McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between February 2026 and April 2026.
The most recent job was on April 8, 2026.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
Upon arrival client stated that there were rips in the duct work on the supply side on the upstairs unit. I inspected the unit and found that it’s where the manual damper lever is coming out of the duct and explained that it’s normal for those lever spots to have a rip. No air was going into the attic from those spots.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Downstairs unit outside condenser was looking extremely matted and dirty. This restricts airflow and heat ex
Upon completion of my thorough evaluation I found that the outdoor coil could benefit from having a deep cleaning done on it. By having it cleaned you can help the unit run at its peak performance and efficiency. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Temperature being supplied to the home was 48 degrees, with 70 return. I treated and flushed the drain lines with water and total . I tested the run amps of both the compressor and fan. I found that hey are testing within manufacturer specifications. I did find that there is an error code on the thermostat stating that the suction line temperature sensor is not functioning correctly. Unit did not need to have filter changed at this time. 20x25x4 Aprilaire 210. Unit was cooling upon departure.
I performed a single cooling maintenance on a 2015 gas system. I checked amps, capacitors, filter, electrical, drains, cleanliness, and safeties. I noticed that the blower motor was dirty and beginning to leak oil. This is an early sign of failure. I observed that the emergency drain pan is compromised and beginning to rust through. The outdoor unit is getting a build up of leaves and needs a chemical bath. The outdoor capacitor is out of range and will likely fail soon. Customer approved replacement of the capacitor during time of service. Customer would like to wait to do the blower motor next visit. I collected for the work I performed today.
I performed cooling maintenance on 3 communicating gas systems. I checked amps, filters, electrical, cleanliness, drains, and rinsed the outdoor units. All of the issues I noticed are associated with the upstairs unit. During my thorough evaluation, I noticed that the blower wheel and condenser coil is dirty. The blower wheel being dirty reduces the lifespan of the motor and lowers performance. The outdoor condenser coil being dirty causes strain to the fan motor and other electrical components. Also, it reduces the performance of the equipment. While testing the drain, I could hear it gurgling at the drain. This indicates that a clog is forming and will likely clog up soon. I noticed that the condenser fan motor was loud. During rinsing the outdoor units, I noticed that the upstairs fan motor did not slow down in response to the cool water being applied. These motors have a module on top that controls the speed of it. These modules can fail causing odd operation or complete failure.
Upon completion of my thorough evaluation I found that there is a reasonable amount of dust build up in the duct work of both systems and on the blower wheel of the main living By having these cleaned it can help improve air quality and help the major components last longer. I also found on the outside unit that the capacitor was while still testing within manufacturer specifications it was testing on the lower end of the specifications. 33/35 allowance is 32. The unit is also start higher on amps at over 100 amps. By installing a hard start kit it can help the compressor start easier and help the longevity of it. I also rinsed the outside units with water and flushed the drain lines with totalc and water. Main unit takes a 20x25x4 filter and the master unit takes a Aprilaire 410 16x20x4.
Upon arrival, the thermostat was presenting a fault on the thermostat stating that the blower was not operating. I set the blower to On and proceeded to the attic. I took an amp reading and video of the blower being fully operational before resetting the system. After reseting the system, I tested the drain to ensure it was clear and set the system to cooling. I discovered no issues that would have caused this, during the thorough evaluation of the equipment. I asked the customer about prior events before the fault code. She was unsure about which cycle was being ran and did not notice a power surge. The system is cooling without fault codes upon departure. I advised the customer to document what cycle was being ran, if the fault code comes back. Also, I informed her of our call back policy.
Replacement of a variable speed blower motor. 1.unwiring the control board to cover panel can be removed 2 removal of the blower assembly 3. Removing the blower motor from the assembly 4. Install new blower motor 5. Install the cover plate 6. Wire the system back 7. Test the system for proper operation Upon completion, the system began giving a E13 code. This indicates that the system does not recognize the replacement motor. I spoke with tech support and trane. I was told that the system cannot recognize the motor unless the personality module is replaced. During initial diagnosis, I was not informed when ordering the motor that this would be an issue. The tech support guy said that since this is an “older” furnace that I cannot program it to recognize it.
Upon completion of my thorough evaluation of the indoor unit. I found that the units blower wheel could benefit from having a deep cleaning done. A decent amount of dust has built up on the fins. By cleaning the blower wheel you can help improve the performance and efficiency of your unit. I tested all other components and all tested within manufacturer specifications. I changed the filter for the client 20x25x1. Also treated and flushed the drain lines with total c and water. Upon completion of my thorough evaluation of the outdoor unit. I found that the Contactor of the unit was testing on the higher side of the manufacture specifications range at 20ohms, we typically like to see the Contactor to be between 15 and 20ohms. I also noticed the unit could benefit from have surge protection added to the system to help prevent damage caused by lightning strikes and any other types of power surges. I rinsed the unit with water at today’s visit, all other electrical components tested wit
Upon arrival, I discovered the guest bedroom unit not blowing air. I went into the attic had found the unit giving a E17 code. This code indicates that the blower is not communicating. I tested my voltages and verified all of my voltage is there for it to operate. I called trane to locate the motor. The nearest one is Carrolton or Garland. Customer did not move forward at this time.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. 2. Visually inspected condenser coil for leaks and abnormalities. 3. Inspected condenser fan motor, blades and bearings. 4. Inspected, cleaned, and, tightened wiring connections. 5. Measured capacitance of compressor/fan motor capacitor. 6. Inspected and measured resistance of contactor 7. Measured compressor current draw. 8. Measured condenser fan motor amp draw. 9. Inspected and replaced return filter. 10. Inspected return plenum for dust or debris. 11. Inspected evaporator coil for cleanliness and oxidation. 12. Inspected blower motor/ blower wheel for dust and debris 13. Measured blower motor current draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Tested drain lines for proper drainage and treated to prevent blockages. Advised homeowner use 4 inch filters as there is a compatible filter box. 4 inch filters provides superior
Customer wants to turn the u/s unit into the suite unit and attach the u/s ducts to the d/s unit. This means we will need to convert the d/s unit to zoning. I went through and built a material list. I told the customer to give us until next week to get the pricing to him.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found control wire to both outdoor units damaged by UV rays. Exposed copper showing on both wires. This can cause electrical shorts which could damage electrical components. Advised homeowner to have the sun exposed wire replaced and sheathed. Homeowner was unhappy this was not addressed du
By installing an HVAC UV light, you can eliminate mold and mildew, kill viruses and bacteria, and reduce odors, all of which will improve the quality of your indoor air. Additionally, UV lights increase the efficiency of your HVAC. The UV lamps will clean the coils and air that passes through the HVAC system naturally. Installed u/v light, transformer, and warranty thermostat. I removed the old thermostat from Trane Home and added the new one. I tested the system to ensure everything was working properly and registered the u/v light.
I performed a single cooling maintenance on a 2023 heat pump system. I checked amps, filter, electrical, cleanliness, and safeties. Customer mentioned an issue with the thermostat losing Wi-Fi connection. We will order and replace it under parts and labor warranty. I observed that growth is forming in the blower compartment and it needs to be addressed before it progresses. Customer wants pricing on installing a mini split in his garage. The garage is 900sq ft. There is 240v that would have to be routed to an optimal location for the mini split, but it is nearby.
Upon completion of my thorough evaluation. I found that the blower wheel, condenser and evaporator coils to be dirty and dusty. This can affect the performance and efficiency of the unit. I tested all electrical components on the system all tested within manufacturer specifications. I treated the drain lines with totalc and water. Client did not have a filter for me to change at this time. Aprilaire 210. 20x25x4. I rinsed the outside unit with water. Unit was cooling upon departure.
Preformed outdoor dome sensor replacement. Unit was working properly upon departure.
Customer Visit Summary – System Replacement Consultation Met with the homeowner to evaluate both HVAC systems in the home. The upstairs system is a 3-ton unit, and the downstairs system is a 4-ton unit. Based on the age and condition of the equipment, we discussed replacement options for both systems. Presented multiple system options, including different efficiency levels and warranty packages, so the customer can review what best fits their comfort goals and budget. We also discussed the benefits of upgrading both systems at the same time for improved performance, efficiency, and long-term reliability. The customer will take the next few days to review the options and discuss them together before making a final decision. I let them know I’m available to answer any questions and assist them in selecting the best solution for their home. Next Step: Follow up with the customer in the next few days to see if they have any questions and whether they are ready to move forward with the
During today’s visit, I inspected the three HVAC systems in the home to evaluate their performance and overall condition. Below is a summary of my findings and recommended improvements to help maintain system reliability and efficiency. North AC System Equipment: 2022 Trane system The system is operating properly and the indoor equipment is in good overall condition. Noticed the system is using a 20x25x1 filter. The outside unit is over amping which can cause compressor damage over time. Solutions: Install an Aprilaire high-efficiency filtration upgrade to improve indoor air quality and provide better filtration for the home. Install a hard start kit to assist the compressor during startup. This reduces electrical strain and can help extend the life of the compressor. South AC System Equipment: 2022 Trane system Noticed the system is using a 20x25x1 filter. The outside unit is over amping which can cause compressor damage over time. Solutions: Install an Aprilaire high-efficie
Parts and labor warranty is active until 2031. Replaced evaporator coil, liquid dryer, and added 3 lbs of refrigerant. Replaced blower motor under part and labor warranty. System tested and working properly
Performed single system maintenance on a 2018 gas unit. I began by checking all the electrical components on the inside unit and for cleanliness. All electrical components tested within manufacturer specifications. I was getting a temperature split of 79 return and 44 supply. I changed the filter for the client. 20x25x4. The filter was being sucked into the blower cavity, it had lost its integrity. I also noticed the duct work to have some dust and debris build up in them. I then proceeded outside were I tested all electrical components on the outside unit. I found that the compressor start amps were over amping at 100 plus, manufacturer rating is for 134 on start up. All other electrical components were testing within manufacturer specifications. I noticed the system did not have any type of surge protection on it. I provided estimates to have all concerns addressed. I rinsed the outside unit at today’s visit. Unit was cooling upon departure.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found good amount of dust in ducts and air report showed high levels of particulate matter. Advised homeowner they could benefit from a duct cleaning to improve air quality and reduce stress on system. Homeowner is not interested in insulation at this time, but will consider duct cleaning f
Upon arrival, I discovered the outdoor unit in a low pressure lock out. I reset the outdoor unit and tested the system in cooling. It appeared that the system was low on R410a. I proceeded to introduce refrigerant to the system for testing purposes. I added approximately 1 and a half pounds. This verified that it was low due to pressures leveling out. I proceeded with a leak search and got minor alerts on my infrared leak detector in the evaporator coil. Also, I suspect that the blower may be having an issue. We will have to reach out to the manufacture on Monday to locate the coil. We will replace the blower motor, as well. Customer has parts and labor until 2031.
I performed a heating maintenance on a 2019 gas system. I checked amps, filters, electrical, drains, cleanliness, and safeties. Customer requested I inspect the drain. I flushed the drain with a water/chemical mixture to ensure it was clear and advised that putting bleach/vinegar would help with maintaining the drain. I observed that the emergency drain pan is showing signs of calcium formation on the bottom and that the system does not have a water safety switch. I provided options to the customer for these items. Customer declined during service.
Client stated her daughter’s bedroom is not getting cool enough durning the cooling season. We spoke about possibly adding a return duct to her room to help with the hot and cold spot. Preformed single system cooling maintenance on a 2023 gas system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I changed filter for client today Aprilaire 210 (20x25x4). I treated drain lines with total c. Temp across the coil was 20 degrees drop. 53 supply and 75 return. I proceeded outside where I tested all electrical components, run and start amps of the compressor. All electrical tested within manufacturer specifications. The compressor start amps were over amping at 100 plus rated for 124. Also noticed the unit was not protected against any type of surge in power. I provided estimates to have all concerns resolved. I completed thorough evaluation of system. Condenser compressor is starting high on amps. Over 100 rated for 124. Also the syste