Menu

Heating and Air Conditioning in Plano, TX

Adon Complete Air Conditioning and Heating has provided HVAC services in Plano, TX, for years, serving Collin County from our home base in Anna, just up Highway 75. Whether your AC quits on a July afternoon, your furnace needs attention before the first cold front, or you are ready to upgrade to a more efficient system, our technicians regularly work in Plano neighborhoods and know the homes here well.

Plano is one of the largest cities we serve, and its homes reflect that. We work on older single-stage systems in established East Plano neighborhoods and modern variable-speed equipment in newer Legacy corridor builds. Many larger homes in Plano run two separate HVAC systems, and we are experienced diagnosing and servicing both in the same visit. We service all makes and models; we are a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we are available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in PlanoCall (903) 482-4900

HVAC Services We Offer in Plano, TX

AC Repair: Same-day AC repair available throughout Plano and Collin County. We diagnose and repair all makes and models, and most calls are resolved in a single visit. When your air conditioning goes out in the Plano heat, we treat it like the emergency it is.

AC Installation and Replacement: When your Plano home needs a new system, we size it correctly using a load calculation and install it to manufacturer specs. All new installations come with up to a 10-year labor warranty. We’ll help you choose the right capacity and efficiency rating for your home, not just the unit that fits the budget.

Heating Repair and Installation: We service gas furnaces, heat pumps, and electric systems throughout Plano. Winters here are mild but the occasional hard freeze is real, and a furnace that won’t fire in January isn’t something you want to wait on. We stock parts for the most common brands and most repairs are done in one visit.

HVAC Maintenance: Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Plano homeowners running two systems, it’s the most practical way to keep both units maintained without scheduling separate visits.

Ductless Mini-Split Systems: Plano’s sunrooms, home offices, garage conversions, and older additions without ductwork are ideal for ductless mini-splits. We install single and multi-zone systems throughout Plano, and they’re significantly more efficient than window units or electric baseboard heat.

Heat Pumps: Heat pumps handle both heating and cooling from a single system and are a practical choice for Plano homeowners who want year-round efficiency. In a climate where extreme cold is rare but energy costs matter, a modern heat pump often outperforms a traditional gas furnace and AC combo on annual operating costs.

Indoor Air Quality: Newer construction in Plano is built tight for energy efficiency, which traps allergens, dust, and humidity inside. We offer air filtration systems, UV air purifiers, ventilators, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Plano area homeowners.

Duct Cleaning and Duct Repair: Leaky or dirty ductwork is one of the most common causes of uneven temperatures and high energy bills in Plano homes, especially two-story and multi-system properties. We inspect, clean, and seal ductwork throughout Plano and Collin County, and fixing the ducts often makes a bigger difference than replacing the equipment.

Why Plano Homeowners Choose Adon Complete for HVAC Service

Neighborhoods We Serve in Plano, TX

We provide HVAC services throughout Plano, including Legacy West, Windhaven Meadows, Willow Bend, Haggard Park, Ridgeview Ranch, Chase Oaks, and the communities along the Dallas North Tollway corridor. We also serve Plano’s neighboring cities, including Allen, McKinney, Frisco, and Anna. If you’re not sure whether we cover your area, call us, and we’ll let you know.

Schedule HVAC Service in PlanoCall (903) 482-4900

Plano, TX HVAC FAQ

How much does AC repair cost in Plano, TX?

Most AC repairs in Plano run between $150 and $600, depending on the repair type. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs, like a blower motor or evaporator coil, cost more. We give you a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Plano?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Plano and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC during a Plano summer can’t wait until morning.

My Plano home has two HVAC systems. Can you service both on the same visit?

Yes, and we do it regularly. Many larger Plano homes, particularly those along the DNT corridor and in the Legacy area, run separate systems for the upstairs and downstairs zones. Our technicians can diagnose and service both units in the same appointment, saving time and giving us a complete picture of how the home is performing.

My newer Plano home feels stuffy even though the AC is working fine. What is going on?

Tight construction is usually the culprit. Homes built in Plano’s newer developments are sealed for energy efficiency, which reduces natural air exchange and traps moisture, allergens, and CO2 inside. A whole-home ventilator or ERV brings in fresh outdoor air while recovering the energy you have already spent conditioning the air inside. It is the right fix for stuffy newer construction, and we install them throughout Plano.

What HVAC brands do you service in Plano?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands, but we do not turn down a job because of what brand is on the equipment.

Schedule HVAC Service in Plano, TX Today

Whether you need same-day AC repair, a new system installed, or want to get on a maintenance plan before the heat hits, Adon Complete Air Conditioning and Heating is ready to help. Call us at (903) 482-4900 or click below to schedule. We also serve the surrounding Collin County communities of Allen, McKinney, Wylie, and Anna.

Schedule HVAC Service in PlanoCall (903) 482-4900

Recent Jobs and Reviews in Plano, TX

Rated 4.9 out of 5 stars based on 9 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Plano, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Plano, TX between May 2025 and June 2025.

The most recent job was on June 12, 2025.

Adon Complete Air Conditioning and Heating has completed 81 jobs in Plano, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange Disconnect was loose and would not seat properly on the downstairs unit that was having issues. Any movement would flick the unit on and off. Hardstart was testing outside of manufacturer specifications. Found a bad capacitor on upstairs unit blower motor. Blower motor was caked in dust and pulling 11 amps out of 7.3. Notice
Plano, TX 75093
Brayden W.
Brayden W.
Condenser cap has failed and burned some wires. Fan cap is not far behind. Replaced fan and compressor cap with new capacitor. Upon inspection of indoor unit Noticed bad seal on return due to improper hanging of plenum. Seal around copper/ liquid line coming into Evap coil is gone. Letting cold air into attic. Drain pan is almost rusted out. 20 degree temperature split measured. Unit in good working order upon departure. Left estimates for recommended repairs. Informed dispatch to schedule maintenance within next couple weeks. Sent estimates to customer so that we may be able to get both done at once.
Plano, TX 75093
Jacob P.
Jacob P.
Labor covered
Plano, TX 75023
Brayden W.
Brayden W.
Replaced 5T hardstart kit that had failed.
Plano, TX 75074
Cesar O.
Cesar O.
Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,there’s a hard start kit install (521) but it failed,, recommended to replace it,,,she will ask the husband to replace it himself . 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty,,homeowner is aware that it it dusty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. 17. Tested contactor. Unit is cooling properly at this time.
Plano, TX 75074
Cesar O.
Cesar O.
Customer stated that the unit wasn’t cooling,, that there was water leaking inside the store next to a return vent. We noticed return filters are extremely dirty, (3), proceeded to inspect the outdoor unit ( package)up on the roof, found the blower running but not the compressor or condenser fan motor,,, checked call for cooling,didn’t have any, found thermostat set to heat and blower on,,, set thermostat to cool, unit started right away, we checked blower/ compressor/ condenser fan motor amp draw, tested OK, checked refrigerant pressures, tested ok as well,,,main drain pan was dried, main drain line was cleared. We measured temperature differential, had 20 degrees split differential, we didn’t notice any damage up on the roof around the unit that might have caused the water leak, we highly believe that the unit might’ve froze up due to extremely dirty filters and wasn’t breathing properly. We also noticed both 3 pole contactor are buzzing which it’s not normal, we recommend to replace
Plano, TX 75074
Cesar O.
Cesar O.
Homeowner stated that the downstairs unit is not cooling,,that we were here several times and the unit still not working properly. We found the unit tripped on L7 code ,, ( high pressure), noticed the unit was extremely dirty, we washed it today, started unit up again, code disappeared, 06 came up, ( open circuit), called technical support,, was told to check on the run capacitor,, capacitor is rated 35/5 mfd ,, was reading 5/4.9 mfd,, replaced it today,, tested the system again, unit came on normally, measured temperature differential, had 21 degrees split differential, found no more issues/ concerns at this time, homeowner is aware that the upstairs unit also needs to be washed (condenser), we just washed them on previous visit but they need to be clean again,.
Plano, TX 75074
Jacob P.
Jacob P.
We arrived at our clients home for a 2 system cooling maintenance inspection. Our client did not have filters for us to replace today. We began outside by testing both condenser units. All of the electrical components tested within range today. The downstairs unit Freon pressures were a little low. When we proceeded inside to inspect the attic equipment we found that the blower motors are had been leaking oil and subsequently causing the Freon pressure to be low because the air is not being pushed across the coils adequately. The upstairs unit Freon pressures are also low. This unit is much older and uses the old R22 Freon in it. When inspecting the indoor equipment we did also inspect the indoor coil for the upstairs equipment and there is evidence that there is a small leak present in the system. We presented all of our findings to our client and he elected to replace the indoor blower motor for the downstairs system today. This will allow the system to operate for a little bit l
Plano, TX 75024
Cesar O.
Cesar O.
Replaced a condenser fan motor/ condenser fan blades , tested OK We also performed the maintenance today.. Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,contactor is reading 11 ohms , not meeting manufacturer specifications,, recommend to replace it . 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. Found no more issues/ concerns at this time, unit is cooling properly.
Plano, TX 75075
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange 16. Checked pressures to ensure proper charge Float switch was incorrectly wired. Fixed issue and tested to ensure proper function. Unit in good working order upon departure.
Plano, TX 75025

Your High Efficiency

Experts