Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in July 2025.
The most recent job was on July 8, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
Maximum amount of refrigerant for the system. I do not expect that we will need the full amount, as the system is still cooling. However we will not know for sure how much refrigerant we will need until we actually add the refrigerant.
- Homeowner complaint is that her thermostat isn’t working properly. Found that the thermostat did not respond accurately to touch and homeowner was unable to connect thermostat to Wi-Fi or control her system through her Trane home app. - Homeowner stated that her power went out earlier in the day. - When the HVAC system and the Internet provider router lose power. The thermostat will go into a reboot mode which requires recalibration to the touchscreen. User needs to be right in front of the thermostat when it reboots and prompts user to recalibrate the touchscreen because it only gives about five seconds to recalibrate the screen before initializing and returning to home screen. - Accessed settings of the thermostat and manually rebooted thermostat to prompt for recalibration to the screen. - After calibration of the screen, system responded to touch accurately. - Assisted homeowner in setting up her network/Wi-Fi connection to thermostat and re-linked thermostat back with Trane ho
I arrived to address items flagged by a home inspection report. The report stated that the unit had air leakage from the indoor attic AirHandler to the connecting supply plenum box. I identified where the “leaks” were located and used mastic seal to seal them. They were superficial and not actually leaking air but rather exposed a portion of the metal air handler cabinet. I also used foil tape to cover the temperature probe hole used to measure supply temperature for the unit. The existing duct work is hung as properly as it can be given the limited attic space and existing ductwork design. The large 16” return duct is only touching a rafter it is not resting on attic insulation. This will jot cause or contribute to deterioration of the flex ductwork. I did also brush away the none resistant debris that had fallen into the drain pan, since it was also tagged on the inspection report but is not restricting in any way. The system is running properly on departure.
15 SEER complete heat pump replacement. Once new equipment was installed we tested it and ran the unit to ensure it was cooling properly. We went into the attic and discussed the new equipment and the upgrades completed on the duct work. We set up the thermostat to Wi-Fi and ensured it was connected to the homeowners app. I showed him the different operating modes and answer questions regarding the new equipment and maintenance. The unit is cooling with a perfect 20° drop on departure.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Cap was testing a little low but within range. Customer replaced 1 1/2 years ago. Advised we will keep an eye on it in the future.
Upon arrival customer stated that they noticed rust and condensation on the air handler. Upon inspection we noticed the blower wheel to be dirty along with the evaporator coil. Evaporator coil does show signs of rust and possible deterioration. Main drain line has no insulation and float switch. We proceeded outside we tested the pressures on the unit. Pressures indicated a possible leak, 14 degree temp drop across the evaporator coil. We preformed a courtesy leak detection for customer. We noticed the Contactor was testing on the high side at 18ohms but still within manufacturer specifications. Start amps tested over manufacturer specifications for the compressor. We are recommending a hard start kit and new Contactor. The customer did say the capacitor was about a year old. Offered estimates for new Contactor, hard start kit, evaporator coil clean(no rinse),a pull and clean of the blower wheel and system is about 3lbs low on refrigerant. Unit was cooling upon departure. Dispatch fee
I arrived at our clients home to inspect the system. The unit was not cooling properly for the last few days. They visually inspected the unit yesterday and found the indoor coil to be completely frozen over. They had shut the unit off and allowed it to thaw out. I inspected the entire system and could visually see the oil spot in the indoor evaporator coil. I presented my finding to our client and we discussed how the older indoor air handler was out of warranty and the coil not be replaced due to the R410a refrigerant being phased out. We discussed replacement options and our client wanted to proceed with the band aid option first. I charged the unit up with 4 lbs of refrigerant and let the unit run for 20/30 minutes. The charged was lost almost immediately. I explained that the leak seal and Freon would not last the weekend and the ice could have potentially damaged the coil further making a small leak larger. He elected to move forward with the replacement option and we will r
Upon arrival, I found the drain line clogged at the p trap. I used a panduit strap to test if it was in the p trap. The drain could still really use some nitrogen to purge the drain to ensure it is clear. We will have to wait for confirmation to proceed with repairs. We could not get in contact with Mr. Ponder. System is drain for now.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Found minor refrigerant leak at suction schrader valve. I was able to tighten the valve and was no longer getting hits on my electronic leak detector or bubble leak detector. Tested pressures and they were testing within range. No further
I arrived to the unit not cooling properly. The unit was shut off at the thermostat. I turned it on and nothing happened. I began my diagnosis at the indoor furnace unit where I found a tripped reset fuse. I reset the fuse and the unit turned on. I still proceeded to test and inspect the entire system to identify why the fuse was tripped. I did not find anything. That had “failed”. What I did find was a number of components that excessive wear and tear. The capacitors for the compressor motor and the fan motors are testing below manufacture specifications. This is subsequently adding to excessive high start amps to the compressor motor. The contactor, which acts like a switch for the outdoor equipment, is charred with evidence of arching. This single component is directly correlated with the blown fuse and may have triggered it to trip due to the excessive pull of power. The underlying reason the system is working so hard is because it is low on the old R-22 refrigerant. Our clients