Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in February 2026.

The most recent job was on February 25, 2026.

Adon Complete Air Conditioning and Heating has completed 588 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
Upon arrival, I discovered an operational unit. I asked Carrie some question to help me better understand what happened. I tested the system in heating and cooling ensuring that the reversing valve is swapping between heating and cooling. I called and spoke with Jesse about a concern I had with the design. The area is rather big with 2 walk in freezers. It is a metal section of the building. It has only a 4 ton system with approximately 4 to 5 people in the area at most times. I believe the unit is doing all it can to keep up. With Jesse’s recommendation, I sped up the blowing speeds for the cycles to increase the volume of air production. With the concerns of a potentially intermittent faulty thermostat, I would like to provide on option for replacement.
Anna, TX 75409
Anna, TX - Upon arrival, I discovered an operational unit. I asked Carrie some question to help me better understand what happened. I tested the system in heating and cooling ensuring that the reversing valve is swapping between heating and cooling. I called and spoke with Jesse about a concern I had with the design. The area is rather big with 2 walk in freezers. It is a metal section of the building. It has only a 4 ton system with approximately 4 to 5 people in the area at most times. I believe the unit is doing all it can to keep up. With Jesse’s recommendation, I sped up the blowing speeds for the cycles to increase the volume of air production. With the concerns of a potentially intermittent faulty thermostat, I would like to provide on option for replacement.
Anna, TX - Upon arrival, I discovered an operational unit. I asked Carrie some question to help me better understand what happened. I tested the system in heating and cooling ensuring that the reversing valve is swapping between heating and cooling. I called and spoke with Jesse about a concern I had with the design. The area is rather big with 2 walk in freezers. It is a metal section of the building. It has only a 4 ton system with approximately 4 to 5 people in the area at most times. I believe the unit is doing all it can to keep up. With Jesse’s recommendation, I sped up the blowing speeds for the cycles to increase the volume of air production. With the concerns of a potentially intermittent faulty thermostat, I would like to provide on option for replacement.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2022 gas system. I checked amps, filter, electrical, cleanliness, and safeties. I spoke with the customer about the importance of safeties. The customer informed me of power blimps that the home has. I advise surge protection be installed on the unit to minimize damage when these power blimps occur. I observed that the drains do not have the best water protection. I provided an option to install a primary water safety switch and blow out valve. These items will reduce the risk of surprise damages and repair cost. Customer asked that I email the options to the two of them fan review later.
Anna, TX 75409
Anna, TX - I performed a single heating maintenance on a 2022 gas system. I checked amps, filter, electrical, cleanliness, and safeties. I spoke with the customer about the importance of safeties. The customer informed me of power blimps that the home has. I advise surge protection be installed on the unit to minimize damage when these power blimps occur. I observed that the drains do not have the best water protection. I provided an option to install a primary water safety switch and blow out valve. These items will reduce the risk of surprise damages and repair cost. Customer asked that I email the options to the two of them fan review later.
Anna, TX - I performed a single heating maintenance on a 2022 gas system. I checked amps, filter, electrical, cleanliness, and safeties. I spoke with the customer about the importance of safeties. The customer informed me of power blimps that the home has. I advise surge protection be installed on the unit to minimize damage when these power blimps occur. I observed that the drains do not have the best water protection. I provided an option to install a primary water safety switch and blow out valve. These items will reduce the risk of surprise damages and repair cost. Customer asked that I email the options to the two of them fan review later.
Matthew C.
Matthew C.
Preformed single system on a 2022 straight cool Trane unit. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain lines with total c. I checked unit for cleanliness, overall the inside unit was cleaning. The unit does have a uv light installed and in good working order. I changed he filter for the client to today, 20x25x4 Aprilaire 213. I then proceeded to the outside unit where I tested all the electrical components on the outside unit. I found that all electrical components are within manufacturer specifications. I did find that the compressor was starting high on the amps. I also checked for cleanliness of the coils. I found that the coils were extremely caked in dirt and dust, this can cause the unit not to run efficiently. I provided estimates to have all concerns addressed. Unit was cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed single system on a 2022 straight cool Trane unit. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain lines with total c. I checked unit for cleanliness, overall the inside unit was cleaning. The unit does have a uv light installed and in good working order. I changed he filter for the client to today, 20x25x4 Aprilaire 213. I then proceeded to the outside unit where I tested all the electrical components on the outside unit. I found that all electrical components are within manufacturer specifications. I did find that the compressor was starting high on the amps. I also checked for cleanliness of the coils. I found that the coils were extremely caked in dirt and dust, this can cause the unit not to run efficiently. I provided estimates to have all concerns addressed. Unit was cooling upon departure.
Anna, TX - Preformed single system on a 2022 straight cool Trane unit. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain lines with total c. I checked unit for cleanliness, overall the inside unit was cleaning. The unit does have a uv light installed and in good working order. I changed he filter for the client to today, 20x25x4 Aprilaire 213. I then proceeded to the outside unit where I tested all the electrical components on the outside unit. I found that all electrical components are within manufacturer specifications. I did find that the compressor was starting high on the amps. I also checked for cleanliness of the coils. I found that the coils were extremely caked in dirt and dust, this can cause the unit not to run efficiently. I provided estimates to have all concerns addressed. Unit was cooling upon departure.
Shelby S.
Shelby S.
I performs a cooling maintenance on a heat pump system. The indoor is from 2024 and the outdoor is from 2018. During my thorough evaluation, I discovered a few deficiencies with the outdoor unit. The condenser fan motor is amping extremely close to its maximum rated amperage. This is a sign that the motor is close to the end of its life. The low voltage wires are compromised and may begin shorting out the system unless preventative measures are taken. This involves installing a protective conduit to keep the wires safe from weather and u/v rays. The disconnect is beginning to oxidize at its contacts. This will lead to the terminals getting hot and potentially burning the wires and disconnect.
Anna, TX 75409
Anna, TX - I performs a cooling maintenance on a heat pump system. The indoor is from 2024 and the outdoor is from 2018. During my thorough evaluation, I discovered a few deficiencies with the outdoor unit. The condenser fan motor is amping extremely close to its maximum rated amperage. This is a sign that the motor is close to the end of its life. The low voltage wires are compromised and may begin shorting out the system unless preventative measures are taken. This involves installing a protective conduit to keep the wires safe from weather and u/v rays. The disconnect is beginning to oxidize at its contacts. This will lead to the terminals getting hot and potentially burning the wires and disconnect.
Anna, TX - I performs a cooling maintenance on a heat pump system. The indoor is from 2024 and the outdoor is from 2018. During my thorough evaluation, I discovered a few deficiencies with the outdoor unit. The condenser fan motor is amping extremely close to its maximum rated amperage. This is a sign that the motor is close to the end of its life. The low voltage wires are compromised and may begin shorting out the system unless preventative measures are taken. This involves installing a protective conduit to keep the wires safe from weather and u/v rays. The disconnect is beginning to oxidize at its contacts. This will lead to the terminals getting hot and potentially burning the wires and disconnect.
Brayden W.
Brayden W.
Installed the following -Contactor -Turbo Multi Use Capacitor - 5-2-1 Hard Start Kit On downstairs unit and one additional turbo 200 on the upstairs unit. Both units tested and verified lower start amps on downstairs. Units in good working order upon departure.
Anna, TX 75409
Anna, TX - Installed the following
-Contactor
-Turbo Multi Use Capacitor
- 5-2-1 Hard Start Kit
On downstairs unit  and one additional turbo 200 on the upstairs unit. 

Both units tested and verified lower start amps on downstairs. Units in good working order upon departure.
Anna, TX - Installed the following
-Contactor
-Turbo Multi Use Capacitor
- 5-2-1 Hard Start Kit
On downstairs unit  and one additional turbo 200 on the upstairs unit. 

Both units tested and verified lower start amps on downstairs. Units in good working order upon departure.
Matthew C.
Matthew C.
Preformed single system heating maintenance on a 2017 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I checked for cleanliness of the system. I found the ducts to be extremely covered in dust, along with the blower wheel and the inside coil. I changed the filter for the client today 20x25x4. I proceeded outside to check the electrical components on the outside unit. All tested within manufacturer specifications. I did notice the coil to be covered in dust as well. I provided estimates to have everything addressed and cleaned. Unit was heating upon departure.
Anna, TX 75409
Anna, TX - Preformed single system heating maintenance on a 2017 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I checked for cleanliness of the system. I found the ducts to be extremely covered in dust, along with the blower wheel and the inside coil. I changed the filter for the client today 20x25x4. I proceeded outside to check the electrical components on the outside unit. All tested within manufacturer specifications. I did notice the coil to be covered in dust as well. I provided estimates to have everything addressed and cleaned. Unit was heating upon departure.
Anna, TX - Preformed single system heating maintenance on a 2017 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I checked for cleanliness of the system. I found the ducts to be extremely covered in dust, along with the blower wheel and the inside coil. I changed the filter for the client today 20x25x4. I proceeded outside to check the electrical components on the outside unit. All tested within manufacturer specifications. I did notice the coil to be covered in dust as well. I provided estimates to have everything addressed and cleaned. Unit was heating upon departure.
Matthew C.
Matthew C.
Came out for duct cleaning estimate. Found the system could benefit from having a full system cleaning done. Client elected to have evaporator coil cleaned today. Cleaned coil and presented before and after photos.
Anna, TX 75409
Anna, TX - Came out for duct cleaning estimate. Found the system could benefit from having a full system cleaning done. Client elected to have evaporator coil cleaned today. Cleaned coil and presented before and after photos.
Anna, TX - Came out for duct cleaning estimate. Found the system could benefit from having a full system cleaning done. Client elected to have evaporator coil cleaned today. Cleaned coil and presented before and after photos.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange Customer stated he noticed mini split was not keeping up in office in the mornings specifically. His thermometer was reading around 75 when set point is always 70. Advised homeowner that it was likely that the thermostat inside the mini split was being teased and I reversed the flow of the fan he always has running in the r
Anna, TX 75409
Anna, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange


Customer stated he noticed mini split was not keeping up in office in the mornings specifically. His thermometer was reading around 75 when set point is always 70. Advised homeowner that it was likely that the thermostat inside the mini split was being teased and I reversed the flow of the fan he always has running in the r
Anna, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange


Customer stated he noticed mini split was not keeping up in office in the mornings specifically. His thermometer was reading around 75 when set point is always 70. Advised homeowner that it was likely that the thermostat inside the mini split was being teased and I reversed the flow of the fan he always has running in the r
Shelby S.
Shelby S.
I performed a single system cooling maintenance on a 2012 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and safeties. During my thorough evaluation, I discovered that the emergency drain pan is compromised in multiple ways. There are screws in the low points of the pan causes a leak point. Also, the pan has rust on the bottom side meaning that it is at risk of leaking. The outdoor capacitor is right at the cusp of being out of specified range. This can lead to added stress on all of the electrical outside. The indoor unit is full of growth. It is advised that this growth be removed/treated for the health of the system and occupants. Customer declined at the time of service.
Anna, TX 75409
Anna, TX - I performed a single system cooling maintenance on a 2012 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and safeties. During my thorough evaluation, I discovered that the emergency drain pan is compromised in multiple ways. There are screws in the low points of the pan causes a leak point. Also, the pan has rust on the bottom side meaning that it is at risk of leaking. The outdoor capacitor is right at the cusp of being out of specified range. This can lead to added stress on all of the electrical outside. The indoor unit is full of growth. It is advised that this growth be removed/treated for the health of the system and occupants. Customer declined at the time of service.
Anna, TX - I performed a single system cooling maintenance on a 2012 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, drains, and safeties. During my thorough evaluation, I discovered that the emergency drain pan is compromised in multiple ways. There are screws in the low points of the pan causes a leak point. Also, the pan has rust on the bottom side meaning that it is at risk of leaking. The outdoor capacitor is right at the cusp of being out of specified range. This can lead to added stress on all of the electrical outside. The indoor unit is full of growth. It is advised that this growth be removed/treated for the health of the system and occupants. Customer declined at the time of service.
Matthew C.
Matthew C.
Preformed 2 system heating maintenance on a 2020 heat pump and 2022 heat pump. I tested all electrical components on the inside units. All tested within manufacturer specifications. I changed both filters, 20x20x1 and 20x25x1. I checked for cleanliness and both systems don’t have any build up on the blower wheels or evaporator coils. I proceeded outside to test all electrical components, start and run amps of the compressor. All tested within manufacturer specifications. I did notice both units did not have any type of surge protection installed on them. I left estimates for the surge protection to be installed. Both units were cooling upon departure
Anna, TX 75409
Anna, TX - Preformed 2 system heating maintenance on a 2020 heat pump and 2022 heat pump. I tested all electrical components on the inside units. All tested within manufacturer specifications. I changed both filters, 20x20x1 and 20x25x1. I checked for cleanliness and both systems don’t have any build up on the blower wheels or evaporator coils. I proceeded outside to test all electrical components, start and run amps of the compressor. All tested within manufacturer specifications. I did notice both units did not have any type of surge protection installed on them. I left estimates for the surge protection to be installed. Both units were cooling upon departure
Anna, TX - Preformed 2 system heating maintenance on a 2020 heat pump and 2022 heat pump. I tested all electrical components on the inside units. All tested within manufacturer specifications. I changed both filters, 20x20x1 and 20x25x1. I checked for cleanliness and both systems don’t have any build up on the blower wheels or evaporator coils. I proceeded outside to test all electrical components, start and run amps of the compressor. All tested within manufacturer specifications. I did notice both units did not have any type of surge protection installed on them. I left estimates for the surge protection to be installed. Both units were cooling upon departure

Your High Efficiency

Experts