Menu

Heating and Air Conditioning Services in Sherman, TX

Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX in June 2026.

The most recent job was on June 23, 2026.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Shelby S.
Shelby S.
The thermostat wire is shorted R to W on the preexisting wire from the thermostat to the indoor equipment. I spoke with Jesse and we worked on a price to install a thermostat near the nearby the indoor unit and add a sensor to the main living room area to be the primary point of temperature reading. Customer wanted to install a surge protector and algae stick as well.
Sherman, TX 75090
Sherman, TX - The thermostat wire is shorted R to W on the preexisting wire from the thermostat to the indoor equipment. I spoke with Jesse and we worked on a price to install a thermostat near the nearby the indoor unit and add a sensor to the main living room area to be the primary point of temperature reading. Customer wanted to install a surge protector and algae stick as well.
Sherman, TX - The thermostat wire is shorted R to W on the preexisting wire from the thermostat to the indoor equipment. I spoke with Jesse and we worked on a price to install a thermostat near the nearby the indoor unit and add a sensor to the main living room area to be the primary point of temperature reading. Customer wanted to install a surge protector and algae stick as well.
Clever M.
Clever M.
Completed 1 system cooling tune up. No issues reported or found. Replaced filter and washed outside coils. Left estimate for surge protection.
Sherman, TX 75092
Sherman, TX - Completed 1 system cooling tune up. No issues reported or found. Replaced filter and washed outside coils. Left estimate for surge protection.
Sherman, TX - Completed 1 system cooling tune up. No issues reported or found. Replaced filter and washed outside coils. Left estimate for surge protection.
Brayden W.
Brayden W.
1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Found surge protector not light up. Checked wiring and found all to be good. Surge protector has taken a su
Sherman, TX 75090
Sherman, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Found surge protector not light up. Checked wiring and found all to be good. Surge protector has taken a su
Sherman, TX - 1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Found surge protector not light up. Checked wiring and found all to be good. Surge protector has taken a su
Shelby S.
Shelby S.
Upon arrival, I found the system operational. I checked out the indoor unit and then proceeded outside. I discovered the burning smell. The hard start kit blew likely due to the capacitor reading 24/70. Customer approved the replacement of the capacitor with a Turbo200x. System is cooling upon departure.
Sherman, TX 75090
Sherman, TX - Upon arrival, I found the system operational. I checked out the indoor unit and then proceeded outside. I discovered the burning smell. The hard start kit blew likely due to the capacitor reading 24/70. Customer approved the replacement of the capacitor with a Turbo200x. System is cooling upon departure.
Sherman, TX - Upon arrival, I found the system operational. I checked out the indoor unit and then proceeded outside. I discovered the burning smell. The hard start kit blew likely due to the capacitor reading 24/70. Customer approved the replacement of the capacitor with a Turbo200x. System is cooling upon departure.
Brayden W.
Brayden W.
Arrived on site, Found breakers to indoor and outdoor unit Turned off. Checked wiring connections and turn breakers back on system. Came on without issue. Measured refrigerant pressures and found them to be testing with in manufacture specifications. Homeowner advised me. He did not wait for the five minute time out. After switching breakers back on. Perform cooling maintenance on 2024 Trane straight AC with electric heat 1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and d
Sherman, TX 75090
Sherman, TX - Arrived on site, Found breakers to indoor and outdoor unit Turned off. Checked wiring connections and turn breakers back on system. Came on without issue. Measured refrigerant pressures and found them to be testing with in manufacture specifications. Homeowner advised me. He did not wait for the five minute time out. After switching breakers back on.

Perform cooling maintenance on 2024 Trane straight AC with electric heat
1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and d
Sherman, TX - Arrived on site, Found breakers to indoor and outdoor unit Turned off. Checked wiring connections and turn breakers back on system. Came on without issue. Measured refrigerant pressures and found them to be testing with in manufacture specifications. Homeowner advised me. He did not wait for the five minute time out. After switching breakers back on.

Perform cooling maintenance on 2024 Trane straight AC with electric heat
1.  Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and d
Matthew C.
Matthew C.
Placed uv armaflex around suction line and secured it. Presented before and after pictures
Sherman, TX 75090
Brayden W.
Brayden W.
Performed maintenance on 2025 furnace. 1. Visually inspected condenser coil for leaks and abnormalities. 2. Inspected condenser fan motor, blades and bearings. 3. Inspected, cleaned, and, tightened wiring connections. 4. Measured capacitance of compressor/fan motor capacitor. 5. Inspected and measured resistance of contactor 6. Measured compressor current draw. 7. Measured condenser fan motor amp draw. 8. Inspected and replaced return filter. 9. Inspected return plenum for dust or debris. 10. Inspected evaporator coil for cleanliness and oxidation. 11. Inspected blower motor/ blower wheel for dust and debris 12. Measured blower motor current draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Tested drain lines for proper drainage and treated to prevent blockages. 15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris. Added silicone to conduit before washing to prevent water from sittin
Sherman, TX 75090
Sherman, TX - Performed maintenance on 2025 furnace.
1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Added silicone to conduit before washing to prevent water from sittin
Sherman, TX - Performed maintenance on 2025 furnace.
1. Visually inspected condenser coil for leaks and abnormalities.
2. Inspected condenser fan motor, blades and bearings.
3. Inspected, cleaned, and, tightened wiring connections.
4. Measured capacitance of  compressor/fan motor capacitor.
5. Inspected and measured resistance of contactor
6. Measured compressor current draw.
7. Measured condenser fan motor amp draw.
8. Inspected and replaced return filter.
9. Inspected return plenum for dust or debris.
10. Inspected evaporator coil for cleanliness and oxidation.
11. Inspected blower motor/ blower wheel for dust and debris
12. Measured blower motor current draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Tested drain lines for proper drainage and treated to prevent blockages.
15. Rinsed condenser with water to promote heat exchange and reduce stress on system by removing dust and debris.

Added silicone to conduit before washing to prevent water from sittin
Clever M.
Clever M.
Quote Summary - Goodman Evaporator Coil Replacement Scope of Work • Recover refrigerant from existing system • Remove failed evaporator coil from Goodman air handler/furnace • Install new Goodman evaporator coil • Replace refrigerant filter drier to protect system from contaminants and moisture • Pressure test system to verify no leaks are present • Evacuate system to manufacturer specifications • Recharge system and verify proper refrigerant levels • Start and test system to confirm proper cooling operation for master bedroom system Materials & Equipment • Goodman evaporator coil • Replacement filter drier • Refrigerant as required • Brazing materials, nitrogen, and vacuum equipment Special Notes • Estimate is for the HVAC system servicing the master bedroom only • System will be fully tested after installation to verify proper performance and airflow • Additional refrigerant may be required depending on system condition and line length Warranty • Includes 1-year manufacturer war
Sherman, TX 75092
Shelby S.
Shelby S.
I performed a 2 system package unit maintenance on 2011 410a gas system. I checked amps, filters, electrical, drains, cleanliness, and safeties. I observed that the condenser fan motor for the kitchen unit is trying to seize up, the blower motor belt is loose on the kitchen unit, and the kitchen unit’s evaporator coil is nasty and causing water to not flow off the coil correctly. Customer opted to tighten the blower belt to prevent it falling off. Systems are cooling upon departure.
Sherman, TX 75090
Sherman, TX - I performed a 2 system package unit maintenance on 2011 410a gas system. I checked amps, filters, electrical, drains, cleanliness, and safeties. I observed that the condenser fan motor for the kitchen unit is trying to seize up, the blower motor belt is loose on the kitchen unit, and the kitchen unit’s evaporator coil is nasty and causing water to not flow off the coil correctly. Customer opted to tighten the blower belt to prevent it falling off. Systems are cooling upon departure.
Sherman, TX - I performed a 2 system package unit maintenance on 2011 410a gas system. I checked amps, filters, electrical, drains, cleanliness, and safeties. I observed that the condenser fan motor for the kitchen unit is trying to seize up, the blower motor belt is loose on the kitchen unit, and the kitchen unit’s evaporator coil is nasty and causing water to not flow off the coil correctly. Customer opted to tighten the blower belt to prevent it falling off. Systems are cooling upon departure.
Shelby S.
Shelby S.
I returned to install the condenser fan motor and clear the drain. I got all the work done and tested the system. It is up and cooling and the drain is flowing.
Sherman, TX 75090
Sherman, TX - I returned to install the condenser fan motor and clear the drain. I got all the work done and tested the system. It is up and cooling and the drain is flowing.
Sherman, TX - I returned to install the condenser fan motor and clear the drain. I got all the work done and tested the system. It is up and cooling and the drain is flowing.

Your High Efficiency

Experts