Menu

Heating and Air Conditioning in Plano, TX

Adon Complete Air Conditioning and Heating has provided HVAC services in Plano, TX, for years, serving Collin County from our home base in Anna, just up Highway 75. Whether your AC quits on a July afternoon, your furnace needs attention before the first cold front, or you are ready to upgrade to a more efficient system, our technicians regularly work in Plano neighborhoods and know the homes here well.

Plano is one of the largest cities we serve, and its homes reflect that. We work on older single-stage systems in established East Plano neighborhoods and modern variable-speed equipment in newer Legacy corridor builds. Many larger homes in Plano run two separate HVAC systems, and we are experienced diagnosing and servicing both in the same visit. We service all makes and models; we are a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we are available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in PlanoCall (903) 482-4900

HVAC Services We Offer in Plano, TX

AC Repair: Same-day AC repair available throughout Plano and Collin County. We diagnose and repair all makes and models, and most calls are resolved in a single visit. When your air conditioning goes out in the Plano heat, we treat it like the emergency it is.

AC Installation and Replacement: When your Plano home needs a new system, we size it correctly using a load calculation and install it to manufacturer specs. All new installations come with up to a 10-year labor warranty. We’ll help you choose the right capacity and efficiency rating for your home, not just the unit that fits the budget.

Heating Repair and Installation: We service gas furnaces, heat pumps, and electric systems throughout Plano. Winters here are mild but the occasional hard freeze is real, and a furnace that won’t fire in January isn’t something you want to wait on. We stock parts for the most common brands and most repairs are done in one visit.

HVAC Maintenance: Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Plano homeowners running two systems, it’s the most practical way to keep both units maintained without scheduling separate visits.

Ductless Mini-Split Systems: Plano’s sunrooms, home offices, garage conversions, and older additions without ductwork are ideal for ductless mini-splits. We install single and multi-zone systems throughout Plano, and they’re significantly more efficient than window units or electric baseboard heat.

Heat Pumps: Heat pumps handle both heating and cooling from a single system and are a practical choice for Plano homeowners who want year-round efficiency. In a climate where extreme cold is rare but energy costs matter, a modern heat pump often outperforms a traditional gas furnace and AC combo on annual operating costs.

Indoor Air Quality: Newer construction in Plano is built tight for energy efficiency, which traps allergens, dust, and humidity inside. We offer air filtration systems, UV air purifiers, ventilators, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Plano area homeowners.

Duct Cleaning and Duct Repair: Leaky or dirty ductwork is one of the most common causes of uneven temperatures and high energy bills in Plano homes, especially two-story and multi-system properties. We inspect, clean, and seal ductwork throughout Plano and Collin County, and fixing the ducts often makes a bigger difference than replacing the equipment.

Why Plano Homeowners Choose Adon Complete for HVAC Service

Neighborhoods We Serve in Plano, TX

We provide HVAC services throughout Plano, including Legacy West, Windhaven Meadows, Willow Bend, Haggard Park, Ridgeview Ranch, Chase Oaks, and the communities along the Dallas North Tollway corridor. We also serve Plano’s neighboring cities, including Allen, McKinney, Frisco, and Anna. If you’re not sure whether we cover your area, call us, and we’ll let you know.

Schedule HVAC Service in PlanoCall (903) 482-4900

Plano, TX HVAC FAQ

How much does AC repair cost in Plano, TX?

Most AC repairs in Plano run between $150 and $600, depending on the repair type. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs, like a blower motor or evaporator coil, cost more. We give you a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Plano?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Plano and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC during a Plano summer can’t wait until morning.

My Plano home has two HVAC systems. Can you service both on the same visit?

Yes, and we do it regularly. Many larger Plano homes, particularly those along the DNT corridor and in the Legacy area, run separate systems for the upstairs and downstairs zones. Our technicians can diagnose and service both units in the same appointment, saving time and giving us a complete picture of how the home is performing.

My newer Plano home feels stuffy even though the AC is working fine. What is going on?

Tight construction is usually the culprit. Homes built in Plano’s newer developments are sealed for energy efficiency, which reduces natural air exchange and traps moisture, allergens, and CO2 inside. A whole-home ventilator or ERV brings in fresh outdoor air while recovering the energy you have already spent conditioning the air inside. It is the right fix for stuffy newer construction, and we install them throughout Plano.

What HVAC brands do you service in Plano?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands, but we do not turn down a job because of what brand is on the equipment.

Schedule HVAC Service in Plano, TX Today

Whether you need same-day AC repair, a new system installed, or want to get on a maintenance plan before the heat hits, Adon Complete Air Conditioning and Heating is ready to help. Call us at (903) 482-4900 or click below to schedule. We also serve the surrounding Collin County communities of Allen, McKinney, Wylie, and Anna.

Schedule HVAC Service in PlanoCall (903) 482-4900

Recent Jobs and Reviews in Plano, TX

Rated 4.9 out of 5 stars based on 9 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Plano, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Plano, TX between November 2025 and February 2026.

The most recent job was on February 3, 2026.

Adon Complete Air Conditioning and Heating has completed 81 jobs in Plano, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Matthew C.
Matthew C.
Preformed single system heating maintenance on a 2018 gas system. I tested all electrical components and safeties. All tested within manufacturer specifications. Temperature being supplied to the home was 118 and 73 return air. Filter had recently been changed, 20x25x4. Provided estimate to have Aprilaire conversion kit installed to upgrade their filtration system. I proceeded outside where I visually inspected the outside unit. All was in good working order. Unit was heating upon departure.
Plano, TX 75023
Plano, TX - Preformed single system heating maintenance on a 2018 gas system. I tested all electrical components and safeties. All tested within manufacturer specifications. Temperature being supplied to the home was 118 and 73 return air. Filter had recently been changed, 20x25x4. Provided estimate to have Aprilaire conversion kit installed to upgrade their filtration system. I proceeded outside where I visually inspected the outside unit. All was in good working order.  Unit was heating upon departure.
Plano, TX - Preformed single system heating maintenance on a 2018 gas system. I tested all electrical components and safeties. All tested within manufacturer specifications. Temperature being supplied to the home was 118 and 73 return air. Filter had recently been changed, 20x25x4. Provided estimate to have Aprilaire conversion kit installed to upgrade their filtration system. I proceeded outside where I visually inspected the outside unit. All was in good working order.  Unit was heating upon departure.
Shelby S.
Shelby S.
I performed a 2 system heating maintenance on 2014 and 2005 gas systems. I checked amps, capacitors, filters, cleanliness, electrical, and safeties. I observed burning present on the upstairs control board, the capacitor for the upstairs is failing, the downstairs has poor filtration, and the systems do not have surge protection. I provided solutions to address these concerns. Customer approved replacing the capacitor for the upstairs and the work was performed at the time of service.
Plano, TX 75024
Plano, TX - I performed a 2 system heating maintenance on 2014 and 2005 gas systems. I checked amps, capacitors, filters, cleanliness, electrical, and safeties. I observed burning present on the upstairs control board, the capacitor for the upstairs is failing, the downstairs has poor filtration, and the systems do not have surge protection. I provided solutions to address these concerns. Customer approved replacing the capacitor for the upstairs and the work was performed at the time of service.
Plano, TX - I performed a 2 system heating maintenance on 2014 and 2005 gas systems. I checked amps, capacitors, filters, cleanliness, electrical, and safeties. I observed burning present on the upstairs control board, the capacitor for the upstairs is failing, the downstairs has poor filtration, and the systems do not have surge protection. I provided solutions to address these concerns. Customer approved replacing the capacitor for the upstairs and the work was performed at the time of service.
Matthew C.
Matthew C.
Performed a complete heating 2 system maintenance and inspection. 2016 Gas systems. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 113°F and rising. Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”. I visually inspected the outdoor unit, The outdoor unit was in good condition . Provided estimates for surge protection. Client would like to visit in the spring. Client would like estimate to add a humidifier into the downstairs system. Confirmed system was operating properly and heating upon departure.
Plano, TX 75025
Plano, TX - Performed a complete heating 2 system maintenance and inspection. 2016 Gas systems. 

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 113°F and rising.

Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition . Provided estimates for surge protection. Client would like to visit in the spring. 

Client would like estimate to add a humidifier into the downstairs system.

Confirmed system was operating properly and heating upon departure.
Plano, TX - Performed a complete heating 2 system maintenance and inspection. 2016 Gas systems. 

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 113°F and rising.

Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition . Provided estimates for surge protection. Client would like to visit in the spring. 

Client would like estimate to add a humidifier into the downstairs system.

Confirmed system was operating properly and heating upon departure.
Matthew C.
Matthew C.
Preformed Duct cleaning estimate. Client elected to have a full system cleaning done.
Plano, TX 75023
Plano, TX - Preformed Duct cleaning estimate. Client elected to have a full system cleaning done.
Plano, TX - Preformed Duct cleaning estimate. Client elected to have a full system cleaning done.
Matthew C.
Matthew C.
Performed a complete heating system maintenance and inspection. 2024 Gas system. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Spoke to client about duct cleaning. Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 116°F and rising. Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”. Aprilaire 210 client said he would change. I visually inspected the outdoor unit, The outdoor unit was in good condition Talked client about surge protection. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.
Plano, TX 75025
Plano, TX - Performed a complete heating system maintenance and inspection. 2024 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Spoke to client about duct cleaning.


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 116°F and rising. 

Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”. Aprilaire 210 client said he would change.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition 
Talked client about surge protection.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Plano, TX - Performed a complete heating system maintenance and inspection. 2024 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Spoke to client about duct cleaning.


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 116°F and rising. 

Confirmed air filter was recently replaced by client; filter size is 20” x 25” x 4”. Aprilaire 210 client said he would change.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition 
Talked client about surge protection.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Shelby S.
Shelby S.
I installed a new gas valve. Old valve has an all thread that I could not remove. This resulting in a redesign to install it properly. I tested and set the gas pressure of the unit. It is heating upon departure.
Plano, TX 75074
Plano, TX - I installed a new gas valve. Old valve has an all thread that I could not remove. This resulting in a redesign to install it properly. I tested and set the gas pressure of the unit. It is heating upon departure.
Plano, TX - I installed a new gas valve. Old valve has an all thread that I could not remove. This resulting in a redesign to install it properly. I tested and set the gas pressure of the unit. It is heating upon departure.
Matthew C.
Matthew C.
Performed a complete heating system maintenance and inspection. 2023 Gas system. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. I noticed that the ducts and plenum boxes were dirty with dust. Could benefit from a duct cleaning. Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 114°F and rising. Changed filter for client; filter size is 20” x 25” x 4”. I visually inspected the outdoor unit, The outdoor unit was in good condition Only noticed that the outdoor unit has no surge protection on it. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service
Plano, TX 75075
Plano, TX - Performed a complete heating system maintenance and inspection. 2023 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

I noticed that the ducts and plenum boxes were dirty with dust. Could benefit from a duct cleaning. 


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 114°F and rising.

Changed filter for client; filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition 

Only noticed that the outdoor unit has no surge protection on it. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service
Plano, TX - Performed a complete heating system maintenance and inspection. 2023 Gas system.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

I noticed that the ducts and plenum boxes were dirty with dust. Could benefit from a duct cleaning. 


Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 114°F and rising.

Changed filter for client; filter size is 20” x 25” x 4”.

I visually inspected the outdoor unit, 
The outdoor unit was in good condition 

Only noticed that the outdoor unit has no surge protection on it. 

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Found dirty blower wheel. Homeowner is not interested in having it cleaned to prolong the life of the system. Unit in good working order upon departure.
Plano, TX 75025
Plano, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
Found dirty blower wheel. Homeowner is not interested in having it cleaned to prolong the life of the system. Unit in good working order upon departure.
Plano, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
Found dirty blower wheel. Homeowner is not interested in having it cleaned to prolong the life of the system. Unit in good working order upon departure.
Matthew C.
Matthew C.
I preformed dryer vent cleaning, before I started I noticed the vent pipe for the dryer vent was detached from the roof where it exits and sending lint into the attic. Client stated they would fix the issue themselves. Preformed maintenance on a 2016 single gas. I tested all electrical components and safeties. All tested within manufacturer specifications. I did notice that the ducts had a sufficient amount of build up in them.client did not have filters at the time of inspection 20x25x4. I provided estimates to have the ducts cleaned. Unit was cooling upon departure.
Plano, TX 75074
Plano, TX - I preformed dryer vent cleaning, before I started I noticed the vent pipe for the dryer vent was detached from the roof where it exits and sending lint into the attic. Client stated they would fix the issue themselves. 

Preformed maintenance on a 2016 single gas. I tested all electrical components and safeties. All tested within manufacturer specifications. I did notice that the ducts had a sufficient amount of build up in them.client did not have filters at the time of inspection 20x25x4. I provided estimates to have the ducts cleaned. Unit was cooling upon departure.
Plano, TX - I preformed dryer vent cleaning, before I started I noticed the vent pipe for the dryer vent was detached from the roof where it exits and sending lint into the attic. Client stated they would fix the issue themselves. 

Preformed maintenance on a 2016 single gas. I tested all electrical components and safeties. All tested within manufacturer specifications. I did notice that the ducts had a sufficient amount of build up in them.client did not have filters at the time of inspection 20x25x4. I provided estimates to have the ducts cleaned. Unit was cooling upon departure.
Brayden W.
Brayden W.
Arrived on site, for heating maintenance on Trane 2020 condenser and 2016 Lennox furnace. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Complementary air report show high levels of particulate matter. Discussed benefits of air scrubber air purification with homeowner. Homeowner asked for an estimate to his email to look over. Also noticed there was no surge protection on either unit. Recommended surge protection to protect electrical components.
Plano, TX 75075
Plano, TX - Arrived on site, for heating maintenance on Trane 2020 condenser and 2016 Lennox furnace.
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
Complementary air report  show high levels of particulate matter. Discussed benefits of air scrubber air purification with homeowner. Homeowner asked for an estimate to his email to look over. Also noticed there was no surge protection on either unit. Recommended surge protection to protect electrical components.
Plano, TX - Arrived on site, for heating maintenance on Trane 2020 condenser and 2016 Lennox furnace.
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
Complementary air report  show high levels of particulate matter. Discussed benefits of air scrubber air purification with homeowner. Homeowner asked for an estimate to his email to look over. Also noticed there was no surge protection on either unit. Recommended surge protection to protect electrical components.

Your High Efficiency

Experts