McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between May 2025 and June 2025.
The most recent job was on June 30, 2025.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
I arrived to our clients home for concerns that the unit was shutting off intermittently throughout the night. I began by checking for existing alerts on the main downstairs thermostat. I found none. I went into the alert history and found multiple pages of alerts dating back until 6/23/25. The majority of the alerts were all the same DATS Trip. Our client was able to show me pictures of the same alert on a previous date which was not saved in this alert history. I am unaware as to why not all the previous alerts are saved on the thermostat and can only determine it may have to do with the thermostat capacity to store alerts. I then went into the attic and replaced the DATS sensor. Once replaced I turned the system on and it began to cool. I measure the temperature at the supply and it was pushing 53° air. The unit is cooling properly on departure. We discussed the potential to contact and coordinate a Trane tech support visit if the issue persists. Otherwise I suggested replacin
Arrived to our clients home for questions regarding replacement equipment. I was first shown the indoor attic equipment and corresponding zone controls. I answered all of Mr Ottobre’s questions and we discussed various options for replacement in his home. He elected to move forward with the 18 SEER variable speed option. We are scheduled to install the new system on Wednesday. He will pay the remainder amount after the installation is completed. $1,000 check deposit collected today
Found indoor evaporator coil partially frozen and water in auxiliary drain pan. Ran furnace to thaw coil. Performed electronic refrigerant leak inspection. Found refrigerant leak in evaporator coil caused critical failure of system. Checked all electrical components. Weak capacitor for condenser System manufacturer warranty expired in 2019. Homeowner declined removal of retaining water charge. Topped of unit with 9lbs of refrigerant and directed enject leak seal Installed 45/5 capacitor. Recommend replacement of system. Comfort advisor visit set up.
Returned to home because our client a found a piece of his exterior drain line on the ground. I took off the metal protective cover for the line set and was able to see the exit point of the drain line from the home. The line is actually all flexible clear tubing. The metal cover is without a cap. Upon identifying the flexible tubing I believe the tubing flexes and causes the restriction in the line periodically. This would explain the periodic dripping our client sees within his home. Because the last time I was here I poured a significant amount of water without any issues. I used duct tape to provide a temporary solution. I lifted the flexible drain tubing to create more of a looping bend and secured it to the electrical conduit. This is only secured with duct tape and I cautioned Mr Williams that this may fail especially with the heat and with the metal cover not having a top Allowing for the ambient elements to get to the duct tape. He is aware of this and we discussed a perman
Upon arrival, I found the outdoor unit not operating. I opened the panel outside to find the contactor not pulled in and verified power. I isolated the pressure switches and found that the low pressure switch was not passing power through it. I confirmed that the high pressure switch was passing power. I hooked up my gauges and the system has more than enough pressure for it not to be tripped. I went and spoke with the home owner about options to address the issue. Customer chose to move forward with replacement of a brazed pressure switch and opted out of bypassing it to get it cooling. Customer signed up for monthly membership and service fee was waved. I collected 24 dollars for membership and 1000.00 deposit on repair. Scheduled for 6/25/25 2-3pm arrival time.
Replaced capacitor. Everything working as intended. Tested start and run amps; testing within range. Unit in good working order upon departure.
- Found faulty/failed thermostat for zone one/downstairs. - System currently draining properly and hasn’t retained water. - pulled common wire on zone board/ damper two…to finish diagnostics. - Checked filter/ 20x25x2 / clean / points correct direction - Checked all electrical components as well as refrigerant charge. - System currently functioning cooling properly, except for downstairs zone due thermostat needing to be replaced. Homeowner said he would replace his own thermostat. Instructed him that if he chooses to do this himself to turn off the main power in the attic to the indoor equipment so not blow any fuses or cause any other damage. - System cooling and draining functioning properly upon departure.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange Customer complained of humidity around 60%. Measured sufficient temperature on supply for dehumidification. Could be due to stress on the unit very dirty outside coil. Advised customer to adjust dehumidification settings on nest app to improve dehumidification. Capacitor was testing right on the edge of manufacturer specs. E
I arrived at our clients home for a 2 zone, single system cooling maintenance inspection. I began outside by checking and testing the electrical components to the condenser unit. The capacitor is beginning to fail and the contactor tested at 20 ohms, This is its maximum limit. The compressor was also starting at 153 amps. I then rinsed the outdoor coil from all the debris it had collected. Once washed the compressor started up at 94 amps. Still high but within range. I then went into the attic and treated the drain line. Measured the temperature drop and tested the blower motor. Everything passed inspection in the attic. I showed my findings to our client and we discussed adding a Hardstart kit to help keep the start amps in range and replacing the contactor on the outdoor unit to make sure it doesn’t fail in the middle of summer. He requested that we send an estimate and discuss the options with his wife. The unit is cooling on departure.
I returned today for our clients concern that the drain line was leaking water and needed to be adjusted. I arrived and our clients informed me of the water that had been dripping yesterday. I immediately proceeded to grab some water bottles and poured 32oz of water and checked to see if the drain line was either clogged or compromised. It was not. I used the TOTAL-C product down the mini split drain pan and recorded a video of the drain properly flowing without any backing up or issues. I took apart the unit also and ensured the drain line was insulated. It was. I explained that moving the drain line lower would require a large hole in the wall as well as cutting into the plastic panel of the actual mini split. We discussed how the cold condensation may have been struggling to drain fast enough and therefore creating more condensation in a spot that was ultimately leaking onto the floor. We discussed that keeping the drain line free of debris and actively cleaning it was the best pra
I found the primary drain line slowly draining and causing the system to trip on the float switch. I purged the drain with nitrogen and flushed it with approximately 3/4 of a gallon of water. The drain is now fully operational.
Returned to home to preform deep clean of mini split unit. Once we took apart the mini split we sprayed it down with chemicals and began the process of cleaning unit. Once the we were finished cleaning the unit we reassembled the pieces. We showed the client how to treat the drain line and educated on how often the client should clean the units filters. We tested the unit to ensure that the unit was cooling properly. Client was satisfied with the reduced noise and the unit was sounding perfectly.
Arrived to mini split vibrating and making a loud noise. Our client had the system off and showed me the front cover that he had removed. A piece had broken off and he was worried that it had fallen into the blower wheel. I found the piece on top where the coil is and not in the wheel. I further inspected the blower wheel and found it to be very dirty with growth and debris collected on it. The vibrating noise is is consistent with that if just a dirty blower. I discussed with Tommy and his wife Dixie that the unit needs to have a deep cleaning preformed to eliminate the noise and ensure the unit keeps preforming properly. They agreed to have me service the unit and also join our maintenance plan. We are scheduled to return tomorrow to clean the mini split. The unit is currently off.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange Found bad cap on master bd unit on fan side. Compressor side was testing fine. Recommended replacement. Replaced capacitor under labor warranty. Found high start amps on u/s unit recommended hard start kit to prolong system life
VIP Annual Service Agreement - 1 Unit Fall & Spring Annual Maintenance Visits 10% Discount on Repairs Discounted $45 Travel Fee (Usually $79!) Preferred Customer, (top placement in our emergency list) -Contactor -Turbo Multi Use Capacitor - 5-2-1 Hard Start Kit
I arrived at our clients home for the unit not cooling properly. They had informed the office that the unit was frozen over both inside and out. I proceeded to test all the electrical components and found everything to be turning on if water when checking the refrigerant pressures I confirmed it was low. As a courtesy I preformed a leak search in the indoor closet unit and identified a leak in the evaporator coil. I showed my finding to our clients and we discussed equipment warranty. According to the AirHandler serial number the unit is under warranty until 5/4/2029. The Taylor’s elected to proceed with the evaporator coil replacement only. We will call the manufacturer on Monday to locate the coil and update the Taylor’s with an ETA regarding the repair. As a courtesy I did add refrigerant to the unit to get them cooling for the time being. We did also waive the dispatch fee from today’s visit. I did collect a check for $500 as a deposit for the repairs.
The unit tripped due to either a power surge or straining to perform. 1 year old 1” filter. I reset the unit and everything powered up. I put it into a test cycle at the thermostat at the u it is fully operational.
We arrived to the clients home to evaluate replacement options. We attempted to contact the client and could not leave a voicemail as mailbox was full. We inspected the attic unit and identified potential spots in the home to add new return vents. The home has metal ductwork in reasonably good condition. All existing return vents downstairs may need to be moved due to being sealed off and over small size of existing return vents. The upstairs return vent would still work in its current location and condition. We will create and estimate and follow up with the homeowner regarding timeline, budget, and overall needs for the new system and the home.
Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty,,noticed doesn’t have surge protection, recommended to install one . 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,failed,, was replaced today. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,, it’s dusty, highly recommended a blower cleaning. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines,,,it doesn’t have any water safety switch installed, highly recommended to install one of them and benefits of having it. 16. Washed condenser unit. 17. Tested contactor. Found no more issues/ concerns at
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange
We inspected the unit for return lines relocation,,, unit has 3 return lines (12,10,8),, unit has hard pipe lines,it is also 11 years old, we were not able to finish the estimate because customer never showed up, we highly recommend to replace the whole system including ductwork,, we found blower housing/ motor/ wheel sitting outside, blower motor was leaking oil, at this point we don’t know if it was replaced,,,we didn’t open it.
Arrived at our client home for a 2 system cooling maintenance inspection. Our client showed me the attic access and we visually inspected the air filters and found the downstairs filter to be dirty. Our client did not have filters for replacement today. I then went outside and tested all the electrical components for both outdoor units. Everything passed inspection today and tested within range except for the upstairs unit. The compressor motor had extremely high start amps for the compressor. I showed this to our client and we briefly discussed adding a Hardstart kit to this unit to keep the compressor in a normal healthy range. I then proceeded into the attic. I inspected and tested the blower motors run and start amps, cleaned the drain line and tested the temperature drop for both units. On the upstairs unit I was only getting a 13° drop and went back outside to double check my Freon pressures. I did confirm the unit to be low on refrigerant. I presented my finding to Mrs Rojas a
Performed a 1 system spring maintenance ( heat pump). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines,,, main drain line doesn’t have any water safety switch in case gets clogged up,, recommended to install it,,emergency drain pan shows some rust ( looks like 55x36),,recommend a pan treatment. 16. Washed condenser unit. Unit is cooling properly at this time, found no issues.
Performed a 1 system spring maintenance ( heat pump). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty,,,noticed there’s no surge protection on the unit. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. System is in brand new condition,,,found no issues at this time.
Upon arrival customer stated that there was a whirling noise coming through the vents. We checked the amps of the blower motor with the door open and closed to see if we could hear unusual noise coming from the blower, blower motor amps tested within range. Upon further inspection we found the ceiling return grill door to be vibrating causing the noise. We offered to adjust it for the client but client declined and said he would take care of it.