McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between December 2024 and January 2025.
The most recent job was on January 21, 2025.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
I arrived at our clients home for a 2 system maintenance inspection. Our client did have replacement filters for both units. These are the last filters and our client will purchase new ones. After replacing the filters I proceeded to test and inspect both units. I began by cleaning the flame sensors and pressure switch ports for both furnaces. I then tested to ensure the fire shutoff safeties worked. Everything passed today’s inspection. I did find both upstairs and Downstairs units to have excessive dust accumulated in the return plenums and ductwork. I showed this to our client and we discussed how this is most likely residual construction dust from the new home. I proceeded to create an estimate for the duct cleaning service to remove the dust from both units and keep them working properly. I also found that the drain pan for the downstairs unit is compromised and has a small rust spot on the external side of the pan and a water spot on the attic floor. We discussed sealing the d
I arrived at our clients home for a 2 system heat maintenance inspection. Our client had recently replaced his air filters and did not need them changed today. I began with the downstairs unit but tested both furnace inducer motor amps. Clean the flame sensors and tested the fire shutoff safeties. Everything passed inspection today. Our client units are still very clean and we discussed replacing the air filters consistently. We did discuss the previous drain line work that had been preformed and discussed using white vinegar to help continue and maintain the drain line clear. Both units are running properly and ready for remainder of winter.
I arrived at our clients home for a single system heat pump maintenance. Our client had recently replaced the air filter and did not need it changed today. I began outside and ensured the heat pump electronics were all testing in range. I did find the compressor start amps to be higher than recommended on the manufacture plate. I showed this to our client and we discussed the importance of surge protection and a hard start kit to keep the start amps in normal range. Inside I tested the emergency heat and tested the blower motor. Everything else passed inspection today. I also did ask our client regarding the second unit for the shop. They did not want me to check it out today.
Arrived at our clients home to install 2 Lennox room temperature sensors. We first disconnected and removed the existing sensors from the home. Once removed we proceeded to connect and name each sensor separately. We left both sensors in the same guest bedroom downstairs and our client will monitor the operation and performance of the unit. We also discussed the maintenance and air balancing that is still needing to be done in the home. The sensors are installed and displaying properly on our clients app on departure.
Arrived at home for clients concerns that the heat pump was not working correctly. I proceeded to the downstairs thermostat and put it in test checkout heating mode. Specifically to test the variable speed heat pump. I ran the downstairs heat at 99% capacity for more than 40 mins without any issues of noise or cooling from the supply vents. I than found the downstairs zone damper to be set lower than the upstairs zone. Jesse and I spoke on the phone and increased the setting of the downstairs zone to a higher capacity. This will allow the system compressor to run at a higher capacity. I also discussed how the heat pump will turn on the furnace/emergency heat in defrost mode and also when outdoor temps are below freezing specifically 25°. We ran the unit in heat again with the set point at 75° and the home was already 72°. The outdoor compressor only went to 63% of max capacity. We discussed also air filter cleaning and the pack uv. Bulb. Our client would like for me to come back out
Performed 2 system heating maintenance. Checked amps, filter, electrical, cleanliness, drains ,and safeties. Systems are performing to manufacture specifications. Recommendations 1. Adding water protection to the main unit in case a clog occurs to try and prevent water damage. 2. Mini split does not have surge protection. If a power surge was to happen, there is potential of ruining the control boards.
Performed single system heating maintenance. Checked amps, filter, electrical, cleanliness, drains, and safeties. System is heating well and mostly inside of manufacturing specs. Recommendations 1. Blower has dust build up. This causes the motor to have to work harder and can cause premature failure. 2. The inducer motor is over amping. This is an early sign that the inducer motor is failing. It is advised to replaced the inducer motor.
Diagnosed 2 failed damper motors for both up and downstairs zones. I ensured I was getting proper voltage from the zone control board. I explained my findings to our client and we discussed repair options. We also discussed maintenance for his equipment. I created 2 estimates so that he is able to discuss with his wife before moving forward.
Performed 3 system heating maintenance. Checked amps, capacitors, filters, cleanliness, drains, and safeties. Systems are heating to manufacture specifications. Recommendations 1. I suggest upgrading filters due to the huge gaps in the filter box. This is the help maintain a clean system and reduce the possibility of having to clean the blowers and ducts sooner. 2. To help maintain a clean system I suggest we add u/v lights.
Returned to home for sensors not properly commanding unit to turn on and run. Client explained he shut off unit from furnace. Replaced batteries. And reconnected sensors to the thermostat. After multiple attempts on Saturday he was finally able to link the sensors to the thermostat. I explained that I was planning on doing the same procedure. But that the intermittent issues was most likely a precursor to complete failure. They agreed to replace the sensors under warranty. We also discussed airflow issues throughout the home and our client want to move forward with scheduling a complete air balance per unit for the entire home.
Performed system maintenance on a Perform system maintenance on 2015 Lennox Gas system. Everything running as it should upon arrival and departure spoke with homeowner about allergies in the home he said both. Him and his wife have an issue with them. Recommended UV air filtration system. We had a discussion about the UV light works inside the system to kill any Bacteria and allergens brought in from outside the home. Checked amp draw on indoor unit and outdoor unit both within manufacturer specs outdoor capacitor was just recently changed In 2024
I arrived at our clients home for one of the units not heating properly. Our client made an adjustment to the thermostat and through the night the unit failed to heat the desired space. The client had reset the temperature sensors for the thermostat and the unit was currently heating properly with no errors or issues present. Our client and I also discussed concerns to achieve a desired humidity level in the home. The current unit has a steam humidifier with a T in line with the supply plenum that should be rerouted. We also discussed indoor air quality in the home and duct cleaning to help remove the dirty sock syndrome they have in the home also. I have created an estimate for maintenance plan And will also create an estimate for air balancing. They would like to hold off on the duct cleaning for now.
Performed courtesy check up on front 4 ton package unit on roof rooftop unit is operating upon arrival and departure. Noticed unit pulling a high amount of amps at disconnect. Reason being the unit itself is working twice as hard to push and pull. It’s normal operating components under stress due to bacteria and dust buildup accumulated inside the evaporator coil, blower motor and blower motor housing, as well as condensing coil. Recommending a level two evaporator chemical clean as well as a level two condenser chemical, clean as Trane has a sophisticated one of a kind Coil fin system layout that helps your unit, transfer heat and or cooling faster and more efficiently. Unfortunately, with that one of a kind system, it tends to collect more debris in the tighter hard to reach places. Also found condensing fan motor & indoor Blower motor under the 6% manufacturer recommends replacing. Blower motor capacitor rated for 20mfd, reading at 18.09mfd. Condenser fan motor rated for 7.5mfd.
I arrived to replace outdoor sensor on the variable speed heat pump. Once replaced I proceeded to use the thermostat and test the unit in heat mode using the outdoor unit only. I let the unit run for 20 min and asked our client to listen for any repeat rattling noise from inside the master bedroom. Our client could not hear the noise at all while the unit was running. We discussed running emergency heat when temperatures are below freezing. And our client was happy noise was no longer being heard in the home. System running properly on departure
Upon arrival, condensing unit slightly frozen, with debris buildup around condensing coil, not allowing proper airflow across coil, causing to compressor and motor to operate and continuously work hard harder. Down capacitor on outdoor unit below manufacturer spec for change out recommend replacing with a turbo 200 capacitor. Compressor and fan motor struggling to start. Recommend a hard start kit to help jumpstart the initial start of the unit. Upon visual inspection of indoor unit found 20 x 20 x 1” filter hasn’t been replaced since 8/24/24. It 1 inch filter should be replaced every month debris buildup on filter after removing filter filter. Unit started to heat a little bit check evaporator coil noticed half the coil is clogged full of debris not allowing unit to heat or cool properly recommend in place level two chemical clean for evaporator coil. Temperature is too low to determine Freon levels needing to clean system first with level two coil cleanings inside and out, replace
Zone damper for the upstairs is stuck open causing the upstairs to become overheated.
Performed single system heating maintenance on a 2013 zoned furnace. Checked amps, filter, electrical,drains, cleanliness, and safeties. System is heating to manufacture specifications. Recommendations 1. Upstairs is getting over heated due to a failed zone damper not closing when voltage is applied. 2. The system currently does not have a water safety switch. Without this switch, there is a higher chance of water damage happening when a clog occurs.
Installed 2 stage gas valve and LP kit. Tested the unit and it is now heating.
Performed single system heating maintenance. Checked amps, capacitor, filter, electrical, cleanliness, and safeties. System is performing to manufacture specifications. Recommendation 1. Performing a drain treatment to ensure nothing is building up in the drain so it’s ready for spring.
It is not making it through the proving phase of start up. The inducer will close both pressure switches to ensure proper operation. The low switch is closing but the high is not. System will attempt to light now after installing a new pressure switch but the gas valve appears to not be opening. Will need to order gas valve and return.
Don’t contractor malfunction from manufacture, placed contactor unit is up and running as it should
Found 2 stage pressure switch to be bad and not closing its contacts. I provided pricing to replace it. The system will not attempt to light.
Upon arrival, we replaced the 60 amp circuit breaker with a 50 amp circuit breaker bringing the heat pump and install within code. Due to a mild build up on the air filters and heat pump, a mild maintenance was performed to ensure optimum conditions for the HVAC system. The homeowner was also briefed that the zone thermostat must be on the same settings versus the auto option on the thermostat. This will cause alert codes due to the system trying to heat and cool at the same time. The homeowner also stated there was a noise coming from the wall on the upstairs bedrooms on the south side of the home. It is in the same location as the line set running from the heat pump to the HVAC system in the attic. The sound wasn't present at the time of the visit but there is a need to return with another technician to investigate the source of the problem. There is potential vibration coming from the line set against the structure of the home. Slight adjustments over the garage may rectify the issu
Performed 3 system heating maintenance. Checked amps, capacitor, filters, cleanliness, electrical, and safeties. The 3rd system is labeled 130 on the roof. Systems are heating to manufacture specifications Recommendations 1. All 3 systems need filters and I have provided pricing to get all of them replaced. 2. The system that is located on the front side of the building needs blower wheel cleaning and its return box cleaned. I was able to provide a price for the blower wheel but will have to request pricing to do the other cleaning from my manager.
Unit has power and call for heating power at fan motor at 24 volts to module but not movement. Fan motor needs to be replaced. Fan motor is X13 FM19. 1/2 HP 208/230vac Replace blower motor tested unit to make sure it’s fully operational. Unit is running as it should at this time. Motor is dead, getting voltage to the motor as motors not responding needs to be replaced