Heating and Air Conditioning Services in Sherman, TX

Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between September 2025 and October 2025.

The most recent job was on October 2, 2025.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Shelby S.
Shelby S.
Upon arrival, customer discussed the noise issue that was happening. We cycled this unit multiple times, and we found that the noise would happen in short run times. This is directly related to the compressor’s self lubrication. When the system runs for a short amount of time, the rotor does receive enough lubrication resulting in a slightly clunky noise. System is fully operational and cooling properly.
Sherman, TX 75090
Sherman, TX - Upon arrival, customer discussed the noise issue that was happening. We cycled this unit multiple times, and we found that the noise would happen in short run times. This is directly related to the compressor’s self lubrication. When the system runs for a short amount of time, the rotor does receive enough lubrication resulting in a slightly clunky noise. System is fully operational and cooling properly.
Sherman, TX - Upon arrival, customer discussed the noise issue that was happening. We cycled this unit multiple times, and we found that the noise would happen in short run times. This is directly related to the compressor’s self lubrication. When the system runs for a short amount of time, the rotor does receive enough lubrication resulting in a slightly clunky noise. System is fully operational and cooling properly.
Shelby S.
Shelby S.
Upon arrival, I found that the blower motor was not coming on. I discovered that the bolt holding the blower has stripped due to the blower wheel being dirty. I pulled the blower assembly out of the unit and was able to secure the blower back in place (for now). The blower would start up but sounded awful. With the customer’s approval, I replaced the capacitor. The blower sounds 10 times better. I informed the customer of the severity of the unit and informed her that the system is in rough shape. The unit needs a full cleaning of the evaporator coil and blower wheel. Customer was up and cooling upon departure.
Sherman, TX 75090
Sherman, TX - Upon arrival, I found that the blower motor was not coming on. I discovered that the bolt holding the blower has stripped due to the blower wheel being dirty. I pulled the blower assembly out of the unit and was able to secure the blower back in place (for now). The blower would start up but sounded awful. With the customer’s approval, I replaced the capacitor. The blower sounds 10 times better. I informed the customer of the severity of the unit and informed her that the system is in rough shape. The unit needs a full cleaning of the evaporator coil and blower wheel. Customer was up and cooling upon departure.
Sherman, TX - Upon arrival, I found that the blower motor was not coming on. I discovered that the bolt holding the blower has stripped due to the blower wheel being dirty. I pulled the blower assembly out of the unit and was able to secure the blower back in place (for now). The blower would start up but sounded awful. With the customer’s approval, I replaced the capacitor. The blower sounds 10 times better. I informed the customer of the severity of the unit and informed her that the system is in rough shape. The unit needs a full cleaning of the evaporator coil and blower wheel. Customer was up and cooling upon departure.
Matthew C.
Matthew C.
-Warranty Contactor -Warranty Capacitor - 5-2-1 Hard Start Kit Upon arrival i installed warranty capacitor 45/5. Installed warranty Contactor single pole Installed 5-2-1 hard start kit. Tested all electrical to make sure they were testing correctly for the manufacture. All tested within manufacturer specifications. I tested start amps on the unit yesterday 9/29/25 and was reading 50 amps on start up after installing the hard start kit on 9/30/25 i was reading the start up amps at 31 amps. Unit was cooling upon departure.
Sherman, TX 75090
Sherman, TX - -Warranty Contactor
-Warranty Capacitor
- 5-2-1 Hard Start Kit

Upon arrival i installed warranty capacitor 45/5.
Installed warranty Contactor single pole
Installed 5-2-1 hard start kit.

Tested all electrical to make sure they were testing correctly for the manufacture. All tested within manufacturer specifications. I tested start amps on the unit yesterday 9/29/25 and was reading 50 amps on start up after installing the hard start kit on 9/30/25 i was reading the start up amps at 31 amps. Unit was cooling upon departure.
Sherman, TX - -Warranty Contactor
-Warranty Capacitor
- 5-2-1 Hard Start Kit

Upon arrival i installed warranty capacitor 45/5.
Installed warranty Contactor single pole
Installed 5-2-1 hard start kit.

Tested all electrical to make sure they were testing correctly for the manufacture. All tested within manufacturer specifications. I tested start amps on the unit yesterday 9/29/25 and was reading 50 amps on start up after installing the hard start kit on 9/30/25 i was reading the start up amps at 31 amps. Unit was cooling upon departure.
Brayden W.
Brayden W.
Arrived on site for heating maintenance on Downstairs carrier heat pump. Upstairs 2024 heat pump 1.Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange 16. Replaced and dated filters 17. Tested emergency heat
Sherman, TX 75090
Sherman, TX - Arrived on site for heating maintenance on Downstairs carrier heat pump. Upstairs 2024 heat pump
1.Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange
16. Replaced and dated filters
17. Tested emergency heat
Sherman, TX - Arrived on site for heating maintenance on Downstairs carrier heat pump. Upstairs 2024 heat pump
1.Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested compressor/ condenser fan motor capacitor.
6. Checked compressor amp draw.
7. Checked condenser fan motor amp draw.
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Inspected blower motor/ blower wheel.
12. Checked blower amp draw.
13. Measured temperature differential from supply to return.
14. Inspected drain lines and treated to prevent blockages 
15. Rinsed condenser unit to promote heat exchange
16. Replaced and dated filters
17. Tested emergency heat
Matthew C.
Matthew C.
Preformed cooling maintenance on single system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain line with tots c. Filter did not need to be changed at this time. Temperature being supplied to the home is at 51 degrees and air being returned to the unit was at 71 degrees. I did notice the blower wheel to have dust/debris build up. I proceeded to the outside unit where I tested all electrical components on the outside unit along wi5 run and start amps of the compressor and fan motors. All tested within manufacturer specifications. Although I did find that the capacitor was testing closer to the lower end of the manufacturer range it is rated for 45/5 and was reading 43.7/45 and 4.9/5. The Contactor was testing on the higher side of its range at 19.2 ohms. Also the compressor is starting on the higher side of its range as well at 50/77. I left estimates for a compressor saver bundle along with a blower wheel cleaning. U
Sherman, TX 75090
Sherman, TX - Preformed cooling maintenance on single system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain line with tots c. Filter did not need to be changed at this time. Temperature being supplied to the home is at 51 degrees and air being returned to the unit was at 71 degrees. I did notice the blower wheel to have dust/debris build up. I proceeded to the outside unit where I tested all electrical components on the outside unit along wi5 run and start amps of the compressor and fan motors. All tested within manufacturer specifications. Although I did find that the capacitor was testing closer to the lower end of the manufacturer range it is rated for 45/5 and was reading 43.7/45 and 4.9/5. The Contactor was testing on the higher side of its range at 19.2 ohms. Also the compressor is starting on the higher side of its range as well at 50/77. I left estimates for a compressor saver bundle along with a blower wheel cleaning. U
Sherman, TX - Preformed cooling maintenance on single system. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I treated drain line with tots c. Filter did not need to be changed at this time. Temperature being supplied to the home is at 51 degrees and air being returned to the unit was at 71 degrees. I did notice the blower wheel to have dust/debris build up. I proceeded to the outside unit where I tested all electrical components on the outside unit along wi5 run and start amps of the compressor and fan motors. All tested within manufacturer specifications. Although I did find that the capacitor was testing closer to the lower end of the manufacturer range it is rated for 45/5 and was reading 43.7/45 and 4.9/5. The Contactor was testing on the higher side of its range at 19.2 ohms. Also the compressor is starting on the higher side of its range as well at 50/77. I left estimates for a compressor saver bundle along with a blower wheel cleaning. U
Shelby S.
Shelby S.
I combed the condenser fins to the best of my ability. Some fins are broken and too far gone to open them back up. The pictures are labeled A and B. B being before and A being after. MASHED COIL FINS PREVENT PROPER AIRFLOW AND CAN CAUSE DAMAGE TO THE COMPRESSOR. WE WILL TRY TO COMB THE FINS OPEN, BUT SOME MAY BE DAMAGED BEYOND WHAT WE CAN REPAIR.
Sherman, TX 75090
Sherman, TX - I combed the condenser fins to the best of my ability. Some fins are broken and too far gone to open them back up. The pictures are labeled A and B. B being before and A being after. 

MASHED COIL FINS PREVENT PROPER AIRFLOW AND CAN CAUSE DAMAGE TO THE COMPRESSOR. WE WILL TRY TO COMB THE FINS OPEN, BUT SOME MAY BE DAMAGED BEYOND WHAT WE CAN REPAIR.
Sherman, TX - I combed the condenser fins to the best of my ability. Some fins are broken and too far gone to open them back up. The pictures are labeled A and B. B being before and A being after. 

MASHED COIL FINS PREVENT PROPER AIRFLOW AND CAN CAUSE DAMAGE TO THE COMPRESSOR. WE WILL TRY TO COMB THE FINS OPEN, BUT SOME MAY BE DAMAGED BEYOND WHAT WE CAN REPAIR.
Shelby S.
Shelby S.
I performed a single system heating maintenance on a 2021 zoned heat pump. I checked amps, capacitor, filter, drains, electrical, heating kit, and safeties. The system is heating inside of manufacture specifications. I noticed some things that could use addressing. The house has high chemical content and carbon dioxide levels. The capacitor used to turn on the compressor is just out of spec and may lead to the compressor not starting. The system does not have a water safety switch to help prevent water damage associated with a clogged drain line. The system does not have a surge protector to prevent damage from surges. The compressor is beginning to pull high amps on start up. This leads to internal wear to happen. I provided options to address these listed issues. Customer declined any repairs/add-ons at the time of service.
Sherman, TX 75092
Sherman, TX - I performed a single system heating maintenance on a 2021 zoned heat pump. I checked amps, capacitor, filter, drains, electrical, heating kit, and safeties. The system is heating inside of manufacture specifications. I noticed some things that could use addressing. The house has high chemical content and carbon dioxide levels. The capacitor used to turn on the compressor is just out of spec and may lead to the compressor not starting. The system does not have a water safety switch to help prevent water damage associated with a clogged drain line. The system does not have a surge protector to prevent damage from surges. The compressor is beginning to pull high amps on start up. This leads to internal wear to happen. I provided options to address these listed issues. Customer declined any repairs/add-ons at the time of service.
Sherman, TX - I performed a single system heating maintenance on a 2021 zoned heat pump. I checked amps, capacitor, filter, drains, electrical, heating kit, and safeties. The system is heating inside of manufacture specifications. I noticed some things that could use addressing. The house has high chemical content and carbon dioxide levels. The capacitor used to turn on the compressor is just out of spec and may lead to the compressor not starting. The system does not have a water safety switch to help prevent water damage associated with a clogged drain line. The system does not have a surge protector to prevent damage from surges. The compressor is beginning to pull high amps on start up. This leads to internal wear to happen. I provided options to address these listed issues. Customer declined any repairs/add-ons at the time of service.
Shelby S.
Shelby S.
Upon getting on the roof, I discovered the panel off of the unit allowing hot air into the system. I found that the screws were stripped not allow the door to be secured. I placed the door back on and waited 20 mins. The system cooled down 4 degrees in the 20mins. Once I confirmed that it was the issue, I shut the unit down and checked electrical. I noticed that the condenser fan motor is worn and beginning to leak oil. I used tapping screws to make new holes to ensure the door would not come back off. Customer approved combing both unit’s condenser fins. I do not have a comb to perform the work today. Customer is available anytime during the week. Waved service fee with approved estimate. I emailed the customer pricing for a condenser fan motor and the service agreement.
Sherman, TX 75090
Sherman, TX - Upon getting on the roof, I discovered the panel off of the unit allowing hot air into the system. I found that the screws were stripped not allow the door to be secured. I placed the door back on and waited 20 mins. The system cooled down 4 degrees in the 20mins. Once I confirmed that it was the issue, I shut the unit down and checked electrical. I noticed that the condenser fan motor is worn and beginning to leak oil. I used tapping screws to make new holes to ensure the door would not come back off. Customer approved combing both unit’s condenser fins. I do not have a comb to perform the work today. Customer is available anytime during the week. Waved service fee with approved estimate. I emailed the customer pricing for a condenser fan motor and the service agreement.
Sherman, TX - Upon getting on the roof, I discovered the panel off of the unit allowing hot air into the system. I found that the screws were stripped not allow the door to be secured. I placed the door back on and waited 20 mins. The system cooled down 4 degrees in the 20mins. Once I confirmed that it was the issue, I shut the unit down and checked electrical. I noticed that the condenser fan motor is worn and beginning to leak oil. I used tapping screws to make new holes to ensure the door would not come back off. Customer approved combing both unit’s condenser fins. I do not have a comb to perform the work today. Customer is available anytime during the week. Waved service fee with approved estimate. I emailed the customer pricing for a condenser fan motor and the service agreement.
Shelby S.
Shelby S.
Preformed heating maintenance on a gas single system. We tested all electrical components on the inside furnace. All tested within manufacturer specifications. We tested all safeties to insures they were in good working order. All safeties passed today’s inspection. Filter did not need to be changed at this time. We did notice that the client has uv lights installed inside the unit . Uv lights are in working order. We found that the unit did not have any type of surge protection. We spoke to the client about the benefits of having their unit protected from possible surges of power. Client elected to have two surge protectors installed on the inside unit as well as the outside unit. We changed the thermostat back to cooling and unit was in good working condition upon departure.
Sherman, TX 75090
Sherman, TX - Preformed heating maintenance on a gas single system. We tested all electrical components on the inside furnace. All tested within manufacturer specifications. We tested all safeties to insures they were in good working order. All safeties passed today’s inspection. Filter did not need to be changed at this time. We did notice that the client has uv lights installed inside the unit . Uv lights are in working order.  We found that the unit did not have any type of surge protection. We spoke to the client about the benefits of having their unit protected from possible surges of power. Client elected to have two surge protectors installed on the inside unit as well as the outside unit. We changed the thermostat back to cooling and unit was in good working condition upon departure.
Sherman, TX - Preformed heating maintenance on a gas single system. We tested all electrical components on the inside furnace. All tested within manufacturer specifications. We tested all safeties to insures they were in good working order. All safeties passed today’s inspection. Filter did not need to be changed at this time. We did notice that the client has uv lights installed inside the unit . Uv lights are in working order.  We found that the unit did not have any type of surge protection. We spoke to the client about the benefits of having their unit protected from possible surges of power. Client elected to have two surge protectors installed on the inside unit as well as the outside unit. We changed the thermostat back to cooling and unit was in good working condition upon departure.
Shelby S.
Shelby S.
I performed a single system heating maintenance on a 2023 gas system. I checked amps, capacitors, flame sensor, pressure switch, burners, safeties, and cleanliness. The system is performing to manufacture specifications. I proposed 2 recommendations: air scrubber to help keep the system clean and treat the air. A surge protector to help protect the indoor equipment from shorting out from a power fluctuation. Customer was working and unavailable at the end of the call.
Sherman, TX 75092
Sherman, TX - I performed a single system heating maintenance on a 2023 gas system. I checked amps, capacitors, flame sensor, pressure switch, burners, safeties, and cleanliness. The system is performing to manufacture specifications. I proposed 2 recommendations: air scrubber to help keep the system clean and treat the air. A surge protector to help protect the indoor equipment from shorting out from a power fluctuation.  Customer was working and unavailable at the end of the call.
Sherman, TX - I performed a single system heating maintenance on a 2023 gas system. I checked amps, capacitors, flame sensor, pressure switch, burners, safeties, and cleanliness. The system is performing to manufacture specifications. I proposed 2 recommendations: air scrubber to help keep the system clean and treat the air. A surge protector to help protect the indoor equipment from shorting out from a power fluctuation.  Customer was working and unavailable at the end of the call.

Your High Efficiency

Experts