Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in December 2025.
The most recent job was on December 31, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
I performed a single heating maintenance on a heat pump system. The airhandler is from 2024 and the heat pump is from 2014. I throughly examined the electrical, cleanliness, connections, capacitor, and filter. The system is currently heating with some parts that are failing. The capacitor is reading out of the manufacture specified range. The contactor periodically emits a loud buzzing noise with some burning present on the contacts, the compressor is nearly at the maximum allotted amps during start up. I spoke with the homeowner about improving the filtration to better air quality and keep the system clean, and about the importance of surge protection because of the up coming season.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Unit in good working order upon departure.
Performed a complete heating system maintenance and inspection. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Unit on the inside is straight electric heat and is from 2018. I did find the blower wheel to have dust build up and the evaporator coil both could benefit from a cleaning. I provided estimates to have those task completed. By having them cleaned it can increase the longevity of the system. Verified system temperatures: return air temperature measured at 71°F; supply air temperature measured at 93°F and rising. Confirmed air filter was recently replaced by client; filter size is 20” x 20” x 1”. I visually inspected the outdoor unit. He unit is from 2001 and is R-22. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Inspected / replaced return filter. 7. Inspected return plenum for debris/ dirty. 8. Inspected evaporator coil. 9. Inspected blower motor/ blower wheel. 10. Checked blower amp draw. 11. Measured temperature differential from supply to return. 20 degrees measured. 12. Tested capacitor and contactor (outdoor electrical) 13. Rinsed condenser unit to promote heat exchange 14. Tested electric heat and found no issues Noticed large amount of dust and debris on outdoor unit. This was likely cause of stress on unit that caused refrigerant leak back in October. Rinsed to help promote heat exchange and reduce stress on unit. Notice large amount of dust on evaporator coil and blower wheel. This will cause additional stress on system and ultimately shortening lifespan of the un
Found capacitor testing outside of manufacturer specifications. Failed at 32.4/35 +/-5%. Replaced capacitor under warranty. Unit working upon departure.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Found capacitor testing outside of manufacturer specifications 32.4/35 +/-5%. Replaced under warranty to avoid system failure. Also noticed a large amount of debris on condenser coil. Rinsed coil with visit, however I was unable to remove all the debris without taking the unit apart
I returned to run a camera in the dryer vent and discovered another blockage. Without the camera, I would not have seen it. I informed the customer of the discovery and scheduled a return visit to for December 31 between 8am and 10am to rerun the dryer vent as complementary.
Performed a complete heating system maintenance and inspection gas system 2024 Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. I did find the return ducts and plenum boxes to be dusty. Verified system temperatures: return air temperature measured at 69°F; supply air temperature measured at 120°F and rising. Confirmed air filter was recently replaced by client; filter size is 16” x 25” x 5”. I visually inspected the outside unit. All was in good sound condition visually. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.
Upon arrival, I found the system low by 5 pounds of R410a. I located the leak on the backside of the evaporator coil. I presented options to address this issue. The options included filling it up, filling it up with leak seal, and replacement of the evaporator and condenser. Customer opted to fill it up with leak seal. I informed the customer that there is no warranty or guarantee on repairing it this way. This unit has been refilled and TXV replaced by another company. The TXV is a 1.5T to 3T danfloss. The TXV is not giving me the correct subcooling, but I managed to get a 18 degree temperature drop. Customer is considering replacing the evaporator and condenser but is not ready at this time.
Upon arrival, I found the system was off. I pulled the disconnect for the office unit and turned it on. I opened the outdoor panel and found a spade connector for the fan motor not connected to the capacitor. I connected it and tested the unit. The system is fully operational, but I did notice an issue on the rise. I observed the sub cooling was high and moving erratically after 15 minutes of run time. I proceeded to the attic and took a temperature split. The temperature split was only an 11. I verified warranty on the airhandler and priced a warranty TXV. I provided 2 options. 1. Replace TXV, refrigerant filter, snd reuse current refrigerant 2. Replaced TXV, refrigerant filter, and all of the refrigerant. Replacing all of the refrigerant removes the risk of the refrigerant being contaminated and causing another issue.

