Menu

Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in November 2025.

The most recent job was on November 25, 2025.

Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Jesse V.
Jesse V.
3 ton warranty replacement compressor- labor cost 6 pounds of R410A refrigerant Refrigerant filter dryer - used to keep the refrigerant clean during operation (discounted refrigerant and dryer because it’s with a major repair)
Anna, TX 75409
Shelby S.
Shelby S.
Upon arrival, I found the system operating in both heating and cooling. The outdoor unit is from 2023 and the indoor is from 2012. I found that in a call for cooling or heating the blower motor would not rev up fully. This would result in a pressure switch to be tripped on the outdoor unit. I turned the cycles off and turned the fan on only. The blower would blow harder in the fan on mode than in cooling/heating mode. This failure was likely due to the unit not getting enough air. The system had minimal return air and a dirty filter. I contacted trane and located the part in McKinney. Customer did not want to move forward with repairs at the time of service. I advised the customer to leave the system off to minimize damage to the outdoor unit/evaporator coil.
Anna, TX 75409
Anna, TX - Upon arrival, I found the system operating in both heating and cooling. The outdoor unit is from 2023 and the indoor is from 2012. I found that in a call for cooling or heating the blower motor would not rev up fully. This would result in a pressure switch to be tripped on the outdoor unit. I turned the cycles off and turned the fan on only. The blower would blow harder in the fan on mode than in cooling/heating mode. This failure was likely due to the unit not getting enough air. The system had minimal return air and a dirty filter. I contacted trane and located the part in McKinney. Customer did not want to move forward with repairs at the time of service. I advised the customer to leave the system off to minimize damage to the outdoor unit/evaporator coil.
Anna, TX - Upon arrival, I found the system operating in both heating and cooling. The outdoor unit is from 2023 and the indoor is from 2012. I found that in a call for cooling or heating the blower motor would not rev up fully. This would result in a pressure switch to be tripped on the outdoor unit. I turned the cycles off and turned the fan on only. The blower would blow harder in the fan on mode than in cooling/heating mode. This failure was likely due to the unit not getting enough air. The system had minimal return air and a dirty filter. I contacted trane and located the part in McKinney. Customer did not want to move forward with repairs at the time of service. I advised the customer to leave the system off to minimize damage to the outdoor unit/evaporator coil.
Matthew C.
Matthew C.
Preformed dryer vent cleaning. Presented before and after pictures of work completed. Preformed 2 system maintenance on gas systems. 2014. I tested all electrical components and safeties for both units. All tested within manufacture specifications. I did notice both blower wheels are dirty and could benefit from a cleaning. Client did not have filters for me to change at this time 20x30x5. Units were cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed dryer vent cleaning. Presented before and after pictures of work completed. 

Preformed 2 system maintenance on gas systems. 2014. I tested all electrical components and safeties for both units. All tested within manufacture specifications. I did notice both blower wheels are dirty and could benefit from a cleaning. Client did not have filters for me to change at this time 20x30x5. Units were cooling upon departure.
Anna, TX - Preformed dryer vent cleaning. Presented before and after pictures of work completed. 

Preformed 2 system maintenance on gas systems. 2014. I tested all electrical components and safeties for both units. All tested within manufacture specifications. I did notice both blower wheels are dirty and could benefit from a cleaning. Client did not have filters for me to change at this time 20x30x5. Units were cooling upon departure.
Brayden W.
Brayden W.
Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split in cooling. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and heat strips without issue. Air balanced system by pinching off master bedroom and closets to push more air to bedrooms in the back of the house. System in good working order upon departure. Thank you for your time.
Anna, TX 75409
Anna, TX - Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split in cooling. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and heat strips without issue. Air balanced system by pinching off master bedroom and closets to push more air to bedrooms in the back of the house. System in good working order upon departure. Thank you for your time.
Anna, TX - Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split in cooling. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation and heat strips without issue. Air balanced system by pinching off master bedroom and closets to push more air to bedrooms in the back of the house. System in good working order upon departure. Thank you for your time.
Matthew C.
Matthew C.
Preformed heating maintenance on a single system heat pump 2021. I tested all electrical components and heat kit on the inside unit. All tested within manufacturer specifications. Temp being supplied to the home was 110 and rising. Return temp to the unit was at 78 degrees. I changed the filter for the client 20x25x4. I did notice that the ducts could benefit from having them cleaned. I proceeded outside where I tested all run and start amps for the compressor and fan motor, along with all the electrical components. All tested within manufacturer specifications. Except for the compressor start amps. They were starting at over 100 amps, rated manufacturer specifications are 83 amps on start up. I also noticed the unit did not have surge protection. I offered estimates for all concerns. Client elected to have hard start kit installed. After installing the hard start kit, I tested the unit’s compressor start amps again and they were now starting at 35 amps. Unit was cooling upon departure
Anna, TX 75409
Anna, TX - Preformed heating maintenance on a single system heat pump 2021. I tested all electrical components and heat kit on the inside unit. All tested within manufacturer specifications. Temp being supplied to the home was 110 and rising. Return temp to the unit was at 78 degrees. I changed the filter for the client 20x25x4. I did notice that the ducts could benefit from having them cleaned. I proceeded outside where I tested all run and start amps for the compressor and fan motor, along with all the electrical components. All tested within manufacturer specifications. Except for the compressor start amps. They were starting at over 100 amps, rated manufacturer specifications are 83 amps on start up. I also noticed the unit did not have surge protection. I offered estimates for all concerns. Client elected to have hard start kit installed. After installing the hard start kit, I tested the unit’s compressor start amps again and they were now starting at 35 amps. Unit was cooling upon departure
Anna, TX - Preformed heating maintenance on a single system heat pump 2021. I tested all electrical components and heat kit on the inside unit. All tested within manufacturer specifications. Temp being supplied to the home was 110 and rising. Return temp to the unit was at 78 degrees. I changed the filter for the client 20x25x4. I did notice that the ducts could benefit from having them cleaned. I proceeded outside where I tested all run and start amps for the compressor and fan motor, along with all the electrical components. All tested within manufacturer specifications. Except for the compressor start amps. They were starting at over 100 amps, rated manufacturer specifications are 83 amps on start up. I also noticed the unit did not have surge protection. I offered estimates for all concerns. Client elected to have hard start kit installed. After installing the hard start kit, I tested the unit’s compressor start amps again and they were now starting at 35 amps. Unit was cooling upon departure
Brayden W.
Brayden W.
Arrived on site for heating maintenance on 2017 Armstrong air furnace. Homeowner stated he was smelling a dusty smell when the unit kicked on. I asked the homeowner if it was more of a dirty sock smell and he confirmed. I started by cracking open the evaporator coil and inspecting. I noticed a very slight amount of debris around the evaporator and I could not notice any smell coming from the evaporator when I put my head in there. Inspected plenums and noticed a large amount of dust buildup. Proceeded with maintenance as scheduled. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually ins
Anna, TX 75409
Anna, TX - Arrived on site for heating maintenance on 2017 Armstrong air furnace. Homeowner stated he was smelling a dusty smell when the unit kicked on. I asked the homeowner if it was more of a dirty sock smell and he confirmed. I started by cracking open the evaporator coil and inspecting. I noticed a very slight amount of debris around the evaporator and I could not notice any smell coming from the evaporator when I put my head in there. Inspected plenums and noticed a large amount of dust buildup.  Proceeded with maintenance as scheduled.
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually ins
Anna, TX - Arrived on site for heating maintenance on 2017 Armstrong air furnace. Homeowner stated he was smelling a dusty smell when the unit kicked on. I asked the homeowner if it was more of a dirty sock smell and he confirmed. I started by cracking open the evaporator coil and inspecting. I noticed a very slight amount of debris around the evaporator and I could not notice any smell coming from the evaporator when I put my head in there. Inspected plenums and noticed a large amount of dust buildup.  Proceeded with maintenance as scheduled.
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually ins
Brayden W.
Brayden W.
Arrived on site for no cool, due to clogged drain line. Homeowner noticed water coming out of the secondary drain line. Homeowner stated everything else was working well to his knowledge. Began inspection at vent stack and noticed there was no water. This is likely because the homeowner had the unit off for sometime and it could drain slowly. I then tested the drain line by pouring half a gallon down the drain line and sure enough it backed up to the vent stack. Perform cursory inspection of outdoor unit and found nothing of immediate concern, however, we will need to further inspect when we come back out for the maintenance. Discussed possible options for drain line unclogging including blowout valve and float switch. Homeowner elected for a level one drain clearing and maintenance performed drain line clearing, including blowing out the drain line with nitrogen and disassembling the upstairs sink where the drain line ties in and cleaning out any blockages I could find there. Showed v
Anna, TX 75409
Anna, TX - Arrived on site for no cool, due to clogged drain line. Homeowner noticed water coming out of the secondary drain line. Homeowner stated everything else was working well to his knowledge. Began inspection at vent stack and noticed there was no water. This is likely because the homeowner had the unit off for sometime and it could drain slowly. I then tested the drain line by pouring half a gallon down the drain line and sure enough it backed up to the vent stack. Perform cursory inspection of outdoor unit and found nothing of immediate concern, however, we will need to further inspect when we come back out for the maintenance. Discussed possible options for drain line unclogging including blowout valve and float switch. Homeowner elected for a level one drain clearing and maintenance performed drain line clearing, including blowing out the drain line with nitrogen and disassembling the upstairs sink where the drain line ties in and cleaning out any blockages I could find there. Showed v
Anna, TX - Arrived on site for no cool, due to clogged drain line. Homeowner noticed water coming out of the secondary drain line. Homeowner stated everything else was working well to his knowledge. Began inspection at vent stack and noticed there was no water. This is likely because the homeowner had the unit off for sometime and it could drain slowly. I then tested the drain line by pouring half a gallon down the drain line and sure enough it backed up to the vent stack. Perform cursory inspection of outdoor unit and found nothing of immediate concern, however, we will need to further inspect when we come back out for the maintenance. Discussed possible options for drain line unclogging including blowout valve and float switch. Homeowner elected for a level one drain clearing and maintenance performed drain line clearing, including blowing out the drain line with nitrogen and disassembling the upstairs sink where the drain line ties in and cleaning out any blockages I could find there. Showed v
Brayden W.
Brayden W.
Testing service field app
Anna, TX 75409
Shelby S.
Shelby S.
Upon arrival, I found a 2020 gas system operating normally. I began running tests and found the system not making a noise. Customer produced a video of the issue. It appears the module is failing on the X13 blower motor. Customer had the control board replaced last year. I thoroughly examined the system. I found that the system does not have enough return air, the condenser fan motor is squeaking upon start up, the capacitor on the outdoor unit is under manufacture specification, and I offered surge protectors for the indoor/outdoor units. The furnace is under warranty until 2026 and the outdoor has an expired warranty. I provided an option to address these issues. Customer would like to wait until Thursday before deciding.
Anna, TX 75409
Anna, TX - Upon arrival, I found a 2020 gas system operating normally. I began running tests and found the system not making a noise. Customer produced a video of the issue. It appears the module is failing on the X13 blower motor. Customer had the control board replaced last year. I thoroughly examined the system. I found that the system does not have enough return air, the condenser fan motor is squeaking upon start up, the capacitor on the outdoor unit is under manufacture specification, and I offered surge protectors for the indoor/outdoor units. The furnace is under warranty until 2026 and the outdoor has an expired warranty. I provided an option to address these issues. Customer would like to wait until Thursday before deciding.
Anna, TX - Upon arrival, I found a 2020 gas system operating normally. I began running tests and found the system not making a noise. Customer produced a video of the issue. It appears the module is failing on the X13 blower motor. Customer had the control board replaced last year. I thoroughly examined the system. I found that the system does not have enough return air, the condenser fan motor is squeaking upon start up, the capacitor on the outdoor unit is under manufacture specification, and I offered surge protectors for the indoor/outdoor units. The furnace is under warranty until 2026 and the outdoor has an expired warranty. I provided an option to address these issues. Customer would like to wait until Thursday before deciding.
Shelby S.
Shelby S.
Upon arrival, I found the breaker to the outdoor unit tripped in the main panel. I reset the outdoor unit and tested the starting amps. It is pulling almost twice the rated. I reached out to the landlord to speak on options. I attempted to get it started with a hard start kit. The compressor still would not start. I reached back out to the landlord about compressor replacement. The lead time I received from the supply house was 7-10 days. The compressor is on order and set to arrive in Allen.