Adon Complete Air Conditioning and Heating is Anna’s local HVAC company. Most contractors serving this area are driving in from McKinney or further south. We’re not. Our office is right here in Anna. Our owner, Jesse Villarreal, has been serving Collin County homeowners for over 27 years, and our technicians run calls in Anna neighborhoods every single day. Whether you’re in an established neighborhood near downtown, a newer community like Liberty Hills, or getting ready to move into Sherley Farms, we know this city and we’re ready to help.
HVAC Services in Anna, TX
Anna is one of the fastest-growing cities in North Texas, and with thousands of new homes coming online, the demand for reliable heating and cooling service has never been higher. Here’s what we offer Anna homeowners:
AC Repair. Fast diagnosis and repair on all makes and models. We’re already in Anna every day, which means getting to you quickly isn’t a problem.
AC Installation. Whether you’re moving into a new build or replacing an aging system, we size every installation correctly using a proper load calculation. All new installations come with up to a 10-year labor warranty.
HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Anna homeowners in new construction, getting on a maintenance plan early is one of the best ways to protect your warranty and catch issues before they become expensive.
Mini-Split Installation. Ductless systems work especially well for garages, home offices, bonus rooms, and additions, all of which are common in Anna’s newer construction neighborhoods.
Heat Pump Installation and Repair. Heat pumps provide year-round heating and cooling from one system. A popular option for Anna’s newer builds where energy efficiency matters.
Indoor Air Quality. New construction homes are built tight for energy efficiency, which means less fresh air circulation. Air filtration systems, UV purifiers, and ventilators help keep the air inside your home clean and healthy. We offer a free “What Are You Breathing?” screening to Anna homeowners.
Air Duct Cleaning. Construction dust and debris in ductwork is a real issue in new builds. Professional duct cleaning after move-in is something we recommend for most Anna homeowners in newer communities.
Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Anna and Collin County.
HVAC Services for Anna’s Growing Neighborhoods
Anna’s population grew roughly 177 percent between 2022 and 2023, making it one of the fastest-growing cities in the country. Sherley Farms, a $1.5 billion master-planned community, broke ground in March 2026 and will bring roughly 3,000 new homes to the city over the next several years. Liberty Hills is adding another 1,800 homes near US-75. That’s thousands of new HVAC systems coming online in a city that’s already one of our busiest service areas.
For homeowners in newer construction, the first few years matter most. Builder-installed systems need to be maintained on schedule to keep warranties valid, and new ductwork should be inspected and cleaned after construction is complete. We’ve helped Anna homeowners navigate all of this, and we know exactly what to look for.
Why Anna Homeowners Choose Adon Complete
- We live here. Our office is at 824 S Central Expressway in Anna. When you call us, you’re calling your neighbor, not a company routing calls from a regional office in Dallas.
- Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in every aspect of the business. That level of accountability is hard to find at a larger company.
- We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained installation and the full manufacturer’s warranty on every system we install.
- We service everything. Whatever brand is in your home, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
- The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access.
Frequently Asked Questions
Here are some answers to common questions we get about our Anna HVAC services.
How much does AC repair cost in Anna, TX?
Most AC repairs in Anna run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement are on the lower end. More involved repairs, like a blower motor or evaporator coil, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in Anna?
Yes. We offer 24/7 emergency heating and air conditioning service throughout Anna and Collin County. Since we’re based in Anna, response times are typically faster here than anywhere else we serve.
What HVAC brands do you service in Anna?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise in those brands.
Do you offer HVAC maintenance plans in Anna?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. For new construction homeowners especially, staying on a maintenance schedule helps protect your builder warranty.
What areas near Anna do you serve?
We serve all of Anna and the surrounding Collin County communities, including McKinney, Sherman, Melissa, Van Alstyne, and Allen.
Schedule HVAC Service in Anna Today
We’re already in your neighborhood. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in Anna, TX
Anna, TX at a glance
Adon Complete Air Conditioning and Heating has completed 10 jobs in Anna, TX in May 2025.
The most recent job was on May 30, 2025.
Adon Complete Air Conditioning and Heating has completed 589 jobs in Anna, TX in the last 12 months. The first job there was in February 2020.
Job Locations
I found that the indoor heat was working as intended but is in need of cleaning. The outdoor control board does not have any LEDs present, and I confirmed that the board is receiving power. I dismounted the board and found that a spider shorted out the control board. It needs to be replaced before further testing can happen. I informed the customer that the unit could have further issues once the board is replaced. The customer did not approve any repairs at this time.
Replaced zone board. System powered up without error. Tested to make sure dampers are functioning properly. Everything working as intended.
Preformed cooling maintenance. Upon arrival the customer did state that their daughter’s room was not getting cool enough. Check dampers to insure appropriate air flow was being distributed to the room. We adjusted a damper to the bathroom to allow more air flow into the daughter’s bed room. We checked all electrical components outside. All tested within manufacturer specification although system could benefit from having a hard start kit installed. Noticed the client does not have a blow out valve on his main drain line, provided estimates for both a hard start kit and blow out valve. Client wants to talk about the estimates with his wife. Client did not have e replacement filters for us to change. Cooling system is in working order upon departure.
Replaced air handler control board. Unit was still having issues. Rewired thermostat directly to equipment bypassing zone board. Unit operating normally. Will need to order new zone board and replace.
Found upstairs system low on R410a. I found the leak in the evaporator coil. The unit has warranty until 12/28/26. I provided options to deal with the issue. I added 3 pounds of R410a and informed the customer that there is not warranty on the refrigerant. From signs I seen after adding refrigerant, I believe the TXV is having an issue as well. The unit would not build liquid pressure. System is cooling with right at a 19 temperature drop.
Returned to home to install air scrubber unit in attic supply AirHandler. Once connected and installed we tested to ensure proper operation. Showed our client pictures of the unit and discussed that replacing the cell once every 3 years. Unit is running properly on departure.
Upon arrival, I found that the upstairs unit was low on R410a. This was determined by a temperature split resulting in 13 degrees. I proceeded outside and hooked up my gauges to confirm. I spoke with the homeowner about various options. The customer approved adding u/v leak seal, topping the unit off, and a membership. I informed the customer that the refrigerant and leak seal does not have any warranty and the potential of voiding his manufacture warranty. Customer stated it was registered so it would have approximately 1 year of warranty left. The system is cooling with a 17 degree temperature split now and customer declined adding more refrigerant.
Blower motor not running after storm. Tested 240 coming into motor. 3-4 volts on motor speed settings. EE5 error on control board Checked fuses. 13.5 volts to ground on both sides of float switch. Tech support indicates that this is a sign of a faulty board.
Homeowner stated that the unit ( 2 zoned unit), is not cooling,, Started diagnostic at the outdoor unit after setting thermostat to cool, noticed we didn’t have 27 volts coming to the condenser unit, found one of the breakers from the air handler on off position, set it to on,, outdoor unit was displaying a code (5 flashes), soft lockout,, turned power off, turned back on , we had a 3 flashes code ( low pressure switch open), checked refrigerant pressures, unit had 0.00 psig on both lines, added some refrigerant ( up to 40 psig),inspected outdoor/ indoor unit for some signs of refrigerant leak , we even run an electronic leak search ( very easy access), but couldn’t pointed out,, we highly believe the leak is at the evaporator coil and needs to be replaced as soon as possible. Unit is from 2022, our install,,, will send estimates for repair.
I replaced the shorted contactor and tested the system. I could not get it to replicate the high pressure switch lock out. The system does not have a high pressure switch. The capacitor is becoming weak on the fan side 8.5/10. I have 80 degree return air and 60 degree supply air. I informed the customer to allow for a couple of hours of run time to make it comfortable again. I still suspect the defrost board is trying to short out, but I could not confirm it at the time of service.