McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between December 2025 and February 2026.
The most recent job was on February 26, 2026.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
Upon arrival, I turned the system on in the cooling mode. I observed that the system is fully turned on and was operational. I performed some general observation before retrieving my tools. The refrigerant line was not getting cold and the air coming out of the top of the outdoor unit was cool. I retrieved my tools and proceeded to check the refrigerant pressures. The refrigerant pressure was good, but was not pumping through the system. I took a video of the issue indicating the compressor was on, but not pumping the refrigerant. I had the warranty searched and determined that the warranty expired in 2023. With that being said, the EPA has effectively phased out the refrigerant that this system uses. This unit is no longer repairable. Jesse, our comfort specialist, is scheduled to come out 2/27/2026 at 9:30am.
2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages 16. Rinsed condenser unit to promote heat exchange Found condenser outside entirely plugged with dust and debris all the way around. Also found good amount of dust on the blower wheel this indicates that at least this much dust has made it past the filter and onto the evaporator coil. Advised homeowner that both coils would need to be cleaning in order to maintain efficien
Preformed single system heating maintenance on a 2025 gas furnace. I tested all electrical components and safeties. All tested within manufacturer specifications. I checked for cleanliness of the duct work and blower wheel. I found the return ducts to be covered in dust. I checked he filter it did not need to be changed at the time of inspection. I then proceeded to the outside unit where I visually inspected the unit. All was in good working order. The unit was cooling upon departure.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Found large amount of dust on blower wheel. This will cause drag on the motor, causing it to work harder and ultimately overtime shortening the lifespan of the motor itself. Upon investigation of the filter, I found that the filter was not fitting properly into the filter box. I measured the filter box and
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Found outdoor condenser blanketed in debris and dust. This causes undue stress on the compressor and all connected components. I would highly recommend having the coils cleaned in order to keep this unit alive as long as possible. I also noticed there’s no float switch on this unit. This can cause water t
Arrived on site for no heat. Customer was having issue operations the thermostat. She stated that thermostat would need to be set again and again after going to sleep. Performed check over entirety of system and found no issues that would cause system to not run as intended. Noticed very large blanket of dust and debris on outside condenser coil. This will cause undue stress on the system and lead it into an early grave If it is allowed to continue like this. Provided options for getting this issue addressed including chemically cleaning indoor and outdoor coils, and blower wheel as well as a duct cleaning. This will improve air quality inside and prolong life of system. I also noticed there was no float switch on the indoor unit. This can cause water to come through the ceiling if the primary drain line is blocked. Discussed thermostat programming and how to set a manual hold with the homeowner. Unit in good working order upon departure.
Upon arrival, I found the thermostat blank. I went into the attic and discovered no power in the furnace. I proceeded to the main electrical panel and located a tripped breaker. I reset it and found that the switch in the attic was off. I turned it on and got power back in the unit. Customer needs to replace 16x25x4 filter. I cycled the heating 2 times and ensured it was going to work and satisfy the temperature demand. Customer is unaware of when the issue happened. From what I can deduce, is that the flue likely got blocked by ice and tripped the system. System is heating inside of manufacture specifications upon departure.
Preformed duct cleaning estimate. Showed client before and after pictures and walked him through the process for each system. Client would like to speak to his wife about the estimates.
I performed a single heating maintenance on a 2017 zoned gas system. I checked amps, filter, electrical, cleanliness, zoning, and safeties. Before I got started, the customer mentioned that it seems like the downstairs is not heating. I investigated this concern to the best of my ability. I verified that the zoning is working properly for the upstairs and downstairs. When I was running the system with both zones on in heating, I discovered that the system is producing extremely hot air. I checked the ducts for appropriate design. I discovered that the system does not have enough return air. It currently only has approximately a 18in duct. The bypass is opening with both zones running. The unit is full of dust and debris. This is likely playing a role in the unit tripping on a thermal cut out. I advise a complete cleaning be done on the system at the least. I will get with my supervisor about a possible work around for the poor duct design.
I performed 2 heating maintenances on 2015 90% gas systems. I checked amps, filters, electrical, drains, cleanliness, and safeties. During my evaluation, I discovered that the system for the main part of the house has a failing capacitor on the inducer motor. This will cause the unit to stop heating when it fully goes out. I noticed that the equipment does not have surge protection, and I advise performing a drain treatment to ensure the drains are good because 90% gas systems produce water when heating.
Upon arrival, I discovered that the door was off the unit. These door go on a specific way. I installed the door back on and tested the system. The system is back to heating properly. I emailed the dispatch to the supplied email.
I performed a single heating maintenance on a 2016 carrier gas system. I checked amps, cleanliness, electrical, and safeties. Also, I cleaned the inside of the outdoor panel and resealed a duct. I discovered that the system is full of dust. The number one root cause of system failure is dust. I showed the customer videos and provided solutions to extend the life of the system. Customer stated that he would want to wait until spring to address these issues.
Upon arrival customer stated the heat wasn’t reaching temperature. I placed a call for heat and proceeded to the outside unit as this is a heat pump. I noticed the fan or compressor weren’t running. I tested all electrical components and found that the capacitor was not within manufacturer specifications and was bad. I used my test capacitor to see if the unit would come on. The condenser fan came on but the compressor was humming and trying to start but never would. I then ohm’d out the compressor and it wasn’t reading within manufacturer specifications. The readings were telling me that it was locked up. I talked to the customer about the concerns and provided estimates to have the compressor replaced and capacitor, along with the refrigerant and filter drier for the system. Customer would like to speak to his wife and he will contact us back. Unit will heat in emergency heat mode but will not work in cool or heat mode.
Performed a complete heating system maintenance and inspection. 3 system gas. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Verified system temperatures: return air temperature measured at 76°F; supply air temperature measured at 110°F and rising. Confirmed air filter was recently replaced by client; filter size is Aprilaire 813 Inspected and tested all electrical components on the outdoor unit; all components tested within manufacturer specifications. I did notice the den unit and master bed unit both could benefit from having ducts cleaned and blower wheels cleaned. Also spoke to the client about having the outdoor temp sensor changed under parts and labor. The sensor has failed. Also the client brought up that the filter drier is really rusty and would like a quote on getting it changed out. I provided estimates for all cleanings and repairs needed. Confirmed system was
Thermostat was set to a temporary hold after having a power surge. The power outage caused the thermostat to reset itself. I reprogrammed the thermostat and showed he client how to take the temporary hold off if it happened again.
I performed a 3 system gas heating maintenance. Units 1 and 2 are from 2020 and unit 3 is from 2019. I checked amps, capacitors, filters, cleanliness, electrical, and safeties. I observed that the belts for the blower motors are becoming worn and loose. I advise replacing these belts before failure occurs. All of the units need their filters replaced. I noticed that the returns of all of the systems are completely filthy. This is going to reduce the air quality, cause the filters to get dirty faster, and end result is unnecessary straining on the system.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Rinsed condenser coils to promote heat exchange Found rust around inducer pressure port on inducer housing. I did not find any further signs that water was making it down the flue pipe. I believe that the bad seal on the pressure port is causing a temperature difference and therefore condensation around the pressure port. Video included of wiggling pressure port. Aside from that unit in good wor
I performed a 2 system heating maintenance on gas systems. Zoned communicating Amana- furnace 2020 - condenser 2024 Trane - Furnace 2020 - condenser 2016 I checked amps, capacitors, filters, electrical, cleanliness, temperature split, and safeties. Systems are heating inside of manufacture specifications. Customer mentioned some uneven cooling/heating in areas of the home. I investigated into the matter. I found the source of the issue. There is a single duct that splits 3 ways to the rooms in question. To properly address this issue, we would need to redesign to ducting system. I observed that the filters don’t fully seal in the filter cabinet. This causes dust to bypass into the system and making components dirty and strain. I advise that the filter cabinet be upgraded to allow a filter that will perfectly fit. The units do not have surge protection and risk damage if power fluctuates. Customer approved work to be performed and prefers after Christmas. Collected in full for the wor
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Inspected / cleaned return filter. 6. Inspected evaporator coil. Clean 7. Inspected blower motor/ blower wheel. 8. Checked blower amp draw. 9. Measured temperature differential from supply to return. 110 supply 74 return measured. 10. Rinsed condenser unit to promote heat exchange Perform dryer vent cleaning and showed pictures of finished product and before pictures to customer. Unit in good working order at this time.
I performed a single system heating maintenance on a 2018 zoned gas system. I checked zoning, amps, filter, electrical, air quality, cleanliness, and safeties. I verified that the system is heating well. I did notice some issues arising. The blower motor bearings are worn and allowing play in the motor shaft. The will lead to the motor becoming inoperable. The transformer that gives power to the zoning board is running extremely hot and humming loudly. These signs are known to indicate a transformer on its last leg. I brought to the attention of the customer that his current filter set up is allowing dust to bypass the filter. We spoke about upgrading the filtration of the home. Customer had to leave before presenting options. I reach out to Lennox to price the blower motor.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 15. Rinsed condenser unit to promote heat exchange Raised concerns to Annette about absence of sediment traps on 3 of the units. #2 was the only unit with a sediment trap. Also informed customer that blower wheels on all 4 units were looking extremely dusty and dirty. This creates drag on the motor cauing the motor to work harder and ultimately shortening the lifespan of the motor. Units are heating
I performed a single heating maintenance on a 2015 zoned gas system. I checked amps, cleanliness, electrical, filter, and safeties. I observed that the blower is beginning to have build up, the system does not have a primary drain safety switch or surge protection, and the outdoor unit is in need of a deep cleaning. I provided options to address these areas, and the customer declined at the time of service. Customer wants to wait unit after the new year to proceed. We owe an air quality check on the cooling visit due to the machine not finding service.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Found reme halo bulb burned out. Homeowner signed off on replacment bulb. Informed homeowner that we would get this ordered and then coordinate a good day to replace the bulb. Also found a substantial amount of buildup on the blower wheel. This creates drag on the motor and overtime
Arrived on site for no heat call. Assisted homeowner in operating Trane thermostat for other unit that was not having issues. Homeowner stated thermostat had turned off and was unresponsive. Upon inspecting the thermostat I found it was powered on and seem to be cooling. I then tested the drain line with a gallon of water and found no blockage. Upon taking a temperature split I noticed I was only getting about a 10° difference. And then went outside and verified refrigerant pressures and found the low side testing around 60 to 70 psi and high side around 200. I removed the very dirty filter from the unit and instantly measured a 20° split upon checking pressures. I found 110 on the low side and around 200 on the high side. I then tested zone one damper for the upstairs and zone two for the downstairs and found no issues. Advised homeowner to replace filters every month. Unit in good working order upon departure.
Upon arrival, I found the unit tripped on a roll out. After further investigation, I noticed that the burner log was not lined up quietly right. I adjusted and corrected the noticed issue. I watched the unit for a while before calling it good. System is heating upon departure.