Menu

Heating and Air Conditioning Services in McKinney, TX

McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.

Schedule ServiceCall (903) 482-4900

HVAC Services We Offer in McKinney

We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:

Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.

We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.

Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.

We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.

We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.

The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.

Serving All of McKinney

We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.

Schedule Service in McKinneyCall (903) 482-4900

Frequently Asked Questions

How much does AC repair cost in McKinney, TX?

Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in McKinney?

Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.

What HVAC brands do you service in McKinney?

We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in McKinney?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.

What areas of McKinney do you serve?

We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.

Schedule HVAC Service in McKinney Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in McKinneyCall (903) 482-4900

Recent Jobs and Reviews in McKinney, TX

Rated 4.9 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

McKinney, TX at a glance

Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between January 2025 and March 2025.

The most recent job was on March 31, 2025.

Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.

Job Locations and Reviews

Shelby S.
Shelby S. Checked in
Customer system was showing a constant delay at the thermostat. I went into the attic and jumped the unit in to cooling. This caused the low voltage fuse to pop. I proceeded to go outside and find a shorted contactor. Also, I observed that the system has some wires burning, the compressor sounds awful on start up, and the condenser fins has debris in it. I provided pricing for all repairs. CONTACTOR * 1 POLE 25 - 30 AMP 24V CONTACTORS ARE SWITCHES THAT USE HIGH VOLTAGE TO HELP COMPONENTS IN YOUR UNIT. SINCE THEY ARE IN CONSTANT USE, THEY DO NEED TO BE REPLACED OCCASIONALLY.
McKinney, TX 75071
Jacob P.
Jacob P. Checked in
I arrived to our clients home for unit not cooling properly. Derek stated that the unit was struggling to cool the home and reach desired set point. He also mentioned a water spot in the ceiling that had previously been addressed. I first proceeded into the attic and verified that the drain pan and primary drain line were clean and clear of any moisture. I did however find a wet spot in the attic insulation behind the unit about 4 feet and directly below the attic bird cage vent. I then proceeded outside and found the heat pump to be in a full lockout. This was restricting the unit o come on at all as a safety. I reset the compressor but I tested the electrical components and found the capacitors to be failing. They are extremely below manufacture specifications. I also found the coils to the outdoor unit to be dirty and full of dust. The indoor blower motor also has dust accumulated on it and the motor is exceeding the max amps from the manufacturer. I showed all my finding to our
McKinney, TX 75072
Shelby S.
Shelby S. Checked in
Performed single system cooling maintenance. I checked amps, capacitor, filter, electrical, drains, cleanliness, and safeties. The system is performing inside of manufacture specifications. I recommended that a chemical cleaning be done on the outdoor unit, a drain treatment be performed, addition float switch for added protection, and more insulation be installed. I provided pricing for recommended safeties/repairs. Performed drain treatment during time of service. Total-C is a water soluble formulation, containing ingredients that produce a pleasant, fresh citrus scent and sludge eating bacteria, which eliminates the source of the odors and keeps your drains smelling fresh. A small amount goes a long way toward maintaining an odor free atmosphere that you and your family will appreciate!
McKinney, TX 75071
Shelby S.
Shelby S. Checked in
Performed single system cooling maintenance. I checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. System is performing mostly within manufacture specifications. I spoke with the home owner about the possible need of duct cleaning in the coming years. Also, we had a discussion about the hard start kit and what happens if the compressor over amps on start up for too long. The customer spoke about some allergy issues that his wife has and I provided options for u/v lights. I am concerned that the ApcoX will not even fit due to du t placement. Customer would like to speak with his spouse about the offered services.
McKinney, TX 75071
Cesar O.
Cesar O. Checked in
Performed a 1 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures were. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel,,, both are dirty, recommended a blower cleaning. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 1. Washed condenser unit. Old carrier unit is drawing 18 amps on the compressor and 10 amps on the blower motor,, highly recommend a hard start kit
McKinney, TX 75069
Cesar O.
Cesar O. Checked in
Performed a 2 system spring maintenance ( gas). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures were. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. 1. Washed condenser unit.
McKinney, TX 75070
Jacob P.
Jacob P. Checked in
Arrived at home for humidifier not working properly in the master bedroom area. I insured that the thermostat was set properly with humidifier settings and set points. I proceeded upstairs and found the float switch to be wet as if previously engaged. I ensured the low-voltage wires were connected and sending the correct signal. I was able to bypass the water safety switch and insured that the unit was receiving power. I Found the control board to be burnt and not sending the correct signal to initiate the steam humidifier. We will need to replace the board before further testing. I also spoke with our client of how multiple safety interruptions to the board could actually cause this issue to happen and burn the board. I am also including a blow out valve and drain clearing to help prevent this problem from happening again. The upstairs unit did not have the humidifier programmed and once we established the correct program on the thermostat we tested it t9 ensure it was working proper
McKinney, TX 75072
Cesar O.
Cesar O. Checked in
Performed a 1 system spring maintenance ( heat pump). Tasks performed. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked refrigerant pressures were. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential . 15. Inspected drain lines. System is working properly at this time, found no issues. Talked to customer about maintenance agreement renewal, power surge, she agreed to send her estimates for recommendations.
McKinney, TX 75072
Shelby S.
Shelby S. Checked in
Performed single system cooling maintenance. I checked amps, capacitor, refrigerant, cleanliness, electrical connections, and electrical components. The system is cooling to manufacture specifications with some recommendations. Recommendations 1. The outdoor unit has some build up that requires chemicals to assist in removal. A dirty condenser coil causes the system to not cool properly because the system can not efficiently expel the heat. 2. The drain needs to be prepared for cooling season. A drain treatment is recommended to ensure a nice clean drain.
McKinney, TX 75069
Jacob P.
Jacob P. Checked in
Relocation of steam humidifier closer to plenum box includes - extending electrical wire - securing humidifier to new brace - adjusting hose length to new supply plenum Finished installing zone control board and remainder thermostats. Also our Client elected not to have thermostat back plates installed with corresponding thermostats. Also today we went system by system and took all measurements from supply vents before and after making airflow adjustments to our client satisfaction. He is aware that included with today’s visit is one courtesy follow up visit to make any additional adjustments. We did also discuss adding additional return air for certain rooms/areas in the home to help with overall comfort. Our client is happy with completed work and will run his units for about 4 to 6 weeks to accurately assess adjustments made today.
McKinney, TX 75072
Jesse V.
Jesse V. Checked in
Diagnostic Report Issue: • Compressor making noise on the heat pump outdoor unit. Action Taken: 1. Contacted Trane Tech Support: • Advised to reduce the RPMs on the heating side of the heat pump outdoor unit. 2. Adjustments Made: • Adjusted the controller outside to lower the RPMs to a medium setting. 3. Inspection and Findings: • During the check-up, Braden found the air filter was dirty. • Offered to clean the filter, but the customer opted to have her husband do it. • Tech support mentioned that a dirty filter could contribute to the compressor noise due to airflow restrictions. • Observed significant oxidation buildup on the condenser. The condenser requires a chemical washing to remove the oxidation and improve efficiency. 4. System Testing and Results: • Program adjustments were made to slow down the RPMs on the heat pump side. • Test ran the system in heat pump mode to confirm the noise reduction. • Confirmed that the system was functioning well with the new sett
McKinney, TX 75071
Shelby S.
Shelby S. Checked in
Point of contact left before we arrived. The office needs a return added to it. Since it’s now sealed off it is pressurizing and not allowing it to cool properly. The back room there is no supply inside of that room. We need to add a return to the office and a supply to the back room to try and balance the air flow. Requesting pricing due to it being commercial.
McKinney, TX 75070
Jacob P.
Jacob P. Checked in
Trane Thermostat Warranty Trane 10 Year Warranty 1- year labor warranty Includes wiring indoor equipment, outdoor equipment and new thermostat as well as testing to ensure proper function. Installed new thermostats and sensors in almost every room. Will be returning on Monday to complete the upstairs 2 zone wiring as well as preform the air balancing for the entire home.
McKinney, TX 75072
Jacob P.
Jacob P. Checked in
We arrived today for a 5 system heat maintenance inspection. Our client had recently replaced the air filters in his home and did not need them Changed today. We cleaned every pressure switch port, flame sensor and furnace cabinets for each unit. We also tested and ensured the fire shutoff safeties were all working properly. We found that all 3 April air steam humidifiers needed the canisters to be replaced. Our client will order and purchase his own new canisters. I also proceeded to correct the thermostat/sensor issue for the downstairs guest bedroom. I began by shutting the furnace and thermostat off and on power up the sensors automatically were connected. I changed the peak monitoring setting to default setting and adjusted the minimum set point to 68° this should prevent the guest bedroom from getting too cold if the sensors drop off from the thermostat. If this doesn’t work our client has expressed interest in changing the thermostat back to trane with new wireless trane senso
McKinney, TX 75072
James M.
James M. Checked in
Performed an operational inspection of heat pump system, and found compressor vibrating excessively. The vibrations travel through the line set causing periodic noise in the upstairs bedroom. We attempted to readjust and strap the line set in the attic to reduce vibrations but were unable to resolve the issue. We must consult with Trane Tech Support to see if it is possible to minimize the excessive vibrations from the compressor. Homeowner has been briefed on issues and our attempt to reach Trane for a way forward regarding repairs.
McKinney, TX 75071
Jacob P.
Jacob P. Checked in
Arrived to clients home for unit not heating. Client stated he had cleaned the flame sensor himself and also replaced the hot surface igniter with no success. I immediately informed him of the potential failures before proceeding into the attic. I diagnosed a failed gas valve that was not opening on demand. I gave our client 2 options to replace the gas valve with our without the maintenance plan included he elected to replace the valve only today. Once replaced I tested to ensure it was heating properly and ensured the fire shutoffs are working. The unit is heating on departure.
McKinney, TX 75071
Shelby S.
Shelby S. Checked in
Performed single system heating maintenance on a 2017 zoned gas furnace. I checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. The system is heating to manufacture specifications but I have some major concerns about the system. Recommendations 1. The emergency pan is heavily rusted and is forming calcium deposits on the bottom of the pan. It is advised to replace it before cooling season comes back around because of a major risk of water damage. 2. The blower motor is matted with dust and making a strange noise during start up. I advise a cleaning before this motor fails due to excessive stress. 3. The ducts are caked in dust. This causes the customer to have to change their filter more frequently, the rest of the system to become filthy, and will make major parts failure. Example: compressor, evaporator coil, and blower motor. 4. I found the filter fully blocked causing the filter to collapse.
McKinney, TX 75071
Shelby S.
Shelby S. Checked in
Performed 2 system heating maintenance. I checked amps, capacitors, filters, refrigerant, electrical, cleanliness, drains, and safeties. System is performing to manufacture specifications. Recommendations 1. I recommend duct cleaning be performed on the downstairs system due to high amount of dust present. This can reduce the chance of the blower motor and evaporator coil from becoming overly dirty which would result in premature failures. 2. The upstairs system is pulling too many amps during start up. This causes long term damage to the compressor and capacitor resulting in premature failure. 3. Suggest performing drain treatment on both systems to prepare them for cooling season.
McKinney, TX 75071
Jacob P.
Jacob P. Checked in
I arrived at our clients home for a 2 system heat maintenance inspection. Our client provided air filters to be replaced today. Once replaced I proceeded to clean the flame sensors and pressure switch ports for both units. I tested the amp draw for both the inducer and blower motors for each furnace. The downstairs blower motor had dust accumulated on it but also has visible signs of oil coming from the casing. The capacitor is below manufacture specifications and the motor is pulling very high amps. I showed this to our client and he wished to wait unit complete failure before replacing. This unit is connected to the larger and older condenser unit outside. There are also resistors on the downstairs control board that have experienced overload and have visible damage on the board from potential surges in power. We did discuss surge protection but our client was not interested in them today. I did also test and ensure the fire shutoff safeties were working for both furnaces. Everythi
McKinney, TX 75069
Shelby S.
Shelby S. Checked in
Performed single system heating maintenance on a 2017 zoned heat pump. I checked amps, capacitors, filter, electrical, refrigerant, cleanliness, and safeties. The system is heating with some concerns. Recommendations 1. Capacitor 40/5 on the outside unit is reading weak (33/40) on the compressor side. With the current reading, I can not guarantee the system will continue to start. 2. The defrost board in the outside unit has begun to burn at the resistors. This will cause the board to eventually short out. The timeline for this to happen varies. 3. The blower wheel has a build up of dust. This results in the blower motor to work harder to move the air through the house and can cause premature failure. 4. The return cavity has excessive dust inside of it and will make he filter become dirty faster and this could restrict airflow if left unaddressed. 5. The evaporator coil has dust deposits forming between the fins. This is going to restrict airflow causing stress on all major
McKinney, TX 75071
Alex G.
Alex G. Checked in
Upon arrival, spoke with homeowner about unique, smell coming from unit upstairs slightly described as a gas smell not so much as a musty, dirty sock syndrome. Smell went to the attic and opened up the system to take a look at the evaporator core blower motor and all components inside the unit. There’s a light layer of debris on evaporator coil almost has a yellow tint to it. Kind of similar to calcium buildup blower motor. Housing has a little condensation accumulated at one point. Wipe down blower motor housing from calcium buildup caused by condensation. Recommending ultraviolet air filtration system to prevent any possible future bacteria, growth, & help improve overall air quality inside the home by eliminating any bacteria from entering the system and pushed into the home while slightly reducing dust particles entering the system and helping reduce what described as a dirty sock syndrome smells. Also recommended a light coil clean to immediately cut down smells such as dirty
McKinney, TX 75071
Shelby S.
Shelby S. Checked in
We arrived at our client home for a 4 system heat maintenance inspection. Our client provided filters to be replaced on all 4 units. Once replaced we proceeded to test and check the furnace and clean the necessary components. We also tested and ensured the fire shutoff safeties were all working properly. We did find that the unit labeled “media room” had a blower motor that is failing and leaking oil from the motor. This unit is not used at all since the clients have done extensive remodeling in the home. Because of how the home is now designed they leave the unit off in the winter time and our clients are unsure of the total usage in the summer. They still have more remodeling work to do in the home and want to complete the work before they proceed to do any duct cleaning or duct design work. We did discuss the amount of dust that had accumulated in the ductwork and we are recommending a full duct cleaning to clean the ducts, the motors and the coils from all the drywall dust that h
McKinney, TX 75072
Jacob P.
Jacob P. Checked in
Preformed single system maintenance today. Client had filter which I replaced. Once replaced I proceeded to test and inspect the furnace and fire shutoff safeties. Everything tested in range and passed inspection. I did take time to discuss with our client the importance of a float switch and also blow out valve. This is due to the previous repair completed and the unit currently without a water shutoff sensor. I did create and send this estimate to our client. The unit is running properly on departure.
McKinney, TX 75071
Alex G.
Alex G. Checked in
Preformed routine maintenance a 2022 gas furnace. This operates the downstairs unit is. 2 return filter grills or 25 x 25 x 1“. Everything is operating as it should recommended an ultraviolet light for up and downstairs to help reduce dust and debris. Buildup in allergen in the air brought them outside. Also recommended spring and fall maintenance is for both units. Homeowner declined and said she would just call in the summer.
McKinney, TX 75072
Jacob P.
Jacob P. Checked in
Returned today to install replacement zone damper motors. Once replaced I began to test and inspect both upstairs and downstairs zones. I ensured that the bypass damper was also set properly and allowing air to flow through and not create too much residual pressure on the motors. Once I completed testing I showed our client pictures and video of the work performed. I told our client to continue to monitor heat and airflow for upstairs and we would return to preform the Maintenance on the equipment on a later day. The unit is running properly on departure.
McKinney, TX 75070

Your High Efficiency

Experts