McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between July 2025 and August 2025.
The most recent job was on August 11, 2025.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
-Contactor -Turbo Multi Use Capacitor - 5-2-1 Hard Start Kit Arrived for a 5 system maintenance inspection. Upon arrival I first found water dripping from the ceiling. This water was from a previous unit we had serviced a few weeks ago. I proceeded to install another ball valve and clears the drain line before proceeding forward with the maintenance today. We then proceeded to measure the temperature drops for each individual unit and also test and inspect the electrical components on each condenser unit outside. All 5 of the condensers were extremely dirty with grass and debris build up. This has been causing the outdoor equipment to work harder and pout strain on the electrical components. All five of the capacitors were testing at or below manufacturer limits as well as the contractors. We showed our findings to Karl and e elected to replace them with electrical rebuild kits today, this would exp reduce the amount of stress on the compressors and help on startup. Once replaced w
Demand call for package unit from 2015 not cooling properly. Upon arrival the maintenance worker showed me around and mentioned that they’ve had a contactor outside replaced, he changed the thermostat himself because it just kept on turning on and off every time it called for ac, and changed the air filters. During my inspection the fans outside and inside were running but the compressors weren’t. I inspected the thermostat wiring and found the thermostat to not be wired correctly or programmed correctly. I fixed that and continued to inspect the system, I later found the contactor that had been replaced had been wired incorrectly and was actually bad again. I informed the customer and he agreed to have me fix the contactor and properly wire the system. After the repairs the system started up and starting cooling properly. Temperature inside went from 76 to 70, I also did a quick rinse on the outside coil to help the efficiency increase a little bit. System is running upon departur
Upon arrival, I found that the fuse was popped again. Upon further investigation, I found that the system was programmed for gas. I corrected it, replaced the fuse, and tested it. I found the blower motor is scrapping really bad. To address this issue, we need to replace the motor, blower wheel, and blower housing. Carrier priced the wheel for me, and they told me the housing is unavailable with no replacement parts. I priced the blower with the wheel, and system replacement. Customer wanted us to call to collect the dispatch in an hour. *** This unit will fail again *** Unit is a 2004 heat pump with the outdoor bypassed to run only cooling.
System not cooling scheduled appointment tomorrow. Informed customer we would call them in the morning.
Upon arrival, I found the thermostat half way popped off the wall. I removed it and found the prongs damaged and the fuse popped in the airhandler. I installed my short finder and found no issue without the thermostat present in the wiring. Customer wanted to install their thermostat themselves.
Upon arrival, I found that the capacitor for the downstairs unit was bloated. This is a sure indication that the capacitor has failed. I replaced the failed capacitor and tested the unit. The system is fully operational with no other concerns. The upstairs unit was operating and the refrigerant pressures were good. I noticed that the unit had a bunch of build up causing the unit to not be able to exhaust the heat properly. I performed a chemical cleaning and now the unit is cooling properly.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange Found condenser coils very dirty, Blower wheel was very dirty, and contactor was testing badly with signs of pitting and arcing. Advised homeowner that this contactor could fail at any time, recommended replacement. Homeowner elected to wait until the next maintenance to get the issues addressed as he did not have the funds
Found indoor air handler breaker switched off. Flipped breaker and unit came on without issue and continued to run. Unit in good working order upon departure.
Upon arrival found unit to be low on refrigerant. 63 supply temp. Performed courtesy leak test and found leak in the evaporator coil. Homeowner elected to go with a leak seal and recharge. Unit holds 5.5lbs of refrigerant. Performed leak seal and recharged the unit with 3 lbs of 410a. 55 degree supply temp and 76 return measured. Pressers were back within range but subcool and super heat were still a bit off. Recommended coil cleaning to homeowner. Also checked drain line and found it to be draining at this time. Moved some insulation that was allowing water out of the pan. Unit in good working order upon departure.
VIP Annual maintenance member. First visit of two visits. Performed AC/Cooling maintenance. Provided courtesy call to homeowner to verify address and to confirm appointment time. Upon arrival met/greeted homeowner/ Mr Farrakhan at front door. Provided a demand for AC at both thermostats. Thermostats/zone control board/damper motors/sensor..are all communicating and but upstairs damper doesn’t close properly during diagnostic due to gear failure. Checked all electrical components/motors, refrigerant charge, drain lines, high/low voltage wiring. Treated drain lines with Total C drain treatment. System not retaining water and draining properly. Water Washed/Detailed Outside Condenser coils Made courtesy repair with homeowners materials by air sealing coil housing door to supply air distribution plenum. Refrigerant charge is at/within manufacturers operating specifications. System provides a 20-21°F …delta temperature drop across the coil and is currently cooling, functioning, draining
I arrive for a second opinion regarding new equipment or repair. I began to diagnose the outdoor heat pump and found a failed condenser fan motor. We discussed how a failed motor will cause the compressor to overheat and lockout. I was able to locate a replacement motor at a local supply house and went to pick it up. I returned and replaced the motor. Once replaced I turned the unit on and ensured it was running properly. The unit was cooling the best it could but I could audibly hear the indoor blower whirling and creating a noise inside. I pointed this out to the homeowner and verified that the thermostat was working properly also. The unit is cooling on departure.
Attempted to provide courtesy call to client prior to arrival… left voicemail. Upon arrival met Mr & Mrs Kaufmann. Homeowner explained his concerns with how the downstairs system isn’t functioning well and is always running to maintain setpoint. Approached thermostat:wasn’t running, noticed it’s setpoint of 73 and reading 73. Provided a demand call at thermostat for cooling on downstairs equipment only to perform diagnostics. System started functioning inside and outside. Homeowner just replaced filters. Inspection of air distribution assembly, motor, & wheel are extremely dirty affecting efficiency/performance. System not retaining water and appears to be draining properly…no float switch present, no insulation on primary drain. Downstairs outside equipment/condenser coils extremely dirty/ restriction affecting efficiency and performance. Upon inspection of outside condenser coils technician noticed oil spot. Performed courtesy electronic refrigerant leak inspection and verified out
Upon arrival, I found air leaks causing a small amount of water to drip in to the emergency pan. I sealed the evaporator to the best of my ability without mastic. The customer declined the mastic and I informed him that I can not guarantee that it will not do it again. The customer requested pricing to clean all of his ducts. The customer would like pricing on a 5 system level 3 duct cleaning. I asked the customer to give us until next week to get a price together. This will require big ladders. Seal spot on the front of the evaporator coil that is leaking air with metal tape and mastic seal.
Return to add refrigerant to system. Added 2 pounds 2oz. Unit was cooling on departure. Left unit cooling on departure will schedule replacement coil once part is acquired.
Arrived on site, and found drain line had a large amount of sludge. However the line appeared to be clear and draining properly when tested. Measured refrigerant pressures and found unit to be low on refrigerant. Tested for leaks in the evaporator coil and found leak. Noticed that condenser coil was extremely matted and covered in debris. Also found a 12x12x1 filter that appeared to have not been changed as it was so blocked up with dander and dust. Both of these could have contributed to stress on the unit. I called Lennox to check warranty status and availability of coil. Coil is under parts and labor warranty customer is only responsible for refrigerant and filter dryer. Coil is not in stock and is about a week out. Advised customer we would be able to top off the unit as a courtesy to hold them over until we have the coil in hand. Order number# 40156728
Arrived on site found water in float switch indicating the unit is not draining. Upon testing found drain clear from service port onward. Removed Evap cabinet door to better assess the issue and found significant amount of algae in the coil pan. Algae had solidified into a sludge preventing draining. Vacuumed out as much as I could and flushed the rest with water and nitrogen. Tested and unit is draining as intended. Upon getting the unit operational again I tested contactor and capacitors outside and found all to be well. Noticed significant dust and debris build up on outdoor condenser coil. Pressures were within range. Discussed possible options for preventing this from happening again in the future. Homeowners elected to go forward with the maintenance program and adding algae sticks to the coil pan in order to prevent algae growth. Rinsed condenser to promote heat exchange. Unit in good working order upon departure.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Found bad capacitor on U/S left unit #2. Customer approved replacement and I replaced the capacitor. Also noticed a large amount of dust on the blower motor and high amps flowing through this motor. All other unit were testing within range and found no issues with their operation. All drain l
I arrived at our clients home for a dehumidifier estimate. I began by listening to our clients concerns about the upstairs space feeling musty and struggle to keep the space comfortable. I proceeded upstairs and immediately identified that the downstairs system has a fresh air ventilation damper connected to the system. I found that it was opened and actively pulling in ambient air. I discussed this with our client and we discussed options of turning it off and monitoring the humidity levels for a few weeks. In further diagnosis I found the motor to be stuck and unable to close completely. I showed this to our client and presented the option to sever the duct and cap the damper to prevent it from pulling in air. We agreed this would be the first step before moving forward with a dehumidifier. Once the work was complete I was able to speak to Mr Bui over the phone and also summarize the work that was done and how it would address the overall humidity in the home. We also discussed
For this job we returned to further diagnose and correct the issues found we turn the system on and connected it to the trane technician app without any issues we then went through the set up and Iran the unit in test mode we had a small issue of telling the new furnace control board the correct size of the blower motor and speed we contacted tech support and they were able to guide us through the process once everything was properly connected and calibrated we ran the unit in r test mode for 20 mins without any issues we then went through the shut the unit off and connected the new thermostat to the Wi-Fi and after ensured it was connected to the homeowners app on his phone we ran the unit for more than 30 mins without issues and ensured it was cooling properly on departure
Upon arrival homeowner stated everything was cooling great, he was concerned about when the unit started up you could hear the blower louder than before, advised home owner everything was working in normal operational condition. Preformed cooling maintenance tested all inside and outside electrical components. Everything tested within manufacturer specifications. Start and run amps on fan and compressor motor tested with in manufacturer specifications. Treated drain line with total c and we got a split of 19 degrees across the coil. Unit was cooling upon departure.
Arrived at our clients home to a drain pan full of water. I immediately used my lungs to push the clog through. I could feel it clear but asked Mr Ottobre if he could show me where the condensation drain line was connected. He took me to the a sink in the master bedroom downstairs. I used a light and verified that the drain was debris collected and contributing to the clog. I then used nitrogen and the Total-C product to flush and clear the drain line as well as disassembled the P trap under the sink to clear the residual debris. Once it was completely clear I again used water and Total-C to flush the drain line again. I vacuumed out the water from the drain pan and ensured the primary drain line was free and clear before leaving.
Upon arrival client mentioned water coming out of the secondary drain lines and to outside. We checked the pan and noticed a substantial amount of water in the pan. We proceeded to check the other two units as well and one had some standing water in the pan as well. We determined the two main drain lines on the units were clogged. We presented our findings to the clients wife and she approved the drain clearings. Each line has been cleared and treated with total c. Maintenance for this 3 system house needs to be schedule for a future date. Units were cooling properly upon departure. CONDENSATE DRAIN LINES NEED TO BE CLEANED OR THEY CAN CLOG WITH ALGAE AND DEBRIS Includes shop vacuuming when necessary and 1 PVC Coupling Also installation of a Quickblast PVC fitting, which improves accessibility for future maintenance.
Came out today for QC visit on new install. Started inside at t-stat turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components were checked and tightened. All components are operating as designed. Pressures were within manufacturer specifications. Found condensation on attic unit. Adjusted airspeed from minimum 250 to 350CFM. Eliminated sweating on coil and plenum after airspeed changes. Still observing slight amount of condensation on condensate drain line. Insulated drain line to ensure no condensation drips outside the drain pan. Unit in good working order upon departure. Thank you for your time.
1. Customer Complaint • Downstairs thermostat showing 85 °F+ despite being set to a normal cooling temperature. • Home felt uncomfortably warm earlier in the day. 2. Remote Monitoring (Pre-visit) 3. On-Site Evaluation • Ambient conditions on arrival (4:00 PM): Downstairs zone now over-cooling (≈ 68 °F). • No error codes or lock-outs on air-handler or condenser. • Visual inspection of equipment and airflow showed normal operation. • Conclusion: Mechanical components healthy. Focus shifted to controls/software. 4. Diagnostic Findings • Accessed thermostat & zoning controller via 360 App from attic junction. • System Event Log: Automatic firmware update recorded at 04:12 pm, July 3 2025. • Post-update, thermostat’s internal temperature reading drifted ≈ 10 °F higher than actual room temperature, confusing the control algorithm (caused prolonged cooling call, then overshoot). • Confirmed anomaly with calibrated digital thermometer at thermostat location. 5. Corrective Action
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters Customer complained that ac was not keeping up without turning the system down past where they wanted the set point. Found duct separated from boot along with evidence of rodent droppings and chewed up ducts. Left estimate for duct repair. As a courtesy I sealed the hole around the line set wi

