Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX between January 2026 and February 2026.

The most recent job was on February 9, 2026.

Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
I performed a single heating maintenance on a 2017 gas system. I checked the amps, filter, electrical, cleanliness, and safeties. I discovered that the blower is becoming dirty, the filter isn’t a true fit, and that surge protection would be a great idea for the furnace. I spoke with the homeowner about these areas of concerns. I presented solutions to prevent issues with and protect the system.
Anna, TX 75409
Anna, TX - I performed a single heating maintenance on a 2017 gas system. I checked the amps, filter, electrical, cleanliness, and safeties. I discovered that the blower is becoming dirty, the filter isn’t a true fit, and that surge protection would be a great idea for the furnace. I spoke with the homeowner about these areas of concerns. I presented solutions to prevent issues with and protect the system.
Anna, TX - I performed a single heating maintenance on a 2017 gas system. I checked the amps, filter, electrical, cleanliness, and safeties. I discovered that the blower is becoming dirty, the filter isn’t a true fit, and that surge protection would be a great idea for the furnace. I spoke with the homeowner about these areas of concerns. I presented solutions to prevent issues with and protect the system.
Brayden W.
Brayden W.
Arrived on site for hard start kit installation. On initial testing found unit starting over 100amps. Installed hard start kit without issue and proceeded to test unit. Post installation unit was starting with 16amp, which is a night and day difference from what we were seeing before. This will reduce wear and stress on compressor and related electrical components. Homeowner also mentioned that master bedroom was not receiving enough air flow. Upon inspection I found the damper to that ducts had become almost shut. Removed damper as this is the longest run of duct and should need the most airflow. Added $80 charge to total for duct adjustments and resealing. Unit in good working order upon departure.
Anna, TX 75409
Anna, TX - Arrived on site for hard start kit installation. On initial testing found unit starting over 100amps. Installed hard start kit without issue and proceeded to test unit. Post installation unit was starting with 16amp, which is a night and day difference from what we were seeing before. This will reduce wear and stress on compressor and related electrical components. Homeowner also mentioned that master bedroom was not receiving enough air flow. Upon inspection I found the damper to that ducts had become almost shut. Removed damper as this is the longest run of duct and should need the most airflow. Added $80 charge to total for duct adjustments and resealing. Unit in good working order upon departure.
Anna, TX - Arrived on site for hard start kit installation. On initial testing found unit starting over 100amps. Installed hard start kit without issue and proceeded to test unit. Post installation unit was starting with 16amp, which is a night and day difference from what we were seeing before. This will reduce wear and stress on compressor and related electrical components. Homeowner also mentioned that master bedroom was not receiving enough air flow. Upon inspection I found the damper to that ducts had become almost shut. Removed damper as this is the longest run of duct and should need the most airflow. Added $80 charge to total for duct adjustments and resealing. Unit in good working order upon departure.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2018 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I observed that the indoor unit is beginning to get filthy. It has build up on the blower wheel, evaporator coil, and growth formations. I noticed that there is burning present on the bottom side of the contactor. I spoke with the homeowner about the wiring mess in the outdoor unit and presented a solution to address it. We talked about how the system is missing a water safety switch, also. I presented solutions to address these concerns with the system and I built a customer option for the customer requested items. Customer would like to move forward on 3/16/2026 anytime after 8am. We will reach out to collect a deposit closer to the date.
Anna, TX 75409
Anna, TX - I performed a single heating maintenance on a 2018 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I observed that the indoor unit is beginning to get filthy. It has build up on the blower wheel, evaporator coil, and growth formations. I noticed that there is burning present on the bottom side of the contactor. I spoke with the homeowner about the wiring mess in the outdoor unit and presented a solution to address it. We talked about how the system is missing a water safety switch, also. I presented solutions to address these concerns with the system and I built a customer option for the customer requested items. Customer would like to move forward on 3/16/2026 anytime after 8am. We will reach out to collect a deposit closer to the date.
Anna, TX - I performed a single heating maintenance on a 2018 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I observed that the indoor unit is beginning to get filthy. It has build up on the blower wheel, evaporator coil, and growth formations. I noticed that there is burning present on the bottom side of the contactor. I spoke with the homeowner about the wiring mess in the outdoor unit and presented a solution to address it. We talked about how the system is missing a water safety switch, also. I presented solutions to address these concerns with the system and I built a customer option for the customer requested items. Customer would like to move forward on 3/16/2026 anytime after 8am. We will reach out to collect a deposit closer to the date.
Shelby S.
Shelby S.
I returned to assess the wiring again. I determined that the wire needed to be ran outside and that there was another short in the system. After checking voltage, I determined the system actually had a total of 3 shorts. The thermostat wire going outside, the thermostat wire to the thermostat, and the thermostat itself. I put in a new thermostat and it dropped the voltage on O enough to make it not energize the reversing valve. This means that 2 of the 3 shorts are addressed. We will wait to address the wire run to the thermostat until it causes an issue. With the old thermostat, I was getting 24v on O with the thermostat set to off. With the new thermostat, I am getting 10v. This is not enough to slide the reversing valve, but indicates that a short is still present. I cycled heating and cooling to ensure the reversing valve was going to function correctly. The system is functioning properly upon departure.
Anna, TX 75409
Shelby S.
Shelby S.
Upon arrival, I discovered that in a call for heating the outdoor unit would begin cooling. I checked my O wire outside, and I found voltage on it when there shouldn’t be. This indicated that there is a short in the wiring. I checked all of the spare wires to common with all of the wires unhooked from the defrost board. They all had voltage on them with them not being used at the airhandler. This narrowed my search to the wire going to the outdoor unit. I could not locate an obvious short, and I even checked the conduit outside that had water in it. I completely removed the conduit and checked again. I still found that all of the spare wires are shorted. I wired the defrost board back up and it failed. I unhooked O to allow it to heat, and I jumped power from Y to the contactor because it quit passing power. I cycled the unit to ensure it would shut off when satisfied. System is temporarily heating with defrost board bypassed and O unhooked. Customer approved rework for warranty defros
Anna, TX 75409
Anna, TX - Upon arrival, I discovered that in a call for heating the outdoor unit would begin cooling. I checked my O wire outside, and I found voltage on it when there shouldn’t be. This indicated that there is a short in the wiring. I checked all of the spare wires to common with all of the wires unhooked from the defrost board. They all had voltage on them with them not being used at the airhandler. This narrowed my search to the wire going to the outdoor unit. I could not locate an obvious short, and I even checked the conduit outside that had water in it. I completely removed the conduit and checked again. I still found that all of the spare wires are shorted. I wired the defrost board back up and it failed. I unhooked O to allow it to heat, and I jumped power from Y to the contactor because it quit passing power. I cycled the unit to ensure it would shut off when satisfied. System is temporarily heating with defrost board bypassed and O unhooked. Customer approved rework for warranty defros
Anna, TX - Upon arrival, I discovered that in a call for heating the outdoor unit would begin cooling. I checked my O wire outside, and I found voltage on it when there shouldn’t be. This indicated that there is a short in the wiring. I checked all of the spare wires to common with all of the wires unhooked from the defrost board. They all had voltage on them with them not being used at the airhandler. This narrowed my search to the wire going to the outdoor unit. I could not locate an obvious short, and I even checked the conduit outside that had water in it. I completely removed the conduit and checked again. I still found that all of the spare wires are shorted. I wired the defrost board back up and it failed. I unhooked O to allow it to heat, and I jumped power from Y to the contactor because it quit passing power. I cycled the unit to ensure it would shut off when satisfied. System is temporarily heating with defrost board bypassed and O unhooked. Customer approved rework for warranty defros
Matthew C.
Matthew C.
Preformed single system maintenance on a 2022 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specification. Filter was recently changed by client. 20x20x4. I tested all electrical components on the outside unit. All tested within manufacturer specifications, except for the start amps were starting higher than 100 amps. We would like to see the amps at about 60 amps on start up. Manufacturer rating is at 130 amps max. A hard start kit will help bring those amps down and help the compressor last longer. I provided estimate to have hard start kit installed. Unit was heating upon departure
Anna, TX 75409
Anna, TX - Preformed single system maintenance on a 2022 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specification. Filter was recently changed by client. 20x20x4. I tested all electrical components on the outside unit. All tested within manufacturer specifications, except for the start amps were starting higher than 100 amps. We would like to see the amps at about 60 amps on start up. Manufacturer rating is at 130 amps max. A hard start kit will help bring those amps down and help the compressor last longer. I provided estimate to have hard start kit installed. Unit was heating upon departure
Anna, TX - Preformed single system maintenance on a 2022 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specification. Filter was recently changed by client. 20x20x4. I tested all electrical components on the outside unit. All tested within manufacturer specifications, except for the start amps were starting higher than 100 amps. We would like to see the amps at about 60 amps on start up. Manufacturer rating is at 130 amps max. A hard start kit will help bring those amps down and help the compressor last longer. I provided estimate to have hard start kit installed. Unit was heating upon departure
Matthew C.
Matthew C.
Upon arrival heat pump was heating in regular mode. Upon further inspection I found the heat kit to be failing at the sequencers. Client elected to have heat kit replaced under warranty.
Anna, TX 75409
Anna, TX - Upon arrival heat pump was heating in regular mode. Upon further inspection I found the heat kit to be failing at the sequencers. Client elected to have heat kit replaced under warranty.
Anna, TX - Upon arrival heat pump was heating in regular mode. Upon further inspection I found the heat kit to be failing at the sequencers. Client elected to have heat kit replaced under warranty.
Matthew C.
Matthew C.
Preformed duct cleaning estimate. Offered several options to have full system cleaned. Along with having air scrubber installed and have a better filtration system installed. Client would like about a week to think it over.
Anna, TX 75409
Anna, TX - Preformed duct cleaning estimate. Offered several options to have full system cleaned. Along with having air scrubber installed and have a better filtration system installed. Client would like about a week to think it over.
Anna, TX - Preformed duct cleaning estimate. Offered several options to have full system cleaned. Along with having air scrubber installed and have a better filtration system installed. Client would like about a week to think it over.
Jesse V.
Jesse V.
Reattached pressure hose
Anna, TX 75409
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Found no issues at his time unit is working well and as intended. Noticed no surge protection on unit. Recommend surge protection in order to protect equipment From surges.
Anna, TX 75409
Anna, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out


Found no issues at his time unit is working well and as intended. Noticed no surge protection on unit. Recommend surge protection in order to protect equipment From surges.
Anna, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out


Found no issues at his time unit is working well and as intended. Noticed no surge protection on unit. Recommend surge protection in order to protect equipment From surges.