Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in August 2025.

The most recent job was on August 18, 2025.

Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
Upon arrival, i discovered the outdoor unit tripping the breaker. I removed the panel of the outdoor unit and found the capacitor for the compressor bloated. This indicates that the internal seals have ruptured. Customer approved the replacement of the capacitor with a generic capacitor. I took notice that the system is in need of some other things. It could use a contactor because the ohm value is at its peak for normal range with heavy burning on the contacts. This can lead to the contactor shorting out or becoming welded shut. The outdoor unit is matted with debris and causing a restriction. This will cause the unit to not cool as efficiently or may result in the compressor tripping on thermal overload. The compressor is starting with high amps. This will wear down the compressor over time causing the compressor to ultimately fail. While I was checking the refrigerant pressures, I noticed that this system is way over charged. I’m assuming that, with the unit having an active leak, i
Anna, TX 75409
Anna, TX - Upon arrival, i discovered the outdoor unit tripping the breaker. I removed the panel of the outdoor unit and found the capacitor for the compressor bloated. This indicates that the internal seals have ruptured. Customer approved the replacement of the capacitor with a generic capacitor. I took notice that the system is in need of some other things. It could use a contactor because the ohm value is at its peak for normal range with heavy burning on the contacts. This can lead to the contactor shorting out or becoming welded shut. The outdoor unit is matted with debris and causing a restriction. This will cause the unit to not cool as efficiently or may result in the compressor tripping on thermal overload. The compressor is starting with high amps. This will wear down the compressor over time causing the compressor to ultimately fail. While I was checking the refrigerant pressures, I noticed that this system is way over charged. I’m assuming that, with the unit having an active leak, i
Anna, TX - Upon arrival, i discovered the outdoor unit tripping the breaker. I removed the panel of the outdoor unit and found the capacitor for the compressor bloated. This indicates that the internal seals have ruptured. Customer approved the replacement of the capacitor with a generic capacitor. I took notice that the system is in need of some other things. It could use a contactor because the ohm value is at its peak for normal range with heavy burning on the contacts. This can lead to the contactor shorting out or becoming welded shut. The outdoor unit is matted with debris and causing a restriction. This will cause the unit to not cool as efficiently or may result in the compressor tripping on thermal overload. The compressor is starting with high amps. This will wear down the compressor over time causing the compressor to ultimately fail. While I was checking the refrigerant pressures, I noticed that this system is way over charged. I’m assuming that, with the unit having an active leak, i
Matthew C.
Matthew C.
Upon arrival I spoke with homeowners husband. He stated that the air was blowing hot through the house and it started doing this the night before. Customer had changed filters. I went to the outside unit and noticed that the condenser fan motor was run in but the compressor was not. I tested the capacitor on the outside unit and found it to be dead. 5/45 and 2/5. I presented findings to the customer. Customer elected to have the capacitor replaced with a turbo 200. After installing the new capacitor. I tested start and run amps on the fan and compressor motors. The compressor was starting on high amps. I presented the findings to the customer and provided estimate for the hard start kit. Unit was cooling upon departure TURBO200 MULTI USE CAPACITOR 2.5-67.5 MFD 370 - 440V SIMILAR TO A BATTERY, CAPACITORS HELP START MOTORS BY STORING CURRENT. A DAMAGED CAPACITOR CAN DAMAGE THE MOTOR IF NOT SERVICED. REGULAR MAINTENANCE IS ENCOURAGED.
Anna, TX 75409
Anna, TX - Upon arrival I spoke with homeowners husband. He stated that the air was blowing hot through the house and it started doing this the night before. Customer had changed filters. I went to the outside unit and noticed that the condenser fan motor was run in but the compressor was not. I tested the capacitor on the outside unit and found it to be dead. 5/45 and 2/5. I presented findings to the customer. Customer elected to have the capacitor replaced with a turbo 200. After installing the new capacitor. I tested start and run amps on the fan and compressor motors. The compressor was starting on high amps. I presented the findings to the customer and provided estimate for the hard start kit. Unit was cooling upon departure 

TURBO200 MULTI USE CAPACITOR

2.5-67.5 MFD 370 - 440V

SIMILAR TO A BATTERY, CAPACITORS HELP START MOTORS BY STORING CURRENT. A DAMAGED CAPACITOR CAN DAMAGE THE MOTOR IF NOT SERVICED. REGULAR MAINTENANCE IS ENCOURAGED.
Anna, TX - Upon arrival I spoke with homeowners husband. He stated that the air was blowing hot through the house and it started doing this the night before. Customer had changed filters. I went to the outside unit and noticed that the condenser fan motor was run in but the compressor was not. I tested the capacitor on the outside unit and found it to be dead. 5/45 and 2/5. I presented findings to the customer. Customer elected to have the capacitor replaced with a turbo 200. After installing the new capacitor. I tested start and run amps on the fan and compressor motors. The compressor was starting on high amps. I presented the findings to the customer and provided estimate for the hard start kit. Unit was cooling upon departure 

TURBO200 MULTI USE CAPACITOR

2.5-67.5 MFD 370 - 440V

SIMILAR TO A BATTERY, CAPACITORS HELP START MOTORS BY STORING CURRENT. A DAMAGED CAPACITOR CAN DAMAGE THE MOTOR IF NOT SERVICED. REGULAR MAINTENANCE IS ENCOURAGED.
Shelby S.
Shelby S.
We preformed 3 system maintenance all were heat pumps. We tested all electrical components on the 3 inside units upstairs. All electrical was testing within manufacturer specifications range. We treated the main drain lines with total c and changed all 3 filters. Temp split across the coils was reading with range. We proceeded outside to test all the electrical components along with start and run amps of the compressor and fan motors. All electrical on the upstairs unit and living room unit tested within manufacturer specifications range. Both of these units were starting at high start amps and could benefit from having a hard start kit installed. The master bedroom units electrical components tested within manufacturer specifications except for the Contactor which was reading at 21ohms. Run and start amps for the compressor and fan motors were testing within manufacturer specifications range. We provided estimates for each concern we found. We rinsed the outdoor coils. Units were cool
Anna, TX 75409
Anna, TX - We preformed 3 system maintenance all were heat pumps. We tested all electrical components on the 3 inside units upstairs. All electrical was testing within manufacturer specifications range. We treated the main drain lines with total c and changed all 3 filters. Temp split across the coils was reading with range. We proceeded outside to test all the electrical components along with start and run amps of the compressor and fan motors. All electrical on the upstairs unit and living room unit tested within manufacturer specifications range. Both of these units were starting at high start amps and could benefit from having a hard start kit installed. The master bedroom units electrical components tested within manufacturer specifications except for the Contactor which was reading at 21ohms. Run and start amps for the compressor and fan motors were testing within manufacturer specifications range. We provided estimates for each concern we found. We rinsed the outdoor coils. Units were cool
Anna, TX - We preformed 3 system maintenance all were heat pumps. We tested all electrical components on the 3 inside units upstairs. All electrical was testing within manufacturer specifications range. We treated the main drain lines with total c and changed all 3 filters. Temp split across the coils was reading with range. We proceeded outside to test all the electrical components along with start and run amps of the compressor and fan motors. All electrical on the upstairs unit and living room unit tested within manufacturer specifications range. Both of these units were starting at high start amps and could benefit from having a hard start kit installed. The master bedroom units electrical components tested within manufacturer specifications except for the Contactor which was reading at 21ohms. Run and start amps for the compressor and fan motors were testing within manufacturer specifications range. We provided estimates for each concern we found. We rinsed the outdoor coils. Units were cool
jcg311690@gmail.com
jcg311690@gmail.com
Ac preventative maintenance on two gas systems from 2017, air filters for both systems are 20*25*4 Customer stated that they’ve done some repairs outside prior to my visit. She also mentioned if it was normal to see a lot of dust coming out of the vents. During my inspection I changed the downstairs system air filter and the upstairs filter was still in good condition. I checked temperatures, checked electrical connections and components, washed the coils outside, and inspected the system for dirt buildup. I did find both systems to have dirt buildup throughout their entire ductwork and within themselves. I brought it up to the customer and let her know that this is the reason why there’s a lot of dust around the vents. She asked if we can clean the entire system and how much, I informed her that I was going to check the rest of the systems to see if the dirt is affecting anything else besides the dirty vents and that once I get a full picture of how the systems are running I will b
Anna, TX 75409
Jacob P.
Jacob P.
Arrived for concerns that the unit was not cooling properly again. Our clients had purchased a replacement thermostat and requested I install it for her. Once the new thermostat was installed I proceeded to test the unit and ensured it was cooling properly. It was cooling with a standard 20º drop. The the thermostat was reading 86º when installed and dropped to 83º on departure.
Anna, TX 75409
Anna, TX - Arrived for concerns that the unit was not cooling properly again. Our clients had purchased a replacement thermostat and requested I install it for her. Once the new thermostat was installed I proceeded to test the unit and ensured it was cooling properly. It was cooling with a standard 20º drop. The the thermostat was reading 86º when installed and dropped to 83º on departure.
Anna, TX - Arrived for concerns that the unit was not cooling properly again. Our clients had purchased a replacement thermostat and requested I install it for her. Once the new thermostat was installed I proceeded to test the unit and ensured it was cooling properly. It was cooling with a standard 20º drop. The the thermostat was reading 86º when installed and dropped to 83º on departure.
jcg311690@gmail.com
jcg311690@gmail.com
Demand call for water marks on the ceiling. Upon arrival the customer showed me the marks on the ceiling and where the attic access was. I followed the drain line to see if it went in that area where the water damage was and it did. I inspected the drain lines for cracks or for pipe being disconnected but I didn’t find anything. However the pvc is sweating a lot and it’s dripping right over the spot where the water damage is. I took a video of it and got the customer involved. I explained to him that we need to put insulation on the pipe to stop it from sweating, he agreed and allowed me to add about 2 feet of insulation on it. I informed the customer that that should stop the pvc from sweating but the insulation is still wet and that can still cause damage, customer understands but is happy we addressed the cause of the problem. System is running upon departure
Anna, TX 75409
Matthew C.
Matthew C.
Demand call for heat pump from 2018 with air filter size 16*25*4 not having power to thermostat or outside unit. Upon arrival customer stated that her neighbor replaced the control board in the air handler and transformer. But even after the repairs the thermostat will turn off in ac mode and nothing will work. During my inspection I found the system in the attic to be off at the breaker. I turned it on and the fan turned on, I went to the thermostat and turned it to ac mode and fan in auto. The system up in the attic turned on but the outdoor didn’t and the fuse popped. I informed the customer that we have a short in the system and will have to charge her according to how long it took to find the short. After finding the short customer agreed to get it fixed, after the repair I turned the system back on and noticed her heat strips were kicking on at the same time as the ac. I checked the thermostat wiring and and found it to be incorrect, after fixing that I turned the system back
Anna, TX 75409
Anna, TX - Demand call for heat pump from 2018 with air filter size 16*25*4 not having power to thermostat or outside unit. 

Upon arrival customer stated that her neighbor replaced the control board in the air handler and transformer. But even after the repairs the thermostat will turn off in ac mode and nothing will work. 
During my inspection I found the system in the attic to be off at the breaker. I turned it on and the fan turned on, I went to the thermostat and turned it to ac mode and fan in auto. The system up in the attic turned on but the outdoor didn’t and the fuse popped. I informed the customer that we have a short in the system and will have to charge her according to how long it took to find the short. After finding the short customer agreed to get it fixed, after the repair I turned the system back on and noticed her heat strips were kicking on at the same time as the ac. I checked the thermostat wiring and and found it to be incorrect, after fixing that I turned the system back
Anna, TX - Demand call for heat pump from 2018 with air filter size 16*25*4 not having power to thermostat or outside unit. 

Upon arrival customer stated that her neighbor replaced the control board in the air handler and transformer. But even after the repairs the thermostat will turn off in ac mode and nothing will work. 
During my inspection I found the system in the attic to be off at the breaker. I turned it on and the fan turned on, I went to the thermostat and turned it to ac mode and fan in auto. The system up in the attic turned on but the outdoor didn’t and the fuse popped. I informed the customer that we have a short in the system and will have to charge her according to how long it took to find the short. After finding the short customer agreed to get it fixed, after the repair I turned the system back on and noticed her heat strips were kicking on at the same time as the ac. I checked the thermostat wiring and and found it to be incorrect, after fixing that I turned the system back
Shelby S.
Shelby S.
Upon arrival, I discovered that the blower was moving air through the house. I proceeded outside and found that the outdoor unit was not operational. I opened the panel and found that the contactor was not pulled in. The system does not have any pressure switches. I went into the attic and found the Aprilaire fresh air damper control halfway on. I secured it back into the place and it came back on. I removed the doors to the furnace and the door switch tripped causing the unit to resell. After the time delay, the unit kicked on fully functional and cooling. I spoke with the homeowner about the issue. I speculate that either the control board or the thermostat is having an intermittent issue. I checked out the unit and noticed that the TXV is having an issue with the possibility of the refrigerant being contaminated and the 45/5 capacitor is reading 22/45. **30 day recall window expires 9/14/25** Unit is a 2020 Goodman gas system - not communicating or zoned
Anna, TX 75409
Anna, TX - Upon arrival, I discovered that the blower was moving air through the house. I proceeded outside and found that the outdoor unit was not operational. I opened the panel and found that the contactor was not pulled in. The system does not have any pressure switches. I went into the attic and found the Aprilaire fresh air damper control halfway on. I secured it back into the place and it came back on. I removed the doors to the furnace and the door switch tripped causing the unit to resell. After the time delay, the unit kicked on fully functional and cooling. I spoke with the homeowner about the issue. I speculate that either the control board or the thermostat is having an intermittent issue. I checked out the unit and noticed that the TXV is having an issue with the possibility of the refrigerant being contaminated and the 45/5 capacitor is reading 22/45.
**30 day recall window expires 9/14/25**

Unit is a 2020 Goodman gas system - not communicating or zoned
Anna, TX - Upon arrival, I discovered that the blower was moving air through the house. I proceeded outside and found that the outdoor unit was not operational. I opened the panel and found that the contactor was not pulled in. The system does not have any pressure switches. I went into the attic and found the Aprilaire fresh air damper control halfway on. I secured it back into the place and it came back on. I removed the doors to the furnace and the door switch tripped causing the unit to resell. After the time delay, the unit kicked on fully functional and cooling. I spoke with the homeowner about the issue. I speculate that either the control board or the thermostat is having an intermittent issue. I checked out the unit and noticed that the TXV is having an issue with the possibility of the refrigerant being contaminated and the 45/5 capacitor is reading 22/45.
**30 day recall window expires 9/14/25**

Unit is a 2020 Goodman gas system - not communicating or zoned
Shelby S.
Shelby S.
I investigated the air balance issues. I found that the thermostat above the upstairs thermostat was not reading the correct temperature. I observed that the supply grill in that same room is teasing the thermostat by blowing cool air on it. I toned back the air to that room in an attempt to get the thermostat to read correctly. I calibrated the upstairs thermostat to make it read more on par of what it truly is. With the upstairs thermostat being where it is, we may need to replace the supply grill to a scoop style to keep the air off of it or even had an external sensor to the room across the hallway. Please allow 2 weeks for adjustments to acclimate to the home.
Anna, TX 75409
Anna, TX - I investigated the air balance issues. I found that the thermostat above the upstairs thermostat was not reading the correct temperature. I observed that the supply grill in that same room is teasing the thermostat by blowing cool air on it. I toned back the air to that room in an attempt to get the thermostat to read correctly. I calibrated the upstairs thermostat to make it read more on par of what it truly is. With the upstairs thermostat being where it is, we may need to replace the supply grill to a scoop style to keep the air off of it or even had an external sensor to the room across the hallway. Please allow 2 weeks for adjustments to acclimate to the home.
Anna, TX - I investigated the air balance issues. I found that the thermostat above the upstairs thermostat was not reading the correct temperature. I observed that the supply grill in that same room is teasing the thermostat by blowing cool air on it. I toned back the air to that room in an attempt to get the thermostat to read correctly. I calibrated the upstairs thermostat to make it read more on par of what it truly is. With the upstairs thermostat being where it is, we may need to replace the supply grill to a scoop style to keep the air off of it or even had an external sensor to the room across the hallway. Please allow 2 weeks for adjustments to acclimate to the home.
Shelby S.
Shelby S.
I performed a single system cooling maintenance on a 2021 Zoned/communicating heat pump system. I checked amps, capacitors, filter, cleanliness, electrical, drains, and safeties. The system is cooling properly with some noted issues. The capacitor is beginning to read weak. This is normal wear and tear. The typical life span of a capacitor is 3-5 years. The compressor is starting with a higher than recommended amp pull. This causes damage to the compressor and other electrical components over time. The outdoor unit is covered in vegetation and NEEDS a thorough cleaning. The damper motor controlling the downstairs was stuck when I arrived. This was causing the downstairs to cool poorly and the airhandler to sweat due not being able to move air properly. I managed to get the damper to open fully, but I foresee this issue reoccurring. I presented options to address these issues and the customer declined.
Anna, TX 75409
Anna, TX - I performed a single system cooling maintenance on a 2021 Zoned/communicating heat pump system. I checked amps, capacitors, filter, cleanliness, electrical, drains, and safeties. The system is cooling properly with some noted issues. The capacitor is beginning to read weak. This is normal wear and tear. The typical life span of a capacitor is 3-5 years. The compressor is starting with a higher than recommended amp pull. This causes damage to the compressor and other electrical components over time. The outdoor unit is covered in vegetation and NEEDS a thorough cleaning. The damper motor controlling the downstairs was stuck when I arrived. This was causing the downstairs to cool poorly and the airhandler to sweat due not being able to move air properly. I managed to get the damper to open fully, but I foresee this issue reoccurring. I presented options to address these issues and the customer declined.
Anna, TX - I performed a single system cooling maintenance on a 2021 Zoned/communicating heat pump system. I checked amps, capacitors, filter, cleanliness, electrical, drains, and safeties. The system is cooling properly with some noted issues. The capacitor is beginning to read weak. This is normal wear and tear. The typical life span of a capacitor is 3-5 years. The compressor is starting with a higher than recommended amp pull. This causes damage to the compressor and other electrical components over time. The outdoor unit is covered in vegetation and NEEDS a thorough cleaning. The damper motor controlling the downstairs was stuck when I arrived. This was causing the downstairs to cool poorly and the airhandler to sweat due not being able to move air properly. I managed to get the damper to open fully, but I foresee this issue reoccurring. I presented options to address these issues and the customer declined.