Heating and Air Conditioning Services in Anna, TX

Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.

Schedule Service in AnnaCall (903) 482-4900

HVAC Services in Anna, TX

Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:

AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.

AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.

Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.

Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.

Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.

Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.

HVAC Services for Anna’s Growing Neighborhoods

Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.

For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.

Why Anna Homeowners Choose Adon Complete

Schedule Service in AnnaCall (903) 482-4900

Frequently Asked Questions

Here are some answers to common questions we get about our Anna HVAC services.

How much does AC repair cost in Anna, TX?

Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Anna?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.

What HVAC brands do you service in Anna?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.

Do you offer HVAC maintenance plans in Anna?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.

What areas near Anna do you serve?

We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.

Schedule HVAC Service in Anna Today

We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in AnnaCall (903) 482-4900

Recent Jobs and Reviews in Anna, TX

Rated 4.9 out of 5 stars based on 67 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Anna, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in August 2025.

The most recent job was on August 14, 2025.

Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.

Job Locations

Shelby S.
Shelby S.
I performed a 2 system cooling maintenance on a 2024 and 2021 communicating gas systems. I checked amps, filters, electrical, drains, cleanliness, and safeties. The customer informed me of the upstairs being uncomfortable. I briefly investigated and found that the return was directly next to the push out attic access. The thermostat is directly near the attic door. The customer spoke about a power surge that happened during the lightning storm. This could’ve possibly damaged the thermostat. I adjusted the temperature offset and activated humidity control. Customer wanted pricing on sensors, air balance, and surge protection for the upstairs unit.
Anna, TX 75409
Anna, TX - I performed a 2 system cooling maintenance on a 2024 and 2021 communicating gas systems. I checked amps, filters, electrical, drains, cleanliness, and safeties. The customer informed me of the upstairs being uncomfortable. I briefly investigated and found that the return was directly next to the push out attic access. The thermostat is directly near the attic door. The customer spoke about a power surge that happened during the lightning storm. This could’ve possibly damaged the thermostat. I adjusted the temperature offset and activated humidity control. Customer wanted pricing on sensors, air balance, and surge protection for the upstairs unit.
Anna, TX - I performed a 2 system cooling maintenance on a 2024 and 2021 communicating gas systems. I checked amps, filters, electrical, drains, cleanliness, and safeties. The customer informed me of the upstairs being uncomfortable. I briefly investigated and found that the return was directly next to the push out attic access. The thermostat is directly near the attic door. The customer spoke about a power surge that happened during the lightning storm. This could’ve possibly damaged the thermostat. I adjusted the temperature offset and activated humidity control. Customer wanted pricing on sensors, air balance, and surge protection for the upstairs unit.
Matthew C.
Matthew C.
Preformed cooling maintenance on 2014 Goodman single system. Speaking with the homeowner the only concern that he had was the main drain line was producing water along it. We began our inspection on the inside unit by testing all electrical components, we treated the drain line with total c and changed the filter. The filter was extremely dirty which can cause the evaporator coil to sweat more and cause the drain line to condensate more than usual. We inspected the cleanliness of the ducts, evaporator coil and blower motor. We found both to be dirty with debris and dust. We proceeded outside and tested all electrical components, run and start amps of the compressor and fan motor. All tested within manufacturer specifications except for the Contactor and start amps of he compressor. We provided estimates for a Full system cleaning, hard start kit and new contactor. Unit was cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed cooling maintenance on 2014 Goodman single system. Speaking with the homeowner the only concern that he had was the main drain line was producing water along it. We began our inspection on the inside unit by testing all electrical components, we treated the drain line with total c and changed the filter. The filter was extremely dirty which can cause the evaporator coil to sweat more and cause the drain line to condensate more than usual. We inspected the cleanliness of the ducts, evaporator coil and blower motor. We found both to be dirty with debris and dust. We proceeded outside and tested all electrical components, run and start amps of the compressor and fan motor. All tested within manufacturer specifications except for the Contactor and start amps of he compressor. We provided estimates for a Full system cleaning, hard start kit and new contactor. Unit was cooling upon departure.
Anna, TX - Preformed cooling maintenance on 2014 Goodman single system. Speaking with the homeowner the only concern that he had was the main drain line was producing water along it. We began our inspection on the inside unit by testing all electrical components, we treated the drain line with total c and changed the filter. The filter was extremely dirty which can cause the evaporator coil to sweat more and cause the drain line to condensate more than usual. We inspected the cleanliness of the ducts, evaporator coil and blower motor. We found both to be dirty with debris and dust. We proceeded outside and tested all electrical components, run and start amps of the compressor and fan motor. All tested within manufacturer specifications except for the Contactor and start amps of he compressor. We provided estimates for a Full system cleaning, hard start kit and new contactor. Unit was cooling upon departure.
jcg311690@gmail.com
jcg311690@gmail.com
Demand call for gas system from 2022 staying on while it’s off, air filter is 20*25*1. Upon arrival customer stated that when the thermostat was off the system outside stayed running and the inside system was off. During my inspection I turned the system on and everything turned on but when I turned it off everything turned off except the condenser outside. When I took the door panel off I noticed the contactor was still activated. I checked to see if it was getting a signal and it wasn’t. I unwired the low voltage and it was still activated. After further investigation I found the contactor to be extremely burnt to the point where the contacts were welded shut. I showed the customer and asked if they’ve had any power surges or blackouts and he said all the time specially when it storms. I informed him that a power surge could’ve burnt this part up and that we could prevent it from happening again by adding a full system surge protection but for now he just wants to replace the cont
Anna, TX 75409
Matthew C.
Matthew C.
Preformed cooling maintenance on single system 2022. I tested all electrical components on the inside unit. All tested within manufacturer specifications range. Temp across the indoor coil was 18 degrees. Filter did not need to be changed at this time. I treated drain line with total c. I proceeded outside to check all electrical components on the outdoor unit and test the run and start amps of the compressor and fan motors. All tested within manufacturer specifications. The run amps for the compressor and fan are within manufacturer specifications range. The unit’s compressor start amps are above the manufacturer specifications range of 104 amps. The up I could benefit from having a hard start kit installed to assist the compressor on start up and potentially bring those amps down. I rinsed the outdoor coil. Unit was cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed cooling maintenance on single system 2022. I tested all electrical components on the inside unit. All tested within manufacturer specifications range. Temp across the indoor coil was 18 degrees. Filter did not need to be changed at this time. I treated drain line with total c. I proceeded outside to check all electrical components on the outdoor unit and test the run and start amps of the compressor and fan motors. All tested within manufacturer specifications. The run amps for the compressor and fan are within manufacturer specifications range. The unit’s compressor start amps are above the manufacturer specifications range of 104 amps. The up I could benefit from having a hard start kit installed to assist the compressor on start up and potentially bring those amps down. I rinsed the outdoor coil. Unit was cooling upon departure.
Anna, TX - Preformed cooling maintenance on single system 2022. I tested all electrical components on the inside unit. All tested within manufacturer specifications range. Temp across the indoor coil was 18 degrees. Filter did not need to be changed at this time. I treated drain line with total c. I proceeded outside to check all electrical components on the outdoor unit and test the run and start amps of the compressor and fan motors. All tested within manufacturer specifications. The run amps for the compressor and fan are within manufacturer specifications range. The unit’s compressor start amps are above the manufacturer specifications range of 104 amps. The up I could benefit from having a hard start kit installed to assist the compressor on start up and potentially bring those amps down. I rinsed the outdoor coil. Unit was cooling upon departure.
Shelby S.
Shelby S.
I performed a single system safety check on 2020 communicating heat pump. I checked amps, electrical, drains, and cleanliness. The system is cooling inside of manufacture specifications. I noticed the outdoor unit has build up in the coil. This causes poor air flow. The results are degraded efficiency and possible failure. The customer approved performing a drain treatment. With the customer not having a membership program, I offered to renew the customer. Customer declined membership and would like to wait to perform the cleaning.
Anna, TX 75409
Anna, TX - I performed a single system safety check on 2020 communicating heat pump. I checked amps, electrical, drains, and cleanliness. The system is cooling inside of manufacture specifications. I noticed the outdoor unit has build up in the coil. This causes poor air flow. The results are degraded efficiency and possible failure. The customer approved performing a drain treatment. With the customer not having a membership program, I offered to renew the customer. Customer declined membership and would like to wait to perform the cleaning.
Anna, TX - I performed a single system safety check on 2020 communicating heat pump. I checked amps, electrical, drains, and cleanliness. The system is cooling inside of manufacture specifications. I noticed the outdoor unit has build up in the coil. This causes poor air flow. The results are degraded efficiency and possible failure. The customer approved performing a drain treatment. With the customer not having a membership program, I offered to renew the customer. Customer declined membership and would like to wait to perform the cleaning.
Jacob P.
Jacob P.
I arrived to the unit not cooling the home properly. Upon arrival the tenants showed me the thermostat and location of the indoor equipment. They had shut the system off to avoid any damage. I turn the thermostat on and verified the indoor equipment was on and running. I then proceeded outside and diagnosed a failed capacitor. I also tested the contactor which had residual damage, most often caused by the slow failure of the capacitor. I called the landlord Al and I presented my findings, I offered to replace these parts as well as add a compressor saver to help protect the compressor motor. He elected to replace these parts failed/damaged components only today. Once replaced I further tested the unit to ensure it was cooling properly. Refrigerant pressures and the temperature drop measured within normal manufacture specifications today. The unit is cooling properly on departure. It should satisfy the thermostat set point in a few hours and the tenants are aware of this.
Anna, TX 75409
Anna, TX - I arrived to the unit not cooling the home properly. Upon arrival the tenants showed me the thermostat and location of the indoor equipment. They had shut the system off to avoid any damage. I turn the thermostat on and verified the indoor equipment was on and running. I then proceeded outside and diagnosed a failed capacitor. I also tested the contactor which had residual damage, most often caused by the slow failure of the capacitor. I called the landlord Al and I presented my findings, I offered to replace these parts as well as add a compressor saver to help protect the compressor motor. He elected to replace these parts failed/damaged components only today. Once replaced I further tested the unit to ensure it was cooling properly. Refrigerant pressures and the temperature drop measured within normal manufacture specifications today. The unit is cooling properly on departure. It should satisfy the thermostat set point in a few hours and the tenants are aware of this.
Anna, TX - I arrived to the unit not cooling the home properly. Upon arrival the tenants showed me the thermostat and location of the indoor equipment. They had shut the system off to avoid any damage. I turn the thermostat on and verified the indoor equipment was on and running. I then proceeded outside and diagnosed a failed capacitor. I also tested the contactor which had residual damage, most often caused by the slow failure of the capacitor. I called the landlord Al and I presented my findings, I offered to replace these parts as well as add a compressor saver to help protect the compressor motor. He elected to replace these parts failed/damaged components only today. Once replaced I further tested the unit to ensure it was cooling properly. Refrigerant pressures and the temperature drop measured within normal manufacture specifications today. The unit is cooling properly on departure. It should satisfy the thermostat set point in a few hours and the tenants are aware of this.
Jacob P.
Jacob P.
I arrived at the venue to discuss potential solutions to the conditioning and humidity issues present in the space. Our clients elected voiced his concerns regarding the effectiveness of the mini split units and their ability to keep up when the venue is occupied and guests are actively using the space. We discussed the potential to add a package unit with ductwork on the exterior of the building for return and supply with a horizontal T split for the indoor supply air. I will come up with an estimate for a package unit installation and ductwork as well as a WiFi enabled thermostat that can control the equipment.
Anna, TX 75409
Anna, TX - I arrived at the venue to discuss potential solutions to the conditioning and humidity issues present in the space. Our clients elected voiced his concerns regarding the effectiveness of the mini split units and their ability to keep up when the venue is occupied and guests are actively using the space.
We discussed the potential to add a package unit with ductwork on the exterior of the building for return and supply with a horizontal T split for the indoor supply air. I will come up with an estimate for a package unit installation and ductwork as well as a WiFi enabled thermostat that can control the equipment.
Anna, TX - I arrived at the venue to discuss potential solutions to the conditioning and humidity issues present in the space. Our clients elected voiced his concerns regarding the effectiveness of the mini split units and their ability to keep up when the venue is occupied and guests are actively using the space.
We discussed the potential to add a package unit with ductwork on the exterior of the building for return and supply with a horizontal T split for the indoor supply air. I will come up with an estimate for a package unit installation and ductwork as well as a WiFi enabled thermostat that can control the equipment.
Matthew C.
Matthew C.
Preformed single system maintenance. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Temp across the coil was 20 degrees, 75 coming into the unit and 55 degrees coming out of the supply. I treated drain line with total c and replace the clients filter. I proceeded outside to test all electrical components along with run and start amps for the compressor and fan motors. All electrical tested with manufacturer specifications. The start amps for the compressor were testing outside of manufacturer specifications range with high . Initial started up amps should be below 124 amps. I rinsed outdoor unit. I also provided estimates for a hard start kit to help bring the start amps for the compressor down. Unit was cooling upon departure.
Anna, TX 75409
Anna, TX - Preformed single system maintenance. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Temp across the coil was 20 degrees, 75 coming into the unit and 55 degrees coming out of the supply. I treated drain line with total c and replace the clients filter. I proceeded outside to test all electrical components along with run and start amps for the compressor and fan motors. All electrical tested with manufacturer specifications. The start amps for the compressor were testing outside of manufacturer specifications range with high . Initial started up amps should be below 124 amps. I rinsed outdoor unit. I also provided estimates for a hard start kit to help bring the start amps for the compressor down. Unit was cooling upon departure.
Anna, TX - Preformed single system maintenance. I tested all electrical components on the inside unit. All tested within manufacturer specifications. Temp across the coil was 20 degrees, 75 coming into the unit and 55 degrees coming out of the supply. I treated drain line with total c and replace the clients filter. I proceeded outside to test all electrical components along with run and start amps for the compressor and fan motors. All electrical tested with manufacturer specifications. The start amps for the compressor were testing outside of manufacturer specifications range with high . Initial started up amps should be below 124 amps. I rinsed outdoor unit. I also provided estimates for a hard start kit to help bring the start amps for the compressor down. Unit was cooling upon departure.
Jacob P.
Jacob P.
Arrived at our clients home to the downstairs until not cooling properly. I proceeded to the thermostat and ensured it was on. I could hear the indoor unit blower motor on and running but no cool air was being supplied into the downstairs space. I proceeded to the outdoor equipment and immediately diagnosed a failed capacitor. I proceeded to test the other electrical components. Our clients elected to replace the capacitor today. Once replaced I also ensured the refrigerant pressures were within manufacture specifications. The unit in cooling properly on departure.
Anna, TX 75409
Anna, TX - Arrived at our clients home to the downstairs until not cooling properly. I proceeded to the thermostat and ensured it was on. I could hear the indoor unit blower motor on and running but no cool air was being supplied into the downstairs space.
I proceeded to the outdoor equipment and immediately diagnosed a failed capacitor. I proceeded to test the other electrical components. Our clients elected to replace the capacitor today. Once replaced I also ensured the refrigerant pressures were within manufacture specifications. The unit in cooling properly on departure.
Anna, TX - Arrived at our clients home to the downstairs until not cooling properly. I proceeded to the thermostat and ensured it was on. I could hear the indoor unit blower motor on and running but no cool air was being supplied into the downstairs space.
I proceeded to the outdoor equipment and immediately diagnosed a failed capacitor. I proceeded to test the other electrical components. Our clients elected to replace the capacitor today. Once replaced I also ensured the refrigerant pressures were within manufacture specifications. The unit in cooling properly on departure.
Shelby S.
Shelby S.
I performed a 2 system maintenance on two 2016 gas furnaces. I checked amps, capacitors, filters, drains, safeties, and cleanliness. I found that the systems are cooling to the best of their abilities. I did find that the outdoor units could use some replacement electrical parts. I noticed that both units are starting close to their maximum electrical load. I noticed that the upstairs units is in need of a capacitor and a new contactor. The capacitor is reading right at the bare minimum of the manufacturer specification. The typical ohm range of a contactor is 10-20. It is currently ohming at 20. I provided pricing to address these noticed issues. Spoke about possible blower cleaning in the fall for the upstairs system.
Anna, TX 75409
Anna, TX - I performed a 2 system maintenance on two 2016 gas furnaces. I checked amps, capacitors, filters, drains, safeties, and cleanliness. I found that the systems are cooling to the best of their abilities. I did find that the outdoor units could use some replacement electrical parts. I noticed that both units are starting close to their maximum electrical load. I noticed that the upstairs units is in need of a capacitor and a new contactor. The capacitor is reading right at the bare minimum of the manufacturer specification. The typical ohm range of a contactor is 10-20. It is currently ohming at 20. I provided pricing to address these noticed issues. Spoke about possible blower cleaning in the fall for the upstairs system.
Anna, TX - I performed a 2 system maintenance on two 2016 gas furnaces. I checked amps, capacitors, filters, drains, safeties, and cleanliness. I found that the systems are cooling to the best of their abilities. I did find that the outdoor units could use some replacement electrical parts. I noticed that both units are starting close to their maximum electrical load. I noticed that the upstairs units is in need of a capacitor and a new contactor. The capacitor is reading right at the bare minimum of the manufacturer specification. The typical ohm range of a contactor is 10-20. It is currently ohming at 20. I provided pricing to address these noticed issues. Spoke about possible blower cleaning in the fall for the upstairs system.

Your High Efficiency

Experts