Adon Complete Air Conditioning and Heating has been providing HVAC service in Sherman, TX, for years from our home base in Anna, just down Highway 75. Whether your AC goes out in July, your furnace won’t fire up in January, or you’re looking to upgrade to a more efficient system before the next season hits, our technicians are running calls in Sherman every week.

We service all makes and models, we’re a Trane Comfort Specialist and Mitsubishi-authorized dealer, and we’re available 24 hours a day, 7 days a week for emergencies. Whether you’re in Heritage Ranch, Canyon Creek, Westwood Village, or one of the established neighborhoods near the Grayson County Courthouse, we know this area and we’re ready to help.

Schedule Service in ShermanCall (903) 482-4900

HVAC Services We Offer in Sherman

We handle everything heating and cooling for Sherman homeowners and businesses. Here’s what we do:

AC Repair. Same-day service available throughout Sherman and Grayson County. We diagnose and repair all makes and models, and the majority of our calls are resolved in a single visit.

AC Installation. When it’s time for a new system, we size it correctly using a proper load calculation and install it in accordance with the manufacturer’s specifications. All new installations come with up to a 10-year labor warranty.

HVAC Maintenance. Our Adon Care Club plan is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, and 24/7 emergency access. It’s the smartest way to protect your system before the heat hits.

Mini-Split Installation. Ductless systems for rooms, additions, or whole-home comfort without ductwork. We install single- and multi-zone systems throughout Sherman and surrounding Grayson County communities.

Heat Pump Installation and Repair. Heat pumps provide both heating and cooling from a single system. This is a practical choice for Sherman homeowners who want year-round efficiency without separate units.

Indoor Air Quality. Air filtration systems, UV purifiers, humidifiers, dehumidifiers, and a free “What Are You Breathing?” screening for Sherman area homeowners.

Air Duct Cleaning. Professional duct cleaning removes allergens, dust, and debris from your system, improving air quality throughout your home.

Air Duct Repair and Sealing. Leaky ducts can cost you 20 to 30 percent of your system’s output. We inspect, repair, and seal ductwork throughout Sherman and Grayson County.

Why Sherman Homeowners Choose Adon Complete

AC and Heating Service Throughout Sherman and Grayson County

We service every neighborhood in Sherman including Heritage Ranch, Westwood Village, Canyon Creek, Parkhaven, O’Hanlon Ranch, and the established neighborhoods around downtown and the Grayson County Courthouse area. We also serve the surrounding Grayson County communities of Denison, Van Alstyne, Gunter, Howe, Tom Bean, Pottsboro, and Whitesboro.

Schedule Service in ShermanCall (903) 482-4900

Sherman HVAC FAQ

Here are some common questions we get.

How much does AC repair cost in Sherman, TX?

Most AC repairs in Sherman run between $150 and $600, depending on the type of repair. Simple fixes like a capacitor replacement or refrigerant recharge are on the lower end. More involved repairs like a blower motor or evaporator coil replacement will cost more. We provide a clear estimate before any work begins. Call (903) 482-4900 to schedule a diagnostic visit.

Do you offer emergency HVAC service in Sherman?

Yes. We offer 24/7 emergency heating and air conditioning service throughout Sherman and Grayson County. When you call after hours, you reach a real person who can get a technician to your home fast. A broken AC in a Sherman summer is not something that can wait until morning.

What HVAC brands do you service in Sherman?

We service all makes and models including Trane, Lennox, Carrier, Daikin, Mitsubishi, Goodman, Rheem, and more. As a Trane Comfort Specialist and Mitsubishi-authorized dealer, we have factory-trained expertise on those brands specifically, but we won’t turn down a job because of the brand on the equipment.

Do you offer HVAC maintenance plans in Sherman?

Yes. Our Adon Care Club is $12 a month and includes two seasonal tune-ups, priority scheduling, repair discounts, no diagnostic fees, and 24/7 emergency response. It’s the most affordable way to keep your system running reliably through Grayson County’s hot summers and cold winters.

What areas of Sherman do you serve?

We serve all of Sherman and the surrounding Grayson County communities including McKinney, Anna, Van Alstyne, Denison, Gunter, Howe, and Tom Bean.

Schedule HVAC Service in Sherman Today

Whether you need same-day AC repair, a new system installed, or just want to get on a maintenance plan before the heat hits, we’re ready to help. Call Adon Complete Air Conditioning and Heating at (903) 482-4900 or schedule online.

Schedule Service in ShermanCall (903) 482-4900

Recent Jobs and Reviews in Sherman, TX

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and appreciation for the service provided. Customers consistently praise the professionalism, knowledge, and efficiency of the technicians, highlighting their courteous demeanor and thorough explanations of work performed. A recurring theme is the company's responsiveness, with many reviewers expressing gratitude for quick arrival times, same-day or next-day service, and emergency availability during hot weather conditions. The honest, straightforward approach without upselling or gimmicks is frequently mentioned as a standout quality that builds trust. Customers appreciate the clear communication from both technicians and office staff, including timely updates on arrival times. The friendly and patient attitudes of service providers, even in stressful situations, earn particular commendation. Many reviewers indicate they would highly recommend the company and plan to use their services again, with several noting this is their preferred choice after multiple positive experiences. The tone is enthusiastic and grateful, with customers feeling valued and well-served, particularly during urgent situations involving AC failures in extreme heat. Overall, the reviews convey a strong sense of reliability, integrity, and customer-focused service that generates loyalty and satisfaction.

Sherman, TX at a glance

Adon Complete Air Conditioning and Heating has completed 10 jobs in Sherman, TX between May 2026 and June 2026.

The most recent job was on June 3, 2026.

Adon Complete Air Conditioning and Heating has completed 138 jobs in Sherman, TX in the last 12 months. The first job there was in March 2020.

Job Locations

Brayden W.
Brayden W.
Homeowner stated unit was not keeping up with set point. Tested supply temp and only measured 64-65. Measured refrigerant pressures and found them to be low on refrigerant. Conducted courtesy leak check and found a leak at the evaporator coil. Leak is quite large as I can hear hissing. Also noticed while conducting leak search evap coil was frozen. Checked warranty status and found the system is no longer under warranty. Discussed options for going forward to address the issue including replacement of the coil and system replacement. Advised homeowner running the system further is going to cause damage to the system. Homeowner would like the condenser coil cleaned during the coil replacement. We are bringing a window unit 1-3 today and installing the coil 1-3 tomorrow.
Sherman, TX 75092
Sherman, TX - Homeowner stated unit was not keeping up with set point. Tested supply temp and only measured 64-65. Measured refrigerant pressures and found them to be low on refrigerant. Conducted courtesy leak check and found a leak at the evaporator coil. Leak is quite large as I can hear hissing.  Also noticed  while conducting leak search evap coil was frozen. Checked warranty status and found the system is no longer under warranty. Discussed options for going forward to address the issue including replacement of the coil and system replacement. Advised homeowner running the system further is going to cause damage to the system. Homeowner would like the condenser coil cleaned during the coil replacement. We are bringing a window unit 1-3 today and installing the coil 1-3 tomorrow.
Sherman, TX - Homeowner stated unit was not keeping up with set point. Tested supply temp and only measured 64-65. Measured refrigerant pressures and found them to be low on refrigerant. Conducted courtesy leak check and found a leak at the evaporator coil. Leak is quite large as I can hear hissing.  Also noticed  while conducting leak search evap coil was frozen. Checked warranty status and found the system is no longer under warranty. Discussed options for going forward to address the issue including replacement of the coil and system replacement. Advised homeowner running the system further is going to cause damage to the system. Homeowner would like the condenser coil cleaned during the coil replacement. We are bringing a window unit 1-3 today and installing the coil 1-3 tomorrow.
Matthew C.
Matthew C.
Preformed single system maintenance on a 2020 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I did notice the uv stick to be out and not working. This helps kill any growth or bacteria growing in the system. I treated drain line with total c and water. I changed the filter for the client 20x20x1. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed the suction line to be missing the uv armaflex that helps protect the suction line. Unit is cooling upon departure
Sherman, TX 75090
Sherman, TX - Preformed single system maintenance on a 2020 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I did notice the uv stick to be out and not working. This helps kill any growth or bacteria growing in the system. I treated drain line with total c and water. I changed the filter for the client 20x20x1. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed the suction line to be missing the uv armaflex that helps protect the suction line. Unit is cooling upon departure
Sherman, TX - Preformed single system maintenance on a 2020 heat pump. I tested all electrical components on the inside unit. All tested within manufacturer specifications. I did notice the uv stick to be out and not working. This helps kill any growth or bacteria growing in the system. I treated drain line with total c and water. I changed the filter for the client 20x20x1. I tested all electrical components on the outside unit and all tested within manufacturer specifications. I rinsed the outdoor unit with water at today's visit. I noticed the suction line to be missing the uv armaflex that helps protect the suction line. Unit is cooling upon departure
Shelby S.
Shelby S.
Upon arrival, the customer gave me more information on the water being in the pan. She stated that the water would over flow indicating that there is a clog present. I managed to locate the termination point under the house. After finding that, I was informed of an issue at the outdoor unit. The condenser fan motor is seized up. I presented pricing to address these issues at the time of service.
Sherman, TX 75090
Sherman, TX - Upon arrival, the customer gave me more information on the water being in the pan. She stated that the water would over flow indicating that there is a clog present. I managed to locate the termination point under the house. After finding that, I was informed of an issue at the outdoor unit. The condenser fan motor is seized up. I presented pricing to address these issues at the time of service.
Sherman, TX - Upon arrival, the customer gave me more information on the water being in the pan. She stated that the water would over flow indicating that there is a clog present. I managed to locate the termination point under the house. After finding that, I was informed of an issue at the outdoor unit. The condenser fan motor is seized up. I presented pricing to address these issues at the time of service.
Brayden W.
Brayden W.
Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Sherman, TX 75090
Sherman, TX - Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Sherman, TX - Came out today for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Getting over 20 degree temp split. Drain line is draining at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Matthew C.
Matthew C.
Found drain line clogged on number 4 causing back up into the pan. Pan began over flowing into the ceiling tile Unclogging of drain line.
Sherman, TX 75090
Sherman, TX - Found drain line clogged on number 4 causing back up into the pan. Pan began over flowing into the ceiling tile 

Unclogging of drain line.
Sherman, TX - Found drain line clogged on number 4 causing back up into the pan. Pan began over flowing into the ceiling tile 

Unclogging of drain line.
Brayden W.
Brayden W.
Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Measured 20 degree temp split. Drain line is draining well at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Sherman, TX 75092
Sherman, TX - Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Measured 20 degree temp split. Drain line is draining well at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Sherman, TX - Arrived on site for QC visit on new install. Started inside at t-stat (Trane) turned system down to check over unit. System is level all wiring is good no error codes. Measured 20 degree temp split. Drain line is draining well at this time. System is clean and operating as designed. Outside unit is level all electrical components are good and tight. All components are operating as designed. Pressures were within manufacturer specifications. Tested normal heating operation. System in good working order upon departure. Thank you for your time.
Shelby S.
Shelby S.
The system does not appear to be cooling efficiently. I advise that a thorough cleaning of the evaporator coil and condenser coil be performed. This will allow for optimum temperature transfer across the coils. 5/20/26 - I returned and performed cleanings of the downstairs evaporator coil and condensing coil. The original supply temperature was 54 and only had a 16 degree temperature split. After cleaning was performed, the supply temperature went to 48.9. This is now a 21.1 degree temperature drop. System is now cooling more efficiently.
Sherman, TX 75090
Sherman, TX - The system does not appear to be cooling efficiently. I advise that a thorough cleaning of the evaporator coil and condenser coil be performed. This will allow for optimum temperature transfer across the coils.

5/20/26 - I returned and performed cleanings of the downstairs evaporator coil and condensing coil. The original supply temperature was 54 and only had a 16 degree temperature split. After cleaning was performed, the supply temperature went to 48.9. This is now a 21.1 degree temperature drop. System is now cooling more efficiently.
Sherman, TX - The system does not appear to be cooling efficiently. I advise that a thorough cleaning of the evaporator coil and condenser coil be performed. This will allow for optimum temperature transfer across the coils.

5/20/26 - I returned and performed cleanings of the downstairs evaporator coil and condensing coil. The original supply temperature was 54 and only had a 16 degree temperature split. After cleaning was performed, the supply temperature went to 48.9. This is now a 21.1 degree temperature drop. System is now cooling more efficiently.
Brayden W.
Brayden W.
Homeowner stated master bedroom was not staying as cool as it should and front of the house was cooler. Reviewed and tested damper operation. Found one damper for downstairs working properly. Found 2 dampers upstairs tied together on one zone. Tested upstairs dampers and found one of them not responding. Reviewed wiring and found loose wiring connection to second damper. Tightened connection and tested again and found all dampers to be working as designed. Tested bypass damper and found it working as intended. Tested airflow in master bedroom downstairs and found this grill to be getting much more airflow than before. This should address the temperature imbalance. Answered homeowner questions about thermostat and adjusted brightness settings so that the thermostat is not shining on her in bed. Advised homeowner to give us a call should there be any further imbalances but I am confident our adjustments today should take care of it. System running upon departure.
Sherman, TX 75090
Sherman, TX - Homeowner stated master bedroom was not staying as cool as it should and front of the house was cooler. Reviewed and tested damper operation. Found one damper for downstairs working properly. Found 2 dampers upstairs tied together on one zone. Tested upstairs dampers and found one of them not responding. Reviewed wiring and found loose wiring connection to second damper. Tightened connection and tested again and found all dampers to be working as designed. Tested bypass damper and found it working as intended. Tested airflow in master bedroom downstairs and found this grill to be getting much more airflow than before. This should address the temperature imbalance. Answered homeowner questions about thermostat and adjusted brightness settings so that the thermostat is not shining on her in bed. Advised homeowner to give us a call should there be any further imbalances but I am confident our adjustments today should take care of it. 
System running upon departure.
Sherman, TX - Homeowner stated master bedroom was not staying as cool as it should and front of the house was cooler. Reviewed and tested damper operation. Found one damper for downstairs working properly. Found 2 dampers upstairs tied together on one zone. Tested upstairs dampers and found one of them not responding. Reviewed wiring and found loose wiring connection to second damper. Tightened connection and tested again and found all dampers to be working as designed. Tested bypass damper and found it working as intended. Tested airflow in master bedroom downstairs and found this grill to be getting much more airflow than before. This should address the temperature imbalance. Answered homeowner questions about thermostat and adjusted brightness settings so that the thermostat is not shining on her in bed. Advised homeowner to give us a call should there be any further imbalances but I am confident our adjustments today should take care of it. 
System running upon departure.
Shelby S.
Shelby S.
Upon arrival, I discovered that the system was operating normally. After further investigation, I found that the system was low on R410a. I provided a quick leak inspection and could not pin point the leak, but I did have oil residue in the evaporator coil cabinet. I went over the options with the customer, and he opted to fill the system up with no warranty or guarantee. The indoor manufacture date is 2017 and the outdoor is 2018. Both units are outside of warranty. The system is cooling with a 20 degree temperature split upon departure. While watching pressures, I noticed that the subcool did not want to come to the target range of 7 - 9. The liquid pressure did not want to come up either. It appears the TXV is stuck open not allowing the refrigerant to flow correctly through the TXV.
Sherman, TX 75092
Sherman, TX - Upon arrival, I discovered that the system was operating normally. After further investigation, I found that the system was low on R410a. I provided a quick leak inspection and could not pin point the leak, but I did have oil residue in the evaporator coil cabinet. I went over the options with the customer, and he opted to fill the system up with no warranty or guarantee. The indoor manufacture date is 2017 and the outdoor is 2018. Both units are outside of warranty. The system is cooling with a 20 degree temperature split upon departure. While watching pressures, I noticed that the subcool did not want to come to the target range of 7 - 9. The liquid pressure did not want to come up either. It appears the TXV is stuck open not allowing the refrigerant to flow correctly through the TXV.
Sherman, TX - Upon arrival, I discovered that the system was operating normally. After further investigation, I found that the system was low on R410a. I provided a quick leak inspection and could not pin point the leak, but I did have oil residue in the evaporator coil cabinet. I went over the options with the customer, and he opted to fill the system up with no warranty or guarantee. The indoor manufacture date is 2017 and the outdoor is 2018. Both units are outside of warranty. The system is cooling with a 20 degree temperature split upon departure. While watching pressures, I noticed that the subcool did not want to come to the target range of 7 - 9. The liquid pressure did not want to come up either. It appears the TXV is stuck open not allowing the refrigerant to flow correctly through the TXV.
Shelby S.
Shelby S.
I performed a 2 system cooling maintenance. The downstairs is 2020 airhandler and a 2023 heat pump. The upstairs is a complete 2023 heat pump system. I checked amps, capacitors, filters, electrical, drains, cleanliness, and safeties. During my thorough evaluation, I discovered that the downstairs is having a minor cooling issue. I advised performing a deep cleaning on both coils to restore the efficiency of the system. The upstairs is performing well mechanically. However, I noticed the design of the drain needs to be corrected. The emergency drain is completely capped off and will cause water damage when the drain becomes clogged. I presented options for address these issues at the time of service. The emergency drain is capped off. If a clog occurs, it will cause water to backup into the system. The causes a risk of water damage to the electrical of the equipment and the inside of the unit rusting out. Customer opted to do the cleanings and redesign the secondary drain. I performed
Sherman, TX 75090
Sherman, TX - I performed a 2 system cooling maintenance. The downstairs is 2020 airhandler and a 2023 heat pump. The upstairs is a complete 2023 heat pump system. I checked amps, capacitors, filters, electrical, drains, cleanliness, and safeties. During my thorough evaluation, I discovered that the downstairs is having a minor cooling issue. I advised performing a deep cleaning on both coils to restore the efficiency of the system. The upstairs is performing well mechanically. However, I noticed the design of the drain needs to be corrected. The emergency drain is completely capped off and will cause water damage when the drain becomes clogged. I presented options for address these issues at the time of service. 
The emergency drain is capped off. If a clog occurs, it will cause water to backup into the system. The causes a risk of water damage to the electrical of the equipment and the inside of the unit rusting out. Customer opted to do the cleanings and redesign the secondary drain. I performed
Sherman, TX - I performed a 2 system cooling maintenance. The downstairs is 2020 airhandler and a 2023 heat pump. The upstairs is a complete 2023 heat pump system. I checked amps, capacitors, filters, electrical, drains, cleanliness, and safeties. During my thorough evaluation, I discovered that the downstairs is having a minor cooling issue. I advised performing a deep cleaning on both coils to restore the efficiency of the system. The upstairs is performing well mechanically. However, I noticed the design of the drain needs to be corrected. The emergency drain is completely capped off and will cause water damage when the drain becomes clogged. I presented options for address these issues at the time of service. 
The emergency drain is capped off. If a clog occurs, it will cause water to backup into the system. The causes a risk of water damage to the electrical of the equipment and the inside of the unit rusting out. Customer opted to do the cleanings and redesign the secondary drain. I performed

Your High Efficiency