Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between August 2025 and September 2025.

The most recent job was on September 14, 2025.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Brayden W.
Brayden W.
Arrived on site, found thermostat set to off. Client stated electrician was working on breaker panel and he was having various issues around the house. Started inspection at the furnace and found the blower motor would run normally when calling for fan. However, when the unit was put into cooling the blower would cycle on and off with the compressor running the whole time. Tested outdoor electrical and found no issues and turned off breaker to the outdoor unit for remainder of testing. With the outdoor unit powered down the furnace was still doing the same thing. Measured low voltage 24v and high voltage 120v to the motor. When reproducing the issue it was found that the voltage would start out normal but, would drop to 18-19v on low and 90v on the high before the motor would shut down and restart at 24v and 120v. Homeowner then reproduced very similar symptoms on his microwave and washing machine. Advised customer that this was a power issue and he would need to contact that electrici
Sherman, TX 75090
Sherman, TX - Arrived on site, found thermostat set to off. Client stated electrician was working on breaker panel and he was having various issues around the house. Started inspection at the furnace and found the blower motor would run normally when calling for fan. However, when the unit was put into cooling the blower would cycle on and off with the compressor running the whole time. Tested outdoor electrical and found no issues and turned off breaker to the outdoor unit for remainder of testing. With the outdoor unit powered down the furnace was still doing the same thing. Measured low voltage 24v and high voltage 120v to the motor. When reproducing the issue it was found that the voltage would start out normal but, would drop to 18-19v on low and 90v on the high before the motor would shut down and restart at 24v and 120v. Homeowner then reproduced very similar symptoms on his microwave and washing machine. Advised customer that this was a power issue and he would need to contact that electrici
Sherman, TX - Arrived on site, found thermostat set to off. Client stated electrician was working on breaker panel and he was having various issues around the house. Started inspection at the furnace and found the blower motor would run normally when calling for fan. However, when the unit was put into cooling the blower would cycle on and off with the compressor running the whole time. Tested outdoor electrical and found no issues and turned off breaker to the outdoor unit for remainder of testing. With the outdoor unit powered down the furnace was still doing the same thing. Measured low voltage 24v and high voltage 120v to the motor. When reproducing the issue it was found that the voltage would start out normal but, would drop to 18-19v on low and 90v on the high before the motor would shut down and restart at 24v and 120v. Homeowner then reproduced very similar symptoms on his microwave and washing machine. Advised customer that this was a power issue and he would need to contact that electrici
Brayden W.
Brayden W.
Full system cleaning on a gas system. The cleaning consisted of duct cleaning, blower wheel removal and cleaning, antimicrobial fog, and adding an air purifier to the system to help with the air quality and help maintain the system clean. After the deep cleaning we turned the system back on to make sure everything worked properly upon departure. System is running and cooling at this time.
Sherman, TX 75090
Sherman, TX - Full system cleaning on a gas system. 
The cleaning consisted of duct cleaning, blower wheel removal and cleaning, antimicrobial fog, and adding an air purifier to the system to help with the air quality and help maintain the system clean. 
After the deep cleaning we turned the system back on to make sure everything worked properly upon departure. 
System is running and cooling at this time.
Sherman, TX - Full system cleaning on a gas system. 
The cleaning consisted of duct cleaning, blower wheel removal and cleaning, antimicrobial fog, and adding an air purifier to the system to help with the air quality and help maintain the system clean. 
After the deep cleaning we turned the system back on to make sure everything worked properly upon departure. 
System is running and cooling at this time.
jcg311690@gmail.com
jcg311690@gmail.com
Demand call for heat pump from 2017 using air filter 16*25*1 not cooling properly. Upon arrival the customer showed me the thermostat, attic access, and system outside. She also provided me with an air filter today to replace. During my inspection I turned the system on ac mode and turned it down, I did hear the blower running but it wasn’t throwing cool air. I went to the outside unit and found it to not be turned on. After further investigation I found the system to not be getting low voltage to it. The wire outside was very brittle and had signs of corrosion. I went up to the attic and checked for low voltage and the system wasn’t sending anything to the outdoor unit. I checked the float switch and it was activated causing the outdoor unit to not receive signal. I looked further into why the float switch activated and found the primary drain line to have a small clog, I informed the customer about what was going on and asked if she knew where the primary drain line terminates. Sh
Sherman, TX 75090
jcg311690@gmail.com
jcg311690@gmail.com
Ac preventative maintenance on a gas system from 2021 with an air filter 20*20*1. Upon arrival the customer showed me around the house and brought to my attention that there was some kind of biological growth in some of the vents. He also stated that he changes the air filter whenever he sees it to be dirty. During my inspection I conducted an air quality test, checked electrical connections and components, and inspected the ductwork for dirt buildup and to see how far along that growth has travelled through the system. The air quality test showed there to be a lot of particulate matter in the air as well as carbon dioxide and chemicals. The ductwork was very dirty and there was more growth through out the ductwork and plenum boxes. I showed videos and pictures to the customer of what the inside of their system looks like and they decided to get this issue resolved because they have a newborn with weak lungs and want her to come home to great quality air. The customer wants a full
Sherman, TX 75090
Matthew C.
Matthew C.
Upon arrival homeowner stated that he noticed the outdoor unit it not running. I provided a call for cooling at the thermostat and proceeded outside. I noticed the outside unit was not running and checked the electrical components. I found the unit’s capacitor to be failing 24/40 on the compressor side. Client has 10 year P&L, I swapped out the capacitor with a new capacitor. After resetting the unit, i tested refrigerant pressures to ensure that there was no other concerns. Pressure were within range and temperature being supplied out of the unit inside was at 55 degrees. I did speak with the home owner about adding surge protection to his unit. He stated he would like to think about it. I provided estimate for adding surge protection. Unit was cooling upon departure.
Sherman, TX 75090
Sherman, TX - Upon arrival homeowner stated that he noticed the outdoor unit it not running. I provided a call for cooling at the thermostat and proceeded outside. I noticed the outside unit was not running and checked the electrical components. I found the unit’s capacitor to be failing 24/40 on the compressor side. Client has 10 year P&L, I swapped out the capacitor with a new capacitor. After resetting the unit, i tested refrigerant pressures to ensure that there was no other concerns. Pressure were within range and temperature being supplied out of the unit inside was at 55 degrees. I did speak with the home owner about adding surge protection to his unit. He stated he would like to think about it. I provided estimate for adding surge protection. Unit was cooling upon departure.
Sherman, TX - Upon arrival homeowner stated that he noticed the outdoor unit it not running. I provided a call for cooling at the thermostat and proceeded outside. I noticed the outside unit was not running and checked the electrical components. I found the unit’s capacitor to be failing 24/40 on the compressor side. Client has 10 year P&L, I swapped out the capacitor with a new capacitor. After resetting the unit, i tested refrigerant pressures to ensure that there was no other concerns. Pressure were within range and temperature being supplied out of the unit inside was at 55 degrees. I did speak with the home owner about adding surge protection to his unit. He stated he would like to think about it. I provided estimate for adding surge protection. Unit was cooling upon departure.
Shelby S.
Shelby S.
Upon arrival, I found that the outdoor unit was not running and the indoor unit was giving a communication error code. I proceeded outside to see that the outdoor unit was in a lock out due to the start circuit being open. I checked the capacitor and noticed that it was dead. I removed it to check it again and seen it was slightly bloated. The capacitor had a critical failure due to the inner seal rupturing. I replaced the 40/5 capacitor under parts and labor warranty. System is cooling upon departure with a 21 degree temperature split.
Sherman, TX 75090
Sherman, TX - Upon arrival, I found that the outdoor unit was not running and the indoor unit was giving a communication error code. I proceeded outside to see that the outdoor unit was in a lock out due to the start circuit being open. I checked the capacitor and noticed that it was dead. I removed it to check it again and seen it was slightly bloated. The capacitor had a critical failure due to the inner seal rupturing. I replaced the 40/5 capacitor under parts and labor warranty. System is cooling upon departure with a 21 degree temperature split.
Sherman, TX - Upon arrival, I found that the outdoor unit was not running and the indoor unit was giving a communication error code. I proceeded outside to see that the outdoor unit was in a lock out due to the start circuit being open. I checked the capacitor and noticed that it was dead. I removed it to check it again and seen it was slightly bloated. The capacitor had a critical failure due to the inner seal rupturing. I replaced the 40/5 capacitor under parts and labor warranty. System is cooling upon departure with a 21 degree temperature split.
Shelby S.
Shelby S.
Upon arrival, I found that the unit was leaking water. After running diagnostics on the equipment, I found that it was due to the drain being clogged paired with the hot water heater being tied to the drain. This tie in did not have a p trap resulting in it pulling air. This would cause it to be hard for the unit to drain properly. I removed the piping of the hot water heater and cleared the drain. I tested it with a half gallon of water and allowed it time to cycle to ensure proper drainage. The evaporator coil has a bunch of build up and the unit lacks a water safety switch. Customer declined further repairs at this time.
Sherman, TX 75092
Sherman, TX - Upon arrival, I found that the unit was leaking water. After running diagnostics on the equipment, I found that it was due to the drain being clogged paired with the hot water heater being tied to the drain. This tie in did not have a p trap resulting in it pulling air. This would cause it to be hard for the unit to drain properly. I removed the piping of the hot water heater and cleared the drain. I tested it with a half gallon of water and allowed it time to cycle to ensure proper drainage. The evaporator coil has a bunch of build up and the unit lacks a water safety switch. Customer declined further repairs at this time.
Sherman, TX - Upon arrival, I found that the unit was leaking water. After running diagnostics on the equipment, I found that it was due to the drain being clogged paired with the hot water heater being tied to the drain. This tie in did not have a p trap resulting in it pulling air. This would cause it to be hard for the unit to drain properly. I removed the piping of the hot water heater and cleared the drain. I tested it with a half gallon of water and allowed it time to cycle to ensure proper drainage. The evaporator coil has a bunch of build up and the unit lacks a water safety switch. Customer declined further repairs at this time.
Brayden W.
Brayden W.
Arrived on site for quality control check. Initially found unit to be keeping up with set point and homeowner stated all was well and that the system was working great to their knowledge. Started inspection of indoor unit, found unit to be putting out a cold 50 degrees with a 20 degree temperature split. Inspected wiring connections and found no issues. No obstructions of the indoor coil. Tested drain lines and found a small issue with the negative pressure of the unit sucking up water. Added a cap to prevent this from happening. Checked refrigerant pressures and found them to be in range. Outdoor unit is leveled properly. Tested float switch to ensure proper operation of safety features and found no issues. Inspected line set and found it to be free of leaks or kinks. Homeowner has no concerns at this time. Unit is in good working order upon departure.
Sherman, TX 75090
Sherman, TX - Arrived on site for quality control check. Initially found unit to be keeping up with set point and homeowner stated all was well and that the system was working great to their knowledge. Started inspection of indoor unit, found unit to be putting out a cold 50 degrees with a 20 degree temperature split. Inspected wiring connections and found no issues. No obstructions of the indoor coil. Tested drain lines and found a small issue with the negative pressure of the unit sucking up water. Added a cap to prevent this from happening. Checked refrigerant pressures and found them to be in range. Outdoor unit is leveled properly. Tested float switch to ensure proper operation of safety features and found no issues. Inspected line set and found it to be free of leaks or kinks. Homeowner has no concerns at this time. Unit is in good working order upon departure.
Sherman, TX - Arrived on site for quality control check. Initially found unit to be keeping up with set point and homeowner stated all was well and that the system was working great to their knowledge. Started inspection of indoor unit, found unit to be putting out a cold 50 degrees with a 20 degree temperature split. Inspected wiring connections and found no issues. No obstructions of the indoor coil. Tested drain lines and found a small issue with the negative pressure of the unit sucking up water. Added a cap to prevent this from happening. Checked refrigerant pressures and found them to be in range. Outdoor unit is leveled properly. Tested float switch to ensure proper operation of safety features and found no issues. Inspected line set and found it to be free of leaks or kinks. Homeowner has no concerns at this time. Unit is in good working order upon departure.
Matthew C.
Matthew C.
Preformed cooling maintenance on single system 2021 Amana heat pump. The client Rick stated that there were no concerns at this time. I began testing the inside units electrical components. All tested within manufacturer specifications. I treated the drain line with total c and changed the filter. Temperature across the indoor coil was 54 degrees supply and 79 return temp. I did see some dust build up on the indoor blower motor. The run amps for the blower motor at within manufacturer specifications. I proceeded to the outside unit where I tested all electrical components along with run and start amps for the the compressor and fan motors. All electrical components tested within manufacturer specifications and run and start amps for the compressor and fan motors were within manufacturer specifications range. I rinsed the outdoor coil with water. I provided an estimate for a blower wheel cleaning. Unit was cooling upon departure
Sherman, TX 75090
Sherman, TX - Preformed cooling maintenance on single system 2021 Amana heat pump. The client Rick stated that there were no concerns at this time. I began testing the inside units electrical components. All tested within manufacturer specifications. I treated the drain line with total c and changed the filter. Temperature across the indoor coil was 54 degrees supply and 79 return temp. I did see some dust build up on the indoor blower motor. The run amps for the blower motor at within manufacturer specifications. I proceeded to the outside unit where I tested all electrical components along with run and start amps for the the compressor and fan motors. All electrical components tested within manufacturer specifications and run and start amps for the compressor and fan motors were within manufacturer specifications range. I rinsed the outdoor coil with water. I provided an estimate for a blower wheel cleaning. Unit was cooling upon departure
Sherman, TX - Preformed cooling maintenance on single system 2021 Amana heat pump. The client Rick stated that there were no concerns at this time. I began testing the inside units electrical components. All tested within manufacturer specifications. I treated the drain line with total c and changed the filter. Temperature across the indoor coil was 54 degrees supply and 79 return temp. I did see some dust build up on the indoor blower motor. The run amps for the blower motor at within manufacturer specifications. I proceeded to the outside unit where I tested all electrical components along with run and start amps for the the compressor and fan motors. All electrical components tested within manufacturer specifications and run and start amps for the compressor and fan motors were within manufacturer specifications range. I rinsed the outdoor coil with water. I provided an estimate for a blower wheel cleaning. Unit was cooling upon departure
Jacob P.
Jacob P.
Arrived at our clients home for a single system inspection. Mrs Crawford expressed concerns of a burning smell that came out of the vents from time to time. I began by locating the indoor unit in the closet unit and did a brief visual inspection. I then proceeded outside to test and check all of the electrical components and Freon pressures of the unit. The capacitor, contactor and hard start kit all tested within range. The compressor start and run ams as well as the blower motor amps also were in manufacture specifications. I went back inside and tested the indoor blower motor. The motor had high start amps due to the excessive dust/growth build up on the blower wheel. I showed pictures to Mrs Crawford and we discussed cleaning the blower motor during the winter time when she was not running the unit. I created and sent an estimate to her. She elected to sign up for maintenance today and I proceeded to rinse the outdoor coils and treat the primary drain line today. The unit is coolin
Sherman, TX 75090
Sherman, TX - Arrived at our clients home for a single system inspection. Mrs Crawford expressed concerns of a burning smell that came out of the vents from time to time. I began by locating the indoor unit in the closet unit and did a brief visual inspection. I then proceeded outside to test and check all of the electrical components and Freon pressures of the unit. The capacitor, contactor and hard start kit all tested within range. The compressor start and run ams as well as the blower motor amps also were in manufacture specifications.
I went back inside and tested the indoor blower motor. The motor had high start amps due to the excessive dust/growth build up on the blower wheel. I showed pictures to Mrs Crawford and we discussed cleaning the blower motor during the winter time when she was not running the unit. I created and sent an estimate to her.
She elected to sign up for maintenance today and I proceeded to rinse the outdoor coils and treat the primary drain line today.
The unit is coolin
Sherman, TX - Arrived at our clients home for a single system inspection. Mrs Crawford expressed concerns of a burning smell that came out of the vents from time to time. I began by locating the indoor unit in the closet unit and did a brief visual inspection. I then proceeded outside to test and check all of the electrical components and Freon pressures of the unit. The capacitor, contactor and hard start kit all tested within range. The compressor start and run ams as well as the blower motor amps also were in manufacture specifications.
I went back inside and tested the indoor blower motor. The motor had high start amps due to the excessive dust/growth build up on the blower wheel. I showed pictures to Mrs Crawford and we discussed cleaning the blower motor during the winter time when she was not running the unit. I created and sent an estimate to her.
She elected to sign up for maintenance today and I proceeded to rinse the outdoor coils and treat the primary drain line today.
The unit is coolin