Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX between November 2025 and December 2025.
The most recent job was on December 2, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
Preformed single system heat maintenance on a Goodman heat pump. I tested all electrical components inside. All tested within manufacturer specifications. I did notice there is no high voltage being ran to the second breaker in the air handler. Which isn’t feeding power to some of the heat strips. All other heat strips tested good. I changed the filter for client. 20x20x1. I tested all electrical components on the outside unit. All tested within manufacturer specifications. Unit was heating upon departure.
Arrived on site for heating maintenance and dryer vent cleaning. Everything is working well to the best of the homeowners knowledge. Proceeded with heating maintenance as scheduled. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Also performed dryer vent cleaning and helped homeowner install fitting onto the dryer vent. Unit in
Upon arrival, I installed the heating kit and jumped the kit in and the system began to heat. I rechecked the defrost board and determined it was fully functional. The remaining issue is the thermostat. When the thermostat is bypasses with jumpers, the system is fully operational in heat pump and electric heat. We will need to reach out in the morning to return with a warranty 824 thermostat.
Upon arrival, I found that I was not getting voltage outside. I followed my wiring back inside and it appeared that the thermostat was not passing voltage. I unwired the Y wire and found that my voltage would come back. I proceeded outside and removed the plug from the defrost board. My voltage returned to Y terminal outside. I checked my pressure switches and contactor to ensure they were not shorted. I determined that the defrost board is shorted causing a loss in voltage. I left the defrost board plug undone to see if electric heat would work. Also, it showed a short. When unwiring W from the thermostat my voltage would come back coming out of the thermostat. The heat kit and defrost board is under warranty. Office will contact when part availability is discovered. I left the power off to the indoor and outdoor equipment.
Upon arrival I met with the homeowner Shane. He stated that the blower fan for the bedroom unit would not shut off unless the main breaker was flipped. He did mention that with the storms he had a surge in power. This has been ongoing for about a month. I proceeded to the thermostat where I tested to see if the unit had a short in the low voltage wiring or if the thermostat was bad. Both tested in good working order. I proceeded into the attic where I found that the unit had surge protection on it, but the fan motor was stuck in the on position. After a few test I was able to determine that the blower mower was in fact not working properly. Unit does cool and heat on command. I presented findings to Shane and he elected to have the blower motor replaced. He wants to hold off on signing up for the membership at this time.
I performed a single system heating maintenance on a 2015 heat pump system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. I noticed that the blower has heavy build up present, the outdoor wiring is bare due to u/v damage, and the emergency pan is showing early signs of rusting through. Customer could not move forward with work at this time.
Preformed single system heat maintenance on a 2019 carrier heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I replaced filter for client 20x25x1. Client has the capability for a 20x25x4 filter. I then proceeded outside to test al electrical components on the outside unit. All tested within manufacturer specifications. The Contactor was testing low at 15 ohms. But is still in working condition. I also noticed the unit does not have any surge protection on it. I provided estimates to have he Contactor replaced and surge protection installed on the system. Unit was heating upon departure.
Project Overview We are proposing the installation of a high-efficiency Samsung ductless mini-split system designed to provide dependable comfort, quiet operation, and excellent energy performance. This system is ideal for targeted conditioning of your indoor area while minimizing operating costs. ⸻ Scope of Work 1. Indoor Unit Installation – Wall-Mounted (RXX24AMD) • Install Samsung wall-mounted indoor unit on the designated interior wall. • Secure mounting bracket and ensure proper leveling for optimal condensate drainage. • Run new insulated copper refrigerant lines from indoor unit to outdoor condenser location. • Run new primary drain line and ensure proper pitch for continuous, unrestricted flow. • Seal all wall penetrations for a clean, professional appearance and to prevent air infiltration. • Power and control wiring installed per manufacturer specifications. ⸻ 2. Outdoor Unit Installation – Warehouse Shop (RNX24AMD) • Install outdoor condenser inside the warehous
12” return cut in 2x surge protectors Warranty blower motor 1/5 hp condenser fan motor (capacitor included)
Preformed heat maintenance on a single 2017 gas system. I tested all electrical components and safeties on the inside unit. All tested within manufacturer specifications. Client did not need filter changed at this time. 20x25x4. I proceeded outside to visually inspect the outdoor unit. When I was inspecting the unit I noticed that it did not have surge protection on the system. I provided estimate for installing a surge protector on the unit. Unit was cooling upon departure.

