Menu

Heating and Air Conditioning Services in Sherman, TX

Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between January 2026 and March 2026.

The most recent job was on March 13, 2026.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found capacitor measuring outside of manufacturer specification. 36.44 out of a minimum spec of 38/40. Capacitor is liable to fail at any point which would leave the ac unit nonfunctional. Upon testing drain line it was found that the drain line is almost entirely clogged and draining into
Sherman, TX 75092
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found capacitor measuring outside of manufacturer specification. 36.44 out of a minimum spec of 38/40. Capacitor is liable to fail at any point which would leave the ac unit nonfunctional.  Upon testing drain line it was found that the drain line is almost entirely clogged and draining into
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 


Found capacitor measuring outside of manufacturer specification. 36.44 out of a minimum spec of 38/40. Capacitor is liable to fail at any point which would leave the ac unit nonfunctional.  Upon testing drain line it was found that the drain line is almost entirely clogged and draining into
Shelby S.
Shelby S.
I performed a single system cooling maintenance on a 8 month old R454b heat pump system. I checked amps, filter, electrical, cleanliness, drains, and safeties. The system is running well with zero mechanical concerns. I offered surge protection to reduce the risk of electrical damage and protect the customer’s investment. Customer declined during the time of service.
Sherman, TX 75090
Sherman, TX - I performed a single system cooling maintenance on a 8 month old R454b heat pump system. I checked amps, filter, electrical, cleanliness, drains, and safeties. The system is running well with zero mechanical concerns. I offered surge protection to reduce the risk of electrical damage and protect the customer’s investment. Customer declined during the time of service.
Sherman, TX - I performed a single system cooling maintenance on a 8 month old R454b heat pump system. I checked amps, filter, electrical, cleanliness, drains, and safeties. The system is running well with zero mechanical concerns. I offered surge protection to reduce the risk of electrical damage and protect the customer’s investment. Customer declined during the time of service.
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Noticed drain line was draining but not very quickly. Advised customer I could attempt to clear the drain line with addition of a blowout valve as I could not clear it as it was tied to the hot water heater in the return. After installation, I was then able to easily clear the line with my
Sherman, TX 75090
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages

Noticed drain line was draining but not very quickly. Advised customer I could attempt to clear the drain line with addition of a blowout valve as I could not clear it as it was tied to the hot water heater in the return.    After installation, I was then able to easily clear the line with my
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages

Noticed drain line was draining but not very quickly. Advised customer I could attempt to clear the drain line with addition of a blowout valve as I could not clear it as it was tied to the hot water heater in the return.    After installation, I was then able to easily clear the line with my
Shelby S.
Shelby S.
I performed 2 cooling maintenances on a 2024 and 2019 heat pump systems. I checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. I offered additional safeties and a start assist. Customer declined during service.
Sherman, TX 75090
Sherman, TX - I performed 2 cooling maintenances on a 2024 and 2019 heat pump systems. I checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. I offered additional safeties and a start assist. Customer declined during service.
Sherman, TX - I performed 2 cooling maintenances on a 2024 and 2019 heat pump systems. I checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. I offered additional safeties and a start assist. Customer declined during service.
Brayden W.
Brayden W.
1. Rinsed condenser with water to promote heat exchange and reduce stress on system 2. Visually inspected condenser coil for debris/ dirty. 3. Inspected condenser fan motor. 4. Inspected condenser fan blades. 5. Inspected/ cleaned wiring connections. 6. Tested compressor/ condenser fan motor capacitor. 7. Checked compressor amp draw. 8. Checked condenser fan motor amp draw. 9. Inspected / replaced return filter. 10. Inspected return plenum for debris/ dirty. 11. Inspected evaporator coil. 12. Inspected blower motor/ blower wheel. 13. Checked blower amp draw. 14. Measured temperature differential from supply to return. 20 degrees measured. 15. Inspected drain lines and treated to prevent blockages Found large amount of dust in the return Plenum for the system being so new. Advised installation of Air scrubber to reduce particulate matter in the home by causing fine particulates to clump together and get picked up by the filter. Also recommend installation of surge protection to protec
Sherman, TX 75092
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Found large amount of dust in the return Plenum for the system being so new. Advised installation of Air scrubber to reduce particulate matter in the home by causing fine particulates to clump together and get picked up by the filter. Also recommend installation of surge protection to protec
Sherman, TX - 1. Rinsed condenser with water to promote heat exchange and reduce stress on system
2. Visually inspected condenser coil for debris/ dirty.
3. Inspected condenser fan motor.
4. Inspected condenser fan blades.
5. Inspected/ cleaned wiring connections.
6. Tested compressor/ condenser fan motor capacitor.
7. Checked compressor amp draw.
8. Checked condenser fan motor amp draw.
9. Inspected / replaced return filter.
10. Inspected return plenum for debris/ dirty.
11. Inspected evaporator coil.
12. Inspected blower motor/ blower wheel.
13. Checked blower amp draw.
14. Measured temperature differential from supply to return. 20 degrees measured.
15. Inspected drain lines and treated to prevent blockages 

Found large amount of dust in the return Plenum for the system being so new. Advised installation of Air scrubber to reduce particulate matter in the home by causing fine particulates to clump together and get picked up by the filter. Also recommend installation of surge protection to protec
Shelby S.
Shelby S.
Unit is a 2017 gas system. It is not communicating or zoned. Blower wheel in need of cleaning. Dirty blower wheels add stress to the motor itself resulting in premature failure. The u/v light had been removed from the system. Customer has a replacement bulb. The bulb was installed in the incorrect location and without a dedicated transformer. This price is the put it on a dedicated transformer in the same location in which it was previously located. The contactor has heavy burning present in the contacts. It is advised to have it replaced. The compressor is start at 75% of its allotted amperage load. It is advised to install a start assist to limit stress on the compressor. The damage to the internals of the compressor are irreversible. I relocated the u/v to above the evaporator coil, and wired in a transformer for the power. I installed a hard start kit to lower the starting amperage. The humidifier is not operational due to the water being shut off. The fitting leaks wh
Sherman, TX 75092
Sherman, TX - Unit is a 2017 gas system. It is not communicating or zoned. 

Blower wheel in need of cleaning. Dirty blower wheels add stress to the motor itself resulting in premature failure.

The u/v light had been removed from the system. Customer has a replacement bulb. The bulb was installed in the incorrect location and without a dedicated transformer. This price is the put it on a dedicated transformer in the same location in which it was previously located. 

The contactor has heavy burning present in the contacts. It is advised to have it replaced. 

The compressor is start at 75% of its allotted amperage load. It is advised to install a start assist to limit stress on the compressor. The damage to the internals of the compressor are irreversible. 

I relocated the u/v to above the evaporator coil, and wired in a transformer for the power. 

I installed a hard start kit to lower the starting amperage. 

The humidifier is not operational due to the water being shut off. The fitting leaks wh
Sherman, TX - Unit is a 2017 gas system. It is not communicating or zoned. 

Blower wheel in need of cleaning. Dirty blower wheels add stress to the motor itself resulting in premature failure.

The u/v light had been removed from the system. Customer has a replacement bulb. The bulb was installed in the incorrect location and without a dedicated transformer. This price is the put it on a dedicated transformer in the same location in which it was previously located. 

The contactor has heavy burning present in the contacts. It is advised to have it replaced. 

The compressor is start at 75% of its allotted amperage load. It is advised to install a start assist to limit stress on the compressor. The damage to the internals of the compressor are irreversible. 

I relocated the u/v to above the evaporator coil, and wired in a transformer for the power. 

I installed a hard start kit to lower the starting amperage. 

The humidifier is not operational due to the water being shut off. The fitting leaks wh
Shelby S.
Shelby S.
I checked the unit multiple times, and was unable to produce any noises that would be deemed abnormal. I secured the door for the outdoor unit due to the screws being striped. It seems like the customer may be hearing the reversing valve energizing causing pressure to rapidly equalize. System is performing properly at the time of service. Requested the customer to record if the sound comes back.
Sherman, TX 75092
Sherman, TX - I checked the unit multiple times, and was unable to produce any noises that would be deemed abnormal. I secured the door for the outdoor unit due to the screws being striped. It seems like the customer may be hearing the reversing valve energizing causing pressure to rapidly equalize. System is performing properly at the time of service. Requested the customer to record if the sound comes back.
Sherman, TX - I checked the unit multiple times, and was unable to produce any noises that would be deemed abnormal. I secured the door for the outdoor unit due to the screws being striped. It seems like the customer may be hearing the reversing valve energizing causing pressure to rapidly equalize. System is performing properly at the time of service. Requested the customer to record if the sound comes back.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2020 communicating gas system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered that the system is in deep need of a duct cleaning. Dust is the number 1 root cause of system failure. I noticed that the current filter does not fully seal when installed. This allows a bunch of the dust to bypass the filter into the rest of the system. I proposed upgrading the filter to help keep the system cleaner reducing cleaning costs. While outside inspecting the condenser, I documented excessive build up on the backside of the condensing coil. This air restriction makes the system cost more to run because it cannot efficiently remove the heat from the system, run time is increased, and it adds strain to the compressor/condenser fan motor. I provided options after the time of service due to poor internet connection. Customer would like to reach out to us within the next 2 weeks.
Sherman, TX 75092
Sherman, TX - I performed a single heating maintenance on a 2020 communicating gas system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered that the system is in deep need of a duct cleaning. Dust is the number 1 root cause of system failure. I noticed that the current filter does not fully seal when installed. This allows a bunch of the dust to bypass the filter into the rest of the system. I proposed upgrading the filter to help keep the system cleaner reducing cleaning costs. While outside inspecting the condenser, I documented excessive build up on the backside of the condensing coil. This air restriction makes the system cost more to run because it cannot efficiently remove the heat from the system, run time is increased, and it adds strain to the compressor/condenser fan motor. I provided options after the time of service due to poor internet connection. Customer would like to reach out to us within the next 2 weeks.
Sherman, TX - I performed a single heating maintenance on a 2020 communicating gas system. I checked amps, capacitors, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I discovered that the system is in deep need of a duct cleaning. Dust is the number 1 root cause of system failure. I noticed that the current filter does not fully seal when installed. This allows a bunch of the dust to bypass the filter into the rest of the system. I proposed upgrading the filter to help keep the system cleaner reducing cleaning costs. While outside inspecting the condenser, I documented excessive build up on the backside of the condensing coil. This air restriction makes the system cost more to run because it cannot efficiently remove the heat from the system, run time is increased, and it adds strain to the compressor/condenser fan motor. I provided options after the time of service due to poor internet connection. Customer would like to reach out to us within the next 2 weeks.
Shelby S.
Shelby S.
I performed a single heating maintenance on a 2023 heat pump system. I checked amps, capacitor, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I came across a couple of notable concerns. I observed that the indoor unit is free of growth with 0 preventatives to keep it that way. Airhandlers are prone to growth formations as early as the first year of install reducing air quality and straining the system. The outdoor capacitor is reading on the bottom edge of the rating ranged and in the process of failing. The outdoor unit sits at a slope. This causes the oil in the compressor to not return to the correct places. With it doing that, it causes hot spots resulting in irreversible damage. I provided pricing to address these issues at the time of service.
Sherman, TX 75092
Sherman, TX - I performed a single heating maintenance on a 2023 heat pump system. I checked amps, capacitor, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I came across a couple of notable concerns. I observed that the indoor unit is free of growth with 0 preventatives to keep it that way. Airhandlers are prone to growth formations as early as the first year of install reducing air quality and straining the system. The outdoor capacitor is reading on the bottom edge of the rating ranged and in the process of failing. The outdoor unit sits at a slope. This causes the oil in the compressor to not return to the correct places. With it doing that, it causes hot spots resulting in irreversible damage. I provided pricing to address these issues at the time of service.
Sherman, TX - I performed a single heating maintenance on a 2023 heat pump system. I checked amps, capacitor, filter, electrical, cleanliness, and safeties. During my thorough evaluation, I came across a couple of notable concerns. I observed that the indoor unit is free of growth with 0 preventatives to keep it that way. Airhandlers are prone to growth formations as early as the first year of install reducing air quality and straining the system. The outdoor capacitor is reading on the bottom edge of the rating ranged and in the process of failing. The outdoor unit sits at a slope. This causes the oil in the compressor to not return to the correct places. With it doing that, it causes hot spots resulting in irreversible damage. I provided pricing to address these issues at the time of service.
Matthew C.
Matthew C.
Checked all electrical out on both units everything is working and checked out how it was supposed to. Clients renewed their maintenance membership
Sherman, TX 75092
Sherman, TX - Checked all electrical out on both units everything is working and checked out how it was supposed to. Clients renewed their maintenance membership
Sherman, TX - Checked all electrical out on both units everything is working and checked out how it was supposed to. Clients renewed their maintenance membership

Your High Efficiency

Experts