McKinney summers are long, and the heat is serious. When your AC stops working in July, you need someone who can actually show up the same day, not schedule you out a week. Adon Complete Air Conditioning and Heating has been serving McKinney homeowners for years from our home base in Anna, just up the road. Our owner, Jesse Villarreal, has over 27 years of HVAC experience, and our technicians, Shelby, Brayden, Matthew, and the rest of the team, are working in McKinney neighborhoods every single day. We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies.
HVAC Services We Offer in McKinney
We handle everything heating and cooling for McKinney homeowners and businesses. Here’s what we do:
- AC Repair. Same-day service available. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.
- AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.
- HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the simplest way to protect your system year-round.
- Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single and multi-zone systems throughout McKinney.
- Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. We install and service all major heat pump brands in McKinney and surrounding Collin County.
- Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for McKinney homeowners.
- Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.
- Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout McKinney and Collin County.
Why McKinney Homeowners Choose Adon Complete

There’s no shortage of HVAC companies serving McKinney. Here’s what makes us different.
We’re local. We’re based in Anna, TX, a few miles up Highway 75. Our technicians drive the roads of McKinney every day and know the neighborhoods, the housing stock, and the HVAC challenges that come with North Texas homes.
Jesse Villarreal has been doing this for over 27 years. He’s the owner and is actively involved in the business. When you call Adon Complete, you’re not calling a franchise or a call center. You’re calling a local company where the owner’s name and reputation are on the line with every job.
We’re a Trane Comfort Specialist and Mitsubishi-authorized dealer. That means factory-trained installation and the full manufacturer warranty on every system we install. Not every HVAC company in McKinney can say that.
We service everything. Whatever brand you have, we can work on it. We don’t turn jobs away because the equipment isn’t ours.
The Adon Care Club is $12 a month. Two tune-ups a year, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency access. It’s the most affordable maintenance plan in the area.
Serving All of McKinney
We service every neighborhood in McKinney, including Craig Ranch, Stonebridge Ranch, Adriatica, Tucker Hill, and Historic Downtown McKinney. Whether you’re in a newer construction home or an older property, we know the area well, and our technicians are out in McKinney neighborhoods every day.
Frequently Asked Questions
How much does AC repair cost in McKinney, TX?
Most AC repairs in McKinney run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or a thermostat issue are on the lower end. More involved repairs, such as a refrigerant recharge or a blower motor replacement, will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.
Do you offer emergency HVAC service in McKinney?
Yes. We offer 24/7 emergency heating and air conditioning service throughout McKinney and Collin County. When you call after hours, you reach a real person who can get a technician to your home fast. We know that a broken AC in McKinney during summer doesn’t wait for business hours.
What HVAC brands do you service in McKinney?
We service all makes and models, including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.
Do you offer HVAC maintenance plans in McKinney?
Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably year-round.
What areas of McKinney do you serve?
We serve all of McKinney and the surrounding Collin County communities, including Allen, Frisco, Melissa, Anna, Celina, and Prosper.
Schedule HVAC Service in McKinney Today
Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before summer hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.
Recent Jobs and Reviews in McKinney, TX
McKinney, TX at a glance
Adon Complete Air Conditioning and Heating has completed 25 jobs in McKinney, TX between October 2025 and December 2025.
The most recent job was on December 5, 2025.
Adon Complete Air Conditioning and Heating has completed 159 jobs in McKinney, TX in the last 12 months. The first job there was in March 2020.
Job Locations and Reviews
Reset the unit due to a power surge. System heating upon departure.
December 3rd, 2025 I returned to install the control board and blower motor. I tested both system after installation and they are both fully functional and heating. I proposed adding surge protection to all units. I emailed the videos, pictures, and invoice. The left downstairs system’s control board is burnt up and not passing voltage. The right down stairs system is having a blower motor issue. When in a call for heat the blower motor does not engage resulting in the high temperature limit switch to become tripped.
Preformed single system heat maintenance on a 2016 heat pump. I tested all electrical components on the air handler inside. I pulled the filter to check cleanliness and noticed it was hard to remove and very snug. Tempture being supplied to the home was at 100 and 70 being returned to the unit. I proceeded outside where I tested all electrical components and start and run amps for the compressor. I found that the capacitor and Contactor were testing lower than manufacturer specifications. Also the compressor was starting high on amps. Over 100 amps. I also noticed the u it didn’t have any surge protection as well. I provided estimates to the clients, they are going to talk it over and figure out what they would like to do.
Upon arrival, I found that the left downstairs unit is receiving power for low voltage and high voltage. There are no lights on lighting up on the board. I just R to W and the system is not doing anything. There is a burn spot present on the board. The downstairs right system was in a limit lock out. I reset the lock out to find the blower is not coming on. I checked my 24v for the speed and my 120v for the motor. The motor is receiving all voltage necessary to operate but is not coming on. The blower motor is on order in Dallas at Carrier and the control board is on order at Century Supply. I emailed the payment link for dispatch and repair work.
Upon arrival client was having trouble with their current thermostat with it resetting itself after so many hours. I explained that it was running on a schedule. The client stated they haven’t ever set a schedule on it and would like to just replace the thermostat. I replaced the thermostat with a T6 pro. Unit was heating upon departure.
Arrived on site for no heat on existing system where only the thermostat was replaced on Saturday. Began system inspection by inspecting all wire connections, and found no issues. Proceeded to test unit heating in test mode. Heating worked without issue in stage one and stage two. i’ve been tested heating organically outside of test mode and noticed unit began a cooling cycle tested Y1 and Y2 two to common and found 24 V while I measured nothing on W1W2. This leads me to believe it is an issue with the thermostat. I then proceeded to review the thermostats programming and found it set up for 2 heat 2 cool gas. Contacted train tech-support and was advised to do a factory reset on the thermostat. Upon conducting the factory reset and reprogramming, the furnace began to heat without issue. Conducted multiple heat cycles and allowed it to run for a while to ensure no safety or sensors tripped. I’ve been proceeded withthe QC on the new system we installed. Came out today for QC visit on ne
I performed a heating maintenance on 2 gas systems. I checked amps, capacitors, filters, electrical, cleanliness, and safeties. Customer and I spoke about allergens and decided airscrubbers would be a good fit for the home. The outdoor units currently have surge protection and the indoor units do not. The flue pipe on the downstairs system is currently not designed properly and could lead to dangerous situations by not allowing the combustion gases to escape properly. The sediment trap on the downstairs system is not designed properly and not removing sediment/moisture out of the gas.
Preformed single system maintenance on a 2022 heat pump. I tested all electrical components inside and checked the heat strips as well. All electrical components and heat strips tested within manufacturer specifications. I changed the filter for the client 20x25x4. I did notice the client did not have a float switch to shut off the unit in case of a clog or a blow out valve to help better assist in removing a clog. I then proceeded outside to check all electrical components and start amps for the compressor. I found that all electrical components tested within manufacturer specifications, but the amps at start up were over 100 amps rated manufacturer limit is 104 amps on start up. I presented all findings to the client. Client elected to have hard start kit, float switch and blow out valve installed. Showed before and after pictures of work completed and showed the start amps of the compressor went from over 100 amps down to 45 amps. Client was also interested in having an estimate lef
Preformed no cool diagnostic. I found that the system has a bad blower motor, also found that the unit is extremely dusty. Offered blower motor replacement and duct cleaning, also considering the age of the unit it is right at 10 years old they elected to have a comfort advisor visit be conducted. They would also like to think about the other repairs. Unit is turned off in the attic space.
Arrived on site, for no heat. Homeowner has been in the home for two years. Homeowner stated blower motor was running Hear the gas running. I began by setting the downstairs thermostat to heat. Upon reviewing the furnace, I found it was not calling for heat on the zone board. I tested the heat directly from the zone board and the furnace completed the heat cycle without issue. I then tested heat on the upstairs thermostat and it also completed the heating cycle without issue. I then wired R and W together on the downstairs thermostat and found that the heating cycle completed without issue leading me to believe that the thermostat is not sending a signal for heating. Advise homeowner upstairs heat is working at this time and provided estimates for thermostat replacement and possible warranty. Homeowner elected to try to replace the thermostat himself and
Arrived on site for heating maintenance on 2021 train furnace. Homeowner stated all was well with regards to normal unit operation. Proceeded with heating maintenance as scheduled. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. Noticed suction line sensor error on the thermostat. I cleaned the sensor and reset the system and the error was still present. I reset the system later on and the error went away. Advised homeowner to monitor for this error
Arrived on site for heating maintenance on 2023 Trane furnace 4T. Homeowner stated all was well with normal system operation to her knowledge. Proceeded with heating maintenance as scheduled. Heatpump- heating 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 15. Rinsed condenser unit to promote heat exchange All was well with normal system operation, however I did notice some evidence of condensation on the unit and found the minimum cfm per ton at
We performed heating maintenance on 2 gas systems. Master bedroom - 2024 Main living - 2022 The main living unit is none communicating and the master unit is communicating. We checked amps, capacitors, cleanliness, electrical, and safeties. We noticed that the units have dust build up present in the duct work. This is likely due to the renovations that the customer has had done. The main living unit has a reasonable amount of dust build up on the wheel. This causes the motor to work harder to perform its normal duties. Also, we noticed that the surge protector on the furnace for the main living has went out. We provided pricing to replace the surge under parts warranty and cleaning of the system. The cleaning option includes a complementary replacement of the warranty surge protector.
Upon arrival spoke with Brennan (GC) at cowboy construction. Brennan stated that he had the damper motor zone board replaced. After this replacement the homeowner stated that there was no heat being provided to the home. I began by going up into the attic where I found that the blower motor was constantly running even with the thermostats off. Which is indicating a high voltage short. I opened the blower compartment and tested for a short on the control board. As it was flashing indicating bad ground/reversed polarity. I found the short to be on the heat side of the control board. I presented findings to Brennan and homeowner. They went with replacement of the furnace control board. Unit was heating upon departure.
Preformed heating maintenance on a Lennox gas system 2015. I started by placing air advice machine in the home. However I did notice that the client has some remodeling going on in the home, which can cause the air quality to be a little worse than it actually is. I then proceeded to the attic where I tested all safeties and electrical components on the furnace. All tested within manufacturer specifications. The temperature being supplied to the home was at 120 degrees and the or being returned to the unit was at 76 degrees. I did changed the filter we provided to the client per his request. I noticed the system did not have any surge protection on either the inside unit or outside. Provided estimates to have surge protection installed. Set the thermostat back to cooling and the unit was cooling upon departure. 4" AprilAire Filter AprilAire 210/1410/910 Replacement Filter for AprilAire Whole House Air Purifiers - MERV 11, Clean Air & Dust, 20x25x4 Air Filter (each)
Arrived on site, for heating maintenance. Pastor Frank informed us all was well and he had no concerns with unit operation at this time. Proceeding with the heating maintenance on all 3 units. 2 2022 Trane furnaces and one Payne 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Tested inducer motor and pressure switches 7. Inspected surface igniter. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Cleaned and tested flame sensors on all units. Noticed oil leaking from the bearings on blower motor of older Payne unit. This is an indica
Perform single system heating maintenance. The system was installed in 2023. It is a communicating heat pump. I checked amps, filter, electrical, thermostat and temperature differential. The system is heating inside of manufacture specifications. I ran air advice machine to test the air quality of the home. I spoke to the customer to see if they are interested with adding the air scrubber the their system and uv stick inside their evaporator coil compartment to help prevent possible growth in their air handler. The customer is not interested in the Airscrubber and Uv bundle at this time due to other projects. A price for the IAQ bundle was requested for future reference. Unit was back to cooling upon departure
Preformed heating maintenance on 6 propane gas systems. We tested all electrical components and safeties for each system. All electrical components and safeties were testing within manufacturer specifications. We ran air advice to test air quality throughout the home. All reports came back with positive feedback. The client did mention that her allergies were becoming an issue. We provided estimates for a duct cleaning for the master bed room, the second master bedroom and installing an air scrubber on the first master bedroom unit to help combat the allergens. Units were back to cooling upon departure.
Arrived on site, Homeowner stated all was well with regulars to normal system operation. However he has not turned on heat so far. Began inspection at the outdoor unit. I first noticed that the outdoor coils were looking a little dirty, so I made sure to go ahead and give the coils a good rinse to promote the efficiency and longevity of the system. I then tested start and run amps and found them to be within manufacture specifications. I then measured capacitance on the capacitor and the hard kit and found them both to be within range. Proceeding to the indoor unit I changed and dated the filter. I tested normal heat pump operation as well as the electric heat strips and found all to be working as intended. Blower motor amps were within range. Inspected evaporator coil and found it to be clean.At this point, I noticed that the Plenum and ducts were rather dusty and I also noticed some bacterial growth around the wiring harness on the blower motor. I brought this to the homeowner’s atte
Preformed heating maintenance on single system gas. All electrical company safeties tested within manufacturer specifications. When we checked for gas leaks we found a leak at the top burner indicating a bad gas valve. Temp being supplied to the house was 121 and return was 79. Client had filter for us to change. Client has parts and labor for us to change out the gas valve. Unit was back to cooling upon departure We preformed dryer vent cleaning. Presented before and after pictures to client. Changed gas valve under warranty.
Arrived on site for heating maintenance on 2019 Goodman furnace 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Tested pressure switch, igniter and flame sensors 16. Tested inducer motor and safety switches Found water around inducer motor indicating that there is water getting into the flue pipe. This could cause malfunctions and failure of furnace components. I thoroughly tested functionality and safety of furnace
Upon arrival, I gained access to the attic space and measured the depth in multiple areas. I found that the home has an average of 7” of insulation. I located 1 recessed light, and I found, what I presumed to be the bathroom vent, to be buried in insulation. I noticed that one of the emergency pans was beginning to rust through. I brought this up to the customer. I have approval to heavily discount the emergency pan, if the customer approves the bundle option. This option includes: maintenance program, R38 insulation, and emergency drain pan.
Arrived to our clients home to evaluate the clients wants and needs for an ERV. Our client shared with me that they had recently remodeled the downstairs and upgraded the front door as well. They shared with me that the ecobee thermostat for the upstairs began reading spikes of VOC’s and CO2 after the remodeling was completed. This is there biggest concern and want a solution to help maintain low/ normal levels of VOC’s and CO2 in the home. Their temporary solution is to have windows open throughout the home to bring in fresh air. This presents a humidity and allergen issue which they are also concerned about. I proceeded to evaluate the upflow closet unit in the upstairs space. I then went into the attic opening to evaluate the existing ductwork and potential for adding a fresh air intake or ERV option. I found that the supply duct was not connected to a plenum box but instead was a single 18” duct connected to a wye and 2 separate mixing boxes. The attic space only allows space to th
I arrived to our clients home for a full system equipment estimate. Julie walked me through her home and showed me the main attic entrance. I took video to measure and check the ductwork for the existing equipment. She then showed me other attic access points which would allow for us to make modifications to her existing duct work for the front portion of her home. The current downstairs unit has a single 18” return and we discussed the option to add an additional return vent to the front portion of her home to help airflow and overall comfort. I created some options and sent them over to Julie, she will review them and i will follow up with her later this week.
I performed a single system heating maintenance on a 2016 gas system. I choked amps, capacitor, filter, electrical, cleanliness, and safeties. I noticed that the emergency pan is compromised and forming rust spot on the bottom side, the outdoor unit is matted with build up, and the system is currently not protected by surge protection. I provided pricing for these areas of safety and concern.