Whitewright TX Heating And Air Conditioning

 

Whether it’s keeping you comfy in summer heat or winter cold, Adon has all your heating and air conditioning solutions in Whitewright, TX and the surrounding areas!

Our customers in Whitewright, TX love our heating and air conditioning work. But don’t take our word for it! Read the reviews below to see for yourself.

Local Reviews
for Whitewright, TX

Adon Complete Air Conditioning and Heating Rated 5.0 out of 5 stars based on 1 customer reviews


Map of Whitewright, TX 75491

Great service by professional, knowledgeable techs




Review of Adon Complete Air Conditioning and Heating

Frank and Zak are both extremely knowledgeable techs who present a professionalism not seen in most representatives of companies today. I am extremely satisfied with your company if they are a reflection of the caliber of quality and knowledge that your techs hold. Two great techs that you are fortunate to have representing your company. Great job- extremely pleased.

WhitewrightTX75491 33.4725-96.44

Matthew C.

Matthew C.

Preformed single system heating maintenance on a 2025 gas furnace. I tested all electrical components and safeties. All tested within manufacturer specifications. Tempture being supplied to the home was at 116 and 71 return air. Filter size is Aprilaire 410. It does need to be changed, client did not have filters at the time of inspection. I proceeded outside to visually inspected the outside unit. Everything was in good working order. I did notice that the system did not have any type of surge protection. I provided estimates to have surge protection installed. Unit was heating upon departure.

Near Lyon St, Whitewright, TX 75491
Whitewright, TX - Preformed single system heating maintenance on a 2025 gas furnace. I tested all electrical components and safeties. All tested within manufacturer specifications. Tempture being supplied to the home was at 116 and 71 return air. Filter size is Aprilaire 410. It does need to be changed, client did not have filters at the time of inspection. I proceeded outside to visually inspected the outside unit. Everything was in good working order. I did notice that the system did not have any type of surge protection. I provided estimates to have surge protection installed. Unit was heating upon departure. Whitewright, TX - Preformed single system heating maintenance on a 2025 gas furnace. I tested all electrical components and safeties. All tested within manufacturer specifications. Tempture being supplied to the home was at 116 and 71 return air. Filter size is Aprilaire 410. It does need to be changed, client did not have filters at the time of inspection. I proceeded outside to visually inspected the outside unit. Everything was in good working order. I did notice that the system did not have any type of surge protection. I provided estimates to have surge protection installed. Unit was heating upon departure.
Brayden W.

Brayden W.

Arrived on site customer stated all is well with normal system operation on the main house, however he stated the unit at the other house was having issues. 1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out Began inspection at the main house and noticed oil in the drain pan from a refrigerant leak. Discussed this with the homeowner they had known about i

Near W Oak St, Whitewright, TX 75491
Whitewright, TX - Arrived on site customer stated all is well with normal system operation on the main house, however he stated the unit at the other house was having issues.  
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out 
Began inspection at the main house and noticed oil in the drain pan from a refrigerant leak. Discussed this with the homeowner they had known about i Whitewright, TX - Arrived on site customer stated all is well with normal system operation on the main house, however he stated the unit at the other house was having issues.  
1. Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14.Drain line tested with gallon of water for clogs and to push anything trying to solidify out 
Began inspection at the main house and noticed oil in the drain pan from a refrigerant leak. Discussed this with the homeowner they had known about i
Brayden W.

Brayden W.

Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested for gas leaks 6. Tested functionality and cleaned flame sensor 7. Tested functionality and cleaned pressure switches and ports 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Tested functionality and visually inspected surface igniter 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Drain line tested with gallon of water for clogs and to push anything trying to solidify out Performed blower wheel cleaning. Unit in good working order at this time

Near W Grand St, Whitewright, TX 75491
Whitewright, TX - Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Performed blower wheel cleaning. Unit in good working order at this time

Whitewright, TX - Visually inspected condenser coil for debris/ dirty.
2. Inspected condenser fan motor.
3. Inspected condenser fan blades.
4. Inspected/ cleaned wiring connections.
5. Tested for gas leaks
6. Tested functionality and cleaned flame sensor
7. Tested functionality and cleaned pressure switches and ports
8. Inspected / replaced return filter.
9. Inspected return plenum for debris/ dirty.
10. Inspected evaporator coil.
11. Tested functionality and visually inspected surface igniter
12. Checked blower amp draw.
13. Measured temperature differential from supply to return. 20 degrees measured.
14. Drain line tested with gallon of water for clogs and to push anything trying to solidify out

Performed blower wheel cleaning. Unit in good working order at this time
Shelby S.

Shelby S.

I performed a single system heating maintenance on a straight cool system. I checked amps, filters, electrical, and cleanliness. I noticed that the blower wheel is filthy. This causes strain on the internal bearings and overworking of the blower motor. I observed that the blower motor has some play in the shaft likely due to the build up. I advise cleaning before major failure occurs. System is heating upon departure.

Near Chicken Field Rd, Whitewright, TX 75491
Whitewright, TX - I performed a single system heating maintenance on a straight cool system. I checked amps, filters, electrical, and cleanliness. I noticed that the blower wheel is filthy. This causes strain on the internal bearings and overworking of the blower motor. I observed that the blower motor has some play in the shaft likely due to the build up. I advise cleaning before major failure occurs. System is heating upon departure. Whitewright, TX - I performed a single system heating maintenance on a straight cool system. I checked amps, filters, electrical, and cleanliness. I noticed that the blower wheel is filthy. This causes strain on the internal bearings and overworking of the blower motor. I observed that the blower motor has some play in the shaft likely due to the build up. I advise cleaning before major failure occurs. System is heating upon departure.
Matthew C.

Matthew C.

Performed a complete heating system maintenance and inspection 2018 heat pump. Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications. Verified system temperatures: return air temperature measured at 77°F; supply air temperature measured at 104°F and rising. Confirmed air filter was needing to be replaced. I replaced he filter on today’s visit; filter size is 20” x 20” x 1”. Inspected and tested all electrical components on the outdoor unit; all components tested within manufacturer specifications. Confirmed system was operating properly and heating upon departure. System Status: Operating normally at time of service.

Near County Rd 4524, Whitewright, TX 75491
Whitewright, TX - Performed a complete heating system maintenance and inspection 2018 heat pump.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 77°F; supply air temperature measured at 104°F and rising.

Confirmed air filter was needing to be replaced. I replaced he filter on today’s visit; filter size is 20” x 20” x 1”. 

Inspected and tested all electrical components on the outdoor unit; all 
components tested within manufacturer specifications.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service. Whitewright, TX - Performed a complete heating system maintenance and inspection 2018 heat pump.

Inspected and tested all electrical components and safety controls on the indoor unit; all components tested within manufacturer specifications.

Verified system temperatures: return air temperature measured at 77°F; supply air temperature measured at 104°F and rising.

Confirmed air filter was needing to be replaced. I replaced he filter on today’s visit; filter size is 20” x 20” x 1”. 

Inspected and tested all electrical components on the outdoor unit; all 
components tested within manufacturer specifications.

Confirmed system was operating properly and heating upon departure.

System Status: Operating normally at time of service.
Jacob P.

Jacob P.

Arrived at our clients home for a mini split estimate. Our client had installed a Mr cool unit and it had no warranties. It had a leak on the indoor coil and our Clint wanted a replacement unit for his train house. We discussed replacement uptown and I found the outdoor power to be just a 120v outlet with a plug. We discussed upgrading this and also adding a surge protector to the equipment. We also discussed and agreed to preform 1 year of maintenance on 2 other units on his property for free. We will provide a heating and cooling maintenance. The date of the installation is scheduled for Friday the 26th. I collected a $1,000 equipment deposit today.

Near W Oak St, Whitewright, TX 75491
Whitewright, TX - Arrived at our clients home for a mini split estimate. Our client had installed a Mr cool unit and it had no warranties. It had a leak on the indoor coil and our Clint wanted a replacement unit for his train house. We discussed replacement uptown and I found the outdoor power to be just a 120v outlet with a plug. We discussed upgrading this and also adding a surge protector to the equipment.
We also discussed and agreed to preform 1 year of maintenance on 2 other units on his property for free. We will provide a heating and cooling maintenance.
The date of the installation is scheduled for Friday the 26th. I collected a $1,000 equipment deposit today.
Whitewright, TX - Arrived at our clients home for a mini split estimate. Our client had installed a Mr cool unit and it had no warranties. It had a leak on the indoor coil and our Clint wanted a replacement unit for his train house. We discussed replacement uptown and I found the outdoor power to be just a 120v outlet with a plug. We discussed upgrading this and also adding a surge protector to the equipment.
We also discussed and agreed to preform 1 year of maintenance on 2 other units on his property for free. We will provide a heating and cooling maintenance.
The date of the installation is scheduled for Friday the 26th. I collected a $1,000 equipment deposit today.
Shelby S.

Shelby S.

Upon arrival, I found the system fully operational and satisfied. I cycled the system on and checked my electrical and refrigerant pressures. According to the charge chart, the system needs a top off on 454B. Customer is not available until 8/19/25. Scheduled for installers to come back on 8/19/25 at 8am. We will call and confirm appointment on 8/18/25.

Near Lyon St, Whitewright, TX 75491
Whitewright, TX - Upon arrival, I found the system fully operational and satisfied. I cycled the system on and checked my electrical and refrigerant pressures. According to the charge chart, the system needs a top off on 454B. Customer is not available until 8/19/25. Scheduled for installers to come back on 8/19/25 at 8am. We will call and confirm appointment on 8/18/25. Whitewright, TX - Upon arrival, I found the system fully operational and satisfied. I cycled the system on and checked my electrical and refrigerant pressures. According to the charge chart, the system needs a top off on 454B. Customer is not available until 8/19/25. Scheduled for installers to come back on 8/19/25 at 8am. We will call and confirm appointment on 8/18/25.
Jacob P.

Jacob P.

Arrived to the outdoor unit making a loud whirling noise. We had recently preformed some work to help keep the compressor working. I immediately found that it was a failing condenser fan motor. The motor was not spinning fast enough and the bearings were grinding. I showed my finding to our client and we discussed repairs vs replacement options. He elected to move forward with the replacement and we are scheduled to install the equipment on Friday. We will be running new copper Line set as well as adding two additional return vents in each bedroom. *** New furnace requires propane kit*** Client requested to have us install his provided thermostat $1,500 deposit collected. To be deducted from total amount financed

Near Lyon St, Whitewright, TX 75491
Whitewright, TX - Arrived to the outdoor unit making a loud whirling noise. We had recently preformed some work to help keep the compressor working. I immediately found that it was a failing condenser fan motor. The motor was not spinning fast enough and the bearings were grinding. 
I showed my finding to our client and we discussed repairs vs replacement options. 
He elected to move forward with the replacement and we are scheduled to install the equipment on Friday. 

We will be running new copper Line set as well as adding two additional return vents in each bedroom. 
*** New furnace requires propane kit***
Client requested to have us install his provided thermostat 

$1,500 deposit collected. To be deducted from total amount financed Whitewright, TX - Arrived to the outdoor unit making a loud whirling noise. We had recently preformed some work to help keep the compressor working. I immediately found that it was a failing condenser fan motor. The motor was not spinning fast enough and the bearings were grinding. 
I showed my finding to our client and we discussed repairs vs replacement options. 
He elected to move forward with the replacement and we are scheduled to install the equipment on Friday. 

We will be running new copper Line set as well as adding two additional return vents in each bedroom. 
*** New furnace requires propane kit***
Client requested to have us install his provided thermostat 

$1,500 deposit collected. To be deducted from total amount financed
Brayden W.

Brayden W.

1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Rinsed condenser unit to promote heat exchange Found grass growing into the condenser coil. Recommended to customer spraying herbicide 6-8 inches around the condenser to prevent the grass from growing into the coil and blocking airflow.

Near Private Rd 425, Whitewright, TX 75491
Owen J.

Owen J.

Homeowner met me outside at arrival. Performed AC/cooling maintenance/diagnostic. Homeowner has a clean washable filter currently installed. Checked all electrical components/temperatures, drains. Water rinse outside condenser coil. Filled out cooling maintenance form. Blower wheel needs pulled and cleaned. (Estimate Sent) Evaporator needs cleaned. (Estimate Sent) Recommend new Contactor and hard start kit installation. (Estimate Sent) Missing insulation at outdoor copper lines. Estimate sent. System provides a 15°F temperature drop across the coil. System currently cooling/draining properly at this time but recommended repairs that were sent… would help improve efficiency and temperature drop across the coil.

Near Chicken Field Rd, Whitewright, TX 75491
Brayden W.

Brayden W.

Customer requested 8-10 last thrus October for heating maintenance and other blower wheel cleaning. Removed and Cleaned blower wheel and tested system to ensure normal operation. Measured blower amps and they were testing more than an amp lower than before.

Near W Grand St, Whitewright, TX 75491
Owen J.

Owen J.

Removed water from both hvac & water heater drain pans…. Attempted to clear primary. Recommend two additional shut off valves where HVAC and water heater drain both tee in together. Unable to perform this recommended repair due to not enough three-quarter inch PVC exposed out of wall cavity. (See photo) Tech/installer Will need to have more Three-quarter inch PVC exposed out of wall. so that existing assembly can be cut out to rebuild junction with two new Jones blow out valves (One for water heater and one for AC ) Already Left estimates for new drain pan. Highly recommend a comfort advisor visit. (Evaporator coil, deteriorating/falling apart unable to threat in PVC fitting into secondary discharge port. Therefore, it is leaking onto makeshift drain pan. Also issues with primary drain where it ties into water heater.)

Near Lyon St, Whitewright, TX 75491
Owen J.

Owen J.

Performed one system hvac maintenance. - On arrival, found emergency drain pan retaining water and rerouting outside due to a clogged/restricted primary drain that ties in with the water heater.. - Emergency pan is just sitting on like cradling on plumber strap and not actually screwed to the pan. Upon accessing indoor equipment and examining pan water almost rushed out of pan but was able to stop it before it hit the attic floor/ceiling causing damage. - Notified homeowner of critical water issue and homeowner authorized level three drain clearing package, including SS1 float switch, & Jones blowout valve. Perform the service immediately to prevent water damage. - System AC/cooling maintenance: Water rinsed condenser coils. Found compromised capacitor and contactor on condenser. Blower motor wheel dirty. Homeowner authorized bundle package with new contactor, capacitor, and hard start kit to keep old R 22 system alive. - After performing AC diagnostics and repairs. Re-tested syste

Near Lyon St, Whitewright, TX 75491
Owen J.

Owen J.

Upon arrival homeowner met me in driveway. Explained to me that his thermostat was intermittently powering off. Thermostat was powered on when I walked up to it. Ran a call for cooling from thermostat. At arrival primary drain line & auxiliary/emergency drain pan had no retained water. After a few minutes of operating in cooling mode, primary began to back up due to restriction between hvac and bathroom sink. Indoor blower motor has significant buildup on the blower wheel which negatively affects blower motor and will lead to premature failure….also causes the equipment to perform inadequately with low efficiency. Suction line Armaflex insulation is damaged at indoor air handler and completely missing at the outdoor equipment. Homeowner declined all recommendations for repairs and said he was going to have his friend come perform service. Emailed estimates.

Near Sharon Ln, Whitewright, TX 75491
Brayden W.

Brayden W.

Contactor testing low. Strong possibility of failure. Contactor replaced unit in good working order upon departure.

Near County Rd 4524, Whitewright, TX 75491
Brayden W.

Brayden W.

1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange Blower motor cleaning scheduled for 27th of July friday 8 o’clock Customer wants downstairs blower cleaning in fall

Near W Grand St, Whitewright, TX 75491
Brayden W.

Brayden W.

1. Visually inspected condenser coil for debris/ dirty. 2. Inspected condenser fan motor. 3. Inspected condenser fan blades. 4. Inspected/ cleaned wiring connections. 5. Tested compressor/ condenser fan motor capacitor. 6. Checked compressor amp draw. 7. Checked condenser fan motor amp draw. 8. Inspected / replaced return filter. 9. Inspected return plenum for debris/ dirty. 10. Inspected evaporator coil. 11. Inspected blower motor/ blower wheel. 12. Checked blower amp draw. 13. Measured temperature differential from supply to return. 20 degrees measured. 14. Inspected drain lines and treated to prevent blockages 15. Washed condenser unit to promote heat exchange Blower motor and blower wheel covered and growth. Removed and disassembled blower wheel and housing and thoroughly cleaned with chemicals. Recommend replacing contactor as it is testing low and expected to fail.

Near County Rd 4524, Whitewright, TX 75491
Shelby S.

Shelby S.

Examined the design of the dryer vent, supply registers, return registers, and equipment cleanliness. I provided pricing for duct cleaning, dryer vent, and the blower. I hooked up my air advice and it didn’t send the form to my iPad. I referred to an air advice reading back in 2023. We have t perform any cleaning and informed the customer that would’ve only progressed from that point.

Near W Melody Dr, Whitewright, TX 75491
Jacob P.

Jacob P.

Arrived at the property for ac not cooling properly client stated that issue had been happening for about a week, and periodically working and not working. We initially diagnosed a failed high pressure switch. We did temporarily bypass the switch and were able to get power to the turn the unit on and further diagnosed a failed outdoor fan motor. We brought all our findings to our clients attention. Spoke to client about possibly getting a new unit. Client decided to get second opinion.

Near FM1752, Whitewright, TX 75491
Jacob P.

Jacob P.

Arrived on site customer stated all was well with regards to normal system operation. Started inspection at the air handler. Customer had recently changed filter. Capacitor was testing outside of manufacture specs recommend replacement. Blower motor amps were a little high and it was noticed that there was a good amount of dust accumulation on the blower wheel that could lead to a premature failure of the blower motor. Recommend blower cleaning. Upon inspection of the outdoor unit, it was noticed that both the compressor capacitor and the fan capacitor were testing outside of manufacturer specifications. Recommend replacement to ensure system longevity. Contactor was testing within range. Compressor start amps were slightly high, but not concerning. Compressor and fan run amps were within range. Washed outdoor condenser coils to promote heat exchange and prolong system life. Customer stated he did not have more time as he had an appointment and with call in to the office to get repairs

Near W Melody Dr, Whitewright, TX 75491
Shelby S.

Shelby S.

Performed single system heating maintenance. I checked electrical, cleanliness, drains, filter, and safeties. The system is now heating at full capacity.

Near Private Rd 425, Whitewright, TX 75491
Shelby S.

Shelby S.

Performed single system heating maintenance. Checked amps, capacitor, filter, electrical, cleanliness, drains, and safeties. System is heating to manufacture specifications. Recommendations 1. Performing a cleaning on the blower due to high amount of growth present. 2. Installing a u/v light to sterilize the inside of the airhandler to try and prevent growth from returning (should be done after blower is clean)

Near County Rd 4524, Whitewright, TX 75491
Alex G.

Alex G.

2016 train downflow with straight electric heat everything operating with the manufacturing specs heat kit is operational working no heat pump outdoor recently replaced capacitor on condensing unit still within the plus -5% range of recommended changing did send a quote for a pulling clean on the evaporator coil into a little buildup debris

Near Chicken Field Rd, Whitewright, TX 75491
Shelby S.

Shelby S.

Found the fan set to on with the cycle set to off. This caused the blower to run continuously. I switched the fan to auto and the fan shut off. Cycled the system a couple of times and it shut off normally. I checked the refrigerant pressures and determined the system has a liquid line restriction due to it having low suction pressure, slightly low liquid pressure, high superheat, and high sub cooling. I priced to pump the system down and replace the liquid line drier, purge the line set with nitrogen, check the piston, pressure test, and vacuum the refrigerant lines.

Near W Melody Dr, Whitewright, TX 75491
Shelby S.

Shelby S.

We are not within price range that customer is comfortable with. System has 15 supplies and 2 returns. Blower is dirty and needs cleaning. Customer asked about leveling outdoor system and was not interested in the range I gave her.

Near Dixie Ln, Whitewright, TX 75491

 