Warranty is through manufacturer)
I performed a single cooling maintenance on a 2020 Daikin mini split. I thoroughly examined cleanliness, operation, drains, and electrical. During my drain testing, I discovered that the unit drips water from the bottom right corner when too much water is present. I quickly investigated and found that the drain pan is cracked. To properly address this, we need to remove the evaporator coil to replace the drain pan. Customer decided that it currently was not a big enough issue to proceed with a repair. I noticed that the equipment does not have surge protection. Mini splits are very susceptible to surge damage. I offered to install a surge protector at the time of service.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. No filters provided today. Advised homeowner to replace filters. Filter sizes are aprilaire 210 & 410. Obs
Exhaust pipe for be toilet room is crushed and broken. The only part where the air could flow was covered in insulation. Customer approved cutting apart the vent to open it back up and secure it with metal tape. I provided a service agreement pamphlet to the customer upon departure.
The condensing coil fins have sustained damage. This is causing an air restriction and puts additional wear on the compressor and condenser fan motor. **Could’ve been caused by a hail storm, but origin of the damage is unknown**
I performed a cooling maintenance on a 2017 zoned heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, safeties, and rinsed the outdoor unit. During my thorough evaluation, I determined that the system has a couple issues. The primary drain line is having a slow drain issue, the outdoor capacitor failed testing due to out of range charge, the compressor is starting with a high amp load, and the outdoor unit is in need of a deep cleaning due to stubborn debris and oxidation. I made the customer aware and presented options to address these issues at the time of service.
I performed a single cooling maintenance on a 2021 zoned communicating Amana heat pump. During my thorough evaluation, I did not discover any mechanical issues that needing addressing. However, I did discover that the outdoor condenser coils is damaged and needs a chemical bath to remove oxidation. I provided an option to address these two areas of concern during the time of service. Customer elected to perform the coil combing and algae stick. Customer would like to schedule next week and time does not matter.
2011 furnace and condenser carrier outdoorHomeowner complained system was not keeping up the way it used to. Turned unit onto cooling and checked refrigerant pressures. Pressures were very low indicating there is a leak in the system. I could not see any obvious leak in the outdoor coil or service valves meaning it is likely in the attic evaporator coil. Advised homeowner we would need to charge for a leak search in the evaporator coil to confirm but it is more than likely that this is where the leak is. Found capacitor dated from 2011 and is liable to fail at anytime. Outdoor condenser coil is very dirty and could have contributed to the leak. Notice ductwork in attic was missing insulation. Also found gas leak in downstairs unit’s furnace. Shut off gas and informed homeowner. Blower wheel is extremely dirty and in need of chemical cleaning. Advised homeowner that this coil is not under warranty and 410a equipment is being phased out. This makes the coils difficult to obtain if we can
Performed 4 system cooling maintenance on gas equipment. Checked amps, capacitors, filters, drains, cleanliness, and safeties. Left side downstairs unit needs a capacitor replacement due to it beginning to fail. This part is responsible for starting the outdoor unit. Right side upstairs has an emergency pan that is rusting through and will likely cause water damage. Highly advise replacement before damage occurs. Right side downstairs unit needs a return duct to be supported. This causes an air restriction and will result in equipment damage. All of the units need blower wheel cleaning to remove strain on the motors. This can lead to motor damage. I emailed all of the estimates over for review and all systems are cooling upon departure.
HVAC Comfort & Performance Evaluation Summary Customer Concern: The primary concern is the master bedroom being extremely hot, humid, and uncomfortable compared to the rest of the home. The customer explained that this room does not maintain proper comfort levels, especially during warmer parts of the day. Home Information: • Home was built in 2021 • Existing HVAC system has only had minor repairs performed • No full system performance evaluation or complete maintenance inspection has been completed on the system Findings During Initial Evaluation: 1. Poor Airflow to Master Bedroom After inspecting the supply register in the master bedroom and physically checking airflow at the vent, it was determined that airflow is extremely weak and insufficient for the size of the room. The amount of conditioned air being delivered is not strong enough to properly cool and dehumidify the master bedroom, which is a major contributor to the discomfort. This room requires stronger airflow and p
Upon arrival, I discovered the system to be empty of R22. The system is from 1990. This is a Frankenunit. The cooling and heating are completely split, but the ducts are set up to allow heating and cooling to be supplied. The cooling downstairs is shut off by a manual damper. The unit does not have zoning and has 2 thermostats. Review video to see what I mean by completely split.
Replaced suction line temperature sensor. Insured unit was cooling properly upon departure.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Starting to see m Small amount of dust in return plenum and ducts but not so much that I would say a duct cl
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Found large amount of dust and debris in the return Plenum and ducts. I advised duct cleaning to remove dust
Upon completion of my thorough evaluation I found that the outdoor coil could benefit from having a deep cleaning done on it. By having it cleaned you can help the unit run at its peak performance and efficiency. Temperature sensor was the wrong sensor will have to come back.
ECM Condenser Fan Motor Replacement Scope of Work - Remove failed ECM condenser fan motor - Install new ECM condenser fan motor - Reconnect wiring and ensure proper mounting and blade alignment - Test system to verify proper fan operation and airflow Materials & Equipment - ECM condenser fan motor - Mounting hardware and electrical connection supplies
Performed drain line clearing and tested to ensure line was fully clear. Added 2 lbs of 410A. Measured 52 degree supply. Unit in good working order upon departure.