Menu

HVAC Service in Frisco, TX

Frisco has grown faster than almost any city in America over the past two decades, and the homes here reflect it. Larger floor plans, multi-zone systems, high-efficiency equipment, and newer construction in neighborhoods like The Fields, Phillips Creek Ranch, and Viridian. Keeping all of it running well takes an HVAC company that knows what it’s doing. Adon Complete Air Conditioning and Heating has been running calls for HVAC service in Frisco for years from our home base in Anna, just up the Dallas North Tollway corridor. We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in FriscoCall (903) 482-4900

What We Do for Frisco Homeowners

AC Repair. We diagnose and repair all makes and models. Frisco’s newer construction often means multi-zone systems and communicating equipment — our technicians know how to work on all of it.

AC Installation. When it’s time to replace, we size every system correctly using a proper load calculation. That matters especially in Frisco’s larger homes where an improperly sized system will short-cycle and leave rooms uncomfortable. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Frisco homeowners with high-end systems, staying on a maintenance schedule is one of the best ways to protect your investment.

Mini-Split Installation. Garages, home offices, casitas, and bonus spaces are common in Frisco’s larger homes. Mini-splits handle these spaces cleanly without touching your central system.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from one system and work well in North Texas’s climate. A practical choice for Frisco homeowners upgrading to a more efficient setup.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening. Frisco’s tight construction means less natural ventilation, making air quality systems more important than in older homes.

Air Duct Cleaning. Even newer ductwork accumulates contaminants over time. Professional duct cleaning improves air quality and keeps your system running efficiently throughout the home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. In a larger Frisco home, that adds up fast. We inspect, repair, and seal ductwork throughout the area.

Why Frisco Homeowners Choose Adon Complete

Frisco has no shortage of HVAC companies competing for business. Here’s why our customers keep calling us back.

We know multi-zone and communicating systems. The job notes from our Frisco calls show what we actually work on here – damper adjustments, multi-system diagnostics, communicating Trane equipment, humidity management in two-story homes. This isn’t routine work, and we handle it well.

Jesse Villarreal has over 27 years of experience. He’s the owner and is directly involved in how the business operates. When something goes wrong, you’re dealing with a company where the owner’s reputation is on the line.

We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained on the brands most common in Frisco’s newer construction. Full manufacturer warranty on every system we install.

The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. Straightforward and affordable.

Serving Frisco and Surrounding Collin County Communities

We serve all of Frisco, including The Fields, Phillips Creek Ranch, Viridian, Stonebriar, and the established neighborhoods along Preston Road and the Dallas North Tollway. We also serve the surrounding communities of Allen, McKinney, Anna, Melissa, and Sherman.

Schedule HVAC Service in FriscoCall (903) 482-4900

Frequently Asked Questions

Here are some common questions we get about our HVAC services in Frisco.

How much does AC repair cost in Frisco, TX?

Most AC repairs in Frisco run between $150 and $600 depending on the type of repair. Frisco’s newer homes often have multi-zone systems and higher-end equipment, which can affect parts costs. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you service multi-zone systems in Frisco?

Yes. Multi-zone systems and communicating HVAC equipment are common in Frisco’s larger homes, and our technicians work on them regularly. We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, and more.

Do you offer HVAC maintenance plans in Frisco?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. Preventive maintenance is especially important for the multi-system setups common in Frisco’s larger homes.

Do you offer emergency HVAC service in Frisco?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Frisco. When you call after hours, you reach a real person who can get a technician to your home fast.

What areas near Frisco do you serve?

We serve all of Frisco and the surrounding communities including Allen, McKinney, Anna, Melissa, and Sherman.

Ready to Get Your System Serviced?

Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online for HVAC services in Frisco. We handle everything from routine maintenance to emergency repairs throughout Frisco and Collin County.

Schedule HVAC Service in FriscoCall (903) 482-4900

Recent Jobs and Reviews in Frisco, TX

Rated 5.0 out of 5 stars based on 7 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Frisco, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Frisco, TX between December 2025 and February 2026.

The most recent job was on February 20, 2026.

Adon Complete Air Conditioning and Heating has completed 51 jobs in Frisco, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Shelby S.
Shelby S.
Upon arrival, I spoke with the homeowner about what he was looking for out of today’s second opinion visit. He spoke about issues that another company informed him out. I began investigating the customer concerns. There are a reasonable amount of issues I seen with these systems. There are cases of the indoor coil being a different size than the outdoor unit. One of the furnaces is from 1997. The older furnaces has a design flaw that will not allow someone to safely replace the blower motor. The inducer motor is not performing as smoothly as it use to. There is wiring outside that is compromised. All of the electrical components outside are worn. Customer mentioned insulation for the areas that he has access to. Customer would like pricing on new equipment to be sent over. According to outdoor data tags the equipment is: Downstairs - 4 ton(2010) Master Bedroom - 2 ton (1997 furnace 2013 outdoor) and Upstairs 3ton (2015). All of the equipment is gas.
Frisco, TX 75034
Frisco, TX - Upon arrival, I spoke with the homeowner about what he was looking for out of today’s second opinion visit. He spoke about issues that another company informed him out. I began investigating the customer concerns. There are a reasonable amount of issues I seen with these systems. There are cases of the indoor coil being a different size than the outdoor unit. One of the furnaces is from 1997. The older furnaces has a design flaw that will not allow someone to safely replace the blower motor. The inducer motor is not performing as smoothly as it use to. There is wiring outside that is compromised. All of the electrical components outside are worn. Customer mentioned insulation for the areas that he has access to. Customer would like pricing on new equipment to be sent over. According to outdoor data tags the equipment is: Downstairs - 4 ton(2010) Master Bedroom - 2 ton (1997 furnace 2013 outdoor) and Upstairs 3ton (2015). All of the equipment is gas.
Frisco, TX - Upon arrival, I spoke with the homeowner about what he was looking for out of today’s second opinion visit. He spoke about issues that another company informed him out. I began investigating the customer concerns. There are a reasonable amount of issues I seen with these systems. There are cases of the indoor coil being a different size than the outdoor unit. One of the furnaces is from 1997. The older furnaces has a design flaw that will not allow someone to safely replace the blower motor. The inducer motor is not performing as smoothly as it use to. There is wiring outside that is compromised. All of the electrical components outside are worn. Customer mentioned insulation for the areas that he has access to. Customer would like pricing on new equipment to be sent over. According to outdoor data tags the equipment is: Downstairs - 4 ton(2010) Master Bedroom - 2 ton (1997 furnace 2013 outdoor) and Upstairs 3ton (2015). All of the equipment is gas.
Brayden W.
Brayden W.
Condensate Drain Pump Installation Replacement on Mini Split Scope of Work -Order and pick up part from the supplier - Install condensate drain pump on indoor unit mini split head - Route discharge tubing to the approved drain location - Connect the pump to the power source and integrate with the system safety controls - Test pump operation and verify proper drainage - Estimated labor time 2.30 hours, including procurement of part Materials & Equipment - Condensate drain pump compatible with Mitsubishi system - Drain tubing and fittings - Electrical wiring and connection supplies Special Notes - A pump is required when gravity drainage is not achievable - Proper installation helps prevent water overflow and potential water damage Warranty: 90 days after initial installation Taxes, shipping, and handling are included Proper maintenance every 3/6 months is recommended for mini-split units.
Frisco, TX 75034
Frisco, TX - Condensate Drain Pump Installation Replacement on Mini Split 


Scope of Work
-Order and pick up part from the supplier 
- Install condensate drain pump on indoor unit mini split head 
- Route discharge tubing to the approved drain location
- Connect the pump to the power source and integrate with the system safety controls
- Test pump operation and verify proper drainage
- Estimated labor time 2.30 hours, including procurement of part 

Materials & Equipment
- Condensate drain pump compatible with Mitsubishi system
- Drain tubing and fittings
- Electrical wiring and connection supplies

Special Notes
- A pump is required when gravity drainage is not achievable
- Proper installation helps prevent water overflow and potential water damage

Warranty: 90 days after initial installation

Taxes, shipping, and handling are included

Proper maintenance every 3/6 months is recommended for mini-split units.
Frisco, TX - Condensate Drain Pump Installation Replacement on Mini Split 


Scope of Work
-Order and pick up part from the supplier 
- Install condensate drain pump on indoor unit mini split head 
- Route discharge tubing to the approved drain location
- Connect the pump to the power source and integrate with the system safety controls
- Test pump operation and verify proper drainage
- Estimated labor time 2.30 hours, including procurement of part 

Materials & Equipment
- Condensate drain pump compatible with Mitsubishi system
- Drain tubing and fittings
- Electrical wiring and connection supplies

Special Notes
- A pump is required when gravity drainage is not achievable
- Proper installation helps prevent water overflow and potential water damage

Warranty: 90 days after initial installation

Taxes, shipping, and handling are included

Proper maintenance every 3/6 months is recommended for mini-split units.
Brayden W.
Brayden W.
Arrived on site for leaking mini split and found water coming from Sean
Frisco, TX 75034
Frisco, TX - Arrived on site for leaking mini split and found water coming from Sean
Frisco, TX - Arrived on site for leaking mini split and found water coming from Sean
Brayden W.
Brayden W.
Perform maintenance on 2017 electric heat air handler. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Inspected / replaced return filter. 7. Inspected return plenum for debris/ dirty. 8. Inspected evaporator coil. 9. Inspected blower motor/ blower wheel. 10. Checked blower amp draw. 11. Measured temperature differential from supply to return. 20 degrees measured. 12. Tested capacitor and contactor (outdoor electrical) 13. Rinsed condenser unit to promote heat exchange 14. Tested electric heat and found no issues Upon inspection of the unit I found signs of extremely high static pressure. A plug on the front of the unit had been pulled into the evaporator coil , and customer stated he could hear whistling while the unit was running. Upon reviewing the ductwork, I only found one 18” duct. This only allows for 130
Frisco, TX 75035
Frisco, TX - Perform maintenance on 2017 electric heat air handler.

1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Inspected / replaced return filter.
7. Inspected return plenum for debris/ dirty.
8. Inspected evaporator coil.
9. Inspected blower motor/ blower wheel.
10. Checked blower amp draw.
11. Measured temperature differential from supply to return. 20 degrees measured.
12. Tested capacitor and contactor (outdoor electrical)
13. Rinsed condenser unit to promote heat exchange
14. Tested electric heat and found no issues

Upon inspection of the unit I found signs of extremely high static pressure. A plug on the front of the unit had been pulled into the evaporator coil , and customer stated he could hear whistling while the unit was running. Upon reviewing the ductwork, I only found one 18” duct. This only allows for 130
Frisco, TX - Perform maintenance on 2017 electric heat air handler.

1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Inspected / replaced return filter.
7. Inspected return plenum for debris/ dirty.
8. Inspected evaporator coil.
9. Inspected blower motor/ blower wheel.
10. Checked blower amp draw.
11. Measured temperature differential from supply to return. 20 degrees measured.
12. Tested capacitor and contactor (outdoor electrical)
13. Rinsed condenser unit to promote heat exchange
14. Tested electric heat and found no issues

Upon inspection of the unit I found signs of extremely high static pressure. A plug on the front of the unit had been pulled into the evaporator coil , and customer stated he could hear whistling while the unit was running. Upon reviewing the ductwork, I only found one 18” duct. This only allows for 130
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues 17. Tested for gas leaks 18. Tested functionality and cleaned flame sensor 19. Tested functionality and cleaned pressure switches and ports 20. Tested igniters No issues at this time all is running well with system. Noticed there was no surge protection on any of the units. Search pr
Frisco, TX 75035
Frisco, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues
17. Tested for gas leaks
18. Tested functionality and cleaned flame sensor
19. Tested functionality and cleaned pressure switches and ports
20. Tested igniters

No issues at this time all is running well with system. Noticed there was no surge protection on any of the units. Search pr
Frisco, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues
17. Tested for gas leaks
18. Tested functionality and cleaned flame sensor
19. Tested functionality and cleaned pressure switches and ports
20. Tested igniters

No issues at this time all is running well with system. Noticed there was no surge protection on any of the units. Search pr
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Inspected / replaced return filters 7. Inspected return plenum for debris/ dirty. 8. Inspected evaporator coil. 9. Inspected blower motor/ blower wheel. 10. Checked blower amp draw. 11. Measured temperature differential from supply to return. 20 degrees measured. 12. Tested capacitor and contactor 13. Tested electric heat and found no issues Noticed decent amount of dust and debris on condenser coil. Recommend chemical wash to improve efficiency in cooling. Unit in good working order upon departure.
Frisco, TX 75034
Frisco, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Inspected / replaced return filters
7. Inspected return plenum for debris/ dirty.
8. Inspected evaporator coil.
9. Inspected blower motor/ blower wheel.
10. Checked blower amp draw.
11. Measured temperature differential from supply to return. 20 degrees measured.
12. Tested capacitor and contactor
13. Tested electric heat and found no issues

Noticed decent amount of dust and debris on condenser coil. Recommend chemical wash to improve efficiency in cooling. Unit in good working order upon departure.
Frisco, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Inspected / replaced return filters
7. Inspected return plenum for debris/ dirty.
8. Inspected evaporator coil.
9. Inspected blower motor/ blower wheel.
10. Checked blower amp draw.
11. Measured temperature differential from supply to return. 20 degrees measured.
12. Tested capacitor and contactor
13. Tested electric heat and found no issues

Noticed decent amount of dust and debris on condenser coil. Recommend chemical wash to improve efficiency in cooling. Unit in good working order upon departure.
Shelby S.
Shelby S.
I found that the motor is in the early stages of failure. This is likely due to its increase usage. The system is zoned, and the fresh air will operate when either zone is active. The suggested route to repair is replacement of the fresh air unit.
Frisco, TX 75035
Frisco, TX - I found that the motor is in the early stages of failure. This is likely due to its increase usage. The system is zoned, and the fresh air will operate when either zone is active. The suggested route to repair is replacement of the fresh air unit.
Frisco, TX - I found that the motor is in the early stages of failure. This is likely due to its increase usage. The system is zoned, and the fresh air will operate when either zone is active. The suggested route to repair is replacement of the fresh air unit.
Matthew C.
Matthew C.
Demand call/heat preventative maintenance on two gas systems from 2011 using air filter 20*25*1 which customer did provide today to change. Demand call was for the upstairs system not cooling and having water drip out the emergency line over the garage. Upon a visual inspection the system had an “E312” error code indicating that there was lack of airflow. I checked the air filter and found it to be caked and not allowing proper airflow through the machine causing it to start building frost which led to an excessive amount of water going into the drain pan which drains outside. I took the air filter out and the machine sounded like a drowning victim, the error code cleared after a few seconds. I put the system in ac mode and let it run for 15-20 minutes, the system didnt produce an excessive amount of water because it wasn’t freezing up and I was getting 53 degrees coming out of the vents. On the maintenance I checked electrical connections and components, cleaned safety sensors, i
Frisco, TX 75036
Frisco, TX - Demand call/heat preventative maintenance on two gas systems from 2011 using air filter 20*25*1 which customer did provide today to change. 

Demand call was for the upstairs system not cooling and having water drip out the emergency line over the garage. Upon a visual inspection the system had an “E312” error code indicating that there was lack of airflow. I checked the air filter and found it to be caked and not allowing proper airflow through the machine causing it to start building frost which led to an excessive amount of water going into the drain pan which drains outside. 
I took the air filter out and the machine sounded like a drowning victim, the error code cleared after a few seconds. I put the system in ac mode and let it run for 15-20 minutes, the system didnt produce an excessive amount of water because it wasn’t freezing up and I was getting 53 degrees coming out of the vents. 

On the maintenance I checked electrical connections and components, cleaned safety sensors, i
Frisco, TX - Demand call/heat preventative maintenance on two gas systems from 2011 using air filter 20*25*1 which customer did provide today to change. 

Demand call was for the upstairs system not cooling and having water drip out the emergency line over the garage. Upon a visual inspection the system had an “E312” error code indicating that there was lack of airflow. I checked the air filter and found it to be caked and not allowing proper airflow through the machine causing it to start building frost which led to an excessive amount of water going into the drain pan which drains outside. 
I took the air filter out and the machine sounded like a drowning victim, the error code cleared after a few seconds. I put the system in ac mode and let it run for 15-20 minutes, the system didnt produce an excessive amount of water because it wasn’t freezing up and I was getting 53 degrees coming out of the vents. 

On the maintenance I checked electrical connections and components, cleaned safety sensors, i
Shelby S.
Shelby S.
Client is interested in upgrading thermostats, filtration, and air quality. I informed him that we will need some time to properly price the dehumidifier for the downstairs system. I provided pricing for 824 thermostats. These would go best with the equipment that is in the home. I provided pricing for T6 pros, surge protection, filter upgrades, and maintenance.
Frisco, TX 75035
Frisco, TX - Client is interested in upgrading thermostats, filtration, and air quality. I informed him that we will need some time to properly price the dehumidifier for the downstairs system. I provided pricing for 824 thermostats. These would go best with the equipment that is in the home. I provided pricing for T6 pros, surge protection, filter upgrades, and maintenance.
Frisco, TX - Client is interested in upgrading thermostats, filtration, and air quality. I informed him that we will need some time to properly price the dehumidifier for the downstairs system. I provided pricing for 824 thermostats. These would go best with the equipment that is in the home. I provided pricing for T6 pros, surge protection, filter upgrades, and maintenance.
Brayden W.
Brayden W.
Arrived on site for dryer vent cleaning and heating maintenance. Homeowner stated all was well with regards normal unit operation to his knowledge proceeded with heating maintenance as scheduled. 1.;Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Observed both blower wheels had a large amount of dust on them. This creates drag on the motor, causing it to work harder and ultimately shortening the lifespan. I would recommend cleaning both blower wheels
Frisco, TX 75036
Frisco, TX - Arrived on site for dryer vent cleaning and heating maintenance. Homeowner stated all was well with regards normal unit operation to his knowledge proceeded with heating maintenance as scheduled.

1.;Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.

Observed both blower wheels had a large amount of dust on them. This creates drag on the motor, causing it to work harder and ultimately shortening the lifespan. I would recommend cleaning both blower wheels
Frisco, TX - Arrived on site for dryer vent cleaning and heating maintenance. Homeowner stated all was well with regards normal unit operation to his knowledge proceeded with heating maintenance as scheduled.

1.;Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.

Observed both blower wheels had a large amount of dust on them. This creates drag on the motor, causing it to work harder and ultimately shortening the lifespan. I would recommend cleaning both blower wheels

Your High Efficiency

Experts