McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between April 2025 and May 2025.
The most recent job was on May 20, 2025.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
Took measurements of return filter for 2 units,,, found one of them open,, customer stated that one of them wasn’t cooling properly,, highly believe it’s the one we found open,,both units are using 2 inch filters one of them might be 16x32x2 (2),,, the other one seems 16x23x2 (4)on this one it can be 2 or 4 inches,,will upload pictures for better reference this unit was found without filters,, didn’t have any.
Performed a 3 commercial spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty,,,return plenum on unit #2 is extremely dirty,, needs to be clean as soon as possible. 11. Inspected evaporator coil,,evaporator coil on units #2,3 are very dirty,, they need to be cleaned as soon a s possible,, they are not allowing enough airflow inside the building. 12. Inspected blower motor/ blower wheel,,,unit #2 needs to be cleaned as soon possible it’s extremely dirty ,,,belts need to be replaced as well they present signs of tear and wear. 13. Checked blower amp draw. 14. Measured temperature differentia
Performed 2 system cooling maintenance. I checked amps, capacitors, filter, refrigerant, electrical, safeties, drains, and cleanliness. The systems are performing mostly within manufacture specifications. I observed that the emergency drain pans on both systems have an excessive amount of rust. It is advised to replace these pans to remove the risk of the pan rusting out. With the installation of new pans, it will be included to line these pans with a water resistant spray to combat rust. The downstairs system’s outdoor 45/5 capacitor is reading just under the manufacture specification. This means that the compressor can stop at anytime, but will continue to run for now. It is advised to replace the capacitor to eliminate an unnecessary service charge. I provided options for a generic capacitor and a upgraded capacitor with a 5 year warranty.
I installed the discharge temperature sensor and tested the system in heat pump mode. The system heats perfectly fine in heat pump mode and does not get assistance from the gas. I let Jesse remote into the thermostat from the office to monitor it. The system ran for 24mins at full capacity without faulting. Customer is still concerned that the issue is still present.
Arrived to clients concern that the sink was backing up and that he did not receive an algae stick with his maintenance. I confirmed that we did in fact blow out the drain line on our previous visit. I proceeded to the attic and replaced the algae stick. While in the attic I found a dead rat on a trap and informed Paul. He will call pest control to remove the body. I checked the primary drain line and confirmed it did not have any backed up water nor evidence of clogging. I had some slight resistance but I discussed with Paul how this may only be isolated to the sink and not the havc drain. The unit is draining properly on departure.
Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter,,,it was in good condition and didn’t need to be replaced at this time. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines,,,noticed some water in the emergency drain pan,, it’s coming from the roof traveling through the flue pipe, according to customer there was a leak and still working on it, she was going to call the roofer back and take care of it. 16. Washed condenser unit. Found no issues/ concer
Arrived at our clients home for the cooling maintenance inspection. Our client had recently replaced his air filters and did not need them changed today. We first began by inspecting if we could relocate a thermostat for Lynn in the upstairs hallway. We are able to preform the service but she declined to have it done today. We then proceeded outside to the condenser units and tested all of the electrical components for each unit. The smallest unit for the media room is struggling to cool. Our client is aware of this and is potentially interested in removing it completely and adding the ductwork to another unit. We discussed how only changing the duct work to the unit would cause stress on the unit due to the extra demand. And the better option would be to upsize the system for the entire upstairs space. The main downstairs unit passed today’s inspection and is running properly. The master bedroom unit has very high start amps. This unit is already 11 years old. I did create an estim
completed forms
I arrived at our clients home for a second opinion for items found on an inspection report. The inspector identified the downstairs unit making a “loud noise” in the attic. I proceeded into the attic and turned the unit on to cool. This unit has a variable speed blower motor and on the low stages I could not hear anything. When the unit increased its speed I could not identify any loud noise outside of the units normal operation. We also turned on the upstairs unit and could not identify any noise outside of its normal operation. Everything is testing within range and there is not a loud noise identified on either units.
I arrived at our clients home for a two system cooling maintenance inspection. I began by changing all of the air filters inside the home, which our client provided today. Once all the filters were replaced, I proceeded to test and inspect the electrical components for both outdoor. Rinsed the outdoor coils as part of today’s maintenance. Once that was completed, I proceeded inside to test and inspect the blower motor and the blower wheel. Our clients had concerns for two bedrooms, receiving too much cold air. Previously, they were not using these bedrooms, but more recently , they have their grandchildren staying in the bedrooms. I did find and identified the duct work that went to these bedrooms, respectively. I did reduce the dampers for these rooms and our clients will monitor the airflow. I did also create and send an estimate to perform full system airflow to help the system. Everything is running properly on departure and our clients renewed their maintenance agreement for one m
Perform single system cooling maintenance. The system was installed in 2023. It is a communicating heat pump. I checked amps, filter, drains, electrical, thermostat, refrigerant temperature, and temperature differential. The system is cooling inside of manufacture specifications. I presented the air scrubber audio book and spoke about insulation. The customer is not interested in insulation or the Airscrubber at this time due to other projects. A price for the Airscrubber was requested for future reference.
I returned to our clients home with concerns that the unit for her bedroom was not cooling properly. She showed me that the indoor unit was responsive and pushing air but it was not cold air. I immediately requested we go outside to the condenser units. I found one of the unit breakers to be left off and immediately after turning it on it began to run and cool the bedroom. We then discussed the leak that Cesar had found and we also discussed how the coil replacement was not going to rejuvenate the system or extend its life any longer than normal. We discussed how the thermal overload is a protective function of the compressor but it still produces a lot of ware and gate on the compressor motor. She is now aware of this and would still like to move forward with the repair tomorrow.
Performed a 6 system spring maintenance ( heat pump/AC /Gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty,,,,,#2,4,6,7 will need a duct cleaning, return plenums are very dusty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,,,#2,6,7 are dusty , highly recommend a blower cleaning. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. Found #6 low on refrigerant, proceeded to do a leak search, found it at the evaporator coil,,, this will be replaced. Outdoor unit #1 guest room capacitor outside of manufacturer specs 3
I investigated the customer’s concerns about an odor in the upstairs area. The smell is confirmed to be Dirty Sox Syndrome but it is more noticeable on the upstairs. This is because the upstairs zone has fewer ducts and more air flow. I presented the airscubber digital book and offered biocide treatment on the evaporator coil. I informed the customer that it is not a guaranteed long term fix of the issue especially if only the treatment is done.
I arrived at our clients home for a unit not cooling. Our client noticed the issue in the evening. I began upstairs and confirmed the indoor unit was running. I proceeded outside and found a burnt wire that had damaged the contactor from the capacitor. The capacitor was still testing in range. I further tested the unit because I was not getting proper voltage to the contactor. I found that the low voltage had shorted the thermostat and it was not sending the correct signal to power the outdoor unit. This most likely happened due to the contactor back feeding and damaging the thermostat. I showed all my finding to our client and he elected to replace the thermostat with a trane 824, replace the contactor and add a Hardstart kit to help the compressor. The outdoor coils were completely restricted with pet hair and debris. I did also preform a cooling maintenance today and washed the outdoor coil. Mr Bruno also provided a filter to be replaced today. We did discuss replacing air filte
I arrived at our clients home for a 2 system cooling maintenance inspection. I began by first locating the thermostats and attic access for both units. I then went outside to inspect and test the condenser units for both systems. Everything passed inspection today, the only area of concern is the older main unit is surrounded by bushes that need to be Mai gained and trimmed as to not restrict airflow for the unit. I then proceeded into the attic for both systems and tested the temperature drop and cleared the drain lines. The larger main area unit has had rodent activity in the past and our client provided white vinegar to be unused in the drain line to help detour rodents and also keep line clean. This unit also has a significant amount of dust accumulated on it and should be cleaned. I showed pictures of the dust to our client and they did complete some renovations that contributed to the dust in the home. I will send over a blower wheel cleaning estimate but our client want to wa
Customer stated that the unit (#2), wasn’t working, that it was completely off that the thermostat was blank at a times,,, but it was doing this just on cooling mode. Started diagnostic at the thermostat, set it to cool, proceeded to inspect the indoor unit, verified proper voltage power signal to cool, noticed notification at the thermostat saying waiting for equipment,,, proceeded to inspect the outdoor unit, found a bad 2 pole contactor, brought this up to customer’s attention, decided to replace the part today, after replacement we verified proper system operation, found no more issues at this time.
Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty,,,recommended a surge protector this would protect the outdoor unit from over current to. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor,,,recommended a hard start kit this extends the life on the compressor and releases stress at start up. 6. Checked refrigerant pressures. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,,,both are dusty highly recommended a blower cleaning,, this prevent buildup on the blower wheel then unbalance. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser unit. Unit is cooling prope
I found the outdoor unit tripped on a hard lock out. The defrost board did not give any information beyond that. I hooked up my gauges and reset the defrost board. The compressor started with no issues pulling 8.5 amps on start up. I watched the refrigerant pressures and it appears the pressures are low. I covered the unit to simulate a harder day and the subcool was at a 3.1 at the highest and the super heat was 23.3. I offered pricing to add refrigerant and the customer declined. I spoke with the homeowner about part availability and the possibility of finding 410a replacement parts. The system could need more than 3 pounds and this would be determined when adding.
Arrived on site, customer stated unit was not cooling while running. Upon initial inspection, it was noticed that two filters were being used a 4 inch on the unit and 1 inch filters on the ceiling. Proceeding to the outdoor unit, it was noticed that the coil on the condenser was pretty dirty. Upon further testing, it was found that the unit had exceeded the locked rotor amps. The compressor had gone into lockout safety not allowing the outdoor unit to turn on. We reset the safety and tested the outdoor unit. We found the compressor to have exceedingly high start amps over the manufacture limit. We showed our findings to Paul and we discussed options to bring start amps into normal range and also maintain the overall performance of the system. Our client elected to have the maintenance preformed today and we flushed and cleaned the drain line as well as washed the outdoor unit. Our client also elected to install a hardstart kit to help keep the compressor amps within manufacture specif
Arrived to unit not cooling and continuous blown fuse inside the furnace. Upon arrival David explained he had replaced the thermostat and 3 different fuses and the unit would not come on in cooling mode. I immediately proceeded outside and found a failed contactor. I further tested the unit and found the capacitor to have early signs of failure. I showed my findings to David and he elected to replaced both components today. Once replaced I further tested the unit to ensure it was cooling properly. I found the compressor start amps to exceed manufacture specifications. I also found the indoor blower wheel to have significant dust accumulated on it from candles and dust in the home. The indoor blower motor was reading 9.36 and is max limit is 10. I discussed with David how the dust on the blower motor is contributing to significant wear and strain on the system. I will send over an estimate for blower cleaning and a hard start kit to help the compressor. The system is cooling on depar
Arrived at clients home for ongoing issue regarding heat pump heat vs gas emergency heat. Our client confirmed that both zone thermostats are set to either heat or cooling only and not on auto. Our client said that the indoor temperature was reading below desired set point and they had to manually set the thermostat to emergency heat to come on and heat the home. I proceeded into the attic and found the air filter had not been cleaned from our last visit in February. Our clients are currently doing different home renovations projects which are contributing to high amount of construct in the home and being caught by the filter. We discussed how the filter is set to notify after a set period of time and not by the actual cleanliness/dirtiness of the filter. Today, as a courtesy, I dusted off the filter and sent a video to our client on what other parts of the filter still need to be cleaned. I did not preform a full filter cleaning and our client was deliberate about not wanting to p
Performed a 2 systems spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motors. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitors. 6. Checked refrigerant pressures. 7. Checked compressors amp draw. 8. Checked condenser fan motors amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenums for debris/ dirty. 11. Inspected evaporator coils. 12. Inspected blower motor/ blower wheels. 13. Checked blowers amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 16. Washed condenser units. Found no issues/ concerns units are working properly at this time.
The system is not cooling at factory specs. There is a leak on the coil, and it needs to be replaced
Replacement of failed humidifier control board Clearing drain line to ensure proper drainage on primary drain line for master bedroom unit and humidifier. I returned to our clients home today to complete Previously quoted repairs. Upon arrival Karl informed me that water had been leaking from the upstairs unit drain pan. We proceeded into the attic and found the primary drain line completely disconnected from the primary drain line outlet. It appeared to not have any pvc glue or adhesive from the time of install. The line was short and did not make a secure connection. I added a small piece and coupling as a courtesy, to better secure the drain line. Karl wanted to move forward with his remediation company. I then went to replace the steam humidifier control board. Once replaced Karl and I turned the unit to heat and ensured the humidifier was working properly and creating steam. At the same time I flushed and cleared the primary drain line with nitrogen to help prevent future clo