Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in January 2026.
The most recent job was on January 7, 2026.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
I performed a single heating maintenance on a 2015 gas system. I checked amps, electrical, cleanliness, and safeties. I noticed the system doesn’t have any safeties assist against clogged drains. The customer mentioned a periodic whistling noise at the return register. I investigated the duct design and confirmed that the system does not currently have enough return air. This issue wears down the system over the course of years. The filter goes in the ceiling and could be in an awkward position allowing this to play a role in the issue. I discovered that the inducer motor is amping out of the manufacture specified range. I referenced passed technicians pictures and determined that the motor is not doing well. The previous tech had an amp reading of .7 compared to my 2.1. I provided options to address these listed items.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Found no issues at this time. Noticed no surge protection on either unit. Recommended surge protection to homeowner to add a layer of protection to equipment. Unit in good working order upon departure.
Preformed 2 system heat maintenance on 2 Goodman furnaces. I tested all electrical components and safeties on both systems. Both systems tested within manufacturer specifications. Temperature being supplied to the up stairs was at 115 and down stairs at 120. Client did not have filters at the time of inspection. Upstairs is 16x25x4 and downstairs is 20x25x4. I. It iced both blower wheels to have dust on them, along with the ducts on both systems. I provided estimates to have them cleaned. I proceeded to the outside unit to visually inspect each one and noticed neither unit had any type of surge protection on them. I provided estimates to have surge protection installed on both outside units client elected to have all estimates done. . Units were working properly upon departure.
I replaced the defrost control board and stumbled across 2 additional issues. After replacement, I rechecked my voltages and found I was now dropping to 15v outside. I verified my voltage was good at the airhandler. I discovered a bad connection in the R wire nut. I redone the connection, and my voltage returned outside. I took a temperature split on the system and it was not very good. I touched the suction pipe and found it to be scalding hot. This indicated that airflow is not very good. I investigated the return air and noticed that the system has only half of the return needed. The system has two 10” ducts. This supplies a total of 600CFM. The system is a 3 ton and requires around 1200CFM return air. I supplied a price to address this issue. This issue adds strain to the compressor, blower motor, and evaporator coil.
Upon arrival, I found that the disconnect breaker was tripped. The breaker is a 30amp but the unit requires a 35amp. I discovered that the compressor is internally shorted. This is likely due to acid in the refrigerant line from a previous repair/replacement. I advised the customer if the best possible repair. That entails replacing the compressor, the TXV, the refrigerant filter, replacing the incorrect breaker(complimentary), and flushing the entire line set with an acid neutralizing chemical. From what I can tell, the unit is in major need of a dump duct above the stairs to limit the amount of liquid refrigerant returning to the compressor. I priced the repair with and without membership. Also, I provided a price to run a 10” dump duct above the stairs. This may not be doable due to limited access. I did not install the hard start due to additional findings.
Upon arrival, I found the indoor unit running, but the outdoor is was nit operating. I checked my voltage to the outdoor. I confirmed my 24v was making it through the low pressure switch. I confirmed that my high pressure switch was closed and passing voltage. I discovered that the voltage was not coming out of the defrost board to the contactor with all other prerequisites met. I jumped the defrost board and got the system to run. I checked my amps and capacitor on the outdoor unit. Everything appears to be in range. Customer has surge protection on the outdoor units. I noticed that both of them are no longer working. I got approval from the customer to proceed with the warranty defrost board. It is on order at Goodman in Allen, and I had it scheduled for 1/6/2026 10am-12am arrival time.
I performed a single heating maintenance on a 2018 zoned heat pump. I checked amps, capacitors, electrical, heating strips, zoning, cleanliness, and safeties. The system is heating fantastic in heat pump mode, but has a failed part in the electric heat strip portion. I only had 2 of the 3 heating strips active. I determined that the strip itself is good, but it is not receiving 240v. I traced it back to the heat sequencer. I ran it for 5mins and the heating strip will not come on. I spoke with the home owner about the importance of surge protection, and I went over the benefits of installing them. Customer did not have a 20x25x4 Honeywell filter at the time of service. I advise that it needs to be replaced.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Blower wheel has dirt/debris and could benefit from having the housing and wheel cleaned. Measured high start amps over 100amps, manufacturer start up amps are rated for 124amps. Advised customer that a hard start kit would help prolong the life of the system. Client is also due for renawak of her membership. Syste
Replaced outdoor fan motor. Fan motor still wasn’t coming on. I inspected the unit further and found that the defrost board was losing voltage. Client has elected to wait on the board and also wants to speak with a comfort advisor.
Install at free or charge outside unit HP-4 ton unit American Standard,5A6H5048A1000AA, 251058LYHF The recipient is a fellow plumber who needed a new completed unit installed.