HVAC Service in Frisco, TX

Frisco has grown faster than almost any city in America over the past two decades, and the homes here reflect it. Larger floor plans, multi-zone systems, high-efficiency equipment, and newer construction in neighborhoods like The Fields, Phillips Creek Ranch, and Viridian. Keeping all of it running well takes an HVAC company that knows what it’s doing. Adon Complete Air Conditioning and Heating has been running calls for HVAC service in Frisco for years from our home base in Anna, just up the Dallas North Tollway corridor. We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.

Schedule HVAC Service in FriscoCall (903) 482-4900

What We Do for Frisco Homeowners

AC Repair. We diagnose and repair all makes and models. Frisco’s newer construction often means multi-zone systems and communicating equipment — our technicians know how to work on all of it.

AC Installation. When it’s time to replace, we size every system correctly using a proper load calculation. That matters especially in Frisco’s larger homes where an improperly sized system will short-cycle and leave rooms uncomfortable. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. For Frisco homeowners with high-end systems, staying on a maintenance schedule is one of the best ways to protect your investment.

Mini-Split Installation. Garages, home offices, casitas, and bonus spaces are common in Frisco’s larger homes. Mini-splits handle these spaces cleanly without touching your central system.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from one system and work well in North Texas’s climate. A practical choice for Frisco homeowners upgrading to a more efficient setup.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening. Frisco’s tight construction means less natural ventilation, making air quality systems more important than in older homes.

Air Duct Cleaning. Even newer ductwork accumulates contaminants over time. Professional duct cleaning improves air quality and keeps your system running efficiently throughout the home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. In a larger Frisco home, that adds up fast. We inspect, repair, and seal ductwork throughout the area.

Why Frisco Homeowners Choose Adon Complete

Frisco has no shortage of HVAC companies competing for business. Here’s why our customers keep calling us back.

We know multi-zone and communicating systems. The job notes from our Frisco calls show what we actually work on here – damper adjustments, multi-system diagnostics, communicating Trane equipment, humidity management in two-story homes. This isn’t routine work, and we handle it well.

Jesse Villarreal has over 27 years of experience. He’s the owner and is directly involved in how the business operates. When something goes wrong, you’re dealing with a company where the owner’s reputation is on the line.

We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. Factory-trained on the brands most common in Frisco’s newer construction. Full manufacturer warranty on every system we install.

The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. Straightforward and affordable.

Serving Frisco and Surrounding Collin County Communities

We serve all of Frisco, including The Fields, Phillips Creek Ranch, Viridian, Stonebriar, and the established neighborhoods along Preston Road and the Dallas North Tollway. We also serve the surrounding communities of Allen, McKinney, Anna, Melissa, and Sherman.

Schedule HVAC Service in FriscoCall (903) 482-4900

Frequently Asked Questions

Here are some common questions we get about our HVAC services in Frisco.

How much does AC repair cost in Frisco, TX?

Most AC repairs in Frisco run between $150 and $600 depending on the type of repair. Frisco’s newer homes often have multi-zone systems and higher-end equipment, which can affect parts costs. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you service multi-zone systems in Frisco?

Yes. Multi-zone systems and communicating HVAC equipment are common in Frisco’s larger homes, and our technicians work on them regularly. We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, and more.

Do you offer HVAC maintenance plans in Frisco?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. Preventive maintenance is especially important for the multi-system setups common in Frisco’s larger homes.

Do you offer emergency HVAC service in Frisco?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Frisco. When you call after hours, you reach a real person who can get a technician to your home fast.

What areas near Frisco do you serve?

We serve all of Frisco and the surrounding communities including Allen, McKinney, Anna, Melissa, and Sherman.

Ready to Get Your System Serviced?

Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online for HVAC services in Frisco. We handle everything from routine maintenance to emergency repairs throughout Frisco and Collin County.

Schedule HVAC Service in FriscoCall (903) 482-4900

Recent Jobs and Reviews in Frisco, TX

Rated 5.0 out of 5 stars based on 7 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Frisco, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Frisco, TX between August 2025 and September 2025.

The most recent job was on September 12, 2025.

Adon Complete Air Conditioning and Heating has completed 51 jobs in Frisco, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Shelby S.
Shelby S.
Upon arrival, I spoke with the homeowner about her concerns. I understood that the home is getting too cold downstairs. I noticed that the upstairs thermostat is taking in a bunch of heat from the windows resulting the unit running excessively. The system appears to have 2 air dumps downstairs. The customer would like to be able to set the thermostat and not have to worry about it being too cold. I proposed upgrading the thermostat to a smart one. I observed the refrigerant levels. The system appeared to be low. I proceeded to the attic to check in indoor equipment. I discovered that the evaporator coil is currently backwards causing an air restriction. I advised the customer to get a second opinion on me from another company to verify my findings. Also, I advised the customer to reach out to rescue air about the coil being backwards to save her some money.
Frisco, TX 75035
Frisco, TX - Upon arrival, I spoke with the homeowner about her concerns. I understood that the home is getting too cold downstairs. I noticed that the upstairs thermostat is taking in a bunch of heat from the windows resulting the unit running excessively. The system appears to have 2 air dumps downstairs. The customer would like to be able to set the thermostat and not have to worry about it being too cold. I proposed upgrading the thermostat to a smart one. I observed the refrigerant levels. The system appeared to be low. I proceeded to the attic to check in indoor equipment. I discovered that the evaporator coil is currently backwards causing an air restriction. I advised the customer to get a second opinion on me from another company to verify my findings. Also, I advised the customer to reach out to rescue air about the coil being backwards to save her some money.
Frisco, TX - Upon arrival, I spoke with the homeowner about her concerns. I understood that the home is getting too cold downstairs. I noticed that the upstairs thermostat is taking in a bunch of heat from the windows resulting the unit running excessively. The system appears to have 2 air dumps downstairs. The customer would like to be able to set the thermostat and not have to worry about it being too cold. I proposed upgrading the thermostat to a smart one. I observed the refrigerant levels. The system appeared to be low. I proceeded to the attic to check in indoor equipment. I discovered that the evaporator coil is currently backwards causing an air restriction. I advised the customer to get a second opinion on me from another company to verify my findings. Also, I advised the customer to reach out to rescue air about the coil being backwards to save her some money.
Shelby S.
Shelby S.
I installed a variable speed blower motor and new furnace control board. Once the motor was installed, I determined that the new motor was bad out of the box. Jose brought me a new motor and I replaced it again. The system in now up and running in 2 stage. I checked refrigerant pressures. I instructed the customer to give it the weekend to run. This way we can review runtime over the course of 2 days. System cooling upon departure and dropped the thermostat 2 degrees in 2nd stage.
Frisco, TX 75035
Frisco, TX - I installed a variable speed blower motor and new furnace control board. Once the motor was installed, I determined that the new motor was bad out of the box. Jose brought me a new motor and I replaced it again. The system in now up and running in 2 stage. I checked refrigerant pressures. 
I instructed the customer to give it the weekend to run. This way we can review runtime over the course of 2 days. System cooling upon departure and dropped the thermostat 2 degrees in 2nd stage.
Frisco, TX - I installed a variable speed blower motor and new furnace control board. Once the motor was installed, I determined that the new motor was bad out of the box. Jose brought me a new motor and I replaced it again. The system in now up and running in 2 stage. I checked refrigerant pressures. 
I instructed the customer to give it the weekend to run. This way we can review runtime over the course of 2 days. System cooling upon departure and dropped the thermostat 2 degrees in 2nd stage.
Brayden W.
Brayden W.
Arrived on site, homeowner notified me that water was coming out of the emergency drain lines on both sides of the house. Upon further inspection, I found that the drain lines were tied together draining in the upstairs bathroom. I removed the pvc that tied the drain line into the sink and replaced it with plastic tubing. We then installed blowout valves on both sides of the pipe so that we could isolate the drain. I proceeded to blowout the drain line and removed a substantial amount of sediment and algae. I then flushed and blew out the drain line repeatedly until the drain began to drain normally. We then installed and wired float switches to both units and tested them to make sure they were functioning properly. Tested extensively with additional water to ensure both sides are draining well and found them to be. We then proceeded to perform the maintenance. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades.
Frisco, TX 75034
Frisco, TX - Arrived on site, homeowner notified me that water was coming out of the emergency drain lines on both sides of the house. Upon further inspection, I found that the drain lines were tied together draining in the upstairs bathroom. I removed the pvc that tied the drain line into the sink and replaced it with plastic tubing. We then installed blowout valves on both sides of the pipe so that we could isolate the drain. I proceeded to blowout the drain line and removed a substantial amount of sediment and algae. I then flushed and blew out the drain line repeatedly until the drain began to drain normally. We then installed and wired float switches to both units and tested them to make sure they were functioning properly. Tested extensively with additional water to ensure both sides are draining well and found them to be. We then proceeded to perform the maintenance.
 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
Frisco, TX - Arrived on site, homeowner notified me that water was coming out of the emergency drain lines on both sides of the house. Upon further inspection, I found that the drain lines were tied together draining in the upstairs bathroom. I removed the pvc that tied the drain line into the sink and replaced it with plastic tubing. We then installed blowout valves on both sides of the pipe so that we could isolate the drain. I proceeded to blowout the drain line and removed a substantial amount of sediment and algae. I then flushed and blew out the drain line repeatedly until the drain began to drain normally. We then installed and wired float switches to both units and tested them to make sure they were functioning properly. Tested extensively with additional water to ensure both sides are draining well and found them to be. We then proceeded to perform the maintenance.
 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
Jacob P.
Jacob P.
Returned to our clients home because the compressor was frozen over. Paul had shut the unit off earlier this morning to allow for it to thaw out. I arrived and immediately proceeded into the attic. I verified the wiring to be correct and began to further diagnose the system. I placed the unit into test mode and was not getting the proper signal outside. I diagnosed the wire to have a short and used a spare wire to send the correct signal for second stage. I also contacted TRANE tech support and ensured the blower speeds were set properly for first and second stage cooling. I ran the system in cooling and assumed the coil was completely thawed out. It was not. I had to place the unit to run in heat to melt off the residual ice on the indoor coil. Once the ice was completely melted I was able to properly test and check the refrigerant pressures on first and second stage cooling. Within 20 mins the thermostat had dropped 3º and was cooling with a 20º drop. I showed pictures and kept Paul
Frisco, TX 75035
Frisco, TX - Returned to our clients home because the compressor was frozen over. Paul had shut the unit off earlier this morning to allow for it to thaw out. I arrived and immediately proceeded into the attic. I verified the wiring to be correct and began to further diagnose the system. I placed the unit into test mode and was not getting the proper signal outside. I diagnosed the wire to have a short and used a spare wire to send the correct signal for second stage. I also contacted TRANE tech support and ensured the blower speeds were set properly for first and second stage cooling. I ran the system in cooling and assumed the coil was completely thawed out. It was not. I had to place the unit to run in heat to melt off the residual ice on the indoor coil. Once the ice was completely melted I was able to properly test and check the refrigerant pressures on first and second stage cooling. Within 20 mins the thermostat had dropped 3º and was cooling with a 20º drop.
I showed pictures and kept Paul
Frisco, TX - Returned to our clients home because the compressor was frozen over. Paul had shut the unit off earlier this morning to allow for it to thaw out. I arrived and immediately proceeded into the attic. I verified the wiring to be correct and began to further diagnose the system. I placed the unit into test mode and was not getting the proper signal outside. I diagnosed the wire to have a short and used a spare wire to send the correct signal for second stage. I also contacted TRANE tech support and ensured the blower speeds were set properly for first and second stage cooling. I ran the system in cooling and assumed the coil was completely thawed out. It was not. I had to place the unit to run in heat to melt off the residual ice on the indoor coil. Once the ice was completely melted I was able to properly test and check the refrigerant pressures on first and second stage cooling. Within 20 mins the thermostat had dropped 3º and was cooling with a 20º drop.
I showed pictures and kept Paul
Shelby S.
Shelby S.
Upon arrival, I found the outdoor unit not coming on. I opened the panel and discovered the contactor not pulling in. I confirmed that I had 24v coming outside, but it wasn’t passing through the high pressure switch. Also, I noticed that the capacitor was bloated. I spoke with the homeowner about the options to address the issue: 1. Replace the hugh pressure switch. 2. Bypass the high pressure switch (runs the risk of damaging the system is high pressure becomes an issue) 3. Replace the capacitor 4. Do nothing. The customer opted to install a new 40/7.5 capacitor and bypass the pressure switch. After getting the system operational, I tested the system to check for further potential issues. I noticed that the outdoor unit is in need a chemical cleaning, but the customer declined further repairs.
Frisco, TX 75035
Frisco, TX - Upon arrival, I found the outdoor unit not coming on. I opened the panel and discovered the contactor not pulling in. I confirmed that I had 24v coming outside, but it wasn’t passing through the high pressure switch. Also, I noticed that the capacitor was bloated. I spoke with the homeowner about the options to address the issue: 1. Replace the hugh pressure switch. 2. Bypass the high pressure switch (runs the risk of damaging the system is high pressure becomes an issue) 3. Replace the capacitor 4. Do nothing. The customer opted to install a new 40/7.5 capacitor and bypass the pressure switch. After getting the system operational, I tested the system to check for further potential issues. I noticed that the outdoor unit is in need a chemical cleaning, but the customer declined further repairs.
Frisco, TX - Upon arrival, I found the outdoor unit not coming on. I opened the panel and discovered the contactor not pulling in. I confirmed that I had 24v coming outside, but it wasn’t passing through the high pressure switch. Also, I noticed that the capacitor was bloated. I spoke with the homeowner about the options to address the issue: 1. Replace the hugh pressure switch. 2. Bypass the high pressure switch (runs the risk of damaging the system is high pressure becomes an issue) 3. Replace the capacitor 4. Do nothing. The customer opted to install a new 40/7.5 capacitor and bypass the pressure switch. After getting the system operational, I tested the system to check for further potential issues. I noticed that the outdoor unit is in need a chemical cleaning, but the customer declined further repairs.
jcg311690@gmail.com
jcg311690@gmail.com
Warranty call on upstairs gas system from 2020. Customer stated that the system isn’t cooling properly and it takes a very long time to cool the upstairs down. During my inspection I found the evaporator coil and refrigerant lines to be somewhat frozen. I informed the customer that I will turn the fan on and wait for it to thaw out. In the mean time I inspected the rest of the system to make sure there wasn’t any airflow restrictions. I also inspected the electrical wiring and found that the thermostat had the Y1 (stage 1) and Y2 (stage 2) terminals connected straight to the condenser outside which means the thermostat controls the compressor and tells it what stage to use based on demand. With that being said the variable speed furnace doesn’t recognize that the compressor has two stages so when the thermostat called for cool stage 2 the blower in the furnace stayed in stage 1 and would never kick on that second stage blower causing the system to freeze up eventually leading to the
Frisco, TX 75035
Jacob P.
Jacob P.
Returned to our clients home to top of system with refrigerant. I had to wait about an hour for the rain to clear. Once cleared I proceeded to charge the unit with Freon. Once charged I took temperature measurements and ensured the system was cooling wit a 20º drop. The upstairs thermostat displayed an indoor temperature of 80º which I ensured with my temperature probe and found to be incorrect. I removed the thermostat and filled in the hole with some foam insulation. I also removed the plastic flowers that were covering the thermostat. I informed our clients that we cannot have the flowers covering the thermostat and before leaving the thermostat had settled to 76º. Paul also elected to replace the filter for the upstairs unit today. The system is cooling properly on departure.
Frisco, TX 75035
Frisco, TX - Returned to our clients home to top of system with refrigerant. I had to wait about an hour for the rain to clear. Once cleared I proceeded to charge the unit with Freon. Once charged I took temperature measurements and ensured the system was cooling wit a 20º drop. The upstairs thermostat displayed an indoor temperature of 80º which I ensured with my temperature probe and found to be incorrect. I removed the thermostat and filled in the hole with some foam insulation. I also removed the plastic flowers that were covering the thermostat. I informed our clients that we cannot have the flowers covering the thermostat and before leaving the thermostat had settled to 76º. Paul also elected to replace the filter for the upstairs unit today. The system is cooling properly on departure.
Frisco, TX - Returned to our clients home to top of system with refrigerant. I had to wait about an hour for the rain to clear. Once cleared I proceeded to charge the unit with Freon. Once charged I took temperature measurements and ensured the system was cooling wit a 20º drop. The upstairs thermostat displayed an indoor temperature of 80º which I ensured with my temperature probe and found to be incorrect. I removed the thermostat and filled in the hole with some foam insulation. I also removed the plastic flowers that were covering the thermostat. I informed our clients that we cannot have the flowers covering the thermostat and before leaving the thermostat had settled to 76º. Paul also elected to replace the filter for the upstairs unit today. The system is cooling properly on departure.
Brayden W.
Brayden W.
Arrived on site, homeowner complained of unit not keeping up with the set temperature. indoor temperature around 76° while the set point was 74. I waited for a little bit to see if the unit would kick on by itself which it did, and immediately shut itself off on a float switch error. Tested drain line and found water not draining and going up the service port after the P-trap. I blew out the drain line with nitrogen and then disassembled the drain line Connection to the front bathroom sink. I found a large amount of sludge blocking the half inch nipple elbow connecting to the bathroom drain. Reassembled drain line and blew out with nitrogen again and tested with several gallons of water. Drain line is draining properly at this time. Reviewed refrigerant pressures and temperature split from supply to return and found no issues. I also found the scheduling enabled on the thermostat. Homeowner had not set up, scheduling to his comfort on the app, so I disabled the scheduling so that the
Frisco, TX 75036
Frisco, TX - Arrived on site, homeowner complained of unit not keeping up with the set temperature. indoor temperature around 76° while the set point was 74. I waited for a little bit to see if the unit would kick on by itself which it did, and immediately shut itself off on a float switch error. Tested drain line and found water not draining and going up the service port after the P-trap. I blew out the drain line with nitrogen and then disassembled the drain line Connection to the front bathroom sink. I found a large amount of sludge blocking the half inch nipple elbow connecting to the bathroom drain.  Reassembled drain line and blew out with nitrogen again and tested with several gallons of water. Drain line is draining properly at this time. Reviewed refrigerant pressures and temperature split from supply to return and found no issues. I also found the scheduling enabled on the thermostat. Homeowner had not set up, scheduling to his comfort on the app, so I disabled the scheduling so that the
Frisco, TX - Arrived on site, homeowner complained of unit not keeping up with the set temperature. indoor temperature around 76° while the set point was 74. I waited for a little bit to see if the unit would kick on by itself which it did, and immediately shut itself off on a float switch error. Tested drain line and found water not draining and going up the service port after the P-trap. I blew out the drain line with nitrogen and then disassembled the drain line Connection to the front bathroom sink. I found a large amount of sludge blocking the half inch nipple elbow connecting to the bathroom drain.  Reassembled drain line and blew out with nitrogen again and tested with several gallons of water. Drain line is draining properly at this time. Reviewed refrigerant pressures and temperature split from supply to return and found no issues. I also found the scheduling enabled on the thermostat. Homeowner had not set up, scheduling to his comfort on the app, so I disabled the scheduling so that the
Brayden W.
Brayden W.
Arrived for the upstairs unit not cooling g properly. Client stated he noticed the issue a few days ago. We proceeded into the attic and measured the temperature drop. We only measured 11º drop. We then proceeded outside to the condenser unit. We connected our gauges and immediately found the pressures to be abnormal. We diagnosed a failed compressor. We informed our client of our findings and we will pick up and replace the compressor today under P&L. We are also going to proactively replace the indoor TXV for the unit. Our client is aware that the Parts and Labor warranties does not include cost of refrigerant.
Frisco, TX 75035
Frisco, TX - Arrived for the upstairs unit not cooling g properly. Client stated he noticed the issue a few days ago. We proceeded into the attic and measured the temperature drop. We only measured 11º drop. We then proceeded outside to the condenser unit. We connected our gauges and immediately found the pressures to be abnormal. We diagnosed a failed compressor. We informed our client of our findings and we will pick up and replace the compressor today under P&L. We are also going to proactively replace the indoor TXV for the unit. 
Our client is aware that the Parts and Labor warranties does not include cost of refrigerant.
Frisco, TX - Arrived for the upstairs unit not cooling g properly. Client stated he noticed the issue a few days ago. We proceeded into the attic and measured the temperature drop. We only measured 11º drop. We then proceeded outside to the condenser unit. We connected our gauges and immediately found the pressures to be abnormal. We diagnosed a failed compressor. We informed our client of our findings and we will pick up and replace the compressor today under P&L. We are also going to proactively replace the indoor TXV for the unit. 
Our client is aware that the Parts and Labor warranties does not include cost of refrigerant.
Matthew C.
Matthew C.
Preformed cooling maintenance on single system 2015. Tested all electrical components on the inside unit in attic above the office. All electrical components tested within manufacturer specifications range. The blower wheel is pulling high amps when running due to excessive dust and debris on the blower wheel its self. Temperature across the indoor coil was 79 return and 57 supply. I treated the main drain line with total c, rinsed off the reusable filter. I proceeded outside and checked all electrical components on the outside unit. All tested with manufacturer specifications range. The run amps tested within manufacturer specification range for the compressor and fan motor. The start amps for the compressor were testing above the manufacturer specifications range. I provided estimates for a blower wheel pull and clean to help bring the blower motor amps down. Also I provided an estimate for adding a hard start kit to the outdoor unit to her assist the compressor on start up and bring
Frisco, TX 75035
Frisco, TX - Preformed cooling maintenance on single system 2015. Tested all electrical components on the inside unit in attic above the office. All electrical components tested within manufacturer specifications range. The blower wheel is pulling high amps when running due to excessive dust and debris on the blower wheel its self. Temperature across the indoor coil was 79 return and 57 supply. I treated the main drain line with total c, rinsed off the reusable filter. I proceeded outside and checked all electrical components on the outside unit. All tested with manufacturer specifications range. The run amps tested within manufacturer specification range for the compressor and fan motor. The start amps for the compressor were testing above the manufacturer specifications range. I provided estimates for a blower wheel pull and clean to help bring the blower motor amps down. Also I provided an estimate for adding a hard start kit to the outdoor unit to her assist the compressor on start up and bring
Frisco, TX - Preformed cooling maintenance on single system 2015. Tested all electrical components on the inside unit in attic above the office. All electrical components tested within manufacturer specifications range. The blower wheel is pulling high amps when running due to excessive dust and debris on the blower wheel its self. Temperature across the indoor coil was 79 return and 57 supply. I treated the main drain line with total c, rinsed off the reusable filter. I proceeded outside and checked all electrical components on the outside unit. All tested with manufacturer specifications range. The run amps tested within manufacturer specification range for the compressor and fan motor. The start amps for the compressor were testing above the manufacturer specifications range. I provided estimates for a blower wheel pull and clean to help bring the blower motor amps down. Also I provided an estimate for adding a hard start kit to the outdoor unit to her assist the compressor on start up and bring