Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in September 2025.
The most recent job was on September 19, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
Arrived to unit not cooling properly for main portion of the home. I diagnosed a failed contactor on the outdoor unit. I called the home owner and he declined the repair. He also declined to pay for the dispatch/ diagnostic fee. He will contact American home sheild( home warranty) for the repair. Unit is not running.
I performed a single system heating check on a 2020 gas system. The system is an up flow in a closet. I checked amps, capacitor, filter, drains, electrical, flame sensor, igniter, cleanliness, and blower. The system is performing to manufacture specifications. The customer informed me of an issue with the thermostat. I found that the thermostat is warm causing it to read higher than the temperature in the room. After investigation, I discovered that she had her insulation removed and replaced. The thermostat is reading about 2 degrees higher than it should. Customer stated the issue showed up after the insulation was done. I stuck my temperature probe in the hole behind the thermostat. It was reading reading 88 degrees. I proposed an option to add a wireless sensor to another part of the house for a more accurate temperature. The air analysis showed the home is high in VOCs and carbon dioxide. With the limited access, there is not a way to put a fresh air intake on the HVAC equipment.
Arrived on site, home owner noticed water coming through ceiling below unit. 2015 heat pump. Found clogged drain line upon inspecting p trap and float switch. Unit was not shutting off when float switch was triggered. Also noticed line set insulation was leaking a substantial amount of water from poor connections. Proceeding to the outdoor unit I noticed oil around the suction line. I then checked for a leak at the valve core and found a refrigerant leak. Tightened valve core and leak went away. I then measured refrigerant pressures on the unit and found them to be slightly low, however I was not able to take accurate pressures as the outdoor unit was extremely dirty. I then tested the electrical on the outdoor unit and found the capacitor and contactor testing outside of manufacturer specifications. The contactor also had signs of pitting/burning and was also making a loud buzzing noise. The contactor allows power into the unit when the thermostat calls for it, and the capacitor adds
Retuned to our clients home to address uneven temperature throughout the home. We were able to coordinate the visit with Brenda and she gave us data to help understand the airflow concerns she was experiencing. We first proceeded to ensure that both damper motors were working properly. Once we confirmed that both damper motors were working properly we proceeded to test and measure airflow for the upstairs zone only first. I had Brenda follow me while Mathew adjusted the dampers from the attic. We immediately identified that the large supply vent directly over the second story rafters was pushing a significant amount of air out of it. We were able to damper this down and ensure other bedrooms for the upstairs zone were more evenly dispersed. We made all of the adjustments to Brenda’s satisfaction upstairs before pending the downstairs zone. When we ran both zones she measured how much the airflow was reduced. She agreed to monitor the home and airflow for 2 weeks and we also set the exp
Preformed a heating maintenance on a 2013 carrier straight electric single system. Tested all electrical and safeties on the heat kit. We found that one of the 5kw strips is not working properly. We also found that the blower and evaporator coil on the inside unit is extremely covered with dirt/debris. We have provided estimates for all concerns with the system at this time. Unit was shut off upon departure just as it was when we arrived. Scheduled to return 9/17/25 @10:00-12:00
Arrived on site, homeowner stated the unit was not keeping up with the set point. We initially proceeded to the furnace and found condenser running the drain line to be clear. Unit was expelling 80 degree air while compressor was running. At this point we measured refrigerant pressures and found them to be low. We then proceeded to the indoor coil and found a leak in the evaporator coil(video attached). We turned the breaker off at the condenser at this time to prevent further damage. We then provided the home owner options for addressing this issue. 1. Recharge system and leave it 2. Recharge and leak seal. 3 system replacement. Homeowner opted to replace the system with a 3.5 Ton AC-Gas System: Silver 14 and was available for the installation on Friday at 8:00. Deposit collected and remaining balance will be payed with credit card. Customer would like to keep his turbo capacitor from old system.
system was not cooling due to pitted contactor. Replaced contactor under parts and labor warranty. after installation, checked system and system is running and cooling to manufacture specification.
Heat preventative maintenance on a heat pump from 2023 using air filter size aprilaire 910. Upon arrival the customer stated that the system has been running good without any issues but has noticed some dust around the house. The system does have a uv light and it’s still working, I recommended to swap the filter out every 3-4 months instead of the 6 months to help out with the dust because her ductwork is clean. During my inspection I checked temperatures, amps draws on heat strips, checked electrical connections and components, and changed the air filter out today. I did find a burning and arcing contactor due to the compressor starting heavy, it’s rated for 104 LRA and I’m reading 128 today. I got the customer involved and showed her a video I made and she decided to get a compressor saver today and we will be replacing the contactor under her 10 year parts and labor warranty. After repair I checked the compressor start amps and they were within range. System is heating proper
Client called in stating that their thermostat had no power and wasn’t connecting to their Wi-Fi. Upon arrival I inspected the thermostat and it was blank, i proceeded to check the up flow closet unit. I found the safety float switch to be tripped which is indicating a clog in the drain line, present customer with my findings and he elected to have he drain line cleared. I cleared the drain line and tested the drain line to insure it would drain properly. I treated the line with total c. Client also elected to sign up for our annual maintenance service. Unit was cooling upon departure.
Returned to our clients home to preform another inspection on the finished home. The HVAC system has not changed or been addressed from the previous visits. The system is a 5 ton single stage AC with a 90% furnace for a 3500 sq ft home. The unit is undersized according to the manual J I ran today at the home. I ran the manual J with an average outdoor temperature of 110º and it was closer to 7 tons. There is not enough air being supplied to the entry way of the home. The master bedroom and one of the smaller bedrooms have the return grill within 4 feet of the supply air in the room. There is a large gaps present on the evaporator coil that is allowing a significant amount of air to leak. This is due to a compromised cabinet door that needs to be secured shut. There are several gaps in the return box, a the filter hits the closet door making it inconvenient and difficult to remove and replace. There are several temperature discrepancies between the supply vents in the home some of