Heating and Air Conditioning Services in Sherman, TX

Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between December 2025 and January 2026.

The most recent job was on January 21, 2026.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Noticed drain line was draining slowly initially, but after some flushing it appeared to be draining better. Also noticed decent amount of dust build up on blower wheel this causes drag on the motor and forces it to work harder to keep up. Ultimately shortening the lifespan of the motor. Sent findings to h
Sherman, TX 75090
Sherman, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Noticed drain line was draining slowly initially, but after some flushing it appeared to be draining better. Also noticed decent amount of dust build up on blower wheel this causes drag on the motor and forces it to work harder to keep up. Ultimately shortening the lifespan of the motor. Sent findings to h
Sherman, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Noticed drain line was draining slowly initially, but after some flushing it appeared to be draining better. Also noticed decent amount of dust build up on blower wheel this causes drag on the motor and forces it to work harder to keep up. Ultimately shortening the lifespan of the motor. Sent findings to h
Shelby S.
Shelby S.
Upon arrival, I performed a power cycle of the system. This removed the code on the thermostat. After a time delay, the system came on and began heating. It was not heating before. I took reading of the operation of the system and confirmed that he system is fully functional. To reboot the system, I shut off both breakers. They are labeled A/C and furnace. After 5 mins, I turned the A/C breaker on and then the furnace breaker. System is heating upon departure.
Sherman, TX 75092
Sherman, TX - Upon arrival, I performed a power cycle of the system. This removed the code on the thermostat. After a time delay, the system came on and began heating. It was not heating before. I took reading of the operation of the system and confirmed that he system is fully functional. To reboot the system, I shut off both breakers. They are labeled A/C and furnace. After 5 mins, I turned the A/C breaker on and then the furnace breaker. System is heating upon departure.
Sherman, TX - Upon arrival, I performed a power cycle of the system. This removed the code on the thermostat. After a time delay, the system came on and began heating. It was not heating before. I took reading of the operation of the system and confirmed that he system is fully functional. To reboot the system, I shut off both breakers. They are labeled A/C and furnace. After 5 mins, I turned the A/C breaker on and then the furnace breaker. System is heating upon departure.
Shelby S.
Shelby S.
I performed a complimentary heating check-up on 2 systems. I discovered that the lennox system needs a hard start due to pulling 67/71 amps on start up. I observed that neither system has surge protection. I would highly advise that at least one be put on the carrier system. The unit is a carrier infinity and has a big control board in the outdoor unit. These boards are susceptible to surge damage. Units are heating upon departure.
Sherman, TX 75090
Sherman, TX - I performed a complimentary heating check-up on 2 systems. I discovered that the lennox system needs a hard start due to pulling 67/71 amps on start up. I observed that neither system has surge protection. I would highly advise that at least one be put on the carrier system. The unit is a carrier infinity and has a big control board in the outdoor unit. These boards are susceptible to surge damage. Units are heating upon departure.
Sherman, TX - I performed a complimentary heating check-up on 2 systems. I discovered that the lennox system needs a hard start due to pulling 67/71 amps on start up. I observed that neither system has surge protection. I would highly advise that at least one be put on the carrier system. The unit is a carrier infinity and has a big control board in the outdoor unit. These boards are susceptible to surge damage. Units are heating upon departure.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Found no surge protection on indoor or outdoor unit. Surge protection would be great to have as an additional layer of protection to protect expensive components from things like blackout, brownouts, or even proximity lightning strikes search protectors come with a three-year warrant
Sherman, TX 75092
Sherman, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues

Found no surge protection on indoor or outdoor unit. Surge protection would be great to have as an additional layer of protection to protect expensive components from things like blackout, brownouts, or even proximity lightning strikes search protectors come with a three-year warrant
Sherman, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues

Found no surge protection on indoor or outdoor unit. Surge protection would be great to have as an additional layer of protection to protect expensive components from things like blackout, brownouts, or even proximity lightning strikes search protectors come with a three-year warrant
Matthew C.
Matthew C.
Performed a complete heating system maintenance and inspection. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Inspected for cleanliness of the duct work, blower wheel and evaporator coil. Al, could benefit from having a deep cleaning done. Verified system temperatures: return air temperature measured at 72°F; supply air temperature measured at 110F and rising. Confirmed air filter was recently replaced by client. Inspected and tested all electrical components on the outdoor unit; all components tested within manufacturer specifications. Outdoor condenser could benefit from having a deep cleaning. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service. Client is interested in having cleanings done, she just needs to speak with her husband about what they would like to do.
Sherman, TX 75090
Sherman, TX - Performed a complete heating system maintenance and inspection.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Inspected for cleanliness of the duct work, blower wheel and evaporator coil. Al, could benefit from having a deep cleaning done. 

Verified system temperatures: return air temperature measured at 72°F; supply air temperature measured at 110F and rising.

Confirmed air filter was recently replaced by client.

Inspected and tested all electrical components on the outdoor unit; all 
components tested within manufacturer specifications. 

Outdoor condenser could benefit from having a deep cleaning.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.

Client is interested in having cleanings done, she just needs to speak with her husband about what they would like to do.
Sherman, TX - Performed a complete heating system maintenance and inspection.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Inspected for cleanliness of the duct work, blower wheel and evaporator coil. Al, could benefit from having a deep cleaning done. 

Verified system temperatures: return air temperature measured at 72°F; supply air temperature measured at 110F and rising.

Confirmed air filter was recently replaced by client.

Inspected and tested all electrical components on the outdoor unit; all 
components tested within manufacturer specifications. 

Outdoor condenser could benefit from having a deep cleaning.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.

Client is interested in having cleanings done, she just needs to speak with her husband about what they would like to do.
Brayden W.
Brayden W.
Next service insulate copper lines up arma flex required
Sherman, TX 75090
Sherman, TX - Next service insulate copper lines up arma flex required
Sherman, TX - Next service insulate copper lines up arma flex required
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested capacitor and contactor (outdoor electrical) 15. Rinsed condenser unit to promote heat exchange 16. Tested emergency heat and found no issues Noticed no surge protection on both indoor and outdoor units. Recommend surge protection to protect equipment from surges in power. Air quality report came back reporting large amounts of particulate matter. Recommended air scrubber to improve air quality and life of system. Homeowne
Sherman, TX 75090
Sherman, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues

Noticed no surge protection on both indoor and outdoor units. Recommend surge protection to protect equipment from surges in power. Air quality report came back reporting large amounts of particulate matter. Recommended air scrubber to improve air quality and life of system. Homeowne
Sherman, TX - 1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested capacitor and contactor (outdoor electrical)
15. Rinsed condenser unit to promote heat exchange
16. Tested emergency heat and found no issues

Noticed no surge protection on both indoor and outdoor units. Recommend surge protection to protect equipment from surges in power. Air quality report came back reporting large amounts of particulate matter. Recommended air scrubber to improve air quality and life of system. Homeowne
Brayden W.
Brayden W.
1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. All safeties and sensors functioning properly. Unit in good working order. Performed dryer vent cleaning. Noticed that dryer vent was not putting out enough air. Upon further investigation I found the dryer vent flex falling apart. Suggested repair was approved by homeowner over the phone. Performed repair with sealing around dryer vent.
Sherman, TX 75092
Sherman, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.

All safeties and sensors functioning properly. Unit in good working order. Performed dryer vent cleaning. Noticed that dryer vent was not putting out enough air. Upon further investigation I found the dryer vent flex falling apart. Suggested repair was approved by homeowner over the phone. Performed repair with sealing around dryer vent.
Sherman, TX -  1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.

All safeties and sensors functioning properly. Unit in good working order. Performed dryer vent cleaning. Noticed that dryer vent was not putting out enough air. Upon further investigation I found the dryer vent flex falling apart. Suggested repair was approved by homeowner over the phone. Performed repair with sealing around dryer vent.
Brayden W.
Brayden W.
Customer stated rooms on left side of house were not keeping up. Noticed alert on thermostat for batteries and temperature sensor. Last time I was here customer was unable to find the temperature sensor, so I advised them to replace the batteries at their convenience when they find it. Upon inspecting temperature sensor for the right side of the house I found a large amount of corrosion on the terminals, preventing a good connection. I then cleaned off the corrosion from the terminals and replaced the batteries. No errors were found on the thermostat after replacing the batteries and this should help. Keep the temperature balance throughout the home a lot better. I then tested to ensure the compressor was running at full capacity and the heat kit was still working as designed. Found no issues with the heating cycle. Suggested to homeowner if temperature balance does not improve on the left side of the house that they may need another temperature sensor to ensure a better balance. Left
Sherman, TX 75092
Shelby S.
Shelby S.
Upon arrival, I discovered that outdoor unit did not have any power to it. I verify that my disconnect is functioning properly. I proceeded inside and located a tripped breaker in the panel. I attempted to cycle it but it tripped instantly. I unhooked the compressor and performed the same test. It tripped again. I performed the test another time, but with the compressor wired in and the fan motor wired out. The unit tripped instantly. I ohmed the motor and found that there are busted windings. I observed that the contactor is worn. I reached out to the landlord to get approval for a contactor and condenser fan motor. I installed a new motor, a contactor, and a capacitor for the motor. I took the supply temperature and have a 30+ degree temperature rise. System does not have a back up source of, heat for the system. Customer elected to have the invoice payment link sent to him. System is heating upon departure.
Sherman, TX 75090
Sherman, TX - Upon arrival, I discovered that outdoor unit did not have any power to it. I verify that my disconnect is functioning properly. I proceeded inside and located a tripped breaker in the panel. I attempted to cycle it but it tripped instantly. I unhooked the compressor and performed the same test. It tripped again. I performed the test another time, but with the compressor wired in and the fan motor wired out. The unit tripped instantly. I ohmed the motor and found that there are busted windings. I observed that the contactor is worn. I reached out to the landlord to get approval for a contactor and condenser fan motor. I installed a new motor, a contactor, and a capacitor for the motor. I took the supply temperature and have a 30+ degree temperature rise. System does not have a back up source of, heat for the system. Customer elected to have the invoice payment link sent to him. System is heating upon departure.
Sherman, TX - Upon arrival, I discovered that outdoor unit did not have any power to it. I verify that my disconnect is functioning properly. I proceeded inside and located a tripped breaker in the panel. I attempted to cycle it but it tripped instantly. I unhooked the compressor and performed the same test. It tripped again. I performed the test another time, but with the compressor wired in and the fan motor wired out. The unit tripped instantly. I ohmed the motor and found that there are busted windings. I observed that the contactor is worn. I reached out to the landlord to get approval for a contactor and condenser fan motor. I installed a new motor, a contactor, and a capacitor for the motor. I took the supply temperature and have a 30+ degree temperature rise. System does not have a back up source of, heat for the system. Customer elected to have the invoice payment link sent to him. System is heating upon departure.

Your High Efficiency

Experts